Page 1

www. GEAppliances.com
Safety Information
Adapter Plugs .................... 3
Connect Electricity ............... 2
_tension Cords ................. 3
Safety I'recautions ................ 2
Operating lmtructions
Controls ...................... 4, 5
Care and Cleaning
Air Filter ........................ 6
Grille and Case ................... 6
Outdoor Coils ................... 6
ASP05
ASV05
AST05
AS706
©
Installation Imtructions
Preparing to Install the
Air Conditioner. ................. 7
Through the Wall
Installation-Optional ........... 12
Window Installation ........... 8-11
Troubleshooting Tips .......... 13
Nolrnal Operating
Sounds ......................... 13
ConsumerSupport
Consumer Support ..... Back Cover
Product Registration ......... 17, 18
Wananty ....................... 19
<
Writethemodeland serial
numbershere:
#
#
Find these numbers on a label on the
side of the air conditioner.
49-7399 JR 10-00
Page 2

IMPORTANTSAFETYINFORMATION.
READALLINSTRUCTIONSBEFOREUSING.
WARNING!
For your safety, the information in this manual must be followed to minimize the risk of fire, electric shock
or personal injury.
SAFETYPRECAUTIONS
"_: _ N Use this appliance only for its intended
purpose as described in this Owner's
Manual.
This air conditioner must be properly
installed in accordance with tile Installation
Instructions before it is used.
N Never unplug your air conditioner by pulling
on the power cord. Always grip plug firmly
and pull straight out from the receptacle.
N Repair or replace immediamly all elecUic
service cords that have become fi'ayed or
othelwise damaged. Do not use a cord that
shows cracks or abiasion damage along its
length or at either the plug or connector end.
HOWTOCONNECTELECTRICITY
Do not, under any circumstances, cut or remove
the third (ground) prong from the power cord. For
personal safety, this appliance must be properly
grounded.
N Tm'n the mode conU'ol OFFand unplug
your air conditioner before making any
repai1* or cleaning.
NOTE:We strongly recommend that any
servicing be pelfonned by a qualified
individual.
N For your safety...do not store or use
combustible mamrials, gasoline or other
flammable vapors or liquids in the vidnity
of this or any other appliance.
The air conditioner should always be
plugged into its own individual elecuJcal
outlet which has a voltage rating that matches
the rating plate.
The power cord of this appliance is equipped
with a 3-prong (,grounding) plugwhich mates
with a standard 3-prong (grounding) wall
outlet m minimize the possibility of electric
shock hazard fi'om this appliance.
Have the wall outlet and drcuit checked by a
qualified elecu'ician m make sure the oudet is
properly ,grounded.
Where a 2-prong wall outlet is encounmred,
it is yore" personal responsibility and obligation
m have it replaced with a properly gq'ounded
?_-prong wall outlet.
This provides the best peffommnce and also
prevents overloading house wiling circuits
which could cause a fire hazard fi'om
overheated *vires.
See the Installation Instructions, Electrical
Requirements section for specific elecUical
connection requirements.
2
Page 3

ZLWARNING!
USEOFEXTENSIONCORDS-775-Voltmodelsonly
www.GEAppliances.com
Because ofpotential safety hazards under certain
conditions, we strongly recommend against the
use of an extension cord.
However, ifyou must use an extension cord,
it is absolutely necessary that it be a UL-listed,
14 gauge, 3-wire gwounding type appliance
extension cord having a grounding type plug
and outlet and that tile electrical rating of tile
cord be 15 amperes (minimum) and 125 volts.
CAUtiON:
DO NOT use an extension cord with any of the
230/208 volt models.
USEOFADAPTERPLUGS-715-Voltmodelsonly
Because of potential safety hazards under certain
conditions, we strongly recommend against the use
of an adapter plug.
However, ifyou must use an adapter, where
local codes permit, a temporaryconnection may
be made m a properly gq'ounded 2-prong wall
outlet by use of a UL-listed adapter available at
most local hardware stores.
The lalger slot in the adapter must be aligned
with tile larger slot in tile wall outlet m provide
proper polarity in the connection of tile power
cord.
When disconnecting tile power cord fl'om the
adapter, always hold the adapter in place with
one hand while pulling the power cord plug
with the other hand. If this is not done, the
adapter ,ground teirninal is very likely m break
with repeated use.
If tile adapter gq'ound terminal breaks,
DO NOT USE tile air conditioner until a
proper ,ground has been established.
Attachingtheadapterground terminalto awall outlet
coverscrewdoesnot groundtheapplianceunlessthe
coverscrewis metal,andnotinsulated,and thewall
outlet isgroundedthroughthehousewiring. Youshould
havethecircuitcheckedbya qualified electricianto
makesuretheoutlet is properlygrounded
READANDFOLLOWTHISSAFETYINFORMATIONCAREFULLY.
SAVETHESEINSTRUCTIONS
3
Page 4

Aboutthe controlsontheair conditioner.
Features and appearance will vary.
LOW HI
FAN FAN
LOW__cFII i
COO OL
OFF
MEDCOOL
FAN 00L
HIGH@IIGH
LOW _EO
FAN COOL
OFF
LOW
COOL
O MODECONTROLS
Yourmodel will have one of the above type controls.
3 6
4 7 2 3 4
3 8 5
2 9
Io1Iol o l
2 7
O TEMPCONTROLS
Yourmodel will have one of the above type controls.
OFF
Controls
o Mode Controls
HIGH COOL,MED COOLand LOW COOLpr(Mde 0
cooling with different fan speeds.
LOWFANor HIGHFANprovides air circulation
and filtering without cooling,
NOTE:If youmovetheswitchfromacoolsettingtoOFForto
a fansetting,waitat least3 minutesbeforeswitchingbackto
acoolsetting.
Cooling Descriptions
ForNormal Cooling-Select HIGHCOOLor MED
COOLwith the temp control at midpoint,
ForMaximum Cooling-Select HIGHCOOLwith the
temp control at the highest number available on
your knob,
ForQuieter& NighttimeCooling-Select LOWCOOL
with the temp control at midpoint.
TempControls
3_e temp control is ttsed to maintain tfie
room temperature, The compressor will cycle
on and offto keep the room at the same level
of comfort, When you turn the knob to a
higher number tfie indoor air will become
cooler. Turn tfie knob I1)a lower number and
the indoor air will become warmer.
4
Page 5

Additional controls and important information.
Vent Control (on some models)
The vent control is located on 1he inside of the air
louvens in the lower light corner.
When set at CtOSE, only-the air inside 1he room will
be circulated and conditioned. When _t at OPEN,
some inside air isexhattsted outside.
Air Direction - Side-to-Side
On some models, the side-lo-side air direction is
adjusted by Ille louver levers or by gPasping and
moving the inner vertical louvers.
ww_.GEAppliances.com
r
TOopen the vent, push the lever to the right.
TOclose it,push it to the left.
Air Direction - Up and Down (on somemodels)
Fingertip pressure on the hork,_)ntal louvers a(l}usts
the air direction up or down.
OR
OR
5
Page 6

Careand cleaning of theair conditioner.
Grille and Case
Turn the air conditioner off and remove the plug To clean, use water and a mild detergent. Do not
from the wall outlet before cleaning, use bleach or abrasives.
OutdoorCoils
"lhe coils on the outdoor side of the air conditioner
should be checked regadarly. If they are dogged
with dirt or soot daey may- be professionally steam
cleaned, a service available through your GE
sel_ice outlet.
AirFilter
The air filter behind the front _ille should be
checked and cleaned at least every 30 (lays o1"more
often if necessaly.
Clean Ihe filter with walrn, soapy water. Rinse and
let the filter dry before replacing it.
CAUTION:DONOToperatetheairconditionerwithout
a filterbecausedirtandlintwill clogitandreduce
performance.
TOremove(onsomemodels):
[]()pen the inlet grille upward by pulling out the
bottom of the inlet grille.
[] Using the lab, pull up slightly-on the filter to
release it and pull it down,
TOremove (on some models):
i,, it_
i .llTdd
i_ i_
Grabthe tabson
thefilter andpull
it upandout.
Grabthetabon thefilter
andpull it totheright.
6
Page 7

Preparingtoinstall theair conditioner.
Read these instructions completely and carefully.
BeforeYou
NOTE TOINSTALLER:Leave these instructions with
the air conditioner after installation is completed.
NOTE TO CONSUMER:Keep this Owner's Manual
and Installation Instructions for future use.
IMPORTANT NOTES:
For personal safety, this air conditioner must be
properly grounded.
It is important to have the wall outlet and circuit
checked by a qualified electrician if there is any
doubt as to whether a proper ground exists.
Follow National Electric Codes (NEC)and/or local
codes and ordinances.
ElectricalRequirements
60 Hz grounded outlet protected with
_)me models require 115/120-voh a.c.
a 15-amp time delay-lla_ or circuit breaker.
The 3-prong grounding plug minimizes 1he
lX)ssibility of electric shock hazard. If the wall outlet
you plan m use is only a 2-prong outlet, it isyour
responsibility to have it replaced with a properly
grounded 3-prong wall outlet.
_ CAUTION:
_ DOnot, under any circumstances, cut or
i_ remove the third (ground) prong from the
power cord.
Do not change the plug on the power cord
of this air conditioner.
Aluminum house wiring may present
special problems--consult a qualified
electrician.
_)me models require 230/208-voh a.c.
©
prolected wifla a time delay- fuse or circuit
breaker. These models should be installed
on 111eirown single branch drcuit for best
perfolxnance and to prevent overloading
house or apartment wiring circuits, which
could cause a possible fire hazard from
overheating wires.
ToolsYouWillNeed
_; Phillips-head screwdriver
N Adjustable wrench
N Ruler or tape measure
U_Scissors or knife
_ Pencil
_ Level
7
Page 8

WindowInstallationInstructions.
Parts Included
Top mounting rail
w,22a
T°P me°_s_inpg rail gasKez_
accordion
Air
conditioner
Left
panel
Window
seal
Right
accordion
panel
TypeA(9) Type B (8)
Security bracket(3)
8
Page 9

Read completely, then follow step-by-step.
Window Requirements
These insu'uctions are for a stand_d double-
hung window. You will need to modify them for
other types of windows.
The air conditioner can be installed without
the accordion panels if needed to fit in a nan'ow
window. See the window opening dimensions
below.
I I
IB==4]
All supporting parLsmust be secured to filan
wood, masonry or metal.
The elecuical outlet must be within reach of the
Ix)wet cord.
Storm Window Requirements
A storm window frame will not allow flae air
conditioner m tilt rewards the outside and will keep
it from draining properly. To adjttst for this, attach a
piece of wood to the stool.
Wood
1/2" higher I'1
22" to36"
(Withaccordionpanels)
12W'rain.
I I
1T_6" min
(Withoutaccordionpanels)
WOODPIECES--
WIDTH:2"
LENGTH:Ixmg enough to fit inside the window
fl'ame.
THICKNESS:To demnnine the thickness, place a
piece of wood on the stool to make it 1/2" higher
than the top of the storm window flame.
Attach _curely with nails or screws provided by
the installer.
9
Page 10

WindowInstallationInstructions.
Prepare the Air Conditioner
[]Remove the backing from 1he top mounting
rail seal strip and attach it to the bottom of d,e
top mounting rail.
[] Install 1he top mounting rail with 3 lype A
screws fl'om the outside of flle case.
Topmountingrail _ _' _,
[] I*)osen the lower screw on each side of the case
and hook a _cmity bracket on each side.
Tighten the screws to secure the brackefs
in place.
Securitybracket
/
Securitybracket
[] Inserl the fl'ames of the accordion panels into
the top and bottom mounting rails. Attach the
accordion panels to the side of the case ttsing 6
type A screws.
Bottommountingrail
Topmountingrail
ga,-
Accordionpanels
10
Page 11

Install the Air Conditioner in the Window
] Cut the window sash seal to the window
width and stick the adhesive side to the
bottom of the sash.
Windowsashseal
] Place the air conditioner on the stool with
the bottom mounting rail against its back
edge. Center it and close the window
securely behind the top mounting rail.
It should be level or slightly- tilted to the
outside. Use a level; about a 1/3 bubble will
be the correct case slant to the outside.
] Extend the left and light accordion panels
to the vertical window sashes and attach
with 4 type B screws. Attach the top
mounting rail to the sash with a 1ype
B screw.
TypeBscrew
TypeB
SCreWS
Type B
screw
Attach the brackets to the stool on both
sides using two 1ype B screws.
screws
Install the Security Bracket and the Foam Top Window Gasket
[] A tlach a security bracket with a type B screw. [] Cut the foam top window gasket to the
window width.
[] Stuffthe foam belween the glass and the
window to prevent air and insects from getting
into the room.
[ I
llae inslallation is now complete.
11
Page 12

Throughthe Wall InstallationInstructions-OptionaL
Thecasemay beinstalled throughthe wall in bothexistingand new construction.
Readcompletely, then follow step-by-step.
IMPORTANT
Throughthewall installation is notappropriate
if anyof theside louversin the case will be
obstructedbythewall.
All side louversin thecasemustproject on the
outdoorside of thewall.
Theroomsideofthe case mustproject into the
roomat least 13/g"fromthe finished wall.
Thecasemustbe installedlevel fromside-to-side
and with a slighttilt fromfront to rear. Usea level;
abouta 1/2bubblewill be thecorrectcaseslantto
theoutside.
[]Remove the air conditioner from the case. I I
For specific instruction, refer to the Window '
InstallationInstructions.
[]Make certain a walt receptacle is available
close to the hole location or make
arrangements to install a receptacle.
[]Place the case in the wall opening and secure
with 12 1" long # 10 wood screws.
NOTE:Drill pilot holes, if necessary, for proper
installation. If the frame is oversized, use shims
to prevent case distortion.
I
i
i
Finish the Wall Open&g
Caulk all four sides on the outdoor side of the case to prevent moisture from getting through to the
interior walt. Use of flashing (drip rail) will further prevent water from dripping inside the wall and
down the outside of the building.
Piaster line
Lintel angle (tt required)_ I _//
Caulking f%---_-_ I Trim molding (if desired)
OUTSIDE
INSIDE
Air louvers
(must project on
the outdoor side
of the wall,)
Wood Filler and Caulkin,
(above & below the flashing)
.I Bottom rail
12
Flashing (Drip rail)
4,5cm (1314") min.
Page 13

Beforeyoucall for service.., ww_.GEAppliances.com
Troubleshooting tips."Save time and money! Review the chart below first and you may not need to call for service.
Possible Causes What ToDo
The air conditioner • Make sure the air conditioner plug is pushed
is unplugged, completely into the outlet.
The fuse is blown/circuit • Check the house fuse/circuit breaker }x)xand replace
breaker is tripped, the fuse or reset the breaker.
Power failure. • If power failure occurs, turn the air conditioner OFF.
When power is restored, wait 3 minutes to restart the
air conditioner to prevent nipping of the compressor
overk)ad.
Airflow is restricted. • Make sure there are no curtains, blinds or furnitm+e
blocking the front of the air conditioner.
The temp control may • Turn the temperafure knob to a higher number.
not be set correctly.
The air £dter is dirty. • Clean Ihe fiher at least eveiy 30 days.
See the OperatingInstructionssecdon.
The room may have been hot. • When Ihe air condiiioner is fil_t mined on you need m
Cold air is escaping. • Check for <)pen furnace floor registei_ and cold
Cooling coils have iced up. • See "A# conditioner freezing up" below.
Ice blocks the air flow • Set the mode control at HIGHFANor HIGHCOOLwith
and stops the air conditioner the temp at torZ
from cooling the room.
Excessively hot and • This is normal.
humid weather.
The air conditioner is not •Forproperwaterdisposal, makesuretheairconditioner
tilted to the outside, slantsslightly from the casefront to the rea,'.
Muisture is removed from
indoor air and drains into
blows it against the outdoor
rear of a cabinet where afan
condenser coil.
allow time for the room fo cool down.
air retui_qs.
• Set the air conditioner's vent to the closed position.
• This is normal for a short period in areas with little
humidity; non'nal for a kruger period in vely humid areas.
Normal Operating Sounds
_ You may hear a pinging noise caused t)y-wamr
being picked up and thrown ag-ainst the
condenser on rainy day-sor when the humidity is
high. This design feature helps remove moisture
and improve efficiency-.
_ You may hear the flaen'nostat click when the
compressor cycles on and off.
/TS_Water will collect in the base pan during
high humidity or on rainy days. The wamr
may overflow and drip from the outdoor side
of tim unit.
/TS_The fan may run even when the compressor
does not.
13
Page 14

m
"- Notes.
m
m
m
h
m
i__.
m
14
Page 15

Notes.
e.
_h
z_
e.
15
q
Page 16

m
"- Notes.
m
m
m
h
m
i__.
m
16
Page 17

GE Service Protection Plus TM
GE, a name recognized worldwide for quality and dependability, offers you
Service Protection Plus'_-comprehensive protection on all your appliances-
No Matter What Brand!
Benefits Include:
• Backed by GE
• All brands covered
• Unlimited service calls
• All parts and labor costs included
• No out-of-pocket expenses
• No hidden deductibles
• One 800 number to call
You will be completely satisfied with our serv-ice protection or you may request your money back
on the remaining value of your contract. No questions asked. It's that simple.
Protect your reffigeralor, dishwasher, washer and dlyer, range, "_, VCR and much more--any brand!
Plus there's no extra charge for emergency- service and low monthly financing is available. Even icemaker
coverage and food spoilage protection is offered. You can rest easy, knowing that all your valuable
household products are protected against expensive repairs.
Place your confidence in GE and call us in the U.S. toll-free at 800-626-2224
for more infon'nation.
All brands covered, up Io -0 )ears old, in the continenlM U.S.
........................................................................................... _Cul here
9
We'll CoverAny Appliance.
Anywhere. Anytime.*
Pleaseplace in envelopeand mail to:
General Electric Company
Warranty Registration Department
P.O. Box 32150
Louisville, KY 40232-2150
17
Page 18

Consumer Product Ownership Registration
Dear Customer:
Thank you for purchasing our product and thank you for placing your confidence in us,
We are proud to have you as a customer!
Follow these three steps to protect your new appliance investment:
.................................................................................................... _,_,,,_ ( ut here
Complete and mail
your Consumer
Product Ownership
Reg'tstration today.
Have the peace of
mind of knowing we
can contact yoll in the
unlikely event of a
safety modification.
Al}er mailing the
registration below,
store this docilnlent
in a sail: place. It
contains infbla_mtion
you will need should
you require smwice.
Our sen,ice number is
800 GE CARES
(800432-2737).
Model Number Serial Number
IIIIIIIIIII IIIIIII
Important: If you did not get a registration card with your
product, detach and return the form below to
ensure that your product is registered, or register
online at www.GEAppliances.com.
Consumer Product Ownership Registration
Read your Owner's
Manual caret]tlly.
It will help you
operate yollr new
appliance properly.
I I I I I I I I I I I I I I I I I
Model Number Serial Number
M_.[_ Ms.D M_s.D MissD
First] Ltsl ]
Name I I I I I I I I I Name I I I I I I I I I I I I
Sa-eet ]
Address I I I I I I I I I I I I I I I IIIIIII
Apt.# [ I I I I I I I E-mail Address
City [ [ I
Date Pla_ed
Month
General Electric Compan?
Loufsville, ge_ky
ww_GEAppliances, com
I I I I I I I I I I I State ]
Da} I_ Year _2_ Phone
Occasionally, we may allow selected companies to send you information.
D Check here if'you do not want this inlb_n_qation.
Nmnlu'r 1_ -]
G£dpplian_m
Zip I
Code I I I I I
I I I I I
18
Page 19

Air ConditionerWarranty.
All warranty service provided by our Factory Service Centers,
or an authorized Customer Care®technician. Toschedule service,
on-line, 24 hours a day, contact us at www.GEAppliances.com, or
call 800-GE-CARES.
We Will Replace:
Any part of the air condi fioner wlaich fails due to a defect in matelJals or workmanship.
Dufingthisfuflone-yearwarranty, wewillalsopro_de, freeofcharge, alllaL×)r
and in-home sel_-iceto replace the defective part.
Any part of the sealed refrigerating system (the compressor, condenser, evaporator
and all connecting tubing) which lails due to a defect in materials or workmanship,
Dufing this four-year additional warranty, we will also provide, free of charge, all laL×,r
and in-home sel_-iceto replace the defective part.
_ Service trips to your home to teach you how to use the
product.
_ Improper installation. If you have an installation problem,
or if the air conditioner is of improper cooling capacity
for the intended use, contact your dealer or installer.
You are responsible for providing adequate electrical
connecting facilities.
_ Failure of the product resulting from modifications to the
product or due to unreasonable use including failure to
provide reasonable and necessary maintenance.
_ In commercial locations labor necessary to move the
unit to a location where it is accessible for service
by an individual technician.
Staple your receipt here.
Proof of the original purchase
date is needed to obtain service
under the warran_
_ Replacement of house fuses orresetting of circuit
breakers.
_ Failure due to corrosion on models not corrosion-
protected.
_ Damage to the product caused byimproper power supply
voltage, accident, fire, floods or acts of God.
_ Incidental or consequential damage caused by possible
defects with this air conditioner.
This warranty is extended to the original purchaser and any succeeding owner for products purchased for home
use within the USA. In Alaska, the warranty excludes the cost of shipping or service calls to your home.
Some states do not allow the exclusion or limitation of incidental or consequential damages. This warranty gives
you specific legal rights, and you may also have other rights which vary from state to state. Toknow what your
legal rights are, consult your local or state consumer affairs office or your state's Attorney General
Warrantor: General Electric Company. Louisville, KY 40225
19
Page 20

ConsumerSupport.
GEAppliancesWebsite w_.GEAppliances.com
Have a question or need assistance with your appliance? '1"ty flae GE Appliances Websim 24 hom_ a day,
any day of the year! For grealer convenience and faster _rvice, you can now download Owner's Manuals,
order parts, catalogs, or even schedule _rvice on-line. You can also "Ask Our Team of Experls ......
your questions, and so much more**.
ScheduleService
Expert GE repair service is only one step away from your door. Get on-line and schedule your service at
your convenience 24 houL's any day ofthe year! Or cal1800-GE-CARES 80%432-2737) duringnom_at
business hom_.
w_.GEAppliances.com
RealLifeDesignStudio w_.GEAppliances.com
GE suppolis flae Univelsal Desigm concepf--products, services and environments flaat can be used by
people of all ages, sizes and capabilities. We recognize Ille need m design for a wide Fange of physical and
mental abilities and impairmenls. D)r details of GE's Universal Design applications, including kitchen
design ideas for people with disabilities, check out our Websim today. For the hearing impaired, please call
800-TDD-GEAC (800-833-4322).
ExtendedWarranties
) .....
I urchase a GE extended wan anty and learn about specml d_scounts that m'e avadable while yore wmTanty
is still in effect. You can purchase it on-line anytime, or call 800-626-2224 during normal business horns.
GE Consumer Home Serv ces _,allsull be there afmr your warranty expu es.
PartsandAccessories
w_.GEAppliances.com
w_.GEAppliances.com
Individuals qualified to _iwice their own appliances can have parts or accessories sent directly Io their homes
(VISA, MasterCard and Discover cards are accepted). Order on-line today, 24 hours every day or by phone at
800-626-2002 during nom_al business houL's.
Instructionscontainedinthismanualcoverprocedurestobeperformedbyanyuser.Otherservicinggenerally
shouldbereferredto qualifiedservicepersonnelCautionmustbeexercised,sinceimproperservicingmaycause
unsafeoperation.
ContactUs
If you are not satisfied with Ilae service you receive from GE, contact us on our Website with all tim details
including your phone number, or write to: General Manager, Cttsmmer Relations
GE Appliances, Appliance Park
Louisville, KY 4{)225
www.GEAppliances.com
RegisterYourAppliance w_.GEAppliances.com
Register your new appliance onqine--at your convenience! Timely product regisu'afion will allow for
enhanced communication and prompt service under the mnTlSof your wawanty, should Ihe need ari_.
You may also mail in Ilae pre-printed regisu_ation card included in the packing maferial, or detach and
u_ the fom_ in this Owner's Manual.
Printed in Korea