GE ASH10, ASH12 User Manual

Safety Instructions . . . . . . . . . .2, 3

Operating Instructions

Controls—Control Knobs . . . . .6, 7
Controls—Touch Pads . . . . . . .4, 5

Care and Cleaning

Air Filter . . . . . . . . . . . . . . . . . . . . .8
Batteries . . . . . . . . . . . . . . . . . . . . .8
Grille and Case . . . . . . . . . . . . . . .8

Installation Instructions

Through-the-Wall
Installation—Optional . . . . . . . .15
Window Installation . . . . . . . . .9–14
Troubleshooting Tips . . . . . . . .16
Normal Operating Sounds . . . . .16

Consumer Support

Consumer Support . . . . . . . . . . .20
Product Registration . . . . . . .17, 18
Warranty . . . . . . . . . . . . . . . . . . . .19
DB98-15879A 49-7472 12-03 JR
ASH08 ASW08 ASH10 ASH12
Air Conditioners
Owner’s Manual and
Installation Instructions
GEAppliances.com
Write the model and serial numbers here:
Model # __________________________
Serial # __________________________
Find these numbers on a label on the side of the air conditioner.
IMPORTANT SAFETY INFORMATION. READ ALL INSTRUCTIONS BEFORE USING.
WARNING!
For your safety, the information in this manual must be followed to minimize the risk of fire, electric shock or personal injury.
Use this appliance only for its intended
purpose as described in this Owner’s Manual.
This air conditioner must be properly
installed in accordance with the Installation Instructions before it is used.
Never unplug your air conditioner by pulling
on the power cord. Always grip plug firmly and pull straight out from the receptacle.
Repair or replace immediately all electric
service cords that have become frayed or otherwise damaged. Do not use a cord that shows cracks or abrasion damage along its length or at either the plug or connector end.
Turn the mode control OFF and unplug
your air conditioner before making any repairs or cleaning.
NOTE: We strongly recommend that any servicing be performed by a qualified individual.
For your safety…do not store or use
combustible materials, gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance.
All air conditioners contain refrigerants,
which under federal law must be removed prior to product disposal. If you are getting rid of an old product with refrigerants, check with the company handling disposal about what to do.
SAFETY PRECAUTIONS
Do not, under any circumstances, cut or remove the third (ground) prong from the power cord. For personal safety, this appliance must be properly grounded.
The power cord of this appliance is equipped with a 3-prong (grounding) plug which mates with a standard 3-prong (grounding) wall outlet to minimize the possibility of electric shock hazard from this appliance.
Have the wall outlet and circuit checked by a qualified electrician to make sure the outlet is properly grounded.
Where a 2-prong wall outlet is encountered, it is your personal responsibility and obligation to have it replaced with a properly grounded 3-prong wall outlet.
The air conditioner should always be plugged into its own individual electrical outlet which has a voltage rating that matches the rating plate.
This provides the best performance and also prevents overloading house wiring circuits which could cause a fire hazard from overheated wires.
See the Installation Instructions, Electrical Requirements section for specific electrical connection requirements.
HOW TO CONNECT ELECTRICITY
Consumer Support

Troubleshooting Tips Operating Instructions Safety InstructionsInstallation Instructions

2
3
Consumer SupportTroubleshooting TipsOperating InstructionsSafety Instructions Installation Instructions
GEAppliances.com
WARNING!
Because of potential safety hazards under certain conditions, we strongly recommend against the use of an extension cord.
However, if you must use an extension cord, it is absolutely necessary that it be a UL-listed, 14 gauge, 3-wire grounding type appliance extension cord having a grounding type plug and outlet and that the electrical rating of the cord be 15 amperes (minimum) and 125 volts.
CAUTION:
DO NOT use an extension cord with any of the 230/208 volt models.
USE OF EXTENSION CORDS—115-Volt models only
Because of potential safety hazards under certain conditions, we strongly recommend against the use of an adapter plug.
However, if you must use an adapter, where local codes permit, a temporary connection may be made to a properly grounded 2-prong wall outlet by use of a UL-listed adapter available at most local hardware stores.
The larger slot in the adapter must be aligned with the larger slot in the wall outlet to provide proper polarity in the connection of the power cord.
When disconnecting the power cord from the adapter, always hold the adapter in place with one hand while pulling the power cord plug with the other hand. If this is not done, the adapter ground terminal is very likely to break with repeated use.
If the adapter ground terminal breaks, DO NOT USE the air conditioner until a proper ground has been established.
Attaching the adapter ground terminal to a wall outlet cover screw does not ground the appliance unless the cover screw is metal, not insulated, and the wall outlet is grounded through the house wiring. You should have the circuit checked by a qualified electrician to make sure the outlet is properly grounded.
USE OF ADAPTER PLUGS—115-Volt models only
READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY.
SAVE THESE INSTRUCTIONS
4
Consumer Support
Troubleshooting Tips Operating Instructions Safety InstructionsInstallation Instructions
To ensure proper operation, aim the
remote control at the signal receiver on the air conditioner.
The remote control signal has a range of
up to 21 feet.
Make sure nothing is between the air
conditioner and the remote control that could block the signal.
Make sure batteries are fresh and installed
correctly—see the Care and Cleaning section.
About the controls on the air conditioner—models with touch pads.
Features and appearance will vary.
Air Conditioner Controls
Remote Control
ON/OFF
Turns air conditioner on and off.
Display
Shows the set temperature, time remaining on timer or fan speed (1–LOW, 2–MED or
3–HIGH).
MODE
Use to set the air conditioner to COOL or FAN mode.
Increase /Decrease Pads
Use to set temperature when in COOL mode.
FAN
Use to set the fan speed to LOW (1), MED (2) or HIGH (3).
TIMER
ON—When the air conditioner is off, it can
be set to automatically turn on in 1 to 12 hours at its previous setting. Each touch will set the time in hours.
OFF—When the air conditioner is on, it can be set to automatically turn off in 1 to 12 hours. Each touch will set the time in hours.
To cancel the timer, press the TIMER pad until the display time disappears.
Remote Control Signal Receiver
Remote Control
In the case of a power outage or interruption, the unit will automatically re-start in the settings last used after the power is restored. The TIMER feature
will reset to the original setting. You may need to set a new time if desired.
Power Outage Recovery Feature
Fan on
Cool on
Tim er on
The vent control is located on the inside of the air louvers in the lower right corner.
When set at CLOSE, only the air inside the room will be circulated and conditioned. When set at
OPEN, some inside air is exhausted outside.
Consumer SupportTroubleshooting TipsOperating InstructionsSafety Instructions Installation Instructions
GEAppliances.com
When the air conditioner is turned on, it will automatically start in the setting last used.
Vent Control (on some models)
To open the vent, push the lever to the right. To close it, push it to the left.
COOL Mode
Use the COOL mode with HIGH (3), MED (2) or LOW (1) fan for cooling. Use the INCREASE / DECREASE pads to set the desired temperature
between 64°F and 86°F in 1°F increments.
A thermostat is used to maintain the room temperature. The compressor will cycle on and off to keep the room at the set level of comfort. Set the thermostat at a lower number and the indoor air will become cooler. Set the thermostat at a higher number and the indoor air will become warmer.
NOTE: If the air conditioner is off and is then turned on while set to COOL, it will take approximately 3 minutes for the compressor to start and cooling to begin.
Cooling Descriptions
For Normal Cooling—Select the COOL mode
and HIGH (3) or MED (2) fan with a middle set temperature.
For Maximum Cooling—Select the COOL mode and HIGH (3) fan with a lower set temperature.
For Quieter & Nighttime Cooling—Select the COOL mode and LOW (1) fan with a middle set
temperature.
NOTE: If you switch from a COOL setting to OFF or to a fan setting, wait at least 3 minutes before switching back to a COOL setting.
Air Direction—Up and Down (on some models)
Fingertip pressure on the horizontal louvers adjusts the air direction up or down.
FAN Mode
Use the FAN at HIGH (3), MED (2) or LOW (1) to provide air circulation and filtering without cooling. Since fan only settings do not provide cooling, a temperature setting will not be displayed.
OR
Air Direction—Side-to-Side (on some models)
On some models, the side-to-side air direction is adjusted by the louver levers or by grasping and moving the inner vertical louvers.
OR
5
Consumer Support
Troubleshooting Tips Operating Instructions Safety InstructionsInstallation Instructions
6
About the controls on the air conditioner—models with control knobs.
Features and appearance will vary.
Controls
Mode Controls
HIGH COOL, MED COOL and LOW COOL provide
cooling with different fan speeds.
LOW FAN or HIGH FAN provides air circulation and filtering without cooling.
NOTE: If you move the switch from a cool setting to OFF or to a fan setting, wait at least 3 minutes before switching back to a cool setting.
Cooling Descriptions
For Normal Cooling—Select HIGH COOL or MED COOL with the temp control at midpoint.
For Maximum Cooling—Select HIGH COOL with the
temp control at the highest number available on your knob.
For Quieter & Nighttime Cooling—Select LOW COOL with the temp control at midpoint.
Temp Controls
The temp control is used to maintain the room temperature. The compressor will cycle on and off to keep the room at the same level of comfort. When you turn the knob to a higher number, the indoor air will become cooler. Turn the knob to a lower number and the indoor air will become warmer.
MODE CONTROLS
Your model will have one of the above type controls.
TEMP CONTROLS
Your model will have one of the above type controls.
OFF
LOW
FAN
LOW
COOL
HIGH
FAN
HIGH COOL
MED COOL
OFF
LOW
FAN
LOW COOL
HI
FAN
HI
COOL
LOW
COOL
LOW
FAN
OFF
MED COOL
3
2
HI
FAN
HI
COOL
5
4
1
6
7
8
9
10
45
3
2
1
34
6
7
8
2
1
5
6
Air Direction—Up and Down (on some models)
Fingertip pressure on the horizontal louvers adjusts the air direction up or down.
OR
Consumer SupportTroubleshooting TipsOperating InstructionsSafety Instructions Installation Instructions
7
GEAppliances.com
Additional controls and important information.
Vent Control (on some models)
The vent control is located on the inside of the air louvers in the lower right corner.
When set at CLOSE, only the air inside the room will be circulated and conditioned. When set at
OPEN, some inside air is exhausted outside.
Energy Saver (on some models)
The energy saver switch controls the fan.
ON —The fan and compressor cycle on and off together. This results in wider variations of room temperature and humidity. Normally used when the room is unoccupied.
OFF —The fan runs all the time, while the compressor cycles on and off.
This switch must be set at OFF in order to use the fan settings (on the mode control).
Air Direction—Side-to-Side
On some models, the side-to-side air direction is adjusted by the louver levers or by grasping and moving the inner vertical louvers.
CIRCULAIRE (on some models)
For fixed side-to-side air direction, set the Circulaire switch to ON until the desired air direction is obtained; then move it to OFF.
For continuous side-to-side air circulation, set the Circulaire switch to ON and leave it there.
OR
To open the vent, push the lever to the right. To close it, push it to the left.

Outdoor Coils

The coils on the outdoor side of the air conditioner should be checked regularly. If they are clogged with dirt or soot, they may be professionally steam-cleaned, a service available through your GE service outlet.

Grille and Case

Turn the air conditioner off and remove the plug from the wall outlet before cleaning.
To clean, use water and a mild detergent. Do not use bleach or abrasives.
Care and cleaning of the air conditioner.
Consumer Support
Troubleshooting Tips Operating Instructions Safety InstructionsInstallation Instructions
How to Insert the Batteries
Remove the battery cover by sliding it according to the arrow direction.
Insert new batteries, making sure that the (+) and (–) of battery are installed correctly.
Reattach the cover by sliding it back into position.
NOTES:
Use 2 AAA (1.5 volt) batteries. Do not use
rechargeable batteries.
Remove the batteries from the remote control if
the system is not going to be used for a long time.
3
2
1

Air Filter

The air filter behind the front grille should be checked and cleaned at least every 30 days or more often if necessary.
Clean the filter with warm, soapy water. Rinse and let the filter dry before replacing it.
CAUTION: DO NOT operate the air
conditioner without a filter because dirt and lint will clog it and reduce performance.
To remove (on some models):
Open the inlet grille upward by pulling out the bottom of the inlet grille.
Using the tab, pull up slightly on the filter to release it and pull it down.
To remove (on some models):
Open the inlet grille downward by pulling out the upper corners of the inlet grille. Lift it up and out.
Grasp the filter at the top center and slide it out.
To remove (on some models):
To remove (on some models):
2
1
2
1
Grab the tab on the filter and pull it to the right.
Grab the tabs on the filter and pull it up and out.
8
BEFORE YOU BEGIN
Read these instructions completely and carefully.
IMPORTANT — Save these
instructions for local inspector’s use.
IMPORTANT — Observe all
governing codes and ordinances.
Note to Installer – Be sure to leave these instructions with the Consumer.
Note to Consumer – Keep these instructions for future reference.
Skill level – Installation of this appliance requires basic mechanical skills.
Completion time – Approximately 1 hour
We recommend that two people install
this product.
Proper installation is the responsibility of the installer.
Product failure due to improper installation is not covered under the Warranty.
Installation
Air Conditioner
Instructions
Some models require a 115/120-volt a.c., 60 Hz grounded outlet protected with a 15-amp time delay fuse or circuit breaker.
The 3-prong grounding plug minimizes the possibility of electric shock hazard. If the wall outlet you plan to use is only a 2-prong outlet, it is your responsibility to have it replaced with a properly grounded 3-prong wall outlet.
Some models require 230/208-volt a.c., protected with a time delay fuse or circuit breaker. These models should be installed on their own single branch circuit for best performance and to prevent overloading house or apartment wiring circuits, which could cause a possible fire hazard from overheating wires.
ELECTRICAL REQUIREMENTS
TOOLS YOU WILL NEED
9
Phillips head screwdriver
Adjustable wrench Ruler or tape measure
Pencil
Level
Scissors or knife
CAUTION:
Do not, under any circumstances, cut or remove the third (ground) prong from the power cord.
Do not change the plug on the power cord of this air conditioner.
Aluminum house wiring may present special problems—consult a qualified electrician.
Questions? Call 800.GE.CARES (800.432.2737) or Visit our Website at: www.GEAppliances.com
PARTS INCLUDED
Window Installation Instructions
10
Sill support (2)
Top mounting rail
Right
accordion
panel
Foam top
window gasket
Window
sash seal
Left
accordion
panel
Type B (8) Type C
Bolt (2)
Security bracket (1)
Top mounting rail
seal strip
Bottom inner
case gasket
Type D (1)
(on some models)
Type A
(18 or 19)
Window Installation Instructions
WINDOW REQUIREMENTS
These instructions are for a standard double-hung window. You will need to modify them for other types of windows.
The air conditioner can be installed without the accordion panels if needed to fit in a narrow window. See the window opening dimensions below.
All supporting parts must be secured to firm wood, masonry or metal.
The electrical outlet must be within reach of the power cord.
1
STORM WINDOW REQUIREMENTS
A storm window frame will not allow the air conditioner to tilt toward the outside, and will keep it from draining properly. To adjust for this, attach a piece of wood to the stool.
WOOD PIECES– WIDTH: 2 LENGTH: Long enough to fit inside the
window frame. THICKNESS: To determine the thickness,
place a piece of wood on the stool to make it 1/2higher than the top of the storm window frame.
Attach securely with nails or screws provided by the installer.
1/2″ higher than frame
Storm window frame
Wood
Stool
2
REMOVE THE FRONT GRILLE (IF ATTACHED)
Remove shipping tape, if present. On models with a slide-out air filter, remove it (see the Care and Cleaning section) and the screw behind it (if present) that holds the grille in place.
On models with a raise-up inlet grille, lift it (see the Care and Cleaning section) and remove the screw behind it (if present) that holds the grille in place.
On some models, open the inlet grille from the sides and remove it. Remove the screws from the bottom or lower right corner, if present.
3
14min.
25to 36
(With accordion panels)
20min.
(Without accordion panels)
8,000 BTU models
10,000 and 12,000 BTU models
151⁄4min.
26to 391⁄2
(With accordion panels)
22
1
4min.
(Without accordion panels)
OR
11
OR
A
Window Installation Instructions
12
REMOVE THE FRONT GRILLE (IF ATTACHED)
(cont.)
Pull the bottom grille corners out to release the lower tabs on each side.
NOTE: Do not pull the bottom edge toward you more than 3″ or you may damage the tabs of the grille.
Lift the grille up and off the top tabs.
3
B
C
REMOVE THE AIR CONDITIONER FROM THE CASE
Remove the 2 screws on each side of the case. Keep these for later use.
Slide the air conditioner from the case by gripping the base pan handle and pulling forward while bracing the case.
Remove packing cardboard and tape, if present.
4
A
B
Front of air conditioner
Front of air conditioner
PREPARE THE CASE
Remove the backing from the top mounting rail seal strip and attach it to the bottom of the top mounting rail.
Install the top mounting rail with 4 type A or 5 type A screws (as the installation requires) from the outside of the case.
Insert the frames for the accordion panels into the top and bottom mounting rails. Attach the accordion panels to the side of the case using 6 type A screws.
5
A
B
C
Top mounting rail
Bottom mounting rail
Loading...
+ 28 hidden pages