49-7739 -2 12-15 GE
IMPORTANT SAFETY INFORMATION.
READ ALL INSTRUCTIONS BEFORE USING.
SAFETY INFORMATION
This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others. All safety
messages will follow the safety alert symbol and the word “DANGER”, “WARNING”, or “CAUTION”. These words are defined as:
DANGER
Indicates a hazardous situation which, if not avoided, will result in death or serious injury.
WARNING
Indicates a hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION
Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
WARNING
For your safety, the information in this manual must be followed to minimize the risk of fire, electric shock or
personal injury.
SAFETY PRECAUTIONS
When using this dehumidifier, always follow basic safety precautions, including the following:
Ŷ Use this appliance only for its intended purpose as
described in this Owner’s Manual.
Ŷ This dehumidifier must be properly installed and
grounded as described in this manual before it is used.
Ŷ Never operate this dehumidifier in an area that is likely
to accumulate standing water.
If this condition develops, for your safety disconnect the
power supply before stepping into the water.
Ŷ Never unplug your dehumidifier by pulling on the power
cord. Always grip plug firmly and pull straight out from
the receptacle.
ŶReplace immediately all electric service cords that have
become frayed or otherwise damaged. A damaged power
supply cord must be replaced with a new power supply
cord obtained from the manufacturer and not repaired.
Do not use a cord that shows cracks or abrasion damage
along its length or at either the plug or connector end.
Ŷ If the receptacle does not match the plug, the receptacle
must be changed out by a qualified electrician
Ŷ For your safety, do not store or use combustible materials,
gasoline or other flammable vapors or liquids in the
vicinity of this or any other appliance.
Ŷ All dehumidifiers contain refrigerants, which under federal
law must be removed prior to product disposal. If you are
getting rid of an old product with refrigerants, check with
the company handling disposal about what to do.
Ŷ Do not use outdoors.
Ŷ This dehumidifier is intended for indoor residential
applications only. This dehumidifier should not be used
for commercial or industrial applications.
Ŷ These R410A Dehumidifier Systems require contractors
and technicians to use tools, equipment and safety
standards approved for use with this refrigerant. DO NOT
use equipment certified for R22 refrigerant only.
Ŷ Turn the dehumidifier OFF and unplug it before cleaning.
Ŷ GE does not support any servicing of the dehumidifier.
We strongly recommend that you do not attempt to
service the dehumidifier yourself.
2
WARNING
HOW TO CONNECT ELECTRICITY
Do not, under any circumstances, cut or remove the third
(ground) prong from the power cord. For personal safety, this
appliance must be properly grounded.
DO NOT use an adapter plug with this appliance.
The power cord of this appliance is equipped with a 3-prong
(grounding) plug which mates with a standard 3-prong
(grounding) wall outlet to minimize the possibility of electric
shock hazard from this appliance.
Have the wall outlet and circuit checked by a qualified
electrician to make sure the outlet is properly grounded.
Where a 2-prong wall outlet is encountered, it is your
personal responsibility and obligation to have it replaced with
a properly grounded 3-prong wall outlet.
USE OF EXTENSION CORDS
RISK OF FIRE. Could cause serious injury or death.
• DO NOT use an extension cord with this Dehumidifier.
• DO NOT use surge protectors or multi-outlet adaptors with
this Dehumidifier.
The dehumidifier should always be plugged into its own
individual electrical outlet, which has a voltage rating
matching the rating plate. This provides the best performance
and also prevents overloading house wiring circuits, which
could cause a fire hazard from overheated wires.
READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY.
SAVE THESE INSTRUCTIONS
3
About the controls on the dehumidifier.
High and Low
fan indicator
lights
Internal
Pump On
Pump
On/Off
Hold 3 Sec
Requires Hose
Controls
NOTE: When the bucket is full or removed, the controls cannot be
set.
Power Pad
Press to turn the dehumidifier on and off.
Filter Reset/Timer
After 250 hours of operation, the Clean the Filter indicator
light will glow to remind you to clean the filter. Refer to the
Care and Cleaning section of this manual for instructions on
how to clean the filter.
After cleaning the filter press the filter reset to turn off the
Clean the Filter light.
Humidity Set Control Pads
The humidity level can be set within a range of 35%
RH (Relative Humidity) to 80% RH (Relative Humidity) in
5% increments or at CO for continuous operation. To set
the unit for continuous operation, press the - pad until the
screen reads CO.
NOTE: If CO (Continuous) is selected, the dehumidifier will
operate continuously at its maximum dehumidification
settings if attached to a hose to drain or until the bucket is
full.
For drier air, press the - pad and set to a lower percent
value (%).
For damper air, press the + pad and set to a higher percent
value (%).
Clean the Filter
indicator light
Continuous operation
on indicator light
Filter
Reset
Bucket Full light indicates
bucket needs to be emptied
or is not in place in the unit
Power On
indicator light
When you first use the dehumidifier, set the humidity control
to 45% or 50%. Allow at least 24 hours for the dehumidifier
to achieve the humidity level. If you still have damper air
than desired, set the humidity level to a lower setting or
select Continuous for maximum dehumidification.
Display
Shows the set % humidity level while setting, then shows
the actual (+/– 5% accuracy) room % humidity level.
Fan Speed Pad
Controls the fan speed.
Press to select either High or Low fan speed.
Set the fan control to High for maximum moisture
removal. When the humidity has been reduced and quiet
operation is preferred, set the fan control to Low.
Pump On/Off
Activates the internal pump function.
Press for 3 seconds to active the internal pump for
automatic removal of condensate. The Internal Pump On
indicator light will flash then remain illuminated once the
3 seconds are complete.
Press to deactivate the pump.
NOTE: The internal pump will only operate when the pump
indicator light is ON AND the bucket is full of water. The pump
will not empty the bucket completely.
Other Features
BUCKET FULL Light
Glows when the bucket is ready to be emptied, or when the bucket
is removed or not replaced in the proper position.
Alarm
If the bucket is full or missing for more than 3 minutes, an alarm will
sound for about 10 seconds to remind you to empty and replace the
bucket.
4
Auto Shut Off
The Water Level Control Switch shuts off the dehumidifier when the
bucket is full, or when the bucket is removed or not replaced in the
proper position. NOTE: Fan will continue to run approximately 3
minutes after bucket is removed.
Auto Defrost
When frost builds up on the evaporator coils, the compressor will
cycle off and the fan will continue to run until the frost disappears.
Power Outage
In the case of a power outage or interruption, the unit will
automatically restart, in the settings last used, after the power is
restored.
Using the dehumidifier. GEAppliances.com
When first using the dehumidifier, operate the unit continuously for 24 hours.
How the Dehumidifier Operates
Moist, humid air is drawn over a cold refrigerated dehumidifying
coil. Moisture in the air condenses on this coil and drains into a
bucket (or through
a hose and drain).
Dry, clean air is drawn through the condenser where it is heated
and discharged out the top grille into the room.
It is normal for the surrounding air to become slightly warmer as the
dehumidifier operates.
Choosing a Location
A dehumidifier operating in a basement will have little or no effect in
drying an adjacent enclosed storage area, such as a closet, unless
there is adequate circulation of air in and out of the area.
Ŷ Do not use outdoors.
Ŷ This dehumidifier is intended for indoor residential applications
only. This dehumidifier should not be used for commercial or
industrial applications.
Ŷ Place the dehumidifier on a smooth, level floor strong enough to
support the unit with a full bucket of water.
Ŷ Allow at least 12–18 inches of air space on all sides of the unit for
good air circulation.
Ŷ Place the dehumidifier in an area where the temperature will not
fall below 41°F (5°C). The coils can become covered with frost at
temperatures below 41°F, which may reduce performance.
Ŷ Use the dehumidifier in cooking, laundry, bathing and dishwashing
areas that have excessive moisture. NOTE: Place the dehumidifier
away from the clothes dryer.
Ŷ Use the dehumidifier to prevent moisture damage anywhere
books or valuables are stored.
Ŷ Use the dehumidifier in a basement to help prevent moisture
damage.
Ŷ The dehumidifier must be operated in an enclosed area to be most
effective.
Ŷ Close all doors, windows and other outside openings to the room.
Automatic Defrost
When frost builds up on the evaporator coils, the compressor will
cycle off and the fan will continue to run until the frost disappears.
When the coil is defrosted, the compressor or fan will automatically
restart and dehumidifying will resume.
YES NO
12s–18s min.12s–18s min.
NOTE: The dehumidifier has rollers to aid placement, but it should
only be rolled on smooth, flat surfaces. Do not attempt to roll the
dehumidifier on carpet or over objects.
5
Using the dehumidifier.
Always make sure the water bucket is locked into place on the dehumidifier.
Removing Collected Water
There are 2 ways to remove collected water:
1
Use the bucket. When the bucket is removed, the unit
will shut off. Empty and replace the bucket.
NOTE: Support bucket with
both hands when emptying.
IMPORTANT: Do not use the hose if using the bucket
to collect water. When the hose is connected, water
will flow through it onto the floor instead of into the
bucket.
NOTES:Ŷ Do not remove the bucket while the dehumidifier
is operating or if it has just stopped operating. This
might cause some water to drip from the drain
pan.
Ŷ The bucket must be in place and securely seated
for the dehumidifier to operate.
Use a hose. Water can be automatically emptied into
2
a floor drain by attaching a garden water hose (not
included).
1. Remove the bucket from the front of the unit.
2. Open the drain cover on the side of the unit.
3. Thread a garden hose (not supplied) onto the
nozzle, cut to length, and lead it to the floor drain.
4. Replace the bucket in the unit.
NOTE: The bucket must be in place and securely
seated for the dehumidifier to operate.
Use the internal pump. Water can be automatically
3
emptied into a remote location by attaching the
included pump hose.
1. Attach the pump hose to the hose connector by
pushing the tube fitting into the connector until it
fits into place (should not be able to remove the
hose when pulled).
2. Position the hose discharge to the desired location.
3. Make sure the pump is activated. To activate the
pump, press and hold the Pump On/Off button for
3 seconds. The Internal Pump On indicator light will
flash then remain illuminated once the 3 seconds
are complete.
IMPORTANT: Make sure the condensate hose is
properly connected and is not kinked, bent or cracked
as this may cause water to flow onto the floor. The
bucket must also be fully seated for the pump to work
properly. Do not operate the machine if the room
temperature is 32F or below.
NOTES:
Ŷ Maximum lift height is 16ft
Ŷ The bucket must be in place and securely seated
for the dehumidifier and pump to operate.
Make sure to install hose (included) before activating
the pump.
Install hose at connector
on backside of machine
To Install Hose: Push in hose and gently pull to make
sure it is secure.
Push hose in
To Release Hose: Hold the grey ring while puling to
remove
1. Hold grey ring in
2. Pull hose out
CORRECT
DO NOT kink or crimp hose,
DVLWFDQEORFNZDWHUÀRZ
6
Using the dehumidifier. GEAppliances.com
Water Level
The dehumidifier will turn off automatically
when the bucket is full, or when the bucket is removed or
not replaced in the proper position.
The bucket must be replaced in the proper position
for the dehumidifier to work. The light will be on
and the dehumidifier will not run if the bucket is not
in the proper position.
Bucket Operation
DO NOT remove the foam piece in the bucket assembly. If
removed the Dehumidifier will not work properly.
Bucket Mode:
The dehumidifier will turn off automatically when the
bucket is full, when the bucket is removed or when the
bucket is not pushed in and seated properly. If the bucket
is not pushed in and seated properly, the “Bucket Full” light
will be on, and the dehumidifier will not run.
Pump Mode:
The pump will automatically remove water from the
bucket once it is full. It is normal to hear the pump make
some noise during operation. The pump will turn off
and the unit will not run if the bucket is removed during
operation. If the bucket is not pushed in and seated
properly, the “Bucket Full” light will come on and the
dehumidifier will not run.
IMPORTANT: It is normal for some water to remain in
the bucket after the pump has completed its condensate
removal cycle.
Foam
7
Care and cleaning of the dehumidifier.
Turn off the dehumidifier and remove the plug from the wall outlet before cleaning.
Grille and Case
To clean the case:
Use water and a mild detergent. Do not use
bleach or abrasives.
Water Bucket
To clean:
Every few weeks, clean the bucket to prevent growth of
mold, mildew and bacteria. Partially fill the bucket with
clean water and add a little mild detergent. Swish it around
in the bucket, empty and rinse.
NOTE: Do not use a dishwasher to clean the
water bucket.
To remove:
Remove the bucket and pour out any water.
To replace:
Slide the bucket into the dehumidifier.
NOTE: The bucket must be in place and securely seated for
the dehumidifier to operate.
To clean the front grille:
Use a vacuum attachment or brush.
Air Filter
The air filter behind the front grille should
be checked and cleaned at least every 250 hours
of operation or more often if necessary.
After 250 hours of operation, the Clean the Filter indicator
light will glow to remind you to clean the filter. Remove
the filter and clean it. Replace the filter and press the Filter
Timer pad to turn off the Clean the Filter light.
To remove:
Remove the bucket. Grasp the filter edge, and pull it straight
down and out.
To clean:
Clean the filter with warm, soapy water. Rinse
and let the filter dry before replacing it.
NOTE: DO NOT rinse or put the filter in an automatic
dishwasher.
CAUTION:
DO NOT operate the dehumidifier without a
filter because dirt and lint will clog it and reduce
performance.
NOTE: Avoid using a dishwasher to clean the filter.
8
Care and cleaning of the dehumidifier.
Bucket Filter
The bucket filter is located inside the bucket near the bottom. See
Figure 1. The filter should be checked when cleaning the bucket. If
the filter has any debris on it, gently remove the filter as described
below and rinse with warm water. Replace the filter in the bucket
once it is clean.
IMPORTANT: Be careful not to tear or damage filter during removal,
cleaning or replacement. Do not use the dishwasher to clean the
filter.
TO REMOVE THE FILTER:
1. Lift the handle to make the ends of the handle align with the
holes in the clasps. Push the handle towards one of the clasps
keeping the handle aligned with the clasp slots. Push the other
clasp away from the handle allowing the handle to be separated
from the clasp. Remove the handle from the other clasp.
See Figure 2.
2. Squeeze both clasp inward to disengage clasp clips from water
tank cover. Lift the cover upwards to remove. See Figure 3.
Figure 1 - Bucket Filter Location
Tabs
Filter
Figure 2
Clasp
Clip
Handle
3. Lift the end of the filter upwards to remove the filter.
See Figure 4.
TO REPLACE THE FILTER:
4. Place large end of filter above tabs, press filter down firmly to
spread tabs. Once filter is between tabs press filter inward to
engage tabs into filter.
5. Replace water tank cover and handle.
Storage
If the unit is to be stored for an extended period of time, take the
following actions before putting away the machine.
1. Empty the bucket of all water.
2. Clean the water bucket and bucket filter per instructions.
3. Allow water bucket to dry and reinstall.
4. Remove pump hose and store with unit.
Figure 3
Figure 4
Cover
5RWDWHDQGOLIW¿OWHUXS
1. Hold grey ring in
To Release Hose: Hold the grey ring while pulling the hose to
remove.
2. Pull hose out
9
Loading...
+ 19 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.