GE Batten LED Installation Guide

Page 1
GE
Lighting
Batten LED Luminaire
LED Lighting System
GEWI10XXYYBAT
*Key for XX: 24 = 24 in, 48 = 48 in, 96 = 96 in *Key for YY: 30 = 3000K, 40 = 4000K, 50 = 5000K, 71 = 7100K
BEFORE YOU BEGIN
Read these instructions completely and carefully.
WARNING/AVERTISSEMENT
RISK OF ELECTRIC SHOCK
• Turn power off before inspection, installation or removal.
• The electrical supply for each luminaire must always be connected to the male connector.
RISK OF FIRE
• Follow all NEC and local codes.
Installation Guide
RISQUES DE DÉCHARGES ÉLECTRIQUES
• Coupez l’alimentation avant l’inspection, l’installation ou le déplacement.
• L’alimentation électrique pour chacun des luminaires doit toujours être branché du côté mâle de la prise.
RISQUES D’INCENDIE
• Respectez tous les codes NEC et codes locaux.
Save These Instructions
This product is intended solely for the use of non-residential architecture lighting and is not intended for use in any other application.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. CAN ICES-3 (A)/NMB-3(A)
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in ac­cordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a resi­dential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Prepare Electrical Wiring
Electrical Requirements
• Follow all National Electric Codes (NEC) and local codes.
imagination at work
Page 2
Tools Required Components Required
21
3
Wire stripper/cutter
1 1
Screwdriver
2 2
Cordless drill with driver bit
3 3
1
3 4 5
2
GE LED Batten xtures
Leader cable (96440)
GE plastic mounting clips (96442)
#10 (M5) self-tapping athead screws
4
UL approved 18-14 AWG (0.82-2.08 mm2) wire
5
connectors or in-line splice connectors
End cap for connectors
6
Optional: Jumper cable (96441: 24 in./610 mm long)
7
7
6
Installation
Assemble the LED xture by pressing both mounting
1 2
clips onto the LED Batten. A snapping noise should
be heard. Refer to Specications table on page 4 for
required number of mounting clips.
Mount the xture to the desired ceiling/wall using two #10 (M5) self-tapping athead screws in each
mounting bracket.
Page 3
Leader cable to LED xture
Black (+)
White (-)
120-277V
AC Line
Connect the leader cable to the male plug on the
3
rst LED xture. Two clicking noises should be
heard.
WARNING
The electrical supply for each luminaire must
always be connected to the male connector.
Orient plugs male to female
Remove endcap from other side.
4
Continue placing xtures, being sure to join
5
plugs male to female. Attach jumper cables as needed to work around any obstacles, corners or separations.
Electrical Connections
Leader cable
Connect the black (line) and white (neutral) wires
7
of the AC line to the similarly colored wires of the leader cable using wire nuts.
AC line
Place end cap from Step 4 on the electrical plug of
6
the last xture in the run.
Wiring diagram.
8
Page 4
Batten Replacement Instructions
NOTE: The following scenario is based on replacing the third xture in a series of ve.
Mounting surface
1 2 3 4 5
Loosen mounting bracket screws for xtures 1, 2 or 4,5
Loosen mounting bracket screws on the Batten xtures preceding the xture to be replaced (either xtures 1,2 or
1
4,5). This will help the xtures to slide in Step 2
Loosen brackets
Batten to
be replaced
Slide loosened
Battens 2 inches
Pinch
Batten to
be replaced
Unclip plug on the side with the loosened mounting
2 3
bracket screws and slide Battens at least 2 inches to disengage.
Loosen the screws on all mounting brackets on the Batten to be replaced, so that the screws are
still holding the xture, but will allow it to slide.
TIP: Pinch the ends of the plug while pulling the receptacle end away.
Unplug Batten to be replaced
Unclip the plug on the other side. Completely unscrew the previously loosened
4 5
Pinch
screws on all mounting brackets of Batten to be replaced and remove the Batten.
To insert new Batten, complete steps 1-5 in reverse order.
6
Page 5
Troubleshooting
Symptom Solution
All LED xtures are not
illuminated
Some LED xtures are
not illuminated
Specications
SKU Description Code
64409 GEWI102430BAT
64430 GEWI102440BAT
64431 GEWI102450BAT
94454 GEWI102471BAT
94455 GEWI102440BAT
94456 GEWI102430BAT
64432 GEWI104830BAT
64433 GEWI104840BAT
64434 GEWI104850BAT
94457 GEWI104871BAT
94458 GEWI104840BAT
94459 GEWI104830BAT
64472 GEWI109630BAT
64473 GEWI109640BAT
65653 GEWI109650BAT
94460 GEWI109671BAT
94461 GEWI109640BAT
94462 GEWI109640BAT
• Check leader cable connection and/or check circuit breaker.
• Check plug connectors on the LED xtures for improper connections or short circuits.
• Ensure leader cable is securely connected to the female plug connector on the rst LED xture.
• Check plug connectors on the LED xtures for improper connections or short circuits.
• Ensure any jumper cables are securely connected between the male/female plug connectors of the
LED xtures.
Number of
mounting
clips required Voltage
2 120 VAC-277 VAC, 50-60Hz
2 120 VAC-277 VAC, 50-60Hz
3 120 VAC-277 VAC, 50-60Hz
Maximum Run Length
For both 120 VAC and 277 VAC:
20 xtures (40 feet/ 12 meters)
For both 120 VAC and 277 VAC:
10 xtures (40 feet/ 12 meters)
For both 120 VAC and 277 VAC:
5 xtures (40 feet/ 12 meters)
Location Rating
Dry or Damp
Location
Conforms to the following standards:
GE Lighting • 1-888-MY-GE-LED
GE Lighting Solutions, LLC is a subsidiary of the General Electric Company. Tetra is a trademark of GE Lighting. The GE brand and logo are trademarks of the General Electric Company. © 2014 GE Lighting Solutions, LLC. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions.
(1-888-69-43-533)
• www.gelighting.com
GE2025-9415
SIGN124-103114
Loading...