GE DGE Data Sheet

DGE DURAGLOW ® 400 LUMINAIRE NUVATION ™ Electronic Ballast
High Bay, Open – Optical Sliding Disconnect Series
APPLICATIONS
•  For over 20 ft. (6 meter) applications.  Assembly, maintenance or storage areas,       hangers,  recreation centers, and other high bay applications.
SPECIFICATION FEATURES:
•     1598 Listed
Suitable for Damp Location
•  Open, ventilated optical assembly
•  Unique optical sliding disconnect
•  55° C ambient, standard
•  ALGLAS ® nish on faceted reector.
•  Nuvation ™ electronic ballast:
• Dimming Option — dims lamp to 50% of rated       lamp wattage.
• Two piece heavy-duty die cast aluminum housing
  •  Integral optical mounting design for GELS       “Sliding Disconnect”
   • Attractive round ballast housing design with       white polyester paint nish
ORDERING NUMBER LOGIC
DGE
PRODUCT IDENT
XXX DGE =
Duraglow 
400
Luminaire 
Disconnect
optical 
with
NnVation  electronic  ballast
PHOTOMETRIC SELECTION TABLE
V7 OPTICAL - Open & Ventilated 17 in. Reector
Light Spacing Socket Photometric Optical Photometry Wattage Source Criteria Position Curve Code Code
320, 350, 400 320, 350, 400 320, 350, 400 320, 350, 400 320, 350, 400 320, 350, 400
V2 OPTICAL - Open & Ventilated 22 in. Reector
Light Spacing Socket Photometric Optical Photometry Wattage Source Criteria Position Curve Code Code
400 MH,P 0.7 7 174978 V2 ES 400 MH,P 0.9 11 179165 V2 EX
W
COLOR
X W = White
Polyester  Powder
40
WATTAGE
XX
25 = 250 32 = 320 35 = 350 40 = 400
MH,P 1.1 11 174980 V7 EX
MH,P 1.3 9 174981 V7 EU MH,P 1.6 5 177098 V7 EQ MH(Coated),P 1.2 11 175933 V7 EX MH(Coated),P 1.5 9 175320 V7 EU MH(Coated),P 1.9 5 175930 V7 EQ
N
LIGHT SOURCE
X N =
Ballast will  operate 
Pulse
Start or  Ceramic  Metal  Halide  Lamps
Note:
Lamp is  vertical  base up.   Lamp is 
not
included.
G
VOLTAGE
X G = 208-277
Discrete  Voltages  must be  specied 
when
ordering  cord & plug  assemblies:
2 = 208 3 = 240 4 = 277
E
BALLAST TYPE
X E=
Electronic
C= Dimming
V7
OPTICAL CODE
XX V7 =
Open and  ventilated 
17-in.
Reector
V2 =
Open and  ventilated 
22-in.
Reector
Note: Do not
use open  opticals  with lamps  specied  for use in  enclosed  opticals only
EX
PHOTOMETRY CODE
XX XX = Select
Code
Below
  • Integral air gap between optical       mounting and ballast for optimum       temperature control and thermal       management
  • Slide-on mounting box adaptor with    3/4-in pendant and thru feed capability     for ease of installation and mounting.
•  External wattage selection port for
   selection of 250, 320, 350 & 400 watt
choices.
•  Safety chain provisions
•  Mogul base socket – E39 standard
•  Shipped as components: Ballast, Optical  Magnapack available for ballast.
11
MOUNTING CODE
XX
11= Pendant Slide on Box 15 = Prewire  with Loop, Cord and Plug part “Power  
Hook”. (Order Receptacle/Hook Box separately)
Discrete Voltages must be specied when ordering   cord & plug assemblies below: 31 = Prewired with Hook, 3 ft. (0.9 meters) #16/3 Cord     and NEMA PLUG 33 = Prewired with Loop, 3 ft. (0.9 meters) #16/3 Cord     and NEMA PLUG (Order Locking Receptacle
Separately, if required)
MODULAR PREWIRE 41 = ACS with 3 ft (.9 meter) cord & Hook 69 = ACS with 6 ft (1.8 meter) cord & Hook 43 = ACS with 3 ft (.9 meter) cord & Loop 70 = ACS with 6 ft (1.8 meter) cord & Loop
PLUG-N-GO 51 = Plug-N-Go with 3 ft. (0.9 meter) Cord & Hook 71 = Plug-N-Go with 6 ft. (1.8meter) Cord & Hook 53 = Plug-N-Go with 3 ft. (0.9 meter) Cord & Loop 72 = Plug-N-Go with 6 ft. (1.8 meter) Cord & Loop
Note: ACS = Flex 3+ Plug-N-Go = FSC Series
Exclusionary base socket is available for use with Metal Halide lamps in open  xtures to comply with NEC 2005 regulations (GELS “S” Option). Customer should consult or review local electrical codes for compliance.
All Electronic devices are susceptible to transient voltage spikes. For facilities  where the lighting circuits are not protected from transient voltage spikes  a  (TVSS)  Transient  Voltage  Surge  Suppression  system  is  recommended.  To protect the NuVation  ballast a T VS protection system  must be able  to  suppress a 3000V ring wave as described in ANSI/IEEE C62.41 B1.
X
OPTIONS
X
Q = Automatic  switched quartz S = Exclusionary  mogul base socket for  MH open xtures
I-12/2008
GE Lighting Solutions 1-888-MY-GE-LED www.gelightingsolutions.com
1 - 8 8 8 - 6 9 - 4 3 - 5 3 3
DGE DURAGLOW
NUVATION
® 400 LUMINAIRE
Electronic Ballast
High Bay, Open – Optical Sliding Disconnect Series
DIMENSIONS
When optical assembly contains a quartz socket an additional 
1.125 inches (29mm) must be added to the overall height due to  double stack disconnect.
NOTES
See explanation on “Optical Flexibility” Page I-4. See References.
REFERENCES
See Page I-104 for start of Accessories. See Page I-117 for Component Ordering Logic. See Page I-129 for Explanation of Options and Other Terms Used.
3/4 in. NPSC Thread
FIXTURE DIMENSIONS
15.00 in. Dia. (381mm)
Fixture Height
V7 - 30.00 in.
(762mm)
V2 - 30.187 in.
(767mm)
DATA
Approximate Net Weight lbs kgs Ballast and Optical 16 - 31 7 - 14
BALLAST DATA
*  13% Improvement in Pulse Start Metal Halide lamp lumen maintenance vs. magnetic. *   6% improvement in Ceramic Metal Halide lamp lumen maintenance vs. magnetic. *   50% lower ballast losses than typical CWA magnetic HID ballast. *   Lamp wattage regulation of +/-2% change for +/-10% change in line voltage. *   Ballast is rated for use with voltage range between 208 and 277 with +/-10% line voltage tolerance, 50/60 Hz, and will 
automatically sense voltage within specied range. *   Ballast input current total harmonic distortion (THD) of less than 15% when operated at nominal line voltage. *   Ballast is thermally protected to shut o when operating temperatures are   above unacceptable levels for the ballast safe and reliable operation. *   Ballast has an end-of-lamp-life detection and shutdown circuit.
*  The ballast shall have a minimum starting temperature of –20 degrees F    and maximum operating ambient of 55 degrees C..
*   Ballast is capable of operating pulse start metal halide or ceramic metal halide lamp types. *   Five-Year Fixture Failure Warranty. *   Meets requirements of FCC rules and regulations, Title 47 CFR part 18 for nonconsumer equipment.
Dimming Ballast
*   The ballast is supplied with a violet (+) and gray (-) wire for dimming control connections. *   Ballast dims to fty percent of rated lamp wattage. *   Dimming voltage is  0-10V where 10V is high wattage and 0 is fty percent of rated lamp wattage. *   Ballast operates the lamp at high wattage for 15 minutes at start up. *   Ballast operates lamp at high wattage for fteen minutes after operating in dim mode for twenty-four hours.
V7 - 17.13 in. Dia. (434mm) V2 - 22.80 in. Dia. (579mm)
INPUT WATTAGE TABLE
Lamp Line Input
Wattage Voltage Watts
400 277 428 400 240 432 400 208 435 350 277 377 350 240 380 350 208 383 320 277 346 320 240 347 320 208 349 250 277 276 250 240 272 250 208 271
® Registered Trademark of General Electric Company
GE Lighting Solutions 1-888-MY-GE-LED www.gelightingsolutions.com
1 - 8 8 8 - 6 9 - 4 3 - 5 3 3
TM
 Trademark  of General  Electric Company
Data subject  to  change  without notice
2008/I-13
Loading...