GE DBVH512GFWW, DBVHB12GFGG Dimensions And Installation Information

DBVH512GF
GE®7.0Cu. Ft.Super Capacity Frontload Gas Dryer
Dimensions and Installation Information (in inches)
Gas Dryer Rating
120V 60Hz, 6A
Exhaust Options: B-way via rear, left, and bottom. Circuit Requirements: An individual, properly grounded
branch circuit, protected by a 30-amp circuit breaker or a time-delay fuse, is required.
Note: Dryer wall outlet must be located within 36" of service cord entry and accessible when dryer is mounted in position.
Installation Information: For complete information, see installation instructions packed with your dryer.
, 27
°:!!
31-1/8
1-5/8
t
41-1/2
For answers to your Monogram,®GE Profile TM or GE® appliance questions, visit our website at ge.com or call GEAnswer Center ®service,
800.626.2000.
_ imagination atwork
Listedby
Underwriters Laboratories
Specification Revised 3/06 360456
DBVH512GF
GE®7.0Cu. Ft.Super Capacity Frontload Gas Dryer
Special Installation Requirements: Stacked Installation:
Bracketsfor stacking dryer over washer are included with the washer. Alcove or Closet Installation:
If your dryer is approved for installation in an alcove or closet, it will be stated on a label on the dryer back.
The dryer MUSTbe exhausted to the outside.
Minimum clearances between dryer cabinet and adjacent walls or other surfaces are: 0"either side,3" front and rear
Minimum vertical spacefrom floor to overhead cabinets, ceilings,etc. is 52".
Closetdoors must beIouvered or otherwise ventilated and must contain a minimum of 60sq. in.of open area equally distributed. If this closet contains both a washer and a dryer, doors must contain a minimum of 120sq. in.of open area equally distributed.
No other fuel-burning appliance shall be installed inthe same closet with a gas dryer.
Bathroom or Bedroom Installation:
The dryer MUSTbe exhausted to the outdoors.
The installation must conform with the local codes, or in the absence of local codes, with the National FuelGas Code,ANSIZ223.
Minimum Clearance other than Alcove or Closet Installations:
Minimum clearances to combustible surfaces 0" both sides,3" rear,
For more information on venting kits and accessories, please call 1-800-GE-CARES.
For answers to your ivionogram2 GEProfild" or GE® appliance questions, visit our website at ge.com or call GEAnswer Center ®service,
800.626,2000.
Stacked Dimensions (in inches)
Pedestal Dimensions (ininches) SBSD227FWW- white SBSD227FGG- granite
This optional 13-3/8" pedestal
raisesthe door opening and height of the washer or dryer.
13-3/8
_1_28.3/4 /
imagination at work
Listedby
Underwriters Laboratories
Specification Revised 3106 360456