GE ASF05, ASM05, ASQ05, ASL06, ASN05 User Manual

...
Safety Instructions . . . . . . . . . .2, 3

Operating Instructions

Controls—Control Knobs . . . . .6, 7
Controls—Touch Pads . . . . . . .4, 5

Care and Cleaning

Air Filter . . . . . . . . . . . . . . . . . . . . .8
Batteries . . . . . . . . . . . . . . . . . . . . .8
Front Grille . . . . . . . . . . . . . . . . . .9
Outdoor Coils . . . . . . . . . . . . . . . .8
Installation Instructions . . .10–13
Troubleshooting Tips . . . . . . . .14
Normal Operating Sounds . . . . .14

Consumer Support

Consumer Support . . . . . . . . . . .18
Product Registration . . . . . . .15, 16
Warranty . . . . . . . . . . . . . . . . . . . .17
DB98-15878A 49-7471 11-03 JR
ASF05
ASL05
ASM05
ASN05 ASQ05 ASV05 ASL06 ASN06
Air Conditioners
Owner’s Manual and
Installation Instructions
www.GEAppliances.com
Write the model and serial numbers here:
Model # ______________________
Serial # ______________________
Find these numbers on a label on the side of the air conditioner.
IMPORTANT SAFETY INFORMATION. READ ALL INSTRUCTIONS BEFORE USING.
WARNING!
For your safety, the information in this manual must be followed to minimize the risk of fire, electric shock or personal injury.
Use this appliance only for its intended
purpose as described in this Owner’s Manual.
This air conditioner must be properly
installed in accordance with the Installation Instructions before it is used.
Never unplug your air conditioner by pulling
on the power cord. Always grip plug firmly and pull straight out from the receptacle.
Replace immediately all electric service cords
that have become frayed or otherwise damaged. Do not use a cord that shows cracks or abrasion damage along its length or at either the plug or connector end.
Turn the mode control OFF and unplug
your air conditioner before cleaning.
GE does not support any servicing of the air
conditioner. We strongly recommend that you do not attempt to service the air conditioner yourself.
For your safety…do not store or use
combustible materials, gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance.
All air conditioners contain refrigerants,
which under federal law must be removed prior to product disposal. If you are getting rid of an old product with refrigerants, check with the company handling disposal about what to do.
SAFETY PRECAUTIONS
Do not, under any circumstances, cut or remove the third (ground) prong from the power cord. For personal safety, this appliance must be properly grounded.
The power cord of this appliance is equipped with a 3-prong (grounding) plug which mates with a standard 3-prong (grounding) wall outlet to minimize the possibility of electric shock hazard from this appliance.
Have the wall outlet and circuit checked by a qualified electrician to make sure the outlet is properly grounded.
Where a 2-prong wall outlet is encountered, it is your personal responsibility and obligation to have it replaced with a properly grounded 3-prong wall outlet.
The air conditioner should always be plugged into its own individual electrical outlet which has a voltage rating that matches the rating plate.
This provides the best performance and also prevents overloading house wiring circuits which could cause a fire hazard from overheated wires.
See the Installation Instructions, Electrical Requirements section for specific electrical connection requirements.
HOW TO CONNECT ELECTRICITY
Consumer Support Troubleshooting Tips

Operating Instructions Safety InstructionsInstallation Instructions

2
3
Consumer SupportTroubleshooting TipsOperating InstructionsSafety Instructions Installation Instructions
www.GEAppliances.com
WARNING!
Because of potential safety hazards under certain conditions, we strongly recommend against the use of an extension cord.
However, if you must use an extension cord, it is absolutely necessary that it be a UL-listed, 14 gauge, 3-wire grounding type appliance extension cord having a grounding type plug and outlet and that the electrical rating of the cord be 15 amperes (minimum) and 125 volts.
CAUTION:
DO NOT use an extension cord with any of the 230/208 volt models.
USE OF EXTENSION CORDS—
115-Volt models only
Because of potential safety hazards under certain conditions, we strongly recommend against the use of an adapter plug.
However, if you must use an adapter, where local codes permit, a temporary connection may be made to a properly grounded 2-prong wall outlet by use of a UL-listed adapter available at most local hardware stores.
The larger slot in the adapter must be aligned with the larger slot in the wall outlet to provide proper polarity in the connection of the power cord.
When disconnecting the power cord from the adapter, always hold the adapter in place with one hand while pulling the power cord plug with the other hand. If this is not done, the adapter ground terminal is very likely to break with repeated use.
If the adapter ground terminal breaks, DO NOT USE the air conditioner until a proper ground has been established.
Attaching the adapter ground terminal to a wall outlet cover screw does not ground the appliance unless the cover screw is metal, and not insulated, and the wall outlet is grounded through the house wiring. You should have the circuit checked by a qualified electrician to make sure the outlet is properly grounded.
USE OF ADAPTER PLUGS—115-Volt models only
READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY.
SAVE THESE INSTRUCTIONS
4
Consumer Support Troubleshooting Tips
Operating Instructions Safety InstructionsInstallation Instructions
To ensure proper operation, aim the remote
control at the signal receiver on the air conditioner.
The remote control signal has a range of
up to 21 feet.
Make sure nothing is between the air conditioner
and the remote control that could block the signal.
Make sure batteries are fresh and installed
correctly–see the Care and Cleaning section.
About the controls on the air conditioner—models with touch pads.
Features and appearance will vary.
Air Conditioner Controls
Remote Control
ON/OFF
Turns air conditioner on and off.
Display
Shows the set temperature, time remaining on timer or fan speed (1–LOW, 2–MED or
3–HIGH).
MODE
Use to set the air conditioner to COOL or FAN mode.
Increase /Decrease Pads
Use to set temperature when in COOL mode.
FAN
Use to set the fan speed to LOW (1), MED (2) or HIGH (3).
TIMER
ON–When the air conditioner is off, it can be
set to automatically turn on in 1 to 12 hours at its previous setting. Each touch will set the time in hours.
OFF–When the air conditioner is on, it can be set to automatically turn off in 1 to 12 hours. Each touch will set the time in hours.
To cancel the timer, press the TIMER pad until the display time disappears.
ENERGY SAVER – Controls the fan.
ON – The fan and compressor cycle on and
off. This results in wider variations of room temperature and humidity. Normally used when the room is unoccupied. NOTE: The fan will continue to run for a short time after the compressor cycles off.
OFF – The fan runs all the time, while the compressor cycles on and off.
This switch must be set at OFF in order to use the fan settings (on the mode control).
Remote Control Signal Receiver
Remote Control
In the case of a power outage or interruption, the unit will automatically re-start in the settings last used after the power is restored. The TIMER feature
will reset to the original setting. You may need to set a new time if desired.
Power Outage Recovery Feature
Fan on
Cool on
Energy Saver on
Timer on
The vent control is located on the inside of the air louvers in the lower right corner.
When set at CLOSE, only the air inside the room will be circulated and conditioned. When set at
OPEN, some inside air is exhausted outside.
Consumer SupportTroubleshooting TipsOperating Instructions
Safety Instructions
Installation Instructions
www.GEAppliances.com
When the air conditioner is turned on, it will automatically start in the setting last used.
Vent Control (on some models)
To open the vent, push the lever to the right. To close it, push it to the left.
COOL Mode
Use the COOL mode with HIGH (3), MED (2) or LOW (1) fan for cooling. Use the INCREASE / DECREASE pads to set the desired temperature
between 64°F and 86°F in 1°F increments.
A thermostat is used to maintain the room temperature. The compressor will cycle on and off to keep the room at the set level of comfort. Set the thermostat at a lower number and the indoor air will become cooler. Set the thermostat at a higher number and the indoor air will become warmer.
NOTE: If the air conditioner is off and is then turned on while set to COOL, it will take approximately 3 minutes for the compressor to start and cooling to begin.
Cooling Descriptions
For Normal Cooling–Select the COOL mode and HIGH (3) or MED (2) fan with a middle set
temperature.
For Maximum Cooling–Select the COOL mode and HIGH (3) fan with a lower set temperature.
For Quieter & Nighttime Cooling–Select the COOL mode and LOW (1) fan with a middle set
temperature.
NOTE: If you switch from a COOL setting to OFF or to a fan setting, wait at least 3 minutes before switching back to a COOL setting.
Air Direction—Up and Down (on some models)
Fingertip pressure on the horizontal louvers adjusts the air direction up or down.
FAN Mode
Use the FAN at HIGH (3), MED (2) or LOW (1) to provide air circulation and filtering without cooling. Since fan only settings do not provide cooling, a temperature setting will not be displayed.
OR
Air Direction—Side-to-Side (on some models)
On some models, the side-to-side air direction is adjusted by the louver levers or by grasping and moving the inner vertical louvers.
OR
5
Consumer Support Troubleshooting Tips
Operating Instructions Safety InstructionsInstallation Instructions
6
About the controls on the air conditioner—models with control knobs.
Features and appearance will vary.
Controls
Mode Controls
HIGH COOL, MED COOL and LOW COOL provide
cooling with different fan speeds.
LOW FAN or HIGH FAN provides air circulation and filtering without cooling.
NOTE: If you move the switch from a cool setting to OFF or to a fan setting, wait at least 3 minutes before switching back to a cool setting.
Cooling Descriptions
For Normal Cooling–Select HIGH COOL or MED COOL with the temp control at midpoint.
For Maximum Cooling–Select HIGH COOL with the
temp control at the highest number available on your knob.
For Quieter & Nighttime Cooling–Select LOW COOL with the temp control at midpoint.
Temp Controls
The temp control is used to maintain the room temperature. The compressor will cycle on and off to keep the room at the same level of comfort. When you turn the knob to a higher number, the indoor air will become cooler. Turn the knob to a lower number and the indoor air will become warmer.
MODE CONTROLS
Your model will have one of the above type controls.
TEMP CONTROLS
Your model will have one of the above type controls.
OFF
LOW
FAN
LOW
COOL
HIGH
FAN
HIGH COOL
MED COOL
OFF
LOW
FAN
LOW COOL
HI
FAN
HI
COOL
LOW
FAN
LOW
COOL
OFF
MED
COOL
4
3
2
1
HI
FAN
HI
COOL
5
6
10
COOLEST
7
8
9
45
3
2
1
6
7
8
COOLEST
34
2
1
6
COOLEST
5
The vent control is located on the inside of the air louvers in the lower right corner.
When set at CLOSE, only the air inside the room will be circulated and conditioned. When set at
OPEN, some inside air is exhausted outside.
Air Direction—Up and Down (on some models)
Fingertip pressure on the horizontal louvers adjusts the air direction up or down.
OR
Consumer SupportTroubleshooting TipsOperating Instructions
Safety Instructions
Installation Instructions
7
www.GEAppliances.com
Additional controls and important information.
Vent Control (on some models)
To open the vent, push the lever to the right. To close it, push it to the left.
Air Direction—Side-to-Side
On some models, the side-to-side air direction is adjusted by the louver levers or by grasping and moving the inner vertical louvers.
OR

Air Filter

The air filter behind the front grille should be checked and cleaned at least every 30 days or more often if necessary.
Clean the filter with warm, soapy water. Rinse and let the filter dry before replacing it.
CAUTION: DO NOT operate the air
conditioner without a filter because dirt and lint will clog it and reduce performance.
To remove (on some models):
Open the inlet grille upward by pulling out the bottom of the inlet grille.
Using the tab, pull up slightly on the filter to release it and pull it down.
To remove (on some models):
Open the inlet grille downward by pulling out the upper corners of the inlet grille. Lift it up and off.
Grasp the filter at the top center and slide it out.
To remove (on some models):
To remove (on some models):
2
1
2
1

Outdoor Coils

The coils on the outdoor side of the air conditioner should be checked regularly. If they are clogged with dirt or soot, they may be professionally steam cleaned, a service available through your GE service outlet.

Grille and Case

Turn the air conditioner off and remove the plug from the wall outlet before cleaning.
To clean, use water and a mild detergent. Do not use bleach or abrasives.
Care and cleaning of the air conditioner.
8
Consumer Support Troubleshooting Tips
Operating Instructions Safety InstructionsInstallation Instructions
Grab the tab on the filter and pull it to the right.
Grab the tabs on the filter and pull it up and out.
How to Insert the Batteries
Remove the battery cover by sliding it according to the arrow direction.
Insert new batteries making sure that the (+) and (–) of battery are installed correctly.
Reattach the cover by sliding it back into position.
NOTES:
Use 2 “AAA” (1.5 volt) batteries. Do not use
rechargeable batteries.
Remove the batteries from the remote control if
the system is not going to be used for a long time.
3
2
1
Consumer SupportTroubleshooting TipsOperating Instructions
Safety Instructions
Installation Instructions
9
Front Grille and Case
Turn the air conditioner off and remove the plug from the wall outlet before cleaning.
To clean, use water and a mild detergent. Do not use bleach or abrasives.
To remove the front grille:
On some models, remove the knobs and the screw behind the left knob.
On some models, remove the knobs, filter and screw behind the filter bottom.
Gently but firmly grasp the lower grille corners and pull forward to release.
Lift the top of the grille up and off to release from the tabs.
To replace the grille:
Hook the front of the grille onto the tabs on the top of the case.
Snap the bottom sides of the grille into the case slots.
Replace the screw and attach the knobs.
C
B
A
C
B
A
www.GEAppliances.com
On some models, remove the bottom right grille screw.
On some models, open the inlet grille from the sides and remove it. Remove the screw from the lower right corner if present.
BEFORE YOU BEGIN
Read these instructions completely and carefully.
IMPORTANT — Save these
instructions for local inspector’s use.
IMPORTANT — Observe all
governing codes and ordinances.
Note to Installer – Be sure to leave these instructions with the Consumer.
Note to Consumer – Keep these instructions for future reference.
Skill level – Installation of this appliance requires basic mechanical skills.
Completion time – Approximately 1 hour
We recommend that two people install
this product.
Proper installation is the responsibility of the installer.
Product failure due to improper installation is not covered under the Warranty.
Questions? Call 800.GE.CARES (800.432.2737) or Visit our Website at: www.GEAppliances.com
Installation
Air Conditioner
Instructions
Some models require a 115/120-volt a.c., 60 Hz grounded outlet protected with a 15-amp time delay fuse or circuit breaker.
The 3-prong grounding plug minimizes the possibility of electric shock hazard. If the wall outlet you plan to use is only a 2-prong outlet, it is your responsibility to have it replaced with a properly grounded 3-prong wall outlet.
Some models require 230/208-volt a.c., protected with a time delay fuse or circuit breaker. These models should be installed on their own single branch circuit for best performance and to prevent overloading house or apartment wiring circuits, which could cause a possible fire hazard from overheating wires.
ELECTRICAL REQUIREMENTS
TOOLS YOU WILL NEED
10
Phillips head screwdriver
Adjustable wrench Ruler or tape measure
Pencil
Level
Scissors or knife
CAUTION:
Do not, under any circumstances, cut or remove the third (ground) prong from the power cord.
Do not change the plug on the power cord of this air conditioner.
Aluminum house wiring may present special problems—consult a qualified electrician.
11
Installation Instructions
PARTS INCLUDED
Type A (9)
Security bracket (3)
Type B (8)
Top mounting rail
Right
accordion
panel
Foam top
window gasket
Window
sash seal
Left
accordion
panel
Air
conditioner
Top mounting rail
seal strip
Loading...
+ 25 hidden pages