Important Safety information
Operating Instructions
Oa_ o{ Predator
Installation Instructions
Helpful Information
Thi_gs Tha__Are
If SomethingGoesWrong
BeZoye Yow ...... _oywce
GE Serdce _w_mness
GEAnswer Center ®
800.626.2000
GEAppliances
49-7359
we believe in dependable service.
You'll see it in this easy-to-use manual and you'll hear it in the friendly voices of our customer service department.
the comff)rt of your Zoneline. That's important, because your new Zoneline will be part of your family for a long time.
Before using
yo_g
Zoneline
Staple your receipt to the inside back cover of this manual You will need it
to obtain service under warranty.
Write down the model and serial
numbers here. They are on a label
behind the room cabinet on the base pan.
Model number
Serial number
Date of purchase
ii _ il
Hglp 1is
help you
800.626.2000
2
Befi)re you call for service, there are a few things you can do to help us serve you better.
Read this manual It contains instructions to help you use and
maintain your Zoneline properly.
Save time and money. Check the section titled ff Something Goes
Wrong before calling. This section
was designed to solve common
problems that might occur.
If you do need service, you can relax knowing help is only a phone call away. Toll-free customer service
numbers are included in the back of this manual. Or call the GE
Answer Center ® at 800.626.2000,
24 hours a day, 7 days a week.
READ ALL SAFE TY INFORMA TION
BEFORE USING
This Zoneline must be properly Unplug or disconnect the installed in accordance with the Zoneline at the fuse box or
Installation Instructions before it circuit breaker before making is used. See pages 10-12.
any repairs.
Repair or replace immediately all electric service cords that have
become ficayed or otherwise damaged.
SAVE
THE SE INS TR UCTI ONS
For details see the Installation Instructions in the back of this
manual.
NOTE:We strongly recommend
that any servicing be pertbrmed
by a qualified individual.
3
The
controls
TEMP CONTROLS MODE CONTROLS
LOW
FAN
STOPt
HIGH
FAN
On yO! T
Zoneline
A TempControl
The temp control is used to maintain the room temperature. The compressor will cycle on and off to keep the room at the same level of comfort. When you turn the knob to COOLER
(blue) the indoor air will become cooler. Turn
the knob to WARMER (red) and the indoor air
will become warmer.
3200Series on/y
When the outdoor temperature is lower than 25°F., heat is provided by the electric heater in the air conditioner instead of by the heat pump.
LOW•
HEAT
HIGH
DLOW
COOL
HIGH
A Mode Control
HiGH COOLand LOW COOLprovide cooling with
different fan speeds.
HiGH HEATand tOW HEATprovide heating with different fan speeds.
LOW FAN or HIGH FANprovides air circulation and filtering without cooling or heating.
NOTE:
ff you move the switch from a cool or heat setting to STOP or to a fan setting, the unit has an automatic 3=minute delay before allowing the compressor to restart in the cool or heat mode.
EnergyTip
Vent
control
Louverscrews
Removethe room cabinet and
flip the louvers to change the air direction.
A Ventilation Control
The ventilation control lever is located at the
lower left side of the Zoneline unit, behind the room cabinet.
When set at CLOSE, only the air inside the room
is circulated and filtered.
When set at OPEN,some outdoor air will be
drawn into the room. This will reduce the heating or cooling egiciency.
Air Direction
To adjust the air direction, remove the room cabinet. Remove the 7 louver screws that
hold the louvers in place. Flip the louver section 180 °, replace the screws and the
room cabinet.
5
Other Zoneline features
Heat pumps can save money by removing heat from the outside
air-even when the outside temperature is below freezing-
and releasing that heat indoors.
To get the best performance from
your heat pump, don't change the
room thermostat vet y often. Raising the heat setting 2-3 degrees will cause the Zoneline to use its electric heating elements in order to reach the new temperature
setting quickly.
Additional controls are located
behind the room cabinet.
To remove: Pull out at the bottom to
There is a three minute minimum compressor run time at any setting
to prevent short cycling. The indoor fan motor starts before
the compressor and stops after the compressor cycles off.
The electric heating elements use much more electricity than heat pumps and cost more to operate.
To replace: Place the tabs over
the top rail. Push inward at the bottom until it snaps into place.
release it from the tabs. Then lift up.
The auxilia[ T controls are located behind the room cabinet on the front of the unit control box. The factory settings will be in the DOWNposition. The owner is responsible for checking switches and ensuring they are in the desired position.
123456
UP
DOWN
*All E UP:Fan cycle
DOWN:F RemoteCq
(Class 2)
*Not on Model 2200 Series
Load Shedding)
1B23456
IIaaaaIoow.
Auxiliary Controls
Down--Continuous Fan Up--Cycle Fan
123456
FIBFIBFIII]oowN
UP
UP
The fan switch #2 is located behind the room cabinet.
This switch is set at continuous fan
(DOWN) at the factory to provide
continuous fan operation in cool or heat modes. Leaving the switch in the continuous fan setting allows
continuous circulation of room air and will resuh in a more balanced
temperature throughout the room.
Switch #6 controls the Freeze Sentinel. When the switch is DOWN,
the Freeze Sentinel automatically turns on the resistance heater and
fan if the room temperature (sensed at the unit) drops to approximately
40 ° F. It will turn the heater offwhen the temperature reaches about 45 ° F.
The unit leaves the factory with the Freeze Sentinel in the DOWN
(on) position.
If you want the fan to cycle on and offwith the compressor or
with the heater, move the switch
to cycle fan (UP).
The Freeze Sentinel helps prevent plumbing damage in the room due to sub-freezing temperatures.
If the Freeze Sentinel is set, it is
active as long as power to the unit is on.
NOTE: The owner is responsible for checking the Freeze Sentinel switch and ensuring it is in the desired
setting. 7
&
Cleaning
Turn the Zoneline off and discon- nect the power supply.
The coils on the outdoor side of the Zoneline should be checked
regularly. If they are clogged with dirt or soot they may be profes- sionally steam cleaned, a seiMce available through your GE seiMce
outlet. You will need to remove the chassis to inspect the coils
because the dirt build-up occurs on the inside.
To clean, use water and a mild detergent. Do not use bleach or
abrasives. Some commercial cleaners may damage the plastic
parts.
Clean the outside coils regularly.
In some installations, dirt or other debris may be blown into the unit
from the outside and settle in the base pan (the bottom of the unit). In some areas of the United States a "jell-like" substance may be seen
in the base pan.
Check it periodically and clean it out, if necessai T.