GE C2S985SET7SS, C2S985SET8SS, C2S985SET9SS Installation Guide

Installation Instructions Range
Questions? Call 1.800.GE.CARES (1.800.432.2737) or visit www.GEAppliances.com
IN THE COMMONWEALTH OF MASSACHUSETTS
This product must be installed by a licensed
plumber or gas fitter.
WARNING
FIRE OR EXPLOSION HAZARD
If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or death.
Installation must be performed by a qualified installer.
Read these instructions completely and carefully. Installation of this range must conform with
local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/ NFPA.54, latest edition. In Canada, installation must conform with the current Natural Gas Installation Code, CAN/CGA-B149.1 or the current Propane Installation Code, CAN/CGA-B149.2, and with local codes where applicable. This range has been design-certified by CSA International according to ANSI Z21.1, latest edition and Canadian Gas Association according to CAN/ CGA-1.1 latest edition.
When using ball type gas shut-off valves, they
shall be the T-handle type.
A flexible gas connector, when used, must not
exceed 3 feet.
When installing a gas appliance the use of old flexible connectors can cause gas leaks and personal injury. Always use a NEW flexible connector.
Leak testing of the appliance shall be conducted according to the manufacturer instructions.
The range must be electrically grounded in accordance with local codes or, in the absence of local codes, in accordance with the National Electrical Code (ANSI/NFPA 70, latest edition). In Canada, electrical grounding must be in accordance with the current CSA C22.1 Canadian Electrical Code Part 1 and/or local codes. See Electrical Connections in this section.
Do not install this product with an air curtain hood or other range hood that operates by blowing air down on the cooktop. This airflow may interfere with operation of the gas burners resulting in fire or explosion hazard.
FOR YOUR SAFETY:
WARNING
• A child or adult can tip the range and be killed.
• Install the anti-tip bracket to the wall or floor.
• Engage the range to the anti-tip bracket by sliding the range back such that the foot is engaged.
• Re-engage the anti-tip bracket if the range is moved.
• Failure to do so can result in death or serious burns to children or adults.
If you did not receive an anti-tip bracket with your purchase, call 1.800.626.8774 to receive one at no cost. (In Canada, call 1.800.561.3344.) For installation instructions of the bracket, visit: www.GEAppliances.com. (In Canada, www.GEAppliances.ca.)
Tip-Over Hazard
Anti-Tip Bracket
Kit Included
WARNING
the installation, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
Before beginning
TOOLS YOU WILL NEED MATERIALS YOU MAY NEED
Gas line shut-off valve
Phillips
screwdriver
Flat-blade
screwdriver
Pencil and ruler
Pipe wrenches (2)
(one for backup)
1/4” Nut Driver
Tape Measure
Tin Snips
Open-end or
adjustable wrench
Level
Drill, awl or nail
Drill with 1/8” Bit
Pliers
Safety Glasses
Pipe joint sealant or UL-approved pipe thread
tape with Teflon* that resists action of natural and propane gases
Flexible metal appliance connector (1/2 I.D.).
A 5-foot length is recommended for ease of installation but other lengths are acceptable. Never use an old connector when installing a new range.
Flare union adapter for connection to gas
supply line (3/4 or 1/2 NPT x 1/2 I.D.)
Flare union adapter for connection to pressure
regulator on range (1/2” NPT x 1/2” I.D.)
Liquid leak detector or
soapy water.
Squeeze Connector
(For Conduit Installations Only)
(UL Listed 40 AMP)
4-Wire Cord 4’ long OR 3-Wire Cord 4’ long
*Teflon: Registered trademark of DuPont
BEFORE YOU BEGIN
,03257$17³
local inspector’s use.
Save these instructions for
,03257$17³ Observe all governing
codes and ordinances.
,03257$17³ Remove all packing
material and literature from oven before connecting gas and electrical supply to range.
,03257$17³ To avoid damage to your
cabinets, check with your builder or cabinet supplier to make sure that the materials used will not discolor, delaminate or sustain other damage. This oven has been designed in accordance with the requirements of UL and CSA International and complies with the maximum allowable wood cabinet temperatures of 194°F (90°C).
Note to Installer – Be sure to leave these instructions with consumer.
Note to consumer – Keep these instructions for future reference.
Servicer – The electrical diagram is in an envelope attached to the back of the range.
Proper installation is the responsibility of the installer.
Product failure due to improper installation is not covered under warranty.
Before installing your range on linoleum or any other synthetic floor covering, make sure the floor covering can withstand 180°F without
shrinking, warping or discoloring. Do not install the range over carpeting unless a sheet of 1/4” thick plywood or similar insulator is placed between the range and carpeting.
Mobile Home - Additional Installation Requirements
The installation of this range must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home Construction and Saftey, Title 24, HUD Part 280). When such standard is not applicable, use the Standard for Manufactured Home Installations, ANSI A225.1/ NFPA 501A or with local codes.
In Canada, the installation of this range must conform with the current standards CAN/CSA­A240-latest edition, or with local codes.
When this range is installed in a mobile home, it must be secured to the floor during transit. Any method of securing the range is adequate as long as it conforms to the standards listed above.
CAUTION Only the GE Café branded
series of Advantium® or microwave over­the-range ovens are designed to be installed above the GE Café range. Surfaces above a gas range can become hot. Installation of any other over-the-range oven above a GE Café range may result in surface temperatures that can cause burns.
DIMENSIONS AND CLEARANCES
Provide adequate clearances between the range and adjacent combustible surfaces. These dimensions must be met for safe use of your range.
Allow 30” (76.2 cm) minimum clearance between burners and bottom of unprotected wood or metal cabinet, or allow a 24” (61 cm) minimum when bottom of wood or metal cabinet is protected by no less than 1/4” (6.4 mm) thick flame-retardant millboard covered with no less than No. 28 MSG sheet metal (.015” [.38 mm]
1 1/2"
36 1/4" ± 1/4
27"
w/o handle
29 3/4"
w/ handle
48"
thick), .015” (.38 mm) thick stainless steel, .025” (0.64 mm) aluminum or .020” (0.5 mm) copper.
Installation of a listed microwave oven or cooking appliance over the cooktop shall conform to the installation instructions packed with that appliance.
For island installation, maintain 2-1/2” minimum from cutout to back edge of countertop and 3” minimum from cutout to side edges of countertop.
30"
DIMENSIONS AND CLEARANCES (CONT.)
GAS PIPE AND ELECTRICAL OUTLET LOCATIONS
30”
3”
3”
4
8
1
/
2
4
2
Recommended acceptable electrical outlet area. Orient the electrical receptacle so the length is parallel to the floor.
Recommended area for through-the-Wall connection of pipe stub and shut-off valve.
Recommended area for through-the-floor connection of pipe stub and shut-off valve.
3
9
1
/
2
7
CAUTION To prevent drafts from affecting burner operation,
seal all openings in floor under appliance and behind appliance wall.
If the countertop has a raised edge, shave the raised edge to clear the control panel as shown below.
9/16”
CONVERTING TO PROPANE GAS (OR CONVERTING BACK TO NATURAL GAS FROM PROPANE)
This range leaves the factory set for use with natural gas. If you want to convert to propane gas, the conversion must be performed by a qualified propane gas installer.
The conversion orifices and instructions can be found on back of the range.
Keep these instructions and all orifices in case you want to convert back to natural gas.
Propane Orifice Spud Holder
(some models)
View from front with
Warming Drawer removed
Rear of Range
Orifice Box (location may vary)
18”
Minimum to cabinets on either side of the range
6”
Minimum
clearance
to left wall
To cabinets below cooktop and at the range back
30” Minimum
0”
30”
6” Minimum clearance to right wall
Maximum
depth for
cabinets above
countertops
1/4”
13”
Front edge of the range side panel forward from cabinet
0” To cabinets below cooktop and at the range back
INSTALLATION INSTRUCTIONS
31-11034 02-16 GE
C2S985
ELECTRICAL REQUIREMENTS
1
WARNING: This appliance must be
properly grounded.
WARNING:
homes, recreational vehicles and installations where local codes do not allow grounding through neutral, require a 4-conductor UL-listed range cord.
All new constructions, mobile
WARNING: To prevent fire or shock, do
not use an extension cord with this appliance.
WARNING: To prevent shock, remove
house fuse or open circuit breaker before beginning installation.
We recommend you have the electrical wiring and hookup of your range connected by a qualified electrician. After installation, have the electrician show you how to disconnect power from the range.
You must use a single-phase, 120/208 VAC or 120/240 VAC, 60 hertz electrical system. If you connect to aluminum wiring, properly installed connectors approved for use with aluminum wiring must be used.
Effective January 1, 1996, the National Electrical Code requires that new construction (not existing) utilize a 4-conductor connection to an electric range. When installing an electric range in new construction, mobile home, recreational vehicle, or an area where local codes prohibit grounding through the neutral conductor, refer to the section on four-conductor branch circuit connections.
Check with your local utilities for electrical codes which apply in your area. Failure to wire your oven according to governing codes could result
in a hazardous condition. If there are no local codes, your oven must be wired and fused to meet the National Electrical Code, NFPA No. 70 – latest edition, available from the National Fire Protection Association.
This appliance must be supplied with the proper voltage and frequency, and connected to an individual, properly grounded, 40 amp (minimum) branch circuit protected by a circuit breaker or time-delay fuse.
Use only a 3-conductor or a 4-conductor UL-listed range cord. These cords may be provided with ring terminals on wire and a strain relief device.
A range cord rated at 40 amps with 125/250 minimum volt range is required. A 50 amp range cord is not recommended but if used, it should be marked for use with nominal 13ø8” diameter connection openings. Care should be taken to center the cable and strain relief within the knockout hole to keep the edge from damaging the cable.
The rating plate is located on the oven frame or on the side of the drawer frame.
Note: Use of automatic, wireless or wired external switches that shut off power to the appliances, are not recommended for this product.
SINGLE OVEN
Rating plate
POWER CORD AND CONDUIT INSTALLATION
2
A
Access the terminal block by removing
wire cover screws using a 1/4” nut driver. Do not discard these screws.
Retaining tabs
B
For power cord and 1” conduit only, the knockout ring (13ø8”) located on bracket directly below the terminal block. To remove the knockout, use a pair of pliers to bend the knockout ring away from the bracket and twist until ring is removed.
C
For power cord installations only (see the
next step if using conduit), assemble the strain relief in the hole. Insert the power cord through the strain relief and tighten. Allow enough slack to easily attach the cord terminals to the terminal block. If tabs are present at the end of the winged strain relief, they can be removed for better fit.
NOTE: Do not install the power cord
without a strain relief. The strain relief bracket MUST be installed before reinstalling the rear range wiring cover.
D
For 3/4” conduit installations only, purchase
a squeeze connector matching the diameter of your conduit and assemble it in the hole. Insert the conduit through the squeeze connector and tighten. Allow enough slack to easily attach the wires to the terminal block. NOTE: Do not install the conduit without a squeeze connector. The squeeze connector MUST be installed before reinstalling the rear range wiring cover.
PROCEED TO STEP 3 or 4
remove
Squeeze
connector
Terminal block (appearance may vary)
Knockout ring in bracket
Strain relief
Back of range
Knockout ring removed
Power cord
Conduit
Wire cover
5 screws to remove wire cover
Terminal block
Bracket
Terminal block
Bracket
3
3-WIRE INSTALLATION (GROUND IS THROUGH THE NEUTRAL WIRE)
WARNING: Shock Hazard
The neutral wire and ground strap must be connected as shown below for the range to be properly grounded. Do not remove the ground strap. Failure follow this instruction may result in potential shock hazard.
WARNING: Fire hazard
Terminal block screws must be securely tightened. Failure to do so may result in potential fire hazard.
FOR POWER CORD INSTALLATION A. Remove the 3 lower screws from the terminal
block. Do not loosen the upper screws.
B. Do not cut or remove the ground strap. C. Insert the 3 screws through each power cord
terminal ring and back into the terminal block. Be certain the white wire is in the center. Securely tighten each screw (35 to 50 in-lbs.)
FOR CONDUIT INSTALLATION A. Loosen the 3 lower screws on the terminal
block. Do not loosen the upper screws.
B. Do not cut or remove the ground strap. C. Insert the bare wire tip (insulation stripped
5/8”) into the bottom terminal block openings. Be certain the white wire is in the center. On certain models, the wire must be inserted through an opening in the ground strap. Securely tighten each screw onto each wire (35 to 50 in-lbs.).
NOTE: Aluminum building wire may be used but it must be rated for the correct amperage and voltage.
PROCEED TO STEP 5
Terminal block (appearance may vary)
Neutral terminal
Ground strap
Ground plate
Red or Black
Power cord
Terminal block
Wire tips
Red or Black
Conduit
Power Cord
Conduit
White
White
Red or Black
Red or Black
4
4-WIRE INSTALLATION (SEPARATE GROUND WIRE)
WARNING: Shock Hazard
The neutral wire and ground strap must be connected as shown below for the range to be properly grounded. Do not remove the ground strap. Failure follow this instruction may result in potential shock hazard.
Before–Power Cord and Conduit
Terminal block
WARNING: Fire hazard
Terminal block screws must be securely tightened. Failure to do so may result in potential fire hazard.
FOR POWER CORD INSTALLATION A. Remove the 3 lower screws from the
terminal block. Do not loosen the upper screws.
B. Remove the ground screw and ground plate
and retain them.
C. Cut the ground strap below the terminal
block and discard the lower section.
D. Insert the ground screw through the ground
plate (removed earlier) and back into the range frame. Tighten securely, but do not over-tighten (15 to 20 in-lbs.)
E. Insert the 3 terminal screws through each
power cord terminal ring and back into the terminal block. Be certain the white wire is in the center. Securely tighten each screw (35 to 50 in-lbs.
FOR CONDUIT INSTALLATION A. Remove the 3 lower screws from the terminal
block. Do not loosen the upper screws.
B. Remove the ground screw and ground plate
and retain them.
C. Cut the ground strap below the terminal block
and discard the lower section.
D. Insert the bare ground bare wire tip (insulation
stripped 5/8”) between the range frame and the ground plate (removed earlier) and secure it in place with the ground screw. Tighten securely, but do not over-tighten (15 to 20 in-lbs).
E. Insert the wire tips (insulation stripped 5/8”)
into the bottom terminal block openings. Be certain the white wire is in the center. On certain models, the wire must be inserted through an opening in the ground strap. Securely tighten each screw onto each wire (35 to 50 in-lbs.)
NOTE: Aluminum building wire may be used but it must be rated for the correct amperage and voltage.
Ground strap
Terminal block
Red or Black
Ground screw
Terminal block
Wire tips
After–Power Cord
White
Green or Bare
After–Conduit
Red or Black
White
Ground screw
Ground strap
or
Neutral terminal
Neutral terminal
Ground plate (grounding to range)
Red or Black
Ground plate (grounding to range)
Red or Black
Green or Bare
5
REPLACE THE WIRE COVER
Replace wire cover on range back by sliding
its left edge under the retaining tabs and replace the screws removed earlier. Make sure that no wires are pinched between cover and range back.
GAS SUPPLY
6
WARNING Fire Hazard: Do not use a
flame to check for gas leaks.
WARNING Explosion Hazard: Do not
exceed 25 ft-lbs of torque when making gas line connections. Overtightening may crack the pressure regulator resulting in fire or explosion hazard.
Gas Pressure Regulator
You must use the gas pressure regulator supplied with this range. For proper operations the inlet pressure to the regulator should be as follows:
Natural Gas:
Minimum pressure: 6” of Water Column Maximum pressure: 13” of Water Column
Propane Gas:
Minimum pressure: 11” of Water Column Maximum pressure: 13” of Water Column
If you are not sure about the inlet pressure contact local gas supplier.
Shut off the main gas supply valve before disconnecting the old range and leave it off until the new hook-up has been completed. Don’t forget to relight the pilot on other gas appliances when you turn the gas back on.
Because hard piping restricts movement of the range, the use of a CSA International­certified flexible metal appliance connector is recommended unless local codes require a hard­piped connection.
If the hard piping method is used, you must carefully align the pipe; the range cannot be moved after the connection is made.
Back of range
5 screws to
Retaining tabs
Wire cover
To prevent gas leaks, put pipe joint compound on, or wrap pipe thread tape with Teflon* around, all male (external) pipe threads.
A. Install a manual shut-off valve in the gas line
in an easily accessed location outside of the range. Make sure everyone operating the range knows where and how to shut off the gas supply to the range.
B. Install male 1/2” flare union adapter to the 1/2”
NPT internal thread at inlet of regulator. Use a backup wrench on the regulator fitting to avoid damage.
C. Install male 1/2” or 3/4” flare union adapter to
the NPT internal thread of the manual shut-off valve, taking care to back-up the shut-off valve to keep it from turning.
D. Connect flexible metal appliance connector
to the adapter on the range. Position range to permit connection at the shut-off valve.
E. When all connections have been made, make
sure all range controls are in the off position and turn on the main gas supply valve. Use a liquid leak detector at all joints and connections to check for leaks in the system.
When using pressures greater than 1/2 psig to pressure test the gas supply system of the residence, disconnect the range and individual shut-off valve from the gas supply piping. When using pressures of 1/2 psig or less to pressure test the gas supply system, simply isolate the range from the gas supply system by closing the individual shut-off valve.
When checking for proper operation of the regulator, the inlet pressure must be at least 1” greater than the operating (manifold) pressure as given on rating label of product.
*Teflon: Registered trademark of DuPont
remove wire cover
GAS SUPPLY (CONT)
6
CONNECTOR HOOKUP
Gas Flow into Range Gas Flow into Range
Pressure regulator
Adapter
Flexible
Option
SURFACE BURNERS
7
1/2 or 3/4
Gas pipe
Installer: Inform the consumer of the location of the gas shut-off valve.
Flex connector (6 ft. max.)
Adapter
Gas shut-off valve
Cap
WARNING Fire or Explosion Hazard:
Do not operate the burner without all burner parts in place.
A. Burners - Place surface burners into
corresponding positions on cooktop. B. Caps - Place caps on proper size burner.. C. Grates - The left and right grates are
interchangeable. Place the grates on the
cooktop.
Left
Grate
Burner
Grate or Griddle
Center
Elbow
Rigid Pipe
Option
Electrode
Pressure regulator
or
Cap
Front right burner
Elbow
Nipple
Union
Nipple
Gas shut-off valve
1/2 or 3/4
Gas pipe
Electrode
Hole
Right Grate
CHECK SURFACE BURNERS
8
Push and turn knob to LITE position. You will hear a clicking sound indicating proper operation of the spark module. Once the air has been purged from the supply lines, burners should light within 4 seconds. After burner lights, rotate knob out of the LITE position. Try each burner in succession until all burners have been checked.
Quality of Flames
The flame quality of the burners needs to be determined visually.
If burner flames look like (A), call for service. Normal burner flames should look like (B) or (C), depending on the type of gas you use
With propane gas, some yellow tipping on outer cones is normal.
INSTALL AND CHECK
9
ANTI-TIP DEVICE
WARNING
leveling leg as the range will not be secured to the anti-tip device properly.
Follow instructions supplied with ANTI-TIP bracket
LEVEL THE RANGE
10
WARNING
leveling leg as the range will not be secured to the anti-tip device properly.
A. Plug in the unit. B. Measure the height of your countertop at the
rear of the opening (X).
C. Adjust two rear leveling legs so that the rear of
cooktop is at the same height or higher than the counter (Y).
D. Slide unit into place. E. Install oven shelves in the oven and position the
range where it will be installed.
F. Check for levelness by placing a spirit level on
RQHRIWKHRYHQVKHOYHV7DNHWZRUHDGLQJV³ZLWK
the level placed diagonally first in one direction and then the other.
G. Adjust front leveling legs until the range is level. H. Look under the unit and verify that the rear leg
is fully engaged with the anti-tip device. If not, remove the unit and adjust the height of the rear leg so that it is properly engaged.
Never completely remove the
Never completely remove the
Spirit level
$<HOORZIODPHV³
Call for service
(B) Yellow tips on
RXWHUFRQHV³
Normal for Propane gas
&6RIWEOXHIODPHV³
Normal for natural gas
X
Y
Cooktop
NOTE: Cooktop must be at or above counter.
Anti-Tip Bracket
Kit Included
Grate
Counter
11
FINAL INSTALLATION CHECKLIST
• Check to make sure the circuit breaker is closed (RESET) or the circuit fuses are replaced.
• Be sure power to the building is in service.
• Check that all packing materials and tape have been removed. This includes all adhesive tape, wire ties, cardboard and protective plastic. Failure to remove these materials could result in damage to the appliance once the appliance has been turned on and surfaces have heated.
• Check that the door and drawer are parallel to each other and that both operate smoothly. If they do not, see the Owner’s Manual for adjustment instructions.
• Check to make sure that the rear leveling leg is fully engaged into the Anti-Tip bracket and that the bracket is securely installed.
OPERATION CHECKLIST
• Check that the clock display is energized. If ‘bad line’ appears in the display, disconnect power immediately. Recheck the range wiring connections. If range wiring is correct, have building wiring checked for proper connections and voltage.
• Activate BROIL and make sure the element glows within 60 seconds. Cancel BROIL when glow is detected. If glow is not detected within the time limit, recheck the range wiring connections. If range wiring is correct, have building wiring checked for proper connections and voltage.
• Be sure all range controls are in the OFF position before leaving the range.
WHEN ALL HOOKUPS ARE COMPLETED
Make sure all controls are left in the off position. Make sure the flow of combustion and ventilation air to the range is unobstructed.
Check that all packing materials and tape have been removed. This will include tape on metal panel under control knobs (if applicable), adhesive tape, wire ties, cardboard and protective plastic. Failure to remove these materials could result in damage to the appliance once the appliance has been turned on and surfaces have heated.
INSTALLATION INSTRUCTIONS