GE C1S Data Sheet

GE
Lighting Solutions
Industrial Lighting
C1S Conserva™ 150 (C1S)
imagination at work
Product Features
GE Indoor Lighting luminaires are designed to produce optimum illumination from the lamp, optical system and ballast,
while providing specic light patterns for specic applications. These reliable systems help to improve safety and energy savings, while enhancing productivity and efciency, to put your industrial workplace in the best possible light.
Applications
assembly lines, manufacturing areas, food processing plants, warehouses and parking garages, other industrial applications
Housing
• Die-cast aluminum ballast housing
Finish
• Polyester powder gray paint nish
Ratings
Listed Suitable for Wet or Damp locations
/
depending on mounting receptacle used
Listed for metal halide lamps in polymeric lamp
/
containment barriers
• cUL Listed to Canadian standards & codes
Mounting
• Primary quick disconnect for easy mounting
Reflector
• Aluminum reector with Alzak nish
Unique Features
• Standard construction is IP52
• Maximum seal reliability for clean optical component
• UV stabilized injection molded prismatic refractor for
low brightness
• Mogul base socket - E39 standard
• Safety chain provisions
• Shipped as components: Ballast, Optical, Mounting
Receptacle
• Magnapack available for ballast
• Pulse start system for metal halide available
Ordering Number Logic
C1S Conserva™ 150 (C1S)
C1S TA _ _ _ - _ _ - _ - _ - _ - _ - _ _ - _ - _
PROD. ID
C1S =
Conserva 150 Luminaire
WAT TAG E
07 = 70 10 = 100 15 = 150
(55V)
17 = 175 25 = 250
LIGHT
SOURCE
E = Energy
Act Compliant Pulse MH (EPMH)
S = HPS K = Ceramic
MH P = Pulse Start MH
Note: Lamp is vertical base up. Lamp not included.
VOLTAGE
60Hz 0 = 120/208/
240/277
MULTIVOLT
1 = 120 2 = 208 3 = 240 4 = 277 5 = 480 D = 347 F =
120X347
T = 220
50Hz 6 = 220 Y = 240 G = 380
BALLAST
See Ballast Selection Table
A = Autoreg G = Mag-Reg
H = HPF Reactor
K = Hot Restart M = Mag-Reg
TYPE
with Grounded Socket Shell
or Lag
Photometric Selection Table
CIS
Wattage Light Maximum Spacing Source Ambient Criteria Curve
70* PMH 40C 1.6 452584 100* PMH 40C 1.7 452583 175 EPMH 40C 1.7 175836 175(COATED) EPMH 40C 1.9 175924 250 EPMH 40C 1.7 175836 250(COATED) EPMH 40C 1.9 175924 70* Ceramic MH 40C 1.6 452585 100* Ceramic MH 40C 1.7 452586 150* PMH 40C 1.6 452582 70,100 HPS 55C 1.8 175835
150(55V) HPS 55C 1.8 175835
250 HPS 40C 1.8 175842
Photometric
AMBIENT
°C
See Ballast and Photometric Selection Tables
4 = 40 5 = 55
OPTICAL OPTIONS
TA = Enclosed
Acrylic
* Medium base socket. (Lamp not included)
Note: C/F = Call Factory
1 = Ceiling
(MPM-C)
2 = 3/4-in. Pendant, Rigid (MPM-3PR)*
3 = 3/4-in. Pendant ,
Rigid, Wet Locations (MPM-3PRW)*
4 = 3/4-in. Pendant , Rigid, with Thru
Feed, Wet Locations (MPM-3PRTFW)*
5 = 3/4-in. Pendant ,
Flexible (MPM-3PF)
6 = Outlet Box Cover
(MPM-OBC)
*NOTE: Flexible
pendant mounting receptacle must be used if unit is not rigidly
mounted or xture will
not hang straight
MOUNTING
RECEPTICAL
B = Time Delay Automatically
Switch Quartz
F = Fusing Q = Non-Time Delay
Automatically Switch Quartz
Note: Wet location determined
by mounting receptacle
Ballast Selection Table
60HZ 50HZ 120, 208 120
Light 240, 277 x Wattage Source Multivolt 480 347 347 220 220 230 240 380
70 HPS H,K G,H**,K,M G,H,K H,K N/A N/A M N/A N/A 100 HPS H,K G,H**,K,M G,H,K H,K N/A H,M H,M H N/A 150(55V) HPS H,K G,H**,K,M G,H,K H,K A,M H H H N/A 250 HPS A A A A N/A H H,A H, A N/A 70* Cer, MH H H H N/A N/A N/A N/A N/A N/A 100* Cer, MH H H H N/A N/A N/A N/A N/A N/A 70* MH H H H N/A N/A N/A N/A N/A N/A 100* MH H H H N/A N/A N/A N/A N/A N/A
PULSE START METAL HALIDE LIGHT SOURCE BALLAST SELECTION TABLE
150* P (MH) N/A H** H N/A N/A N/A N/A N/A N/A 175 EPMH N/A A A A N/A N/A N/A N/A N/A
250 EPMH A A A A N/A N/A N/A N/A N/A
Ballast Type / Voltage
NOTE: N/A = Not Available
* Medium base socket (Lamp not included)
** 480 Volt not available
CANADIAN NOTES:
1. “A” ,Autoreg, and “H”, HPF available 120, 277 or 347 volts only
2. 208, 240, and 480 volts require CWI ballast. Use “G” when
available. Contact factory for all others.
3. Multivolt not available.
4. “K” Hot Restart not available.
5. 208, 240 and 480 volts with “G” ballast not available with
switched quartz.
Product Dimensions
C1S Conserva™ 150 (C1S)
• Approximate Net Weight: Ballast and Optical: 21-32 lbs (10-15 kgs)
DATA
GE Lighting Solutions 1-888-MY-GE-LED www.gelightingsolutions.com
1 - 8 8 8 - 6 9 - 4 3 - 5 3 3
GE Lighting Solutions, LLC is a subsidiary of the General Electric Company. The GE brand and logo are trademarks of the General Electric Company. © 2011 GE Lighting Solutions, LLC. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions.
OLP-0000 (Rev. 10/25/11)
Loading...