GE AZ85E09DAC User Manual

AZ85E09DAC
GE® Vertical Packaged Terminal Air Conditioner
Dimensions and Installation Information (in inches) Minimum Clearances:
Front
• Allow 4 inches in front of unit. When determining closet depth, note that plenum may protrude into closet up to 4 inches, depending on exterior wall depth.
Sides
• Allow 3 inches on each side of unit.
• For side access closets only: Allow 5 inches clearance to front of unit.
Platform
An 8”-12” high, field-supplied platform is recommended for drain access.
230/208 Volt
Power Connection Kit RAK3152 RAK3202 RAK3302
Heater KW 2.55/2.09 3.45/2.83 5.00/4.10
Min. Circuit Amps 15 20 30
Recommended
Protective Device
15 Amp Time Delay
Fuse or Breaker
Line Cord Connected Units
20 Amp Time Delay
Fuse or Breaker
30 Amp Time Delay
Fuse or Breaker
32 1/4” H
23 1/8” W
23 1/8” D
For answers to your Monogram,® GE Profile™ or GE® appliance questions, visit our website at ge.com or call GE Answer Center® service,
800.626.2000.
ZONELINE® WARRANTY
*
WHAT IS COVERED
FULL ONE-YEAR WARRANTY
For one year from date of original
purchase, we will provide, free of charge, parts and service labor on
site to repair or replace any part of the Zoneline that fails because
of a manufacturing defect.
ADDITIONAL FOUR-YEAR WARRANTY
For an additional four years from
the date of original purchase, we will provide, free of charge,
parts and on-site service labor to repair or replace any part of the
sealed refrigerating system (the
compressor, condenser, evaporator
and all connecting tubing) that
fails because of a manufacturing defect.
*SEE WRITTEN WARRANTY FOR DETAILS
LIMITED 2ND THROUGH 5TH YEAR PARTS WARRANTY
For the second through the fifth year from date of original purchase, General Electric will provide, free of charge, parts that fail as a result of a
manufacturing defect. Parts
covered are fan motors, switches, heater, heater protectors,
compressor overload, solenoids,
circuit boards, auxiliary controls,
thermistors, frost controls, capacitors and varistors. This is a
limited parts-only warranty, and does not include labor or transportation
to and from the service shop.
All warranty service will be provided by our Factory Service
Centers or by our authorized
Customer Care
during normal working hours.
®
servicers
Specification Created 1/10
390631
AZ85E09DAC
Closet Door
GE® Vertical Packaged Terminal Air Conditioner
Features and Benefits
• 9,500/9,300 BTUH Cooling Capacity
• 10.5/10.5 E.E.R. (BTUH/Watt)
• R-410A Refrigerant
• Vertical Design Optimizes Floor Space—Unique Sleeve Design Makes It Easier to Install
• Freeze Sentinel™ Protects Unoccupied Rooms Against Freeze-Up
• Three-Way, Slide-Out Chassis with Specially Designed Case Makes
Maintenance and Service Quick and Easy
• Full Corrosion Treatment on Outside Coils and Other Components
is Standard
For answers to your Monogram,® GE Profile™ or GE® appliance questions, visit our website at ge.com or call GE Answer Center® service,
800.626.2000.
Specification Created 1/10
390631
Loading...