GE DPXH46GACC, DPXH46GAWW Specification

DPXH46GACC/WW—GE Profile™Extra-Large 5.7 Cu. Ft. Capacity Front-Load Dryer
Specification Revised 2/02
TM
Dryer Dimensions (in inches)
Exhaust Options:
Gas Dryer Electric Rating: 120V, 60Hz, 6A An individual properly-grounded branch circuit, with a three-prong grounding-type receptacle, protected by a 15 or 20 amp circuit breaker or a time-delay fuse is required.
Gas (BTU/HR): 22,000. Factory-equipped for natural gas. Tested for LP gas. LP gas supply requires a conversion kit. Check installation instructions for correct kit and have a qualified gas technician install a conversion kit. See dryer ducting information for proper installation.
Note: Dryer wall outlet must be located within 36" of service cord entry and accessible when dryer is mounted in position.
Installation Information: For complete information, see installation instructions packed with your dryer.
R
Listed by Underwriters Laboratories
For answers to your Monogram,® GE Profile™or GE appliance questions, visit our website at GEAppliances.com or call GE Answer Center®service, 800.626.2000.
REAR VIEW
26-7/8
3-3/4
1
36
Under
Counter
34-5/8"
3/16"
Gas Pipe Connection
Electric Connection
2-9/16
13-9/16
SIDE VIEW
25-3/4
47-1/2
4-3/4
Optional Vent Knockout
Door Open
90°
4-3/8
3/4
TM
Specification Revised 2/02
DPXH46GACC/WWGE Profile™Extra-Large 5.7 Cu. Ft. Capacity Front-Load Dryer
Undercounter Installation
• Accessory mounting kits are required for undercounter installation. To order, call 1-800-848-7722. Washer—Order Pub. No. 14-A037 Dryer—Order Pub. No. 14-A008
Stacked Installation
Brackets for stacking dryer over washer are included with the dryer.
Alcove or Closet Installation
If your dryer is approved for installation in an alcove or closet, it will be stated on a label on the dryer back.
The dryer MUST be exhausted to the outdoors.
Minimum clearances between dryer cabinet and adjacent walls or other surfaces are:
0" either side 3" front and rear
Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52".
Closet doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq. in. of open area equally distributed. If this closet contains both a washer and a dryer, doors must contain a minimum of 120 sq. in. of open area equally distributed.
The closet should be vented to the outdoors to prevent gas pocketing in case of a gas leak in the supply line.
No other fuel-burning appliance shall be installed in the same closet with the dryer.
Bathroom or Bedroom Installation
The dryer MUST be exhausted to the outdoors.
The installation must conform with the local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.
Minimum Clearances other than Alcove or Closet Installations
Minimum clearances to combustible surfaces:
0" both sides 3" rear
36"
25-3/4"
53-1/2"
Washer Top Sheet
Dryer Top Sheet
Countertop
14''
29''
56''-60''
Lip on All Sides
3/4" High x 3/4" Wide
Max.
70-5/8"
25-3/4"
26-3/4"
Free-Standing Installation
Undercounter Installation
Raised/Built-In Installation
Stacked Installation
For more information on venting kits and accessories, please call 1-800-GE-CARES.
Special Installation Requirements
For answers to your Monogram,® GE Profile™or GE appliance questions, visit our website at GEAppliances.com or call GE Answer Center
®
service, 800.626.2000.
R
Listed by Underwriters Laboratories