AZ65H12EBM
SIDE
VIEW
Room
Cabinet
Outside
Grille
7-1/8
RAB71A = 16
RAB77A = 16-1/4
RAB71A = 20-7/8
RAB77A = 21
A
C
B
Zoneline RAC Wall Installation
GE Zoneline® Heat Pump Unit with Makeup Air, 265 Volt
DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)
ELECTRICAL WIRING
All wiring, including installation of receptacle, must
be made in accordance with local electrical codes
and regulations.
NOTE: Aluminum wiring may pose special problems – consult a
qualified electrician.
GRILLE OPTIONS
Stamped Aluminum Grille – RAG60
Exterior Architectural Louvers Durable Polycarbonate:
RAG61 (Beige) RAG63 (Dark Brown)
RAG62 (Maple)
Extruded Aluminum Architectural Grille – RAG67
RETROFIT KITS:
RAK40 – Deflector Kit to adapt chassis for use with
existing (non-GE) exterior louvered grilles.bnn
ELECTRICAL CONNECTION
265 volt units are provided with a junction box and require direct
connection or permanent direction per NEC. See Architects and
Engineers Design Data Manual for electrical connection information
including use of sub-base for direct connected units. Installation must
comply with local electrical codes and regulations.
Power connection kits are required on all Zoneline chassis.
WALL CASE DIMENSIONS
RAB71B WALL SLEEVE
Heavy-gauge galvanized steel,
with insulation.
A – 42", B – 13-3/4", C – 16"
Also available in 16" and 24"
depths
RAB77B WALL SLEEVE
Molded SMC fiberglass-
MAXIMUM CORD EXTENSION
21
WALL OPENING
DIMENSIONS
Add 1/4" to A and C dimensions
for all cut-outs.
RAB71B 16-1/4" Min. H x
42-1/4" Min. W
RAB77B 16-1/2" Min. H x
42-3/8" Min. W
reinforced polyester compound.
A – 42-1/8", B– 13-7/8",
C – 16-1/4"
265 VOLT SUB-BASE CONNECTED UNITS
POWER
SUB-BASE
RAK204E15 RAK515D 2,400 9.1 15
RAK204E20 RAK520D 3,400 12.9 20
RAK204E30 RAK530D 4,800 18.1 30
CONNECTION
KIT
ELECTRIC
HEAT E R
WATTS
ELECTRIC
HEAT AMP S
MIN. CIRCUIT
PROTECTION
58
(AMPS)
For more information, please visit our website at zoneline.com or call 888.231.2548.
Specification Revised 2/17
AZ65H12EBM
GE Zoneline® Heat Pump Unit with Makeup Air, 265 Volt
FEATURES AND BENEFITS
Makeup air - Delivers 25-50 CFM of continuous makeup air
whenever the room is occupied
Energy efficiency - When paired with occupancy sensing
hardware, ventilation can be halted during vacancy
Dehumidification - Dehumidifies at a rate of 5-6 pints per
24 hours (based on CFM level)
Boost heat option - Provides supplemental resistance heat
in heat pump mode
Heat & Freeze Sentinels - Keeps the room from overheating
or freezing
Electronic temperature limiting - Prevents expensive overcooling or over-heating of the room
Electronic touch controls with LED display
May reduce the need for individually ducted rooftop systems
Because makeup air increases room BTU load requirements
and requires additional PTAC cooling or heating, the
building’s electrical needs may be impacted
Makeup air models are not recommended for installation
within two miles of coastal areas
It is strongly recommended to install makeup air with wall
thermostats
SMC base pan
Simplified structure - Easy to maintain and service