GE CT9800SH4SS, JK3800DH3BB, JK3800DH3WW, JK3800DH4BB, JK3800DH4WW Installation Guide

...
Installation Instructions
pp
27” & 30” Electric Built-In Wall Ovens
Questions? Call 1.800.GE.CARES (1.800.432.2737) or visit www.GEAppliances.com
In Canada, call 1.800.561.3344 or visit www.GEAppliances.ca
BEFORE YOU BEGIN
Read these instructions completely and carefully.
,03257$17³ Save these instructions
for local inspector’s use.
,03257$17³ Observe all governing
codes and ordinances.
ATTENTION INSTALLER: All electric wall ovens must be hard-wired (direct-wired) into an
approved junction box. A plug and receptacle is NOT permitted on these products.
FOR YOUR SAFETY:
WARNING
lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
Be sure the oven is securely installed in a cabinet that is firmly attached to the house structure. Weight on the oven door could cause the oven to tip and result in injury. Never allow anyone to climb, sit, stand or hang on the oven door.
Make sure the wall coverings, counters and cabinets around the oven can withstand the heat (up to 200°F [93.3°C]) generated by the oven.
:
Before beginning the installation, switch power off at the service panel and
Note to Consumer – Keep these instructions for future reference.
Skill level – Installation of this appliance requires a qualified installer or electrician.
• Proper installation is the responsibility of the installer.
• Product failure due to improper installation is not covered under Warranty.
• Product is for indoor use only.
DESIGN INFORMATION
SINGLE OVEN INSTALLATIONS
The single oven may be installed in a cabinet alone or above a warming drawer. The single oven may also be installed below a countertop or below specified cooktops. See the label on top of the oven for approved models.
DOUBLE OVEN INSTALLATIONS
A double oven may be installed in a cabinet alone or above a warming drawer. See the label on top of the oven for approved models.
IMPORTANT: Always refer to individual installation instructions packed with each product for specific requirements.
PREPARE THE OPENING
2
NOTE: If the cabinet does not have a solid bottom, two
braces or runners must be installed to support the weight of the oven. For single ovens, the runners and braces must support 200 lbs (91 kg). For double ovens, the runners and braces must support 375 lbs. (170 kg).
NOTE: If marks, blemishes or the cutout opening are visible above the installed oven, it may be necessary to add wood shims under the runners and front trim until the marks or opening are covered.
NOTE: If the cabinet does not have a front frame and the sides are less than ¾” (1.9 cm) thick, shim both sides equally to establish the cutout width.
Suitable Bracing to Su
ort
2" x 4" (5 cm x 10 cm)
or Equivalent Runners Level
with Bottom of Cutout
and Flush with Sides of Cutout
C
L
MATERIALS YOU MAY NEED
Junction Box Wire Nuts Strain Relief Clamp for 1/2” Conduit 36” (91 cm) of String
1
REMOVE PACKAGING MATERIALS
Failure to remove packaging materials could result in damage to the appliance. Remove all packing parts from oven, racks and heating elements. Remove protective film and labels on the outer door and control panel. Also, remove plastic on trims and panel, all tape around the oven and any shipping screws securing the oven to the base pad. Open oven door and remove literature pack and oven racks. Remove the bottom trim from the top of the oven. It will be installed at the end of the installation process. The trim is wrapped separately and taped to the top of the unit. Remove pedestal rails from seperate box and set aside (30” Double Wall Ovens Only).
TOOLS YOU MAY NEED
1/8” Drill Bit and Electric or Hand Drill Phillips Screwdriver Wire Strippers 7/16” Nut Driver T20 Screwdriver (hinge bracket) 1/4” Nut Driver
2 A
CUTOUT FOR SINGLE OVENS IN WALL CABINET
NOTE: If the cabinet does not have a front frame and the sides are less than ¾” (1.9 cm) thick, shim
both sides equally to establish the cutout width.
These ovens are not approved for stackable installations.
H
Junction Box Location (junction box may be located in adjacent cabinet)
B
2 B
CUTOUT FOR SINGLE OVENS – UNDER COUNTER
NOTE: These ovens are only approved to be installed under the specific models as labeled on the unit.
Opening Between Inside Walls Must be at Least 28-1/2” (72.4 cm) Wide
E
Side-by-Side Installations
Install two ovens in separate cutouts.
Center Line Center Line
Cutout – observe all dimensions and requirements.
30.5” (77.5 cm) 30” models
27” (68.58 cm)
27” models
Cutout – observe all dimensions and requirements.
2” (5.1 cm) Min.
22” (55.9 cm) Min. to Bottom of Junction Box
Cutout Depth 23-1/2” (59.7 cm) Min.
Note: Allow 1/4” (0.64 cm) clearances from side edges of oven door.
D
F G
A
Dimension Dimension Description 27” Single Oven 30” Single Oven A Cabinet Width 27” (68.6 cm) 30” (76.2 cm) B Cutout Width 25” (63.5 cm) min. 28
25 C Cutout Height 27
28
1
ø
” (64.1 cm) max. 28
4
5
ø
” (70.2 cm) min. 27
8
1
ø
” (71.4 cm) max. 27
8
D Overlap of Oven Over 1” (2.5 cm) Side Edges of Cutout
1
ø
” (72.4 cm) min.
2
5
ø
” (72.7 cm) max.
8
1
ø
” (69.2 cm) min.
4
5
ø
” (69.4 cm) max.
16 11
ø
” (1.75 cm)
16
E Clearance to 23” (58.4 cm) min. 23” (58.4 cm) min. Adjacent Corners,
Drawers, Walls, etc., When Door Is Open
F Overlap of Oven 1” (2.5 cm) min. 1” (2.5 cm) min.
Top of Cutout (1 G Overlap of Oven 1” (2.5 cm) min. 1
Bottom of Cutout H Junction Box Location 8
right side only right side only
3
ø
” (22.2 cm) max. 9
4
1
ø
” (3.2 cm) for PT9050)
4
1
ø
” (3.2 cm)
4
1
ø
” (24.1 cm) max.
2
C
Recommended Cutout Location from Floor 32-1/2” (82.6 cm)
Side-by-Side Installations
Install two ovens in separate cutouts.
Center Line Center Line
30.5” (77.5 cm) 30” models
27” (68.58 cm) 27” models
Cooktop
Cutout – observe all dimensions and requirements.
Cutout – observe all dimensions and requirements.
2” (5.1 cm) Min.
NOTE: One cooktop may be centered over either oven in the side-by-side installation.
Dimension Dimension Description 27” Single Oven 30” Single Oven A Cabinet Width 25” (63.5 cm) min. 28
25 B Cutout Height 27
28
1
ø
” (64.1 cm) max. 28
4
5
ø
” (70.2 cm) min. 27
8
1
ø
” (71.4 cm) max. 27
8
C Unit Overlap Top 1” (2.5 cm) 1” (2.5 cm) (1
D Unit Overlap Bottom 1” (2.5 cm) 1 E Unit Overlap Side Edges 1” (2.5 cm) F Junction Box Location 8
right side only right side only
3
ø
” (22.2 cm) max. 9
4
1
ø
” (72.4 cm) min.
2
5
ø
” (72.7 cm) max.
8
1
ø
” (69.2 cm) min.
4
5
ø
” (69.4 cm) max.
16
1
ø
” (3.2 cm) for PT9050)
4
1
ø
” (3.2 cm)
4
11
ø
” (1.75 cm)
16
1
ø
” (24.1 cm) max.
2
Continue to Section 4.
2 C
CUTOUT FOR DOUBLE OVENS
(2 THERMAL OVENS)
NOTE: If the cabinet does not have a front frame and the sides are less than ¾” (1.9 cm) thick, shim
both sides equally to establish the cutout width.
H
Junction Box Location (junction box may be located in adjacent cabinet)
B
F
D
J
C
G
2 D
CUTOUT FOR DOUBLE OVENS (with Upper Microwave Oven)
NOTE: If the cabinet does not have a front frame and the sides are less than ¾” (1.9 cm) thick, shim
both sides equally to establish the cutout width.
E
Cutout Depth 23-1/2” (59.7 cm) Min.
A
Dim. Description 27” Double Oven 30” Double Oven with
Pedestal
A Cabinet Width 27” (68.6 cm) 30” (76.2 cm) 30” (76.2 cm)
1
ø
” (72.4 cm) min.
B Cutout Width 25” (63.5 cm) min.
C Cutout Height
D Overlap of Oven
Over Side Edges
of Cutout
E
F Overlap of Oven
G Overlap of Oven
H Junction Box
K Recommended
Clearance to
Adjacent Corners,
Drawers, Walls, etc.,
When Door Is Open
Top of Cutout
Bottom of Cutout
Location
J Height to Bottom
of Junction Box
Cutout Location
from Floor
1
25
ø
” (64.1 cm) max.
4
11
49
ø
” (126.2 cm) min.
16
1
50
ø
” (127.3 cm) max.
8
1” (2.5 cm)
23” (58.4 cm) min. 23” (58.4 cm) min. 23” (58.4 cm) min.
1” (2.5 cm) min. 1” (2.5 cm) min.
1” (2.5 cm) min. 1
3
8
ø
” (22.2 cm) max.
4
right side only 44” (111.8 cm) 47” (119.4 cm) 47” (119.4 cm)
1
13
ø
” (33.7 cm) 12” (30.5 cm) 12” (30.5 cm)
4
28
2
5
28
ø
” (72.7 cm) max.
8
13
ø
” (131.6 cm) min.
51
16
15
51
ø
” (131.9 cm) max.
16
11
ø
” (1.75 cm)
16
1
(1
ø
” (3.2 cm) for PT9550)
4
1
ø
” (3.2 cm) 1
4
1
9
ø
” (24.1 cm) max.
2
right side only
30” Double Oven without Pedestal
1
28
ø
” (72.4 cm) min.
2
5
28
ø
” (72.7 cm) max.
8
50 ¼” (127.64cm)
11
ø
” (1.75 cm)
16
1” (2.5 cm) min.
1
(1
ø
” (3.2 cm) for PT9550)
4
1
ø
” (3.2 cm)
4
1
9
ø
” (24.1 cm) max.
2
right side only
K
Dim. Description 27” Oven
with Microwave
A Cabinet Width 27” (68.6 cm) 30” (76.2 cm) B Cutout Width 25” (63.5 cm) min.
C Cutout Height
D Overlap of Oven Over Side Edges
E Clearance to Adjacent Corners,
Drawers, Walls, etc., When Door
of Cutout
Is Open
1
25
ø
” (64.1 cm) max.
4
1
41
ø
” (104.5 cm) min.
8
1
41
ø
” (104.8 cm) max.
4
1” (2.5 cm)
23” (58.4 cm) min. 23” (58.4 cm)
F Overlap of Oven Top of Cutout 1” (2.5 cm) min. 1” (2.5 cm) min. G Overlap of Oven Bottom of Cutout 1” (2.5 cm) min. 1 H Junction Box Location 8
3
ø
” (22.2 cm) max.
4
right side only
Continue to Section 4.
30” Oven
with Microwave
1
ø
” (72.4 cm) min.
28
2
5
28
ø
” (72.7 cm) max.
8
3
ø
” (107.2 cm) min.
42
16
1
42
ø
” (107.3 cm) max.
4
11
ø
” (1.75 cm)
16
1
ø
” (3.2 cm)
4
1
9
ø
” (24.1 cm) max.
2
right side only
Continue to Section 3 for DWO with Pedestal. Otherwise, continue to Section 4.
31-11044 08-16 GEA
2 E
For double oven with microwave or Advantium upper ovens. Secure a wooden cleat to side of cabinet so that the upper oven can be secured to the cleat with provided screws
27” Cabinet requirements
• No shims (or cleats) required when cabinet is in minimum
• If cabinet is at maximum width condition, add wood
30” Cabinet requirements
• No shims (or cleats) required when cabinet is in minimum
• If cabinet is at maximum width condition, fix the wood
SECURING UPPER MICROWAVE/ADVANTIUM OVEN TO CABINET
width condition.
shims to bring cabinet to minimum condition.
width condition.
cleats as shown in illustration.
6.375”
27.5”
Cleat locations on 30” cabinet
with maximum cutout condition
Wood Cleats
1.5”
3.0”
PEDESTAL RAIL INSTALLATION (30” DOUBLE OVENS ONLY)
3
A. Place one pedestal rail on each cabinet runner or centered on opposite side of solid cabinet bottom
flush with side of cabinet opening. Locate each rail so that front of rail is behind front cabinet opening.
B. Drill pilot holes and attach rails to runner or bottom of cabinet with provided hardware.
2 F
NOTE: Install the oven only with specific models listed on the label located on top of the oven. NOTE: Additional clearances between cutouts may be required. Check to be sure the oven supports
above the Warming Drawer location do not obstruct the required interior depth and height. When installing a Warming Drawer below a single or double oven, a separate 120V, 60 HZ, properly
grounded receptacle must be installed. Refer to installation instructions packed with the Warming Drawer for specific installation requirements.
CUTOUT FOR INSTALLATION OVER A WARMING DRAWER
Anti-Tip Block Against Rear Wall Per Warming Drawer Requirement
2" (5.1 cm) Min.
Per Warming Drawer Requirement
4 A
NOTE: Door removal is not a requirement for installation of the product but is an added convenience. To remove the door: A. Open the oven door as far as it will go. B. Remove hinge bracket from front frame and set aside. The hinge bracket must
C. Push both hinge locks down toward the door frame to the unlocked position.
D. Place hands on both sides of the door and close the oven door to the removal
E. Lift the door up and out until the hinge arms clear the slots.
DOOR REMOVAL (RECOMMENDED)
Hinge Bracket
be replaced for proper door functionality when door is reinstalled.
This may require a flat-blade screwdriver. DO NOT LIFT THE DOOR BY THE
HANDLE!
position (approximately 1”–2” [2.5 cm–5.1 cm] from the closed position).
NOTE: The oven door is very heavy. Be sure you have a firm grip before lifting the oven door off the hinges. Use caution once the door is removed. Do not lay the door on its handle. This could cause dents or scratches.
Hinge Unlocked Position
Continue to Section 4
Hinge Slot
Hinge Arm
Hinge Clears Slot
4 B
SHIPPING SCREWS REMOVAL (FOR 30” DOUBLE WALL
OVEN WITH UPPER MICROWAVE OVEN ONLY)
Shipping screws must be removed as shown in illustration. You will need a 1/4” Nut Driver.
Remove Shipping Screws From Both Sides
ELECTRICAL REQUIREMENTS
5
WARNING WARNING WARNING
beginning installation.
WARNING
in an electrical hazard or fire. Use only connectors designed for joining copper to aluminum and follow the manufacturer’s recommended procedure closely.
We recommend you have the electrical wiring and hookup of your appliance connected by a qualified electrician. After installation, have the electrician show you how to disconnect power from the appliance.
You must use a single-phase, 120/208 VAC or 120/240 VAC, 60 Hertz electrical system. If you connect to aluminum wiring, properly installed connectors approved for use with aluminum wiring must be used.
Effective January 1, 1996, the National Elec a four-conductor connection to an electric oven. When installing an electric oven in new construction, a mobile home, recreational vehicle or an area where local codes prohibit grounding through the neutral conductor, refer to the section on four-conductor branch circuit connections.
Check with your local utilities for electrical codes which apply in your area. Failure to wire your oven according to governing codes could result in a hazardous condition. If there are no local codes, your oven must be wired and fused to meet the National Electrical Code, NFPA No. 70 – latest edition, available from the National Fire Protection Association.
:
This appliance must be properly grounded.
:
To prevent fire or shock, do not use an extension cord with this appliance.
:
To prevent shock, remove house fuse or open circuit breaker before
:
Improper connection of aluminum house wiring to copper leads can result
trical Code requires that new construction (not existing) utilize
ELECTRICAL REQUIREMENTS (CONT.)
5
This appliance must be supplied with the proper voltage and frequency and connected to an individual, properly grounded branch circuit, protected by a circuit breaker or fuse. See the rating plate located on the oven frame to determine the rating of the product.
Rating plate is located on the oven side trim.
Use the chart below to determine the minimum recommended dedicated circuit protection:
Recommended KW Rating KW Rating Circuit Size 240V 208V (Dedicated)
.: .: $PS
4.9 KW–7.2 KW 4.2 KW–6.2 KW 30 Amp
7.3 KW–9.6 KW 6.3 KW–8.3 KW 40 Amp
9.7 KW–12.0 KW 8.4 KW–10.4 KW 50 Amp
DO NOT shorten the flexible conduit. The conduit strain relief clamp must be securely attached to the junction box and the flexible conduit must be securely attached to the clamp. If the flexible conduit will not fit within the clamp, do not install the oven until a clamp of the proper size is obtained.
The 3 power leads supplied with this appliance are suitable for connection to heavier gauge household wiring. The insulation of these 3 leads is rated for temperatures much higher than the temperature rating of the household wiring. The current-carrying capacity of the conductor is governed by the wire gauge and the temperature rating of the insulation around the wire.
Loading...
+ 11 hidden pages