GE AZ65H12DAD, AZ65H09DAB, AZ65H15DAB, AZ65H09EAC, AZ65H07DAD Instruction Manual

...
GE ZONELINE®
PACKAGED
TERMINAL AIR
CONDITIONERS
Product Guide
®
GE ZONELINE
A Story of American Invention
In 1961, the GE Zoneline® PTAC began making its way into hotels and
motels across the country, changing the face of comfort on the road.
Now, over 50 years later, GE Zoneline has been reinvented in Louisville,
Kentucky, to meet the changing needs of America’s hotel industry.
The newest GE Zoneline PTACs are engineered to be more reliable,
ecient, quieter and incredibly easy to install and maintain.
2
KEY BENEFITS
GE Zoneline is an industry leader in four categories:
RELIABLE
QUIET
EFFICIENT
APPEARANCE
3
4
RELIABLE
With over one million units installed across the U.S., and with remarkably low service issues, GE
Zoneline
UNMATCHED SERVICE & SUPPORT
Our technicians service your Zoneline—and any other GE appliances you have—in no time,
so guest comfort is not compromised.
FEATURE HIGHLIGHTS:
SIMPLIFIED STRUCTURE | Easy to maintain and service.
PREMIUM GUARD CORROSION PROTECTION | Special coatings keep
each part performing at peak condition, longer.
PTACs oer unrivaled reliability, consistent performance and constant guest comfort.
EASY TO SERVICE | Zonelines have integrated structural components for easy maintenance and support.
DURABLE DESIGN | Rustproof base pan comes standard on all models.
SERVICE DIAGNOSTICS PORT | Technicians can quickly diagnose problems.
QUICK CONNECT | The thermostat, central desk control and external fan
can be connected in seconds for faster installation and servicing.
5
6
QUIET
Quiet operation is a strong suit of GE Zoneline®. It's the industry's quietest PTAC*, so you know
your guests will always get a good night’s rest.
WHERE IT COUNTS
Typical outdoor noises such as those from trac or airports present challenges to hotel owners every
day. When tested against leading competitors, GE Zonelines block the most outdoor noise with a sound
transmission class of 29
sleep better and can support high guest ratings for hotel and motel properties.
*
—that’s the highest PTAC STC on the market. That means Zonelines help guests
BEST STC
against leading competitors*
(Sound Transmission Class)
Stand ard on all units. Higher is better.
Guests who are dissatisfied with the room noise or temperature:
29
%
33
ARE NOT LIKELY TO RECOMMEND
THE HOTEL**
GE
ZONELINE
FEATURE HIGHLIGHTS:
BAKED-ON MASTIC SOUND BARRIER | A heavy-duty barrier covers the back of the unit for superior
sound insulation.
WEATHER BARRIER SYSTEM SEAL | A seal around the perimeter of the unit keeps noise and dirt outside.
TWO DC FAN MOTORS | A motor for each fan reduces noise by dialing in the exact airflow needed for each
heating and cooling function.
LARGE CROSS-FLOW BLOWER | Airflow is optimized for a low, balanced sound that is hardly noticeable.
SMART FAN COOLING/HEATING | Allows the fan to run in either continuous mode during hot weather
or cycle mode during the winter months, saving energy and improving guest comfort.
AMANA
Q SERIES
LG AMANA
FRIEDRICH
GE Appliances Zonelines provide quiet comfort for hotel rooms.
ARE NOT LIKELY
TO RETU RN TO
THE HOTEL**
66
%
* When comp ared to leading competi tors. 12,000 BTUh he at pump model s tested by independent third-party t esting at a national a coustical l ab, conducted March 2015 and
Octobe r 2015, in accordan ce with ASTM and AHRI standards. Th e higher the STC rat ing, the better the unit bl ocks outsid e noise.
** C larabridg e Ratings and Reviews, for hospitality data collected Ju ly 2013 – June 2014. “Americans' bi ggest complaints about hotels” Forb es Magazine, July 27, 2012 issu e.
7
8
EFFICIENT
GE Zoneline® PTACs are highly ecient. Zoneline heat pumps can save a property hundreds of dollars
per month in utility expenses.
*
On average Zoneline is 7% more ecient than the leading competitor.
WHY IT MATTERS
Decreasing the energy usage of your properties can save you a lot of money.
Since Zoneline PTACs are one of the industry leaders in ecient operation,
you’ll be able to cut utility bills without compromising comfort.
FEATURE HIGHLIGHTS:
REVERSE CYCLE DEFROST | Prolongs heat pump operation, saving
energy and money.
**
ELECTRONIC TEMPERATURE LIMITING | Limits are preset to save energy and avoid excessive temperature swings.
HEAT & FREEZE SENTINELS | Specially designed sentinels protect your property by preventing overheating or freezing.
EXTENSIVE HEAT SOURCE LOGIC | Smart technology lets each unit automatically select the right heat source to eciently meet guest needs.
SMART PROGRAMMING | Every unit is programmed to balance guest comfort with ecient operation.
*Savings depen d on region, equipment, st ructure and oth er factors. ** Zoneline AZ45 and AZ65 ser ies base mod els, average for EER & COP ratings
per AHR I listing May 2016. E ciency benefits may v ary by model an d region.
9
10
APPEARANCE
GE Zoneline® boasts a slim room front, sleek appearance and light color that blends in seamlessly
with any hotel décor and room design. With an industry-standard 42" x 16" cutout and the industry’s
slimmest room front, Zoneline provides more open, usable space in the room itself.
STREAMLINED, INSIDE AND OUT
Zoneline is sleek on the outside, and is also more eciently engineered inside.
FEATURE HIGHLIGHTS:
BACKLIT, COVERLESS CONTROL PANEL | Attractive display with large, white LED lights
and no control panel cover keep this unit looking like new.
SLEEK APPEARANCE | 42" x 16" cutout with a shallow depth provides more usable room space.
LIGHT COLOR | Perfectly blends in with modern interior designs.
DIMMING DISPLAY | Automatic dimming feature makes sure LED lights are never too bright at night.
11
FEATURE HIGHLIGHTS
GE Zoneline® has a legacy of energy eciency and guest comfort, thanks to innovative features that property managers love.
PREMIUM GUARD CORROSION PROTECTION
Special coatings, paintings and stainless steel ensure lasting performance in challenging environments such as oceanfront properties.
*
BAKED-ON MASTIC SOUND BARRIER
A heavy-duty barrier covers the back of the unit for superior sound insulation.
MAKEUP AIR*
An included secondary system provides continuous outdoor air. The supplemental dehumidification system operates when relative humidity levels rise above 55%. Available on select models.
INTERNAL CONDENSATE REMOVAL (ICR)*
A system of drainpipes and pump minimizes the amount of condensate draining from the unit when in heat pump mode.
DRY AIR 25
Zoneline Dry Air models remove 20%-35% more moisture from the air than standard Zoneline air conditioners**, making them perfect for high humidity climates.
*Available on select m odels. ** Varies w hen comparin g dehumidific ation rates of the 7,000/9,000/12,000BTU
base m odels to their D ry Air model counterparts. AZ 45 Series elect ric resistan ce models onl y.
12
*
SYSTEM COMPATIBILITY
Compatible with a wide variety of thermostats and energy management systems, including central desk control.
BLOWER & DC MOTORS
Large cross-flow blower, two DC fan motors and smart fan cooling and heating keep the unit quiet while providing ecient heating and cooling performance.
HEAT PU M P F EATUR E S
Reverse cycle defrost increases eciency and allows unit to run in heat pump mode longer.
Backup resistance heat delivers quick heating comfort.
HEAT & FREEZE SENTINEL
Keeps room from overheating or freezing to increase eciency and comfort while decreasing operating and maintenance costs.
WEATHER BARRIER SYSTEM SEAL
Keeps noise, dirt and grime outside.
Creates a quieter room and more ecient operation.
ELECTRONIC TOUCH CONTROLS
Easy-to-use controls with clear LED readout provide a user-friendly experience.
ELECTRONIC TEMPERATURE LIMITING
Prevents expensive overcooling and overheating of rooms.
Limits are automatically set, so seasonal adjustments aren’t necessary.
13
ZONELINE® PACKAGED TERMINAL AIR CONDITIONERS
AZ45 SERIES | COOLING AND ELECTRIC HEAT
• Digital LED display
• Variable vent control
• Quiet fans, blowers and
motors: – Cross-flow blower – Two DC fan motors – Smart fan cooling
• Heat and Freeze Sentinel
• Remote thermostat
capability
• Electronic temperature
limiting
• Works with central desk
control and remote thermostats
BASE PREMIUM GUARD CORROSION PROTECTION DRY AIR 25
AZ45E07DAB
7,200/7,000 BTU
13.4/13.4 EER
230/208 Volts
AZ45E09DAB
9,700/9,600 BTU
12.1/12.1 EER
230/208 Volts
AZ45E12DAB
11,900/11,800 BTU
11.8/11.8 EER
230/208 Volts
AZ45E15DAB
14,900/14,800 BTU
10.5/10. 5 EER
230/208 Volts
AZ65 SERIES | HE AT P U MP
Includes all resistant heat
features, plus:
• Staged heating
• Heat pump with supplemental resistance heat
• Reverse cycle defrost
BASE PREMIUM GUARD CORROSION PROTECTION INTERNAL CONDENSATE REMOVAL
AZ65H07DAB
7,10 0/6, 900 cooli n g BTU, 6,200/6,100 heating BTU, 13.0/
13.0 EER, 4.0/4.0
COP*, 230/208 Volts
AZ65H09DAB
9,700/9,600 cooling BTU, 8,100/8,000 heating BTU, 12.2/
12.2 EER , 3.7/3.7
COP*, 230/208 Volts
AZ65H12DAB
12,100/11,900 cooling BTU, 10,500/10,400 heating BTU, 11.9/
11.9 EER, 3.6/3.6
COP*, 230/208 Volts
AZ65H15DAB
14,400/14,200 cooling BTU, 13,400/13,300 heating BTU, 10.6/
10.6 EER, 3.3/3.3
COP*, 230/208 Volts
AZ45E07DAC
7,200/7,000 BTU
13.4/13.4 EER
230/208 Volts
AZ45E09DAC
9,400/9,300 BTU
11.8/11.8 EER
230/208 Volts
AZ45E12DAC
11,800/11,600 BTU
11.5/11.5 EER
230/208 Volts
AZ45E15DAC
14,600/14,500 BTU
10.5/10. 5 EER
230/208 Volts
AZ65H07DAC
7,100/7,000 cooling BTU, 6,200/6,100 heating BTU, 13.0/
13.0 EER, 4.0/4.0
COP*, 230/208 Volts
AZ65H09DAC
9,700/9,600 cooling BTU, 8,100/8,000 heating BTU, 12.2/
12.2 EER , 3.7/3.7
COP*, 230/208 Volts
AZ65H12DAC
11,900/11,800 cooling BTU, 10,400/10,300 heating BTU, 11.7/
11.7 EER, 3.6/3.6
COP*, 230/208 Volts
AZ65H15DAC
14,500/14,200 cooling BTU, 13,500/13,300 heating BTU, 10.4/
10.4 EER, 3.3/3.3
COP*, 230/208 Volts
AZ45E07EAC
7,300 BTU
13.4 EER
265 Volts
AZ45E09EAC
9,500 BTU
11.6 EER
265 Volts
AZ45E12EAC
11,800 BTU
11.7 EER
265 Volts
AZ45E15EAC
14,900 BTU
10.7 EER
265 Volts
AZ65H07EAC
7,000 cooling BTU, 6,200 heating BTU,
12.8 EER, 3.9 COP*,
265 Volts
AZ65H09EAC
9,500 cooling BTU, 8,100 heating BTU,
11.7 EER, 3.6 COP*,
265 Volts
AZ65H12EAC
11,900 cooling BTU, 10,500 heating BTU,
11.6 EER, 3.6 COP*,
265 Volts
AZ65H15EAC
14,500 cooling BTU, 13,500 heating BTU,
10.6 EER, 3.3 COP*,
265 Volts
AZ45E07DAP
6,900/6,800 BTU
12.8/12.8 EER
230/208 Volts
AZ45E09DAP
9,400/9,300 BTU
12.1/12.1 EER
230/208 Volts
AZ45E12DAP
11,200/11,100 BTU
11.5/11.5 EER
230/208 Volts
AZ65H07DAD
7,000/6,900 cooling BTU 6,200/6,000 heating BTU
13.0/13.0 EER
4.0/4.0 COP*
230/208 Volts
AZ65H09DAD
9,600/9,500 cooling BTU 8,200/8,000 heating BTU
12.0/1 2.0 EER
3.6/3.6 COP*
230/208 Volts
AZ65H12DAD
11,800/11,600 cool ing BTU 10,400/10,200 heating BTU
11.5/11.5 EER
3.5/3.5 COP*
230/208 Volts
AZ65H15DAD
14,300/14,100 cooling BTU 13,500/13,400 heating BTU
10.3/10.3 EER
3.2/3.2 COP*
230/208 Volts
AZ45E09EAP
9,500 BTU
12.1 EER
265 Volts
AZ45E12EAP
11,000 BTU
11.0 EER
265 Volts
AZ65H07EAD
7,000 cooling BTU 6,200 heating BTU
12.8 EER
3.9 COP*
265 Volts
AZ65H09EAD
9,500 cooling BTU 8,100 heating BTU
11.7 EER
3.5 COP*
265 Volts
AZ65H12EAD
11,900 cooling BTU 10,300 heating BTU
11.7 EER
3.4 COP*
265 Volts
AZ65H15EAD
14,300 cooling BTU 13,500 heating BTU
10.4 EER
3.2 COP*
265 Volts
*Coecient of Performance
14
AZ45 SERIES | RESISTANT HEAT MAKEUP AIR
AZ65 SERIES | HEAT PUMP MAKEUP AIR
• Delivers 35 CFM of continuous, makeup air
• Conditions incoming air when relative
humidity outdoors is above 55%
• Quiet operation – Baked-on mastic – Cross-flow blower – Two DC fan motors
• Heat & Freeze Sentinels
• Electronic temperature limiting
• Electronic touch controls with LED display
MAKEUP AIR
AZ45E09DAM
9,200/9,100 BTU
11.5/11.5 EER
230/208 Volts
AZ45E12DAM
11,600/11,500 BTU
11.4/11.4 EER
230/208 Volts
• May reduce the need for rooop units
• Product is built to order
NOTE: Because makeup air increases room BTU load
requirements and requires additional PTAC cooling or heating, the building’s electrical needs may be impacted.
ZONELINE® ACCESSORIES
Includes all resistant heat makeup air features, plus:
• Reverse heat cycle
• Boost heat option
MAKEUP AIR
AZ65H07DAM
6,700/6,600 cooling BTU, 6,100/6,000 heating BTU, 12.0/
12.0 EER, 3.6/3.6
COP*, 230/208 Volts
NOTE: Makeup air models listed above
are not recommended for installation within two miles of coastal areas.
AZ65H09DAM
9,200/9,100 cooling BTU, 8,100/8,000 heating BTU, 11.5/
11.5 EER, 3.5/3.5
COP*, 230/208 Volts
AZ65H12DAM
11,500/11,400 cooli ng BTU, 10,400/10,300 heating BTU, 11.2/
11.2 EER, 3.5/3.5
COP*, 230/208 Volts
NOTE: It is strongly recommended to
install makeup air with wall thermostats.
WALL CASE OPTIONS
RAB71B, RAB77B
Extended sleeves also available in 16" and 24" depths
GRILLE OPTIONS
Architectural rear grille
Extrud ed aluminum – Stamped a luminum – RAG60
High-impact polymer grille
STANDARD SUB-BASE WITH POWER CORD INCLUDED
RAK204D15C-15 Amp RAK204D20C-20 Amp RAK204D30C-30 Amp
ADDITIONAL ACCESSORIES AVAILABLE
RAG67
Beige – RAG 61 Maple – RAG62 Dark Brown – RAG63
RETROFIT KITS
RAK40 Deflector kit
THER M O S TAT S
AZ45 SERIES
RAK164D2
Cooling with electric heat digital remote thermostat
RAK164F2
Digital two fan speed thermostat for electric resistance
RAK164P2
Cooling with electric heat programmable remote thermostat
AZ65 SERIES
RAK148D2
Heat pump digital remote thermostat
RAK148F2
Digital two fan speed thermostat for heat pump
RAK148P2
Heat pump programmable remote thermostat
For example, drain kits, adapter, exterior air deflector kits and filters. Visit Zoneline.com for full listing.
15
POWER CONNECTION KITS ARE REQUIRED ON ALL GE ZONELINE CHASSIS.
The correct kit for the installation is determined by the voltage and amperage of the electrical circuit and the means of connecting the unit to the building wiring. If the unit is to be plugged into a receptacle, a line cord kit would be used; if the unit is to be permanently connected, a permanent connection kit would be used. Cord set units of 265 volts must be installed in compliance with National Electrical Code.
POWER CONNECTION KITS
Required on all models. See specification information below for heater kWh and branch circuit ampacity.
®
(See chart below)
RAK315P/320P/330P
230/208 volt line cord connection kit
Also available with short power cords
RAK315D/320D/330D
230/208 volt universal power supply kit
RAK515D/520D/530D
265 volt universal power supply kit
Receptacles/Sub-bases
Tan dem
230/20 8V 15 Amp
NEMA6 -15R
Perpendicular
230/20 8V 20 Amp
NEM A6-2 0R
Large tandem
230/20 8V 30 Amp
NEMA6-30R
265V 15 amp
NEMA7-15R;
recept acle use d on
265V sub-base
GE ZONE LI N E SPECIF I C AT I O N S — HEATE R WATTAG E
BTUh size 7,000/9,000 12,000/15,000
Power connection kit Tot al wa tt s 2,41 0/1, 990 3,42 0/2,8 30 4,830/3,990* 2,430/2,020 3 ,45 0/2,8 60 4,860/4,020* Heater watts 2,40 0/1 ,96 0 3,4 00/2,7 80 4,800/3,930* 2,400/ 1,9 60 3, 400/ 2,780 4,800/3,930* Heater BTUh 8,100/6,6 00 11 ,600/9,400 16,300/13,400* 8,100/6 ,600 11,600/9,400 16,300/13,400* Total amps 10.5/9. 6 14.9/13 .6 21.0/ 19. 2 10.6/9.7 15.1/13 .8 21.2/19. 3 Min. circuit 15 20 30 15 20 30
Recommended protective device
BTUh size 7,000/9,000 12,000/15,000
Power connection kit Tot al wa tt s 2,440 3,450 4,850* 2,460 3 ,470 4,870* Heater watts 2,400 3,400 4,800* 2,400 3,400 4,800* Heater BTUh 8,100 11 ,600 16,300* 8,100 11,600 16,300* Total amps 9.1 12.9 18.1 9. 3 13.1 18.4 Min. circuit 15 20 30 15 20 30
Recommended protective device
Each li ne cord kit h as an integral Lea kage Cur rent Dete ction and Interr uption (LCDI) devi ce as requ ired by Nation al Elec trical C ode (NE C) and Un derwr iters La borator ies (UL) for units m anufa ctured a fter Aug ust 1, 2 004.
Specifications subject to change. Wall case and exterior grille are also required for new construction. *30 AMP heater wattage will be reduced in low fan operation
230/208-Volt Line -Cord Conn ected (P) and Direct Connec ted Un its (D)
RAK315P &
RAK315D
15 amp
time-delay fuse
or breaker
265-Volt Permanent (P, Cord Set) a nd Direct- Conn ected U nits (D)
RAK5 15P &
RAK515D
15 amp
time-delay fuse
or breaker
RAK3 20P &
RAK320D
20 amp
time-delay fuse
or breaker
RAK5 20P &
RAK520D
20 amp
time-delay fuse
or breaker
RAK330P &
RAK330D
30 amp
time-delay fuse
or breaker
RAK530P &
RAK530D
30 amp
time-delay fuse
or breaker
RAK315P &
RAK315D
15 amp
time-delay fuse
or breaker
RAK5 15P &
RAK515D
15 amp
time-delay fuse
or breaker
RAK3 20P &
RAK320D
20 amp
time-delay fuse
or breaker
RAK5 20P &
RAK520D
20 amp
time-delay fuse
or breaker
RAK330P &
RAK330D
30 amp
time-delay fuse
or breaker
RAK530P &
RAK530D
30 amp
time-delay fuse
or breaker
265V 20 amp
NEM A7-20 R;
recept acle use d on
265V sub-base
265V 30 amp
NEMA7-30R;
recept acle use d on
265V sub-base
16
ZONELINE PACKAGED TERMINAL AIR CONDITIONER SPECIFICATIONS
230/208V Models AZ45E07DAB AZ45E09DAB AZ45E12DAB AZ45E15DAB
Cooling BTUH 7,200/7,000 9,700/9,600 11,900/11,800 14,900/14,800 EER (BTU/Watt) 13.4/13.4 12.1/12.1 11.8/11.8 10.5/10.5 Dehumidification Pts/Hr 1.7 2.7 3.5 4.6 Refrigerant type R-410A R-410A R-410A R-410A CFM, indoor fan high 409 409 449 449 CFM, indoor fan low 250 280 270 300 Vent CFM (full open) 33 38 42 47 Power factor 96% 98% 98% 97% Sensible heat ratio @ 230 volts 70% 64% 60% 63% Cooling Watts 535/520 800/790 1,010/1,000 1,415/1,405 Cooling Amperes, F.L. 2.5/2.6 3.6/3.9 4.7/5.0 6.4/6.8 Amperes, L.R. 13.5 21.0 29.5 31.5 Weight (Net/Ship) 90/100 103/113 106/116 106/116
230/208V Models AZ45E07DAC AZ45E09DAC AZ45E12DAC AZ45E15DAC 265V Models AZ45E07EAC AZ45E09EAC AZ45E12EAC AZ45E15EAC
Cooling BTUH 7,200/7,000 9,400/9,300 11,800/11,600 14,600/14,500 Cooling BTUH 7,300 9,500 11,800 14,900 EER (BTU/Watt) 13.4/13.4 11.8/11.8 11.5/11.5 10.5/10.5 EER (BTU/Watt) 13.4 11.6 11.7 1 0.7 Dehumidification Pts/Hr 1.6 2.7 3.5 4.6 Dehumidification Pts/Hr 1.7 2.7 3.5 4.6 Refrigerant type R-410A R-410A R-410A R-410A Refrigerant type R-410A R-410A R-410A R-410A CFM, indoor fan high 409 409 449 449 CFM, indoor fan high 409 409 449 449 CFM, indoor fan low 250 280 270 300 CFM, indoor fan low 250 280 270 300 Vent CFM (full open) 33 38 42 47 Vent CFM (full open) 33 38 42 47 Power factor 96% 98% 98% 97% Power factor 95% 94% 97% 98% Sensible heat ratio @ 230 volts 74% 64% 60% 63% Cooling Watts 535/520 795/790 1,020/1,005 1,390/1,380 Cooling Watts 540 815 1,005 1,390 Cooling Amperes, F.L. 2.5/2.6 3.5/3.9 4.5/4.9 6.3/6.7 Cooling Amperes, F.L. 2.2 3.3 4.0 5.4 Amperes, L.R. 13.5 21 29.5 31.5 Amperes, L.R. 11.7 16.5 23.5 26.0 Weight (Net/Ship) 90/100 103/113 106/116 106/116 Weight (Net/Ship) 95/105 103/113 106/116 107/117
230/208V Models AZ45E07DAP AZ45E09DAP AZ45E12DAP 265V Models AZ45E09EAP AZ45E12EAP
Cooling BTUH 6,900/6,800 9,400/9,300 11,200/11,100 Cooling BTUH 9,500 11,000 EER (BTU/Watt) 12.8/12.8 12.1/12.1 11.5/11.5 EER (BTU/Watt) 12.1 11.0 Dehumidification Pts/Hr 2.3 3.4 4.2 Dehumidification Pts/Hr 3.5 4.2 Refrigerant Type R-410A R-410A R-410A Refrigerant type R-410A R-410A CFM, indoor fan high 320 370 360 CFM, indoor fan high 370 360 CFM, indoor fan low 230 280 270 CFM, indoor fan low 280 270 Vent CFM (full open) 40.0 44.0 44 Vent CFM (full open) 44 44 Power factor 96% 97% 98% Power factor 93% 97 % Sensible heat ratio @ 230 volts 61 % 58% 54% Cooling Watts 535/530 775/765 970/960 Cooling Watts 780 995 Cooling Amperes, F.L. 2.5/2.7 3.5/3.8 4.4/4.7 Cooling Amperes, F.L. 3.2 3.9 Amperes, L.R. 13.5 21.0 29.5 Heating Amperes 16.5 23.5 Weight (Net/Ship) 96/106 109/119 112/122 Weight (Net/Ship) 109/119 112/122
AZ45 series (typical) cooling with electric heat
AZ45 series cooling with electric heat (Premium Guard Corrosion Protection)
Sensible heat ratio @ 265 volts 72% 67% 61% 59%
AZ45 series cooling with electric heat (Dry Air 25)
Sensible heat ratio @ 265 volts 58% 54%
230/208V Models AZ45E09DAM AZ45E12DAM
Cooling BTUH 9,200/9,100 11,600/11,500 EER (BTU/Watt) 11.5/11.5 11.4/11.4 Dehumidification Pts/Hr 1.8 3.2 Refrigerant type R-410A R-410A CFM, indoor fan high 409 449 CFM, indoor fan low 280 270 Vent CFM (full open/) 35 35 Power factor 98% 98% Sensible heat ratio @ 230 volts 78% 69% Cooling Watts 800/790 1,010/1,005 Cooling Amperes, F.L. 4.8/5.1 5.8/6.1 Amperes, L.R. 21.0 29.5 Weight (Net/Ship) 122/132 125/135
AZ45 series cooling with electric heat (makeup air)
*Coefficient of Performance
Listed by Underwriters Laboratories
17
ZONELINE® PACKAGED TERMINAL AIR CONDITIONER SPECIFICATIONS
230/208V Models AZ65H07DAC AZ65H09DAC AZ65H12DAC AZ65H15DAC 265V Models AZ65H07EAC AZ65H09EAC AZ65H12EAC AZ65H15EAC
Cooling BTUH 7,100/7,000 9,700/9,600 11,900/11,800 14,500/14,200 Cooling BTUH 7,000 9,500 11,900 14,500 EER (BTU/Watt) 13.0/13.0 12.2/12.2 11.7/11.7 10.4/10.4 EER (BTU/Watt) 12.8 11.7 11.6 10.6 Dehumidification Pts/Hr 1.6 2.6 3 .7 4.8 Dehumidification Pts/Hr 1.5 2.5 3 .7 4.8 Refrigerant type R-410A R-410A R-410A R-410A Refrigerant type R-410A R-410A R-410A R-410A CFM, indoor fan high 409 409 449 449 CFM, indoor fan high 409 409 449 449 CFM, indoor fan low 250 300 300 290 CFM, indoor fan low 250 300 300 290 Vent CFM (full open) 38 40 45 44 Vent CFM (full open) 38 40 45 44 Power factor 96% 98% 98% 97% Power factor 95% 94% 97% 98% Sensible heat ratio @ 230 volts 73% 68% 62% 60% Cooling Watts 545/53 5 795/785 1,015/1,005 1,390/1,360 Cooling Watts 545 810 1,025 1,365 Cooling Amperes, F.L. 2.5/2 .7 3.6/3.9 4.5/4.9 6.2/6.7 Cooling Amperes, F.L. 2.2 3.3 4.0 5.3 Amperes, L.R. 13.5 21.0 29.5 31.5 Amperes, L.R. 11.7 16.5 23.5 26.0 Reverse cycle heat BTUH 6,200/6,100 8,100/8,000 10,400/10,300 13,500/13,300 Reverse cycle heat BTUH 6,200 8,100 10,500 13,500 Coefficient of Performance 4.0/4.0 3.7/3.7 3.6/3.6 3.3/3.3 Coefficient of Performance 3.9 3.6 3.6 3.3 Heating Watts 450/445 645/630 845/815 1,195/1,180 Heating Watts 460 655 875 1,195 Heating Amperes 2.1/2.2 2.9/3.1 3.8/4.0 5.4/5.7 Heating Amperes 1.9 2.8 3.5 4.6 Weight (Net/Ship) 98/108 106/116 104/114 108/ 118 Weight (Net/Ship) 98/ 108 104/114 104/114 109/119
230/208V Models AZ65H07DAD AZ65H09DAD AZ65H12DAD AZ65H15DAD 265V Models AZ65H07EAD AZ65H09EAD AZ65H12EAD AZ65H15EAD
Cooling BTUH 7,000/6,900 9,600/9,500 11,800/11,600 14,300/14,100 Cooling BTUH 7,000 9,500 11,900 14,300 EER (BTU/Watt) 13.0/13.0 12.0/12.0 11.5/11.5 10.3/10.3 EER (BTU/Watt) 12.8 11.7 11.7 10.4 Dehumidification Pts/Hr 1.6 2.6 3.7 4.8 Dehumidification Pts/Hr 1.5 2.5 3.7 4.8 Refrigerant type R-410A R-410A R-410A R-410A Refrigerant type R-410A R-410A R-410A R-410A CFM, indoor fan high 409 409 449 449 CFM, indoor fan high 409 409 449 449 CFM, indoor fan low 250 300 300 290 CFM, indoor fan low 250 300 300 290 Vent CFM (full open) 38.0 40.0 45.0 44.0 Vent CFM (full open) 38 40 45 44 Power factor 96% 98% 98% 97 % Power factor 95% 94% 97% 98% Sensible heat ratio @ 230 volts 73 % 68% 62% 60% Cooling Watts 535/530 800/790 1,020/1,005 1,385/1,360 Cooling Watts 545 810 1,015 1,375 Cooling Amperes, F.L. 2 .5/2.7 3.6/3.9 4.6/4.9 6.1/6.6 Cooling Amperes, F.L. 2.2 3.3 4.0 5.3 Amperes, L.R. 13.5 21.0 29.5 31.5 Amperes, L.R. 11.7 16.5 23.5 26.0 Reverse cycle heat BTUH 6,200/6,000 8,200/8,000 10,400/10,200 13,500/13,400 Reverse cycle heat BTUH 6,200 8,100 10,500 13,500 Coefficient of Performance 4.0/4.0 3.6/3.6 3.5/3.5 3.2/3.2 Coefficient of Performance 3.9 3.5 3.4 3.2 Heating Watts 450/435 665/650 870/850 1,235/1,225 Heating Watts 460 670 885 1,235 Heating Amperes 2.1/2.2 3.0/3.2 3.8/4.1 5.3/5.6 Heating Amperes 1.9 2.8 3.5 4.6 Weight (Net/Ship) 100/110 108/118 106/116 110/120 Weight (Net/Ship) 98/108 104/114 104/114 111/121
AZ65 (typical) series heat pump with backup electric heat (Premium Guard Corrosion Protection)
Sensible heat ratio @ 265 volts 77% 68% 62% 60%
AZ65 series heat pump with backup electric heat (Internal Condensate Removal)
Sensible heat ratio @ 265 volts 77% 68% 62% 60%
230/208V Models AZ65H07DAB AZ65H09DAB AZ65H12DAB AZ65H15DAB
Cooling BTUH 7,100/6,900 9,700/9,600 12,100/11,900 14,400/14,200 EER (BTU/Watt) 13.0/13.0 12.2/12.2 11.9/11.9 10.6/10.6 Dehumidification Pts/Hr 1.7 2.6 3.7 4.8 Refrigerant type R-410A R-410A R-410A R-410A CFM, indoor fan high 409 409 449 449 CFM, indoor fan low 250 300 300 290 Vent CFM (full open) 38 40 45 44 Power factor 96% 98% 98% 97% Sensible heat ratio @ 230 volts 79% 68% 62% 60% Cooling Watts 545/530 795/785 1,015/1,000 1,355/1,335 Cooling Amperes, F.L. 2. 5/2.7 3.6/3.8 4.5/4.9 6.1/6.5 Amperes, L.R. 13.5 21.0 29.5 31.5 Reverse cycle heat BTUH 6,200/6,100 8,100/8,000 10,500/10,400 13,400/13,300 Coefficient of Performance 4.0/4.0 3.7/3.7 3.6/3.6 3.3/3.3 Heating Watts 450/440 645/630 850/840 1,190/1,180 Heating Amperes 2.1/2.2 3.0/3.2 3.8/4.0 5.2/5.6 Weight (Net/Ship) 98/108 104/114 104/114 107/117
230/208V Models AZ65H07DAM AZ65H09DAM AZ65H12DAM
Cooling BTUH 6,700/6,600 9,200/9,100 11,500/11,400 EER (BTU/Watt) 12.0/12.0 11.5/11.5 11.2/11.2 Dehumidification Pts/Hr 0.5 1.6 2.8 Refrigerant type R-410A R-410A R-410A CFM, indoor fan high 409 409 449 CFM, indoor fan low 250 300 300 Vent CFM (full open) 35 35 35 Power factor 98% 98% 98% Sensible heat ratio @ 230 volts 90% 80% 72% Cooling Watts 555/550 800/790 1,020/1,010 Cooling Amperes, F.L. 3.8/3.9 4.8/5.1 5.9/6.3 Amperes, L.R. 13.5 21.0 29.5 Reverse cycle heat BTUH 6,100/6,000 8,100/8,000 10,400/10,300 Coefficient of Performance 3.6/3.5 3.5/3.5 3.5/3.5 Heating Watts 485/480 670/655 860/840 Heating Amperes 3.4/3.6 4.3/4.5 5.2/5.4 Weight (Net/Ship) 117/127 123/133 123/133
AZ65 series heat pump with backup electric heat
AZ65 series heat pump with backup electric heat (makeup air)
Specifications subject to change.
Listed by Underwriters Laboratories
18
ZONELINE WARRANTY
FOR THE PERIOD OF
ONE YEAR
From the date of the original purchase
FIVE YEARS
From the date of the original purchase
GE APPLIANCES WILL REPLACE
Any part of the air conditioner which fails due to a defect in materials or workmanship. During this limited one-year warranty, GE will provide, free of charge, all labor and related service costs to
replace the defective part.
Sealed Refrigerating System, if any part of the Sealed Refrigerating System (the compressor, condenser, evaporator, and all connecting tubing) should fail due to a defect in materials or workmanship. During this limited ve-year warranty, GE will provide, free of charge, all labor and related service costs to replace the defective part.
SECOND THROUGH FIFTH YEAR
From the date of the original purchase
Fan Motors, Switches, Thermostat, Heater, Heater Protectors, Compressor Overload, Solenoids,
Circuit Boards, Auxiliary Controls, Thermistors, Freeze Sentinel, Frost Controls, ICR Pump, Capacitors, Varistors and Indoor Blower Bearing, if any of these parts should fail due to a defect in
materials or workmanship. During this additional four-year limited warranty, the customer will be responsible for any labor and related service costs.
ZONELINE CHASSIS NOMENCLATURE
AZ65H12DAD
Zoneline
Chassis series
45=cool/electric heat 65= heat pump
Unit type
E= cooling with electric
resistance heat
H= heat pump with electric
resistance heat
Nominal cooling capacity
07=7,000 BTUh cooling 09=9,000 BTUh cooling 12=12,000 BTUh cooling 15=15,000 BTUh cooling
Voltage/Phase/Frequency
D= 230/208 Volt, single
phase, 60 Hz
E= 265 Volt, single phase,
60 Hz
Visit Zoneline.com for more information.
Universal power connection
Special features
B=base unit C= Premium Guard
D= internal condensate
M=Makeup Air P=Dry Air 25
Corrosion Protection
removal (ICR) system (heat pump models only— not for coastal applications)
Listed by Underwriters Laboratories
19
GE is a trademark of the General Electric Company. Manufactured under trademark license.
Listed by Underwriters Laboratories
Appliance Park
Louisville, KY 40225
geappliances.com
zoneline.com
888.231.2548
Pub. No. 20-T0066 PC85111