GE APM05, APM04 Use and Care Manual

Page 1
Iu
Conten@
se and Care&Installation Guide
Air Conditioner
Adapter Plug Air Direction
Air Filter
Apphance
Care and Cleaning Condenser Coils
Consumer Services Control Settings
Electrical Requirements
Ener~-Saving Tips
Extension Cords Grille and Cabinet
Grounding Installation Instructions
Registration
Portable Models
APM04 APM05
11
7-;
Model and Serial Numbers
:
5 2
5
5
4 3
6
3
5
Safe~
Instructions
User Maintenance Instructions 5
Warran~
GE Answer Center
Back Cover
a
;
10
2
800.626.2000
GE Appliances
Page 2
Help us
hpo*t
Stiety
help you...
Before using your
air conditioner, read this book carefully.
It is
intended to help you operate
and maintain
conditioner properly. Keep it handy for answers to your
questions.
If you don’t understand something or need more help, write (include your phone number):
Consumer Affairs GE Appliances Appliance Park Louisville, KY 40225
Write down the model and serial numbers.
You’ll find them on a label on the frame of the air conditioner behind the air filter.
These numbers are also on the Consumer Product Ownership Registration Card that came with your air conditioner. Before sending in this card, please write these numbers here:
Model Number
Serial Number
Use these numbers in any correspondence or service calls concerning your air conditioner.
If you received a damaged air conditioner...
Immediately contact the dealer (or builder) that sold you the air conditioner.
your new air
Wtmctions
Read all instructions before using this appliance.
When using this appliance, always exercise basic safety precautions, including the following:
Use this appliance only for
its intended purpose as described in this Use and Care Book.
This air conditioner must be
properly installed in accordance with the Installation Instructions before it is used. See grounding
instructions on page 3.
c
Never unplug your air conditioner by pulling on the power cord. Always grip plug
firmly and pull straight out from the receptacle.
Repair or replace
immediately all electric service cords that have become frayed or otherwise damaged. Do not use a cord
that shows cracks or abrasion
damage along its length or at
plug
either the
Unplug your air conditioner
before making any repairs.
Note: We strongly recommend that any servicing be performed by a qualified individual.
For your safety. . . do not
store or use combustible materials, gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance.
or connector end,
tiYou
To obtain service, see the Consumer Services page in the back of this book.
We’re proud of our service and want you to be pleased. If for some reason you are not happy with the service you receive, here are three steps to follow for further help.
FIRST, contact the people who serviced your appliance. Explain why you are not pleased. In most cases, this will solve the problem,
NEXT, if you are still not pleased, write phone number—to:
Manager, Consumer Relations GE Appliances Appliance Park Louisville, KY 40225
FINALLY, if your problem is still not resolved, write:
Major Appliance Consumer 20 North
Chicago, IL 60606
Need
dl tie
details—including your
Action Panel
Wacker
Sertice
Drive
Save time and money. Before you request
service...
Check the Problem Solver. It lists causes of the minor operating problems that you can correct yourself.
2
SAVE THESE INSTRUCTIONS
Page 3
Electrical
Safety—WORTANT...PleaSe
Read
I
Careftily.
For personal safety, this appliance must be properly grounded.
The
Dower
cord of this
,
equipped with a three-prong (grounding) plug which mates with a standard three-prong (grounding) wall outlet (Fig. 1 ) to minimize the possibility of electric shock hazard from this appliance.
Have the wall outlet and circuit checked by a qualified electrician to make sure the outlet is properly grounded.
Where a standard two-prong wall
outIet
is encountered, it is your personal responsibility and obligation to have it replaced with a properly grounded three-prong wall outlet.
DO NOT, UNDER ANY CIRCUMSTANCES, CUT OR REMOVE THE THIRD (GROUND) PRONG FROM THE POWER CORD.
a~~liance
.,. ,. --
is
Use of adapter plug
(115-volt units)
Because of potential safety
hmards
strongly recommend against use of
an
elect to use an adapter, where codes permit, a TEMPORARY CONNECTION may be made to a properly grounded two-prong outlet by use of a UL listed adapter (Fig. 2) available at most hardware stores.
The larger slot in the adapter must be aligned with the larger slot in the wall outlet to provide proper polarity in the connection of the power cord.
CAUTION:
ground terminal to wall outlet cover screw does not ground appliance unless cover screw is metal, and not insulated, and wall outlet is grounded through house wiring. You should have circuit checked by a qualified electrician to make sure the outlet is properly grounded.
When disconnecting the power cord from the adapter,
hold the adapter with one hand. If this is not done, the adapter ground terminal is very likely to break with repeated use.
under certain conditions, we hazards under certain conditions, we
adapter plug. However, if you still
local
wdl
Iocd
PR
ER
u
Fig. 2
Attaching an adapter
FIRM CONNECTION
BEFORE USE
always
Use of extension cords not recommended
Because of potential safety strongly recommend against the use
of an extension cord. However, if you still elect to use an extension cord, it is absolutely necessary that it be a UL listed 3-wire grounding type appliance extension cord having a grounding type plug and outlet and that the electrical rating of the cord be 15 amperes (minimum) and volts.
120
Should the adapter ground
terminal break, appliance until a proper ground has again
DO NOT USE
been established.
the
3
Page 4
Operating Your Air Conditioner Controls
~*Gt/
2’/4
:;
*2
5\
41
/
@
,\
5
0
THERMOSTAT
‘6,
0
Coo[
Fe
74
\
81
,/
Thermostat Control
When you turn the Thermostat
Control to the desired setting, the
thermostat will automatically control
the temperature of the indoor air. The higher the number selected, the cooler the room air will become.
The Save Energy Range (on some models) is a visual reminder that you can save energy by turning the control to a lower number. While the room temperature will be
little
warmer, it will still be
and less humid than outside.
a
coc}ler
OFF
SELECTOR
Selector Switch
(Appearance may vary slightly) OFF turns air conditioner
Caution: If air conditioner is shut
of~
wait at least two minutes
before restarting it.
off.
HI FAN provides high fan speed
operation without cooling. LO FAN provides low fan speed
operation without cooling. HI COOL provides cooling with
high fan speed operation. LO COOL provides cooling with
low fan speed operation.
For normal cooling For
1.
1.
Set the Selector at HI COOL. temperature is not satisfactory
tifter
2. Set the Thermostat at desired number (usually the midpoint is a good starting position).
If
room
a reasonable time, set the Thermostat Control at a higher number for a cooler room or at a
lower number for
a
warmer room.
Set the Selector at HI COOL.
2. Set the Thermostat
For air circulation and filtering without cooling
Set the Selector at LO FAN or HI FAN.
For quieter operation
1.
Set the Selector at LO COOL.
2.
Set the Thermostat at desired
number.
Freezing up
Inside air hot and
humid
Outside air temperature dropping
If
you notice that your air conditioner is not cooling as it should, it
may
be
that
ice has formed
on the cooling coils. The ice blocks air
flow
cooling the room. This “freezing up” is a temporary condition that most often occurs at night when the Thermostat is set on 9 or 10 and the Selector is set on LO COOL.
To correct the condition, set the Selector at HI FAN or HI COOL with the Thermostat at
matimum
and stops the unit from
cooling
at
10.
1
or 2.
Page 5
Care and Cleating
Air direction
Air direction on the indoor side is through the front grille top. Air
be obstructed by curtains or drapes.
Upward tilted help cool the room evenly. is directed straight up.
flow
out the top should not
air
and
out the
discharge vanes
Cool
air
Moisture removal
The moisture that your air conditioner removes from the air drains to the rear where it is picked up by a dispersed against the condenser. Occasionally, more start-up, a “pinging” noise may be heard. This is time in less humid areas and longer in very humid areas. This method of moisture removal improves the operational efficiency of your air conditioner.
Note:
Before
conditioner to another location, turn
it off
and
wait 5 or 10 minutes. This will allow the condensate to drain from the coil into the base pan.
Then, keeping a firm grip on the air
conditioner, carefully raise the window and tilt the air conditioner to the outside to drain the water from the base pan.
of the cabinet
likely
during
normal for
moving your
a short
fan
and
air
USER MAINTENANCE INSTRUCTIONS
Turn air conditioner off and remove plug from wall receptacle before cleaning.
Air
Filter
The air filter behind the inlet
should be washed at least every two weeks or as often as it needs cleaning.
On the
fits into a slot at the front of the air
discharge louvers. Remove
filter by grasping its top corners
and pulling up and out.
On the fits in a slot behind an located on the front top of the air conditioner. Remove the opening the filter and pulling up and out.
APM04
APM05
model the air filter
model the air
the
access door, grasping
grille
the
filter
access door
t’ilter
by
ir Filter
reusing. It may be dried by gently shaking or pressing between towels. Replace the filter, with the filter’s front facing you.
Note: Failure to keep the air filter clean will result in poor air circulation. the air conditioner without a filter. Dirt and lint will clog the evaporator surface, reduce air flow, possibly cause ice to form and reduce cooling ability.
DO NOT operate
Grilles & Cabinet
Wipe grilles with a lightly dampened with mild liquid
dishwashing
cabinet with mild soap or detergent and lukewarm water.
detergent. Wash
clean
cl~~th
Condenser Coils
The coils on the weather side
of the unit
periodically and cleaned if clogged with dirt or soot from the atmosphere.
soiled, they may need to be steam cleaned, a service available through your General Electric service outlet.
should
be checked
If extremely
Use a vacuum cleaner to clean
filter
on its dusty side or wash gently with running water. Apply the water from the cleaner side of the filter to wash out the dust and lint. Mild detergent may be used to clean the When the air water, it must be dried before
filter
if it is very dirty.
filter
is washed in
the
5
Page 6
Ener~-sating
tips
Keep the
Don’ t let the room
air
filter
clean.
get too
hot. Whenever possible, turn the unit on
before
the room heats up.
When heat is “stored up” in walls, furniture, rugs and draperies, your
air
conditioner takes longer to produce the desired comfort condition.
Keep windows
and
doors closed. Cool, dry air escapes when they’re open.
Keep furnace
cold
air
returns closed. Cold
can easily
Don’t let drapes or furniture block the front
flow
when it is operating.
It’s best to operate your air
floor
registers
and
air
escape through them.
of the unit and restrict air
conditioner at high speed during extremely hot weather.
Keep outdoor condenser
coil
clean.
Turn air conditioner
off before
vacations or extended absences from home.
6
Page 7
~LATlON
INSTRUCTIONS
BEFORE YOU BEGIN
Read these instructions completely and carefully.
lMPORTANT–Observe
ordinances.
lNSTALLER—Be sure to leave these instructions
with the Consumer. CO
NSUMER–l<eep
reference.
all governing codes and
these instructions for future
ELECTRICAL REQUIREMENTS
FOR PERSONAL SAFETY:
This appliance must be properly grounded
See page 3.
DO
not, under any circumstances, cut or
remove the third grounding prong from the power cord.
we
recommend
extension cord or an adapter plug with this appliance.
DO
not change the
this appliance.
FOIIOW
codes and ordinances.
This appliance must be supplied with 115V,
60Hz
branch circuit, protected by a 15 or 20 amp
circuit breaker or time-delay fuse.
If
above specifications, call a licensed electrician.
Aluminum
problems–consult a qualified electrician.
national electrical codes or local
and connected to a properly grounded
the electric supply provided does not meet the
that
you
do not use an
plug
on the power cord of
house wiring may pose special
WINDOW REQUIREMENTS
Standard double-hung window with actual
opening width of
Clear
vertical opening of
bottom of sash to stool.
Install the air conditioner in a window where
there will be enough clearance around the cabinet
to allow ample circulation of air through the unit.
4
22
‘~”
to 36!
14~z”
minimum from
1
t
p’
22 ‘/2” to 36”
m
Sash
>
14’/2”
min.
Note: All supporting parts should be
secured to firm wood, masonry or metal.
INSTALLATION OF LOCATOR
Raise the window sash and remove the handle. Measure the window sill, side-to-side, and mark a center line. Secure the locator on the center of
the window sill with the edge against the stool,
using two 1” long screws.
Center Line
stool
SAVE THE CARTON
For convenient storage of air conditioner during winter months or when not in use.
TOOLS NEEDED
Phillips screwdriver Flat Blade screwdriver
I{nife
Ruler
or Scissors
Exterior
Wall
(continued next page)
7
Page 8
INSTALLATION INSTRUCTIONS
(cont,nue,,
S~RM
To overcome storm window interference, securely
attach 2“ wide wood strips to the window stool and sill (both places), with either nails or screws. Strips should be as long as and flush with back side of the window stool.
Thickness of strips should be determined by
amount of interference.
WINDOWINTERFERENCE
wrndow
Air
Wood
Filler
Strips
L
opening width
Aluminum
Storm
Window
2. Lower the window sash tight against the
sliding panels and the rear of the grille.
J
Grille
3. Extend sliding panels out from sides of air conditioner against window frame. Fasten each to sash and window stool with screws.
.
Window
Frame
I
J II
II
Sliding Panel
~~
P
.1
lNS~LLATION/N
1.
Center the unit in the window opening.
Keeping a firm grip on the air conditioner,
carefully put the bottom rail between the window
stool and the locator. If the locator is too short to hold the unit in position, insert a filler strip to raise it.
Bottom
Rail
WINDOW
tor
Strip
ed)
I
I
I
I
8
Page 9
lNS~LLATIONOFGASKET
Cut the foam width and ‘stuff” between the top of the lower sash and glass panes of the upper sash for a seal.
sashgap
gasket to the window
\
Sash Gasket ,
REMOML FROM WINDOW
1.
Turn the air conditioner off and
disconnect power cord.
2. Remove foam sash-gap gasket from between windows.
3. Remove screws securing the sliding panels to the lower sash and window stool. Close sliding panels.
4. Keeping a firm grip on the air conditioner, raise sash and carefully “rock” air conditioner
backward to drain the major portion of any condensate water in the base of the unit. Carefully lift the unit from the window to avoid spilling
any remaining water. Store parts for the air conditioner.
re-use with
9
Page 10
~
Questions?
~
Use Ttis
PROBLEM
AIR CONDITIONER DOES NOT OPERATE
AIR CONDITIONER
“DOES NOT COOL AS IT SHOULD”
OPERATING SOUNDS
Problem Solver
POSSIBLE CAUSE
Not plugged in. Plug may have been bumped loose by vacuum cleaner
or furniture.
If plugged in, fuse could have blown or circuit breaker may have tripped.
Curtain, blinds or furniture blocking the front of the air conditioner will restrict air flow.
Thermostat Control may not be set high enough. Turn knob to a higher number.
Highest setting should provide maximum cooling.
Air filter dirty, should be cleaned at least every 2 weeks.
Room may have been very hot when air conditioner was first turned on.
Allow time for it to cool down.
Cold
air may be escaping through open furnace
floor
registers and cold air returns.
Cooling coils have iced up. To melt ice, set the Selector Switch to HI FAN
or HI COOL with the Thermostat Control to 1 or 2.
Thermostat click, a metallic sound, may be heard when compressor cycles
on and off. This is normal.
Fan runs continuously when Selector Switch is in COOL or FAN position.
This is normal.
WATER DRIPPING OUTSIDE
WATER DRIPPING
Excess water may overflow in excessively hot and humid weather.
This is normal.
Air conditioner must be installed level for proper water disposal.
INSIDE WATER IN BASE PAN
(ON OUTDOOR SIDE)
This is normal for a short period in areas with little humidity; normal
for a longer period in very humid areas. Moisture removed from indoor air drains to rear of cabinet where it is picked up by a fan and thrown
If you need more help. ..call, toll free: GE Answer Center(”
)
800.626.2000 consumer information service
against
the outdoor condenser
coil.
10
Page 11
Wdll
Be There
With the purchase of your new GE appliance, receive the assurance that if you ever need information or assistance
from GE, we’ll be there.
Ml
you have to do is cdl—toll-free!
In-Home
Repak
Service
888-GE-CARES
A
GE
Consumer Service professional
will provide expert repair service,
scheduled at a time that’s convenient for you. Many GE Consumer Service company-operated locations offer you service today or tomorrow, or at your convenience weekdays, days). Our factory-trained technicians know your appliance inside and so most repairs can be one visit.
(7:00
9:00
a.m. to
a.m. to
7:00
2:00
p.m. Satur-
handed
p.m.
out—
in just
Service Contracts
8M-626-2224
You can have
GE
Consumer Service will still be there after your warranty expires. Pur­chase a GE contract while your war­ranty is still in effect and you’ll receive a substantial discount. year contract, you’re assured of future service at today’s prices.
tie
secure feeling that
Witi,
a
multiple-
GEAnswer
Center
a
Whatever your question about any major appliance, GE Answer
Cente@
information service is available to help. Your cdl—and your
will be answered promptiy and courteously And you can time. GE Answer
open 24 hours a day, 7 days a week.
1
Telecommunication Device
CenteF
question-
cdl
service is
for
the Deaf
‘“
‘I I “
.
.
any
,.
~
GE
I
Patis andAccessories
800-626-2002
Individu&
own appliances can have needed
parts or accessories sent
their home, free of shipping charge!
The GE parts system provides access
to over 47,000 parts.. and dl GE Genuine Renewal Parts are fully warranted. Discover cards are accepted.
User maintenance instructions
contained in this boo~et cover
dures
any user. Other servicing
shodd be referred to
vice personnel. Caution must be exercised, since improper servicing
may cause unsafe operation.
qutiled
WSA,
intended to be performed by
to service their
direcdy
to
MasterCard and
proce-
genedy
qutiled
ser-
For Customers With Special Needs...
800.626.2000
Upon request, GE will provide Braille controls for a variety of and a brochure to assist in planning
barrier.free
limited mobility free of charge,
Consumers with impaired hearing
or speech who have access to a
or a conventional teletypewriter may
cdl
80() -TDD-GEAC (800-833-4322)
t.o
request information or service.
kitchen for persons with
cdl
C,E
appliances
lb
obtain these
800.626.2000.
a
item!
TDD
Page 12
YOUR GE ROOM
AIR CONDITIONER
WARRANTY
Save proof of original purchase date such as your sales slip or
cancelled
check to establish warranty period.
WHAT IS COVERED
WHAT IS NOT COVERED
Service trips to your home to
teach you how to use the product.
Read your Use and Care material.
If you then have any questions about operating the product, please contact your dealer or our Consumer Affairs office at the address below, or call, toll free:
GE Answer Center(’
800.626.2000 consumer information service
)
LIMITED FIVE-YEAR WARRANTY For
five years from date of original purchase, we will provide, free of charge, parts and service labor to
any
repair or replace
room air conditioner
because of a manufacturing defect.
part of the
that fails
LIMITED TEN-YEAR WARRANTY
For ten years from date of original purchase, we will provide, free of
charge, parts and service labor to
repair or replace
the molded
outdoor case if it fails because of
a manufacturing defect.
For each of the above warranties:
To avoid any charges you must take the room air conditioner to a
General Electric Factory Service Center or a General Electric
Care(’)
Customer
servicer and pick
it up following service. In-home
service is also available, but you
must pay for the sewice technician’s
travel costs to your home.
Improper installation.
If you have an installation problem, or if the air conditioner is of improper cooling capacity for
the intended use, contact your dealer or installer. You are
responsible for providing adequate
electrical connecting facilities.
Replacement of fuses or
resetting of circuit breakers.
This warranty is extended to the original purchaser and any succeeding owner for products purchased for use in the 48 mainland states, Alaska, Hawaii and Washington,
D.C.
All warranty service will be
provided by our Factory Service
Centers or by our authorized
Customer
Care” servicers during
normal working hours. Look in the White or Yellow Pages
of your telephone directory for
GENERAL ELECTRIC COMPANY, GENERAL ELECTRIC FACTORY
SERVICE, GENERAL
ELECTRIC-
HOTPOINT FACTORY SERVICE or
GENERAL ELECTRIC CUSTOMER
@)
CARE
Failure of the product resulting
SERVICE.
from modifications to the product or due to unreasonable use including failure to provide reasonable and
necessa~
Damage to product caused
maintenance.
by improper power supply voltage, accident, fire, floods or acts of God.
WARRANTOR IS NOT RESPONSIBLE FOR CONSEQUENTIAL DAMAGES.
Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion
may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
To know what your legal rights are in your state, consult your local or state consumer affairs office or your state’s Attorney General.
Manager—Consumer Affairs, GE Appliances, Louisville, KY 40225
Th;s
book is printed on recycled paper
,
=
7-91 CG
If further
Warrantor: General Electric Company
help is needed concerning this warranty, write:
APM04
-