GE Spacemaker® Stationary Dryer
Dimensions and Installation Information (in inches)
Shown with WSLP1100A or WSLS1100A and Stack Rack DSDR24D
For answers to your Monogram,® GE Profile™ or GE® appliance questions, visit our website at ge.com or call GE Answer Center® service,
800.626.2000.
Specification Revised 9/07
Listed by Underwriters Laboratories
360432
DSKS433EB
GE Spacemaker® Stationary Dryer
Dimensions and Installation Information (in inches)
Special Installation Requirements Alcove or Closet Installation:
• If your dryer is approved for installation in an alcove or closet, it will be stated on a label on the dryer back.
• The dryer MUST be exhausted to the outside.
• Minimum clearances between dryer cabinet and adjacent walls or other surfaces are: 0" either side
3" front and rear
• Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52”.
• Closet doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq. in. of open area equally distributed. If this closet contains both a washer and a dryer, doors must contain a minimum of 120 sq. in. of open area equally distributed.
• No other fuel-burning appliance shall be installed in the same closet with a gas dryer.
Bathroom or Bedroom Installation:
• The dryer MUST be exhausted to the outdoors.
• The installation must conform with the local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.
Minimum Clearances other than Alcove or Closet Installation:
• Minimum clearances to combustible surfaces 0" both sides
3" rear
For answers to your Monogram,® GE Profile™ or GE® appliance questions, visit our website at ge.com or call GE Answer Center® service,
800.626.2000.
Specification Revised 9/07
Listed by Underwriters Laboratories
360432
DSKS433EB
80
10
0
10
90
O
F
F
O
F
F
60
50
40
30
20
70
c
o
o
l
d
o
w
n
P
E
R
M
.
P
R
E
S
S
&
D
E
L
I
C
A
T
E
S
C
Y
C
L
E
*P
R
E
F
E
R
R
E
D
R
E
G
U
L
A
R
S
E
T
T
I
N
G
T
I
M
E
D
C
Y
C
L
E
PUSH
T
O
ST
AR
T
A
U
TO
R
E
G
U
L
A
R
TEMPER A
T
URE
RE
GULAR
(HIGH HEA
T)
PERM PRES
S
(MED
.
HEA
T)
DELI
CA
TES
(L
OW
HEA
T)
FLUFF
(NO HEA
T)
N
O
R
M
A
L
D
R
Y
*
O
F
F
c
o
o
l
d
o
w
n
c
o
o
l
d
o
w
n
E
X
T
R
A
D
R
Y
*
N
O
R
M
A
L
D
R
Y
E
X
T
R
A
D
R
Y
GE Spacemaker® Stationary Dryer
Dimensions and Installation Information (in inches)
Dryer Note: Dryer wall outlet must be located within 36" of service
cord entry and accessible when dryer is mounted in position.
33-1/4
24-1/2
23-7/8
For complete information, see installation instructions packed with your dryer.
Ducting Materials:
For best performance, this dryer should be vented with 4" diameter all rigid metal exhaust duct. If “all rigid metal” duct cannot be used, then “flexible all metal” venting can be used, but it will reduce the maximum recommended duct length.
Exhaust Length Calculation:
1. Determine the number of 90° turns needed for your installation. If you exhaust to the side or bottom of dryer, add one turn.
2. The maximum length of 4' rigid (aluminum or galvanized) duct which can be tolerated is shown in the table. The maximum length for flexible ducts are less than for rigid duct.
A turn of 45° or less may be ignored. Two 45° turns within the duct length should be
treated as a 90° elbow. A turn over 45° should be treated as a 90° elbow.
Exhausting the dryer to the outside is strongly recommended to prevent large amounts of moisture and lint from being blown into the room. Gas dryers or any dryer located in a closet must be exhausted to the outside.
Caution: For personal safety do not terminate exhaust into a chimney, under any enclosed house floor (crawl space), or into an attic, since the accumulated lint could create a fire hazard or moisture could cause damage. Never terminate the exhaust into a common duct or plenum with a kitchen exhaust, since the combination of lint and grease could create a fire hazard.
Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts, bird nesting, etc. The wall cap must also be located at least 12" above the ground or any other obstruction with the opening pointed down.
For answers to your Monogram,® GE Profile™ or GE® appliance questions, visit our website at ge.com or call GE Answer Center® service,
800.626.2000.
Other terminations, such as louvered wall boxes, are acceptable provided they are equivalent to a 4" opening dampered wall cap.
Listed by Underwriters Laboratories
Specification Revised 9/07
360432
DSKS433EB
80
10
0
10
90
O
F
F
O
F
F
60
50
40
30
20
70
c
o
o
l
d
o
w
n
P
E
R
M
.
P
R
E
S
S
&
D
E
L
I
C
A
T
E
S
C
Y
C
L
E
*P
R
E
F
E
R
R
E
D
R
E
G
U
L
A
R
S
E
T
T
I
N
G
T
I
M
E
D
C
Y
C
L
E
PUSH
T
O
ST
AR
T
A
U
TO
R
E
G
U
L
A
R
TEMPE RA
T
URE
RE
GULAR
(HIGH HEA
T)
PERM PRES
S
(MED
.
HEA
T)
DELI
CA
TES
(L
OW
HEA
T)
FLUFF
(NO HEA
T)
N
O
R
M
A
L
D
R
Y
*
O
F
F
c
o
o
l
d
o
w
n
c
o
o
l
d
o
w
n
E
X
T
R
A
D
R
Y
*
N
O
R
M
A
L
D
R
Y
E
X
T
R
A
D
R
Y
GE Spacemaker® Stationary Dryer
Features and Benefits
• Auto Dry – Uses thermostats to monitor air temperature and reduce fabric wear
• Multiple Heat Selections – Offers enhanced drying performance and fabric care
• Multiple Dry Cycles – Deliver optimal drying results
• Rotary Mechanical Controls – Are straightforward and easy to turn
• Upfront Lint Filter – Easy to reach and clean
• Model DSKS433EBWW – White on white
• Model DSKS433EBWH – White
For answers to your Monogram,® GE Profile™ or GE® appliance questions, visit our website at ge.com or call GE Answer Center® service,
800.626.2000.
Listed by Underwriters Laboratories
Specification Revised 9/07