GE DPXH46EACC, DPXH46EAWW Specification

DPXH46EACC/WW—GE Extra-Large 5.7 Cu. Ft. Capacity Front-Load Dryer
Specification Revised 1/01
TM
Dryer Dimensions (in inches)
Exhaust Options:
Electric—4-way via rear, right, left and bottom.
Circuit Requirements:
Electric Dryer Rating:
120/240V, 3-wire, 5600W, 24A 120/208V, 3-wire, 4400W, 22A
Note: Dryer wall outlet must be located within 36" of service cord entry and accessible when dryer is mounted in position.
Installation Information: For complete information, see installation instructions packed with your dryer.
REAR VIEW
26-7/8
3-3/4
1
36
Under
Counter
34-5/8"
3/16"
Gas Pipe Connection
Electric Connection
2-9/16
13-9/16
SIDE VIEW
25-3/4
47-1/2
4-3/4
Optional Vent Knockout
Door Open
90°
4-3/8
3/4
For answers to your Monogram,
®
GE Profile Performance Series,
GE Profile™or GE appliance questions, call GE Answer Center®service, 800.626.2000.
R
Listed by Underwriters Laboratories
DPXH46EACC/WWGE Extra-Large 5.7 Cu. Ft. Capacity Front-Load Dryer
Specification Revised 1/01
TM
Undercounter Installation
• Accessory mounting kits are required for undercounter installation. To order, call 1-800-848-7722. Washer—Order Pub. No. 14-A037 Dryer—Order Pub. No. 14-A008
Stacked Installation
Brackets for stacking dryer over washer are included with the dryer.
Alcove or Closet Installation
If your dryer is approved for installation in an alcove or closet, it will be stated on a label on the dryer back.
The dryer MUST be exhausted to the outdoors.
Minimum clearances between dryer cabinet and adjacent walls or other surfaces are:
0" either side 3" front and rear
Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52".
Closet doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq. in. of open area equally distributed. If this closet contains both a washer and a dryer, doors must contain a minimum of 120 sq. in. of open area equally distributed.
The closet should be vented to the outdoors to prevent gas pocketing in case of a gas leak in the supply line.
No other fuel-burning appliance shall be installed in the same closet with the dryer.
Bathroom or Bedroom Installation
The dryer MUST be exhausted to the outdoors.
The installation must conform with the local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.
Minimum Clearances other than Alcove or Closet Installations
Minimum clearances to combustible surfaces:
0" both sides 3" rear
36"
25-3/4"
53-1/2"
Washer Top Sheet
Dryer Top Sheet
Countertop
14''
29''
56''-60''
Lip on All Sides
3/4" High x 3/4" Wide
Max.
70-5/8"
25-3/4"
26-3/4"
Free-Standing Installation
Undercounter Installation
Raised/Built-In Installation
Stacked Installation
For more information on venting kits and accessories, please call 1-800-GE-CARES.
Special Installation Requirements
For answers to your Monogram,
®
GE Profile Performance Series,
GE Profile™or GE appliance questions, call GE Answer Center®service, 800.626.2000.
R
Listed by Underwriters Laboratories