GE ZISW, B480DX User Manual

ZISW/B480DX
*84" From Floor to Top Frame
48"
Frame to Frame
47"
Case Width
*83-1/2"
at
Rear
25-3/8
26-7/8"
including
handle
23-7/8"
Behind
Frame
90° Door Swing
4" Min. to Wall
28-5/8"
20"
130° Door Swing
15"
*Finished Width
6"
5"
Electrical Area
84-1/2" max
83-1/2" min
Finished Opening
75" From Floor
to Bottom
of Electrical
Area
24"
5"
5"
3-1/2"
Water Supply
3-1/2"
36" Models 12" 42" Models 18" 48" Models 20"
GE Monogram® 48" Built-In Side-by-Side Refrigerator with Dispenser and Water Filter
Dimensions and Installation Information (in inches)
The Installation Space
* Shipping height.
The refrigerator can be adjusted to fit into a cutout that is 83-1/2" min. to 84-1/2” max. height. Note that the top case trim at the front is 1/2" higher and will overlap upper cabinetry or soffit. Use leveling legs and wheels for a maximum 1" height adjustment.
Product Clearances
These refrigerators are equipped with a 2 position door stop. The factory set 130° door swing can be adjusted to 90° if clearance to adjacent cabinets or walls is restricted.
Allow minimum clearances for freezer door and fresh food door for a full 130° door swing and to allow for pan removal.
4" minimum clearance is required when door swing is adjusted to 90°. If the 90° door stop position is used, pan access is maintained, but pan removal is restricted.
Installation Information: Before installing, consult installation instructions packed with product, or online at Monogram.com, for current dimensional data.
Water and electrical locations
The opening must be prepared with the electrical and water supply located as shown.
The cutout depth must be 24".
The refrigerator will project forward, slightly beyond adjacent cabinetry, depending on your installation.
The cutout depth beneath a soffit:
When installed beneath a soffit, the soffit cannot exceed the 24" installation depth shown. The top case trim overlaps the bottom of the soffit.
Additional Specifications
• A 115 volt 60Hz., 15 or 20 amp power supply is required. An individual properly grounded branch circuit or circuit breaker is recommended. Install a properly grounded 3­prong electrical receptacle recessed into the back wall. Electrical must be located on rear wall as shown.
Note: GFI (ground fault interrupter) is not recommended.
• Water line can enter the opening through the floor or back wall. The water line should be 1/4" O.D. copper tubing or GE SmartConnect™ kit between the cold water line and water connection location, long enough to extend to the front of the refrigerator. Installation of an easily accessible shut off valve in the water line is recommended.
For answers to your Monogram,® GE Profile™ or GE® appliance questions, visit our website at ge.com or call GE Answer Center® service,
800.626.2000.
Listed by Underwriters Laboratories
Specification Created 3/08
As an ENERGY STAR® partner, GE has determined that this product meets the ENERGY STAR for energy efficiency.
guidelines
110180
ZISW/B480DX
Framed Panel
3/4" Overlay Panel
.10" Thick Spacer Panel
1/4" Thick Backer Panel
*84"
2-9/16"
24"
*3" to 4"
3/16"
1-7/8"
GE Monogram® 48" Built-In Side-by-Side Refrigerator with Dispenser and Water Filter
Dimensions and Installation Information (in inches)
Customization Basics: Framed or Overlay Panels, Custom Handles and Accessory Kits
Trimmed Refrigerators ZIS420NXSS, ZISW420DXSS, ZISB420DXSS
Trimmed refrigerators are designed to be customized with decorative panels. Field-installed custom door and grille panels are required.
Framed Panels
You may install 1/4"-thick custom panels from your cabinet manufacturer. The decorative panels slide into the factory­installed trim. Or, order black, white and stainless steel accessory panels from your Monogram dealer.
Standard supplied handles shown in 1/4" panel position.
Overlay Panels
You may also choose to install custom overlay panels from your cabinet manufacturer. This design provides a seamless appearance which integrates smoothly with surrounding cabinetry.
Door Handles
The supplied handles can be adjusted to accommodate both framed or overlay panels. Custom handles of your choice, supplied by your cabinet maker, can also be installed. If desired, you may order ZKHSS2 Monogram stainless steel tubular handle kit for overlay panels.
Side Panels
Side panels must be used whenever the sides of the refrigerator will be exposed. The 1/4" side panels will slip into the side case trim. Secure the panels to the refrigerator with stick-on hook and loop fastener strips. Order the side panels from the cabinet manufacturer.
• Cut a notch in the top front corner as shown to allow clearance for corner keys in the front side trim.
Standard supplied handles shown in 3/4" overlay panel position.
For answers to your Monogram,® GE Profile™ or GE® appliance questions, visit our website at ge.com or call GE Answer Center® service,
800.626.2000.
*Depending on installation height.
Optional Accessory Kit
ZKHSS2: Tubular Stainless Steel handles designed to fit 3/4" overlay panels.
Accessory Panels
White or black acrylic and stainless steel accessory pan­els are available from your Monogram supplier. Panels are cut to size and ready to install. These panel kits must be ordered separately.
White Black Stainless Models Acrylic Acrylic Steel
ZISW480D ZPW480D ZPS480D ZISB480D ZPB480D ZPS480D
ZIS480N ZPW480N ZPB480N ZPS480N
Listed by Underwriters Laboratories
Specification Created 3/08
As an ENERGY STAR® partner, GE has determined that this product meets the ENERGY STAR for energy efficiency.
guidelines
110180
ZISW/B480DX
Fresh
Food
Freezer
Panel
D
F
G
A
B
Grille Panel
C
Dispenser
Cutout
E
9-5/8"
Dispenser Cutout
15-3/8"
3/4"
Overlay
Panel
Door
.10"
Spacer
1/4"
Backer
Panel
Spacer Panel
Overlay Panel
Backer Panel
1/4" Backer Panel
3/4" Overlay Panel
Wide Middle Rail is
Required
Dispenser
Trim
16-3/4"
10-5/8"
.10" Spacer
GE Monogram® 48" Built-In Side-by-Side Refrigerator with Dispenser and Water Filter
Dimensions and Installation Information (in inches)
3/4" Overlay Panel Dimensions
For a more custom appearance, overlay panels may be installed on trimmed models. The overlay panel must be secured to a 1/4"-thick backer panel which slides into the trim. A spacer panel 0.10" thick must be placed between the overlay and backer panels.
.250" + .10" + .750" =
1.100" Total Panel Thickness
Center each panel over the other. Assemble the panels with glue and screws. Screws must be countersunk into the backer panel.
NOTE: Left-to-right offset is not always equal to top-to-bottom offset.
Raised Overlay Panel Design On Dispenser Models
When a raised panel design is to be used, a custom wide middle rail is required to accept the dispenser trim.
• The middle rail must be wide enough to allow for the dispenser trim to overlap the opening.
• The middle rail must be 1.100" total thickness to accept the dispenser trim.
Side View
For answers to your Monogram,® GE Profile™ or GE® appliance questions, visit our website at ge.com or call GE Answer Center® service,
800.626.2000.
48" Side-by-Side (in inches)
A B C D E
1/4" Backer Panel 45-7/8 9-1/2 68-3/8 18-9/16 26-9/16 .10" Spacer Panel 45 8-5/8 67 17-1/4 25-1/4 3/4" Spacer Panel 46-1/8 9-3/4 68-5/8 18-13/16 26-13/16
*Dispenser Cutout Position (in inches)
F G
48" Models 17-15/16 5-1/4
* Cut the dispenser opening after the backer, spacer and
overlay panels have been assembled.
Important Note: Maximum total panel weight:
• Fresh food door panel – 75 lbs.
• Freezer door panel – 53 lbs.
• Grille panel – 18 lbs.
Listed by Underwriters Laboratories
Specification Created 3/08
As an ENERGY STAR® partner, GE has determined that this product meets the ENERGY STAR for energy efficiency.
guidelines
110180
Loading...
+ 4 hidden pages