GE Dresser Series B3 Installation Supplement Manual

GE Oil & Gas
Dresser* Series B3 Meter with ES3 Electronic Temperature Compensator Circular Pulse Output Connector
Installation Supplement
2
Use and Limitations
This document provides recommendations where there is no established company procedure or practice.
Safety
The purchaser and user of this product is warned that compli­ance with the manufacturer’s instructions and procedures is required in order to avoid the hazards of leaking gas result­ing from improper installation, start-up or use of this prod­uct. The user is responsible to comply with all federal, state and local building and safety regulations. The manufacturer recommends that a qualifi ed technician install this product for safe and proper operation.
Refer to “Installation Operation and Maintenance: ES3” (IOM) for complete instructions. Consult Factory to obtain the IOM.
Receiving, Handling and Storage
Although of very rugged construction, reasonable care should be taken during handling and storage.
At Time of Delivery
1. Check the packing list to account for all items received
2. Inspect each item for damage
3. Record any visible damage or shortages on the delivery record
a. File a claim with the carrier if necessary b. Notify your Roots Meter supplier immediately
IMPORTANT NOTE
Do not attempt repairs or adjustments, as doing so may be a basis for voiding all claims for warranty.
The ES3 Electronic TC does not require lubrication.
1. Meter Installation
Refer to “Installation Supplement IS:B3” for Meter installation procedures.
Figure 1 - Label on ES3 Electronic TC
Figure 2 - Swipe magnet across the words “Roots ES3 Index” to change the screen displays
2.1 LCD Screen Displays
1. The default screen is either Compensated Volume or Non-Compensated Volume, depending on customer confi guration.
a. This parameter is the home/default screen. b. After a time out of approximately 30 seconds, the
home screen always will appear.
2. Repeat the swiping motion of the magnet across the words “Roots ES3 Index,” and the screens will appear in sequential order as shown in Table 1.
Note: Using the Dresser MeterWare Software, the screens are confi gured by checking and un-checking the parameter to be displayed. Depending on the ES3 confi guration, some screens may not appear.
ROOTS* ES3 Electronic Temperature Compensator (TC) Installation Procedures
WARNING
This equipment is designed to operate at temperatures between -40° F to 140° F. Prior to going on-site for installation or maintenance, make sure proper safety equipment is worn before handling the equipment and that you are properly dressed for the work site environment temperatures.
2. LCD Display
Scrolling through the screen displays and connecting to the ES3 Electronic TC requires use of the magnet. The magnet can be purchased as part of the Communications Kit, P/N 060542-000 or as an individual item, P/N 060541-000. Consult Factory for pricing.
Swipe the magnet across the words “Roots ES3 Index” as shown in Figures 1 - 2.
Note: the magnet will not change screen displays if swiped on another area of the label.
WARNING
If equipment is installed/serviced/maintained at elevated heights, ensure proper safe site work practices are in place to prevent fall and drop hazards.
WARNING
For installations in confi ned spaces, allow adequate room to safely handle product and equipment without causing bodily strain. Also verify proper ventilation is in place to maintain a breathable atmosphere.
Loading...