Customer service ............................................... Back cover
Introduction
The DPI 800 Pressure Indicator and DPI 802 Pressure Loop
Calibrator are part of the Druck DPI 800 series of hand held
instruments.
The DPI 800 series uses Intelligent Digital Output Sensor
(IDOS) technology to give instant plug and play
functionality with a range of Universal Measurement
Modules (UMM). Example: the Universal Pressure Module
(UPM).
The DPI 800/802 include these functions:
FunctionDPI 800DPI 802
Measure pressure *
Measure pressure
difference ***
Leak TestYes
Communications portIDOS or RS232
Language selectionYes
Pressure u nits25 (Fixed )
Snapshot **Up to 1000 displays with a date/time stamp
Measure mANo0 - 55 mA
HART® resistorNoYes
V dc outputNo 24 V
Switch testNoYes
Other functionsHold, Maximum/Minimum/Average, Filter,
* Refer to “Specification data”.
** Optional ite m
*** High range IDOS - Low range IDOS (if applicable)
All product names are trademarks of their respective companies.
K335 Issue 3
[EN] English - 1
Safety
Before you use the instrument, make sure that you read
and understand all the related data. This includes: all local
safety procedures, the instructions for the UMM (if
applicable), and this publication.
WARNING
• Some liquid and gas mixtures are dangerous. This
includes mixtures that occur because of
contamination. Make sure that the instrument is
safe to use with the necessary media.
• It is dangerous to ignore the specified limits for the
instrument or to use the instrument when it is not in
its normal condition. Use the applicable protection
and obey all safety precautions.
• To prevent a dangerous release of pressure, isolate
and bleed the system before you disconnect a
pressure connection.
• Do not u se the instrumen t in locations w ith explosive
gas, vapor or dust. There is a risk of an explosion.
• DPI 802/802P only. To prevent electrical shocks or
damage to the instrument, do not connect more
than 30V between the terminals, or between the
terminals and the ground (earth).
Before you start an operation or procedure in this
publication, make sure that you have the necessary skills
(if necessary, with qualifications from an approved training
establishment). Follow good engineering practice at all
times.
Safety - Marks and symbols on the instrument
Complies with European
Union directives
Read the manualBattery
Ground (Earth) P1/P2 Identifies the pressure
ON/OFF
MWP
The maximum working pressure for the connector.
Example: 2 x FS (FS = Full scale pressure)
REFERENCE
The connector is a reference port for r eference pressure only. Refer
to “Specification data”.
The identification on e ach pressure connector includes the
type of thread (1/8 NPT, G1/8 ... ).
Warning - refer to the
manual
range connector
To start
To start - Location of items …
ItemDescription
1.❍On or off button.
2.
3.
4.
5.
6.
7.
8.Display. Refer to A3
9.
10.10a. IDOS pressure connector with identification marks.
11.Connection point for some of the optional
12.Battery compartment. Refer to B1.
13., 14., 15. DPI 802/802P only. Terminals to measure current, to
Left-hand soft-key. Selects the function above it on
■ ■
the display (Item 24). Example: Edit
Moves back one menu level.
ESC
Leaves a menu option.
Cancels the changes to a value.
Increases or decreases a value.
▲
▼
Highlights a different item.
Holds the data on the display. To continue, press the
HOLD
HOLD button again.
Shows the Select Task menu.
MENU
Selects or accepts an item or value.
OK
Selects [✓] or cancels [ ] a selection
Right-hand soft-key. Selects the function above it on
10c. PTFE vent filter or a reference port connector. Refer to
“Specification data”.
accessories. Refer to the datasheet.
supply 24V source, and to do switch tests.
A1A2
2 - [EN] English
K335 Issue 3
To start - Items on the display
ItemDescription
16.DPI 802/802P only. Task indication for the switch test.
17.DPI 802/802P only. The loop power supply is on.
18.The measured value satisfies one of the alarm
19.The data on the display is on hold. To continue, press
20.
21.Identifies the type of data and the measurement
22. ... 23.Identifies the settings applied to the input.
22. xxxx g The units and the type of sensor (If applicable)
23.Shows the settings applied to the measured value (If
24.A soft-key function. To select an available function,
25.The measured value or values applicable to the task
26.The Edit display to set up text labels ( ≤ 6 characters):
= switch closed
Task indication for the leak test.
Refer to: Select Task (Table 2/3)
Refer to: Select Task (Table 2/3)
conditions. Refer to: Settings (Table 4)
the HOLD button again.
Shows the battery level: 0 ... 100%.
range.
= Input= IDOS input
Refer to: Select Task (Table 2/3)
Refer to: Settings (Table 4)
OR a specified scale (x:y).
applicable).
= Filter
= Tare
press the soft-key below it. Example:
= Move left = Move right
selection.
x:yScaling (Table 4).
OK= Accept the new text label
Shift = Change the keys: 123ABC or -_+abc
= Add a space
BS= Back space (Delete character)
A3
= switch open
= Maximum
= Average
= Minimum
To start - Prepare the instrument
Before you use the instrument for the first time:
• Make sure that there is no damage to the instrument,
and that there are no missing items.
• Remove the plastic film that protects the display. Use
the tag (◗ ) in the top right-hand corner.
• Install the batteries (refer to B1). Then re-attach the
cover.
To start - Power on or off
To turn the instrument on or off, press ❍ (A1 - item [1]). The
instrument does a self test and then shows the applicable
data.
When the power is off, the last set of configuration options
stays in memory. Refer to “Maintenance”.
To start - Set up the basic operation
Use the Set Up menu to set up the basic operation of the
instrument.
Menu:
1
Select Tas k
(Table 2)(Table 1)[✓]/[ ]
23
▲
▼
Menu:
Set Up
45
▲
▼
If there is additional data for a menu option, select
Settings (■■) to see the values that are set up. If
necessary, adjust the values.
Table 1: Menu options - Set Up
Options
(If applicable)
Descript ion
DPI 802/802P only. To add a series resistor into the
mA circuit. You can then use this instrument
together with a HART® communicator to set up
and calibrate HA RT® devices.
To select and set up the backlight facility + timer.
Additional data: Select Settings (■ ■)
To select and set up the power off facility + timer.
Additional data: Select Settings (■■)
To show the battery level (%).
To set the display contrast (%).
▲ Increases %, ▼ decreases %
To set the time + date. The calibration facility uses
the date to give service and calibration messages.
To set the language option.
To calibrate the instrument.
Additional data: Refer to “Calibration”.
To select and show the applicable status data
(Software Build, Calibration Due date, Serial
Number, IDOS Information).
K335 Issue 3
[EN] English - 3