GE AZ38H12D, AZ38H12DAD, AZ38H12DAB, AZ38H12DAC User Manual

GE Appliances
A
C
B
SIDE
VIEW
Room
Cabinet
Outside
58
21
Grille
7-1/8
RAB71A = 16 RAB77A = 16-1/4
RAB71A = 20-7/8 RAB77A = 21
AZ38H12D – GE Zoneline® Deluxe Series Heat Pump Unit
Wall Case Dimensions
Maximum Cord Extension (in inches)
RAB71 Wall Sleeve
Heavy-gauge galvanized steel, with insulation. A – 42", B – 13-3/4", C – 16"
RAB77 Wall Sleeve
Molded SMC fiberglass-reinforced polyester compound. A – 42-1/8", B– 13-7/8", C – 16-1/4
230/208 Volt Line Cord Connected Units
Line Cord
Kit
RAK3153 8,600/7,100 2,550/2,090 11.6/10.6 15 RAK3203 11,700/9,600 3,450/2,820 15.5/14.1 20 RAK3303 17,000/13,900 5,000/4,090 22.3/20.3 30
230/208 Volt Sub-Base Connected Units
Sub-Base
RAK204D15P 8,600/7,100 2,550/2,090 11.6/10.6 15
RAK204D20P 11,700/9,600 3,450/2,820 15.5/14.1 20
RAK204D30P 17,000/13,900 5,000/4,090 22.3/20.3 30
Specification Revised 4/06
390520
Electric Heat
(Btuh)
Electric Heat
(Btuh)
Electric
Heater Watts
Electric
Heater Watts
Electric
Heat Amps
Electric
Heat Amps
Min. Circuit
Protection
Min. Circuit
Protection
Wall Opening Dimensions
Add 1/4" to A and C dimensions for all cut-out size. RAB71 16-1/4" Min. H x 42-1/4" Min. W RAB71 available in 16", 24", 28" and 31" depths RAB77 16-1/2" Min. H x 42-3/8" Min. W
(Amps)
(Amps)
Electrical Wiring
All wiring, including installation of receptacle, must be made in accordance with local electrical codes and regulations.
Note: Aluminum wiring may pose special problems – consult a qualified electrician.
Grille Options
Stamped Aluminum Grille – RAG60 Exterior Architectural Louvers Durable Polycarbonate: RAG61 or RAG64 (Beige) RAG63 or RAG66 (Bittersweet) RAG62 or RAG65 (Maple) RAG67 (Extruded Aluminum)
Retrofit Kits:
RAK901L – Wall Case Insulation for use with heat pumps. RAK40 – Deflector Kit to adapt chassis for use with existing exterior architectural louvered grilles.
Ducted Applications
2800 and 3800 series can be used with ductwork to heat or cool more than one room. RAK6052 Duct Adaptor is applied to top of case over air discharge/RAK601 Duct Extension is applied to right or left of adaptor. Locally fabricated ductwork may be added to extend to maximum recommended distance of 15 feet.
Electrical Connection
230/208 volt units may be plugged into a receptacle. 265 volt units are provided with a junction box and require direct connection. (NEC Requires 265V Direct Connection) See Architects and Engineers Design Data Manual for electrical connection information including use of sub-base for direct connected units. Installation must comply with local electrical codes and regulations.
Power Connection kits required on all Zoneline chassis.
For answers to your Monogram,® GE Profile™ or GE® appliance questions, visit our website at ge.com or call GE Answer Center® service,
800.626.2000.
GE Appliances
AZ38H12D – GE Zoneline® Deluxe Series Heat Pump Unit
Features and Benefits
• 11,700/11,500 BTUH (Cooling)
• 11.5/11.5 E.E.R.
• 3.6 Dehumidification (pts/hr)
• 10,900/10,700 BTUH (Reverse Cycle Heat)
• 300/260 CFM Indoor Fan (High/Low)
• 75/45 Vent CFM
• Electronic 7-Step Temperature Limiting To Prevent Overcooling or Overheating of Room
• Heat Sentinel
• Reverse Cycle Heating
Specification Revised 4/06
390520
• 29 Sound Transmission Class (STC)
• Standard Microcomputer, Rotary Knobs
• Model AZ38H12DAB – Warm grey beige
• Model AZ38H12DAC – Warm grey beige (Corrosion Treated)
• Model AZ38H12DAD – Warm grey beige (Internal Condensate Removal)