GE
Lighting
LuminationTM LED Luminaire
(DI Series)
BEFORE YOU BEGIN
Read these instructions completely and carefully.
WARNING/AVERTISSEMENT
RISK OF ELECTRIC SHOCK
• Turn power off before inspection, installation or removal.
• Properly ground electrical enclosure.
RISK OF ELECTRIC SHOCK
• Follow all NEC and local codes.
• Use only UL approved wire for input/output connections.
Minimum size 18 AWG or 14 AWG for continuous runs.
RISQUES DE DÉCHARGES ÉLECTRIQUES
• Coupez l’alimentation avant d’’inspecter, installer ou déplacer le luminaire.
• Assurez-vous de correctement mettre à la terre le boîtier d’alimentation électrique.
RISQUES D’INCENDIE
• Respectez tous les codes NEC et codes locaux.
• N’utilisez que des ls approuvés par UL pour les entrées/sorties de
connexion. Taille minimum 18 AWG ou 14 AWG pour les rangées continues.
Installation Guide
Save These Instructions
Use only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer.
Prepare Electrical Wiring
Electrical Requirements
• The LED driver must be supplied with 120V for
DIXXXXXXX1VXX xtures, 277V for DIXXXXXXX2VXX
xtures, and 347V for DIXXXXXXX3VXX xtures,
50/60 Hz and connected to an individual properly
grounded branch circuit, protected by a 20 ampere
circuit breaker. Use min. 75°C supply conductor.
Grounding Instructions
• The grounding and bonding of the overall system shall
be done in accordance with National Electric Code
(NEC) Article 600 and local codes.
imagination at work
Unit Installation
Cut the appropriate size hole into
1
ceiling tile (see table at right).
Fixture Hole Size
4 in. round xture 5 in. (126mm) diameter hole
6 in. round xture 6½ in. (165mm) diameter hole
4 in. square xture 5½ in. x 5½ in. (140mm x 140mm)
6 in. square xture 7 in. x 7 in. (178mm x 178mm)
Slide hanger bars through
2
adjustable mounting brackets.
Adjust xture height to be
4
ush with ceiling and secure
by tightening both adjustable
mounting bracket wingnuts.
Option A: Mount xture by
3
attaching hanger bars to
T-Grid ceiling (BH3 SKU 94890).
Dust off any particles that may
5
have adhered to connection
points and heat sink during
installation process with a dry
cloth or compressed air. Twist
Infusion™ downlight module
into holder.
T-Grid T-Grid
Option B: Mount xture with ½”
3
EMT conduit.
Note: Supplied by 3rd party.
Slide reector into the xture.
6
Verify reector trim is ush with
ceiling. Repeat Step 4 if trim is
not ush.
For wall wash reectors, position
reector so that light is directed
towards wall.