GE BF50UQ, BF80UQ, BF80S, BF100UQ, BF100S User Manual

...
Page 1
BF50UQ, BF80UQ, BF80S, BF100UQ, BF100S,
BF110UQ, BF110S, BF125UQ, BF130UQ, BF135UQ
e
Ultra Quiet Bath Fan User s Guide
Item Stock Number(s): BF50UQ, BF80UQ, BF80S, BF100UQ, BF100S,
BF110S, BF110UQ, BF125UQ, BF130UQ, BF135UQ
IMPORTANT INSTRUCTIONS -
a
OPERATING MANUAL
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED.
PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH
When using electrical appliances, basic precautions should always be followed to reduce
the risk of fire, electric shock and injury to person, including the following:
1. Read all instructions before installing or using exhaust fan.
2. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.
3. Before servicing or cleaning the unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
4. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire­related construction.
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
GENERAL SAFETY INFORMATION
5. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA) and the American Society for Heating, Refrigeration, and Air Conditioning Engineers (ASHRAE), and the local code authorities.
CAUTION: FOR GENERAL VENTILATING USE ONLY. DO NOT USE
TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS AND VAPORS.
6. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
7. Ducted fans must always be vented to the outdoors.
210572115 Rev. E 8-09
SAVE THESE INSTRUCTIONS
www.geelectrical.com
1 of 4
Page 2
GENERAL SAFETY INFORMATION
(Continued)
8. This unit must be grounded.
9. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, DO
NOT USE THIS FAN WITH ANY SOLID-STATE SPEED CONTROL DEVICE.
10. Acceptable for use over a bathtub or shower when installed in a GFCI protected branch circuit.
11. NEVER place a switch where it can be reached from a tub or shower.
WARNING: DO NOT USE IN KITCHENS
INSTALLATION INSTRUCTIONS
careful not to cut or damage any electrical or other hidden utilities. Install the side rails on the housing and position the housing in the previously cut hole so that it is flush with the finished ceiling. Secure the ends of the rails to the joists (Figure 2).
Joist
Figure 3
CAUTION:
PANEL BEFORE STARTING INSTALLATION.
MAKE SURE POWER IS SWITCHED OFF AT SERVICE
SECTION 1
Preparing the Exhaust Fan
1. Unpack fan from the carton and confirm that all pieces are present. In addition to the exhaust fan you should have:
1 - Grill 1 - Damper Assembly (attached) 4 - Mounting Rails 1 - Instruction/Safety Sheet
2. Choose the location for your fan. To ensure the best air and sound performance, it is recommended that the length of ducting and the number of elbows be kept to a minimum, and that insulated hard ducting be used. Larger duct sizes will reduce noise and airflow restrictions. This fan will require at least 8" of clearance in the ceiling or wall, and will mount through drywall up to 3/4" thick. The fan mounts between 16" or 24" on center joists using the 4 provided mounting rails.
3. Select the most convenient electrical knockout and remove using a straight­blade screw driver (Figure 1).
SECTION 2
New Construction
1. Install the side rails on the housing and position the housing next to the joist. Line up housing so that it will be flush with the finished ceiling. Secure the ends of the rails with screws or nails (not included) to the joists and slide the housing into the final position (Figure 2).
Housing
Figure 1
SECTION 4
Ducting
CAUTION: ALL DUCTING MUST COMPLY WITH LOCAL AND
NATIONAL BUILDING CODES.
1. Connect the ducting to the fan’s duct collar (Figure 4). Secure in place using tape or screw clamp. Always duct the fan to the outside through a wall or roof cap.
Ducting
Duct Collar
Figure 4
SECTION 5
Wiring
CAUTION: MAKE SURE POWER IS SWITCHED OFF AT SERVICE
PANEL BEFORE STARTING INSTALLATION.
CAUTION: ALL ELECTRICAL CONNECTIONS MUST BE MADE IN
ACCORDANCE WITH LOCAL CODES, ORDINANCES, OR NATIONAL ELECTRICAL CODE. IF YOU ARE UNFAMILIAR WITH METHODS OF INSTALLING ELECTRICAL WIRING, SECURE THE SERVICES OF A QUALIFIED ELECTRICIAN.
NOTE: This unit includes a side access panel for wiring that does not require
the removal of the fan’s blower assembly. If you choose to wire the unit from the inside, you will need to remove the blower assembly and internal wiring compartment. Both methods are equally effective.
1a. External Wire Compartment: Remove the wire compartment cover screw
and place cover in a secure place (Figure 5).
Joist
Figure 2
Hanger Bar
SECTION 3
Existing Construction
1. Set housing in position between the joist and trace an outline onto the ceiling material (Figure 3). Set housing aside and cut opening, being
210572115 Rev. E 8-09
www.geelectrical.com
Screw
Wire Compartment Cover
Figure 5
2 of 4
Page 3
1b. Internal Wire Compartment: Remove the screw holding the venturi in
place. Lift the venturi up and at an angle to slide it out of the housing (Figure 6). Remove the wire compartment cover screw and place the cover in a secure place (Figure 7).
Plug
Venturi
Screw
Figure 6
SECTION 6
Completing the Installation
1. If the fan’s blower assembly was removed during the wiring process, reinstall the blower by reversing the directions in
Wiring
.
2. Plug the fan’s quick connect motor cord into the receptacle. This cord will only fit one way into the receptacle (Figure 9).
Step 1b
in Section 5
NOTE: If the fan motor plug is connected to the fan housing receptacle, unplug so the venturi can be completely removed.
Screw
Compartment
Wire
Cover
Figure 7
2. Run wiring from an approved wall switch carrying the appropriate rating. One neutral (white), one ground (green or bare copper), and one hot (black lead connected to the switch). Secure the electrical wires to the housing with an approved electrical connector. Make sure you leave enough wiring in the box to make the connection to the fan’s receptacle.
3. From where you have chosen to access the fan’s junction box, connect the White wire from the house to the White wire from the fan’s receptacle. Connect the Black wire from the wall switch to the Black wire from the fan’s receptacle. Connect the ground wire from the house to the Green wire from the fan’s receptacle (Figure 8). Use approved methods for all connections.
Supply from
house
Ground
White
Hot (Black)
Figure 8
NOTE: The fan’s receptacle wires might need to be pulled outside compartment for connection. Only pull the three loose wires outside of compartment. Additional wires will be present.
4. Carefully tuck wire back inside wire compartment and replace wire compartment cover securing with the screw that was removed earlier.
Figure 9
3. Install the grill by squeezing the two ends of the springs together and installing them up into the slots on the fan’s housing. Push the grill up into position (Figure 10).
Figure 10
4. Restore power and test your installation.
SECTION 7
Use and Care
CAUTION: MAKE SURE POWER IS SWITCHED OFF AT SERVICE
PANEL BEFORE SERVICING THE UNIT.
1. Cleaning the Grill: Remove grill and use a mild detergent, such as dishwashing liquid, and dry with a soft cloth. NEVER USE ANY ABRASIVE PADS OR SCOURING POWDERS. Completely dry grill before reinstalling. Refer to instructions in Section 6 grill.
2. Cleaning the Fan Assembly: Wipe all parts with a dry cloth or gently vacuum the fan. NEVER IMMERSE ELECTRICAL PARTS IN WATER.
Finishing the Installation
, to reinstall
Troubleshooting Guide
Trouble Probable Cause Suggested Remedy
1. Fan does not operate when the switch is on. 1a. A fuse may be blown or a circuit tripped. 1a. Replace fuse or reset circuit breaker.
2. Fan is operating, but air moves slower than normal. 2. Obstruction in the exhaust ducting. 2. Check for any obstructions in the ducting. The most common
3. Fan is operating louder than normal. 3a. Motor is loose. 3a. Turn off power to unit. Remove grill and check that all screws
210572115 Rev. E 8-09
1b. Connector plug from motor is not plugged in. 1b. Turn off power to unit. Remove Grill and plug motor into
receptacle in housing. Restore power to unit.
1c. Wiring is not connected properly. 1c. Turn off power to unit. Check that all wires are connected.
are bird nests in the roof cap or wall cap where the fan exhausts to the outside.
are fully tightened. Restore power to unit.
3b. Fan blade is hitting housing of unit. 3b. Call your dealer for service.
www.geelectrical.com
3 of 4
Page 4
WARRANTY
WHAT IS COVERED?
Full Five Year Parts Warranty from date of original proof of purchase. We will provide, free of charge, a replacement part that fails due to manufacturing defect in material or workmanship, when installed and used as directed in the User’s Guide.
This warranty is extended to the original purchaser for products purchased for ordinary home use.
GE Bath Fan Hot Line
1-800-684-9975
FOR TECHNICAL ASSISTANCE
AND / OR QUESTIONS.
This warranty contains the sole and exclusive warranty of GE for claims based on defects in these products. Upon the expiration of the warranty period, all such liability shall terminate. There are no other warranties, whether written, oral, implied or statutory. NO IMPLIED STATUTORY WARRANTY OF MERCHANTABILITY OR FITNESS FOR PARTICULAR PURPOSE SHALL APPLY.
IN NO EVENT SHALL GE BE LIABLE FOR ANY SPECIAL, CONSEQUENTIAL, INDIRECT, OR INCIDENTAL DAMAGES, SUCH AS, BUT NOT LIMITED TO, LOSS OF PROFIT OR REVENUES, LOSS OF USE OF THE PRODUCTS OR ANY ASSOCIATED EQUIPMENT, DAMAGE TO ASSOCIATED EQUIPMENT, OR COST OF SUBSTITUTE PRODUCTS.
IN NO EVENT, SHALL GE’S LIABILITY TO BUYER FROM THE SALE OF THESE PRODUCTS EXCEED THE PRICE OF THE DEFECTIVE PRODUCT SOLD AND ANY SUCH LIABILITY SHALL TERMINATE UPON THE EXPIRATION OF THE WARRANTY PERIOD.
WHAT IS NOT COVERED?
• Installation services or service trips to your home to teach you how to use
the product.
• Labor costs or the cost of replacement components as part of routine
maintenance.
• Failure or defects in product arising from Improper installation
If you have an installation problem, contact your dealer or installer. You are responsible for providing adequate electrical, exhausting and other connecting facilities. See the Installation Instructions provided with this product for electrical, exhaust and connection details.
• Replacement of house fuses or resetting of circuit breakers.
• Failure of the product if it is used for something other than the intended
purpose of manufacturer or used commercially.
• Damage to the product caused by accident, fire, floods, acts of customer,
or acts of God.
Read your User s Guide. If you have any questions about operating the product, please contact your dealer.
Some states and provinces do not allow the exclusion or limitation of incidental or consequential damages and some states do not allow limitations on how long an implied warranty lasts, so these exclusions or limitations may not apply to you. This warranty gives you specific legal rights and you may have other rights which vary from state to state and province to province.
# Qty. Description Replacement Part # 1 1 Fan Housing 5S1202001 2 4 Mounting Rails 5S1299002 3 1 Collar 5S1299003 4 1 Damper 5S1299004 5 1 Motor 5S2202001 6 2 Screw 5S2202002 7 1 Blower Wheel 5S2202003 8 7 Blower Screws 5S2202004
9 1 Motor Plate 5S2202005 10 1 Venturi 5S2202006 11 1 Screw 5S1999009 12 1 Motor Cap Harness
BF50UQ 5S2202031 BF80S, BF100S 5S2202007 BF80UQ, BF100UQ 5S2202008 BF110S 5S2202012 BF110UQ, BF135UQ 5S2202010
BF130UQ 5S2202011 13 1 Screw 5S1999010 14 1 Internal Wire Cover 5S1202004 15 1 Screw 5S1999011 16 1 Grill 5S1202005 17 2 Grill Springs 5S1202006 18 1 #10 Ground Screw 5S1999002 19 1 14 ga Ground Wire 5S1999003 20 1 Screw 5S1999010 21 1 External Wire Cover 5S1202007
20
17
21
16
19
1
18
12
8
9
10
15
14
2
3
4
11
5
13
6
7
210572115 Rev. E 8-09
www.geelectrical.com
4 of 4