• Turn power off before inspection, installation or removal.
• Properly ground electrical enclosure.
RISK OF ELECTRIC SHOCK
• Follow all NEC and local codes.
• Use only UL approved wire for input/output connections.
Minimum size 18 AWG or 14 AWG for continuous runs.
RISQUES DE DÉCHARGES ÉLECTRIQUES
• Coupez l’alimentation avant d’’inspecter, installer ou déplacer le luminaire.
• Assurez-vous de correctement mettre à la terre le boîtier d’alimentation électrique.
RISQUES D’INCENDIE
• Respectez tous les codes NEC et codes locaux.
• N’utilisez que des ls approuvés par UL pour les entrées/sorties de
connexion. Taille minimum 18 AWG ou 14 AWG pour les rangées continues.
Installation Guide
Save These Instructions
Use only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer.
Prepare Electrical Wiring
Electrical Requirements
• The LED driver must be supplied with 120V for
DIXXXXXXX1VXX xtures, 277V for DIXXXXXXX2VXX
xtures, and 347V for DIXXXXXXX3VXX xtures,
50/60 Hz and connected to an individual properly
grounded branch circuit, protected by a 20 ampere
circuit breaker. Use min. 75°C supply conductor.
Grounding Instructions
• The grounding and bonding of the overall system shall
be done in accordance with National Electric Code
(NEC) Article 600 and local codes.
imagination at work
Page 2
Unit Installation
Cut the appropriate size hole into
1
ceiling tile (see table at right).
FixtureHole Size
4 in. round xture5 in. (126mm) diameter hole
6 in. round xture6½ in. (165mm) diameter hole
4 in. square xture5½ in. x 5½ in. (140mm x 140mm)
6 in. square xture7 in. x 7 in. (178mm x 178mm)
Slide hanger bars through
2
adjustable mounting brackets.
Adjust xture height to be
4
ush with ceiling and secure
by tightening both adjustable
mounting bracket wingnuts.
Option A: Mount xture by
3
attaching hanger bars to
T-Grid ceiling (BH3 SKU 94890).
Dust off any particles that may
5
have adhered to connection
points and heat sink during
installation process with a dry
cloth or compressed air. Twist
Infusion™ downlight module
into holder.
T-GridT-Grid
Option B: Mount xture with ½”
3
EMT conduit.
Note: Supplied by 3rd party.
Slide reector into the xture.
6
Verify reector trim is ush with
ceiling. Repeat Step 4 if trim is
not ush.
For wall wash reectors, position
reector so that light is directed
towards wall.
Page 3
Electrical Connections
THERMAL
PROTECTOR
277V
Black
WhiteCommon
Red
DRIVER
277V
Black
Violet
White
Black
Black
Neutral
347V Input
Common
RedLine
THERMAL
PROTECTOR
DRIVER
347V
347V TRANSFORMER
Connect the black (line) of the AC line to the black 120V, 277V,
or 347V wire. Connect the white (neutral) wires of the AC line
to the white wires using the provided 18-12 AWG push-in
connectors. Connect the green wire to the ground screw.
Optional: If using a 0-10V dimming controller, connect
matching-colored wires together.
Risk of damage: Make sure that supply connection, light
xture wiring, and dimming cables are connected to proper
driver inputs. Wrong connection may cause damage to the
product.
Must use UL approved conduit ttings for all enclosure
box connections to prevent wire cuts by sharp edges and
excessive strain on wiring.
0-10V dimming
controller (optional)
From
module
holder
Thermal
protector
AC line
0-10V Dimming Lighting Controller (optional)Wiring the Thermal Protector
THERMAL
PROTECTOR
Blue
Black
120V
WhiteCommon
120V
DRIVER
0-10V wiring diagram
Line (black)
Neutral (white)
Ground (green)
(1-10) + (violet)
(1-10) - (gray)
Line
Neutral
Ground
DRIVER
(0-10V) -
(0-10V) +
Make appropriate connections to the output wires of the
LED driver using twist-on wire connectors. Follow lighting
controller installation instructions.
NOTE: For 0-10V dimming SKUs.
Lutron Ecosystem Lighting Controller (optional)
Ecosystem Wiring Diagram
EcoSystem (purple)
EcoSystem (purple)
Line (black)
See Note
Neutral (white)
Ground (green)
Note: DL, for use with 3-wire uorescent control, (Lutron System)
E1
E2
L
DRIVER
DL
N
Page 4
Troubleshooting
SymptomSolution
Luminaire does not light• Check input voltage and check power supply input/output connections.
• Check circuit breaker.
• Check that the color of the supply side wires match the color of the wires they are
connected to.
• Check that the LED driver connector is fully engaged to the LED light engine connector.
• Check that the LED light engines are connected at the junction between the two
luminaires.
Luminaire is dim• Dimming wire connection shall be checked and if connection is not proper, reconnect it.
If wire is harmed, replace it with an intact one. Also check that dimming wires are not in
short circuit.
• Check that LED module is rmly seated in module holder and twisted in tightly.
Luminaire does not dim• Check dimming wire connection.
Through Wiring
Lumen LevelMaximum number of xtures
1000, 1500, 2000 lumen30
3000, 4000 lumen20
15A Circuit
Minimum Spacing Requirements
a) Center to center of adjacent luminaries24”
(b) Top of luminaire to overhead building member2.5”
(c) Luminaire center to side of building member12”
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This Class
[A] RFLD complies with the Canadian standard ICES-003. Ce DEFR de la classe [A] est conforme á la NMB-003 du Canada.
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to
cause harmful interference in which case the user will be required to correct the interference at his own expense.
Fixture intended for commercial use only. Use only in non-insulated applications.
GE Lighting • 1-888-MY-GE-LED (1-888-69-43-533) • www.gelighting.com