GE DCVH660GHBB, DCVH660GHGG, DCVH660GHWW, DCVH660GHMR, DCVH660GHMS Dimensions And Installation Information

For answers to your Monogram,® GE Profile™ or GE® appliance questions, visit our website at ge.com or call GE Answer Center® service,
800.626.2000.
Specification Revised 10/07
360464
Listed by Underwriters Laboratories
Dimensions and Installation Information (in inches)
Exhaust Options: 3-way via rear, left, and bottom.
Circuit Requirements: An individual, properly grounded
branch circuit, protected by a 30-amp circuit breaker or a time-delay fuse, is required.
Note: Dryer wall outlet must be located within 36” of service cord entry and accessible when dryer is mounted in position.
Installation Information: For complete information, see installation instructions packed with your dryer.
27
1-5/8
41-1/2
31-1/8
5-1/2
3-3/4
Gas Dryer Rating
120V
60Hz, 6A
DCVH660GH
GE® 7.0 Cu. Ft. Super Capacity Gas Dryer
For answers to your Monogram,® GE Profile™ or GE® appliance questions, visit our website at ge.com or call GE Answer Center® service,
800.626.2000.
Special Installation Requirements:
Stacked Installation:
• Brackets for stacking dryer over washer are included with the washer.
Alcove or Closet Installation:
• If your dryer is approved for installation in an alcove or closet, it will be stated on a label on the dryer back.
• The dryer MUST be exhausted to the outside.
• Minimum clearances between dryer cabinet and adjacent walls or other surfaces are: 0" either side, 3" front and rear
• Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52".
• Closet doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq. in. of open area equally distributed. If this closet contains both a washer and a dryer, doors must contain a minimum of 120 sq. in. of open area equally distributed.
• No other fuel-burning appliance shall be installed in the same closet with a gas dryer.
Bathroom or Bedroom Installation:
• The dryer MUST be exhausted to the outdoors.
• The installation must conform with the local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.
Minimum Clearance other than Alcove or Closet Installations:
• Minimum clearances to combustible surfaces 0" both sides, 3" rear.
For more information on venting kits and accessories, please call 1-800-GE-CARES.
Stacked Dimensions (in inches)
80-1/8
27
10-3/8
27
28-3/4
Pedestal Dimensions (in inches)
SBSD227FWW - white SBSD227FGG - granite
This optional 13-3/8" pedestal raises the door opening and height of the washer or dryer.
Listed by Underwriters Laboratories
Specification Revised 10/07
360464
DCVH660GH
GE® 7.0 Cu. Ft. Super Capacity Gas Dryer