GE APCD06, APCD08 Owner’s Manual & Installation Instructions

IMPORTANT SAFETY INFORMATION .... 3
CONTROLS ...........................4
PARTS AND FEATURES ................ 6
INSTALLATION REQUIREMENTS ........ 7
INSTALLATION INSTRUCTIONS ........ 8
AIR CONDITIONER USE ............... 12
AIR CONDITIONER CARE ............. 12
TROUBLESHOOTING ................. 13
LIMITED WARRANTY ................. 15
CONSUMER SUPPORT ................ 16
Portable Room
OWNER’S MANUAL
AND INSTALLATION
APCD06 APCD08
Write the model and serial numbers here:
Model # _________________
Serial # _________________
Find these numbers on a label on the side of the air conditioner.
AIR CONDITIONER
GE is a trademark of the General Electric Company. Manufactured under trademark license.
49-5000135 Rev. 0 10-18 GEA
THANK YOU FOR MAKING GE APPLIANCES A PART OF YOUR HOME.
Whether you grew up with GE Appliances, or this is your first, we’re happy to have you in the family.
We take pride in the craftsmanship, innovation and design that goes into every GE Appliances
product, and we think you will too. Among other things, registration of your appliance ensures that we
can deliver important product information and warranty details when you need them.
Register your GE appliance now online. Helpful websites and phone numbers are available in the
Consumer Support section of this Owner’s Manual. You may also mail in the pre-printed registration
card included in the packing material.
2 49-5000135
IMPORTANT SAFETY INFORMATION
READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE
IMPORTANT SAFETY INSTRUCTIONS
IMPORTANT SAFETY INFORMATION
WARNING
shock, injury to persons, or damage when using the air conditioner, follow basic precautions, including the following:
Read all of the instructions before using this
appliance.
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Do not operate the air conditioner if it has a
damaged cord or plug, if it is not working properly, or if it has been damaged or dropped.
The air conditioner should be serviced only by
qualified service personnel. Call an authorized service company for examination, repair, or adjustment.
To reduce the risk of fire, electrical
Disconnect power before servicing.
Disconnect power before cleaning. NOTE: Turning off power by pressing the Power
button does NOT disconnect the appliance from the power supply.
Do not install or use the air conditioner in any area where the atmosphere contains combustible gases or where the atmosphere is contaminated. Avoid any chemicals coming in contact with your air conditioner.
Do not store anything directly on top of the air conditioner.
Use two or more people to move and install air conditioner.
Never operate the air conditioner without the filters in
place.
Do not use the air conditioner near a bathtub, shower or wash basin or other wet area.
READ AND SAVE THESE INSTRUCTIONS
49-5000135 3
Controls
Features and appearance will vary. Lights next to the touch pads on the air conditioner control panel indicate the selected settings.
C
A
B
D
E
Controls
A. Timer Button
Program a time from (1-hour to 24-hours) for the air
conditioner to turn Off or On. When a Time Delay is programmed, the Timer indicator light will illuminate.
While the air conditioner is operating:
1. Press the Timer button.
2. Press the Up/Down arrow buttons to select the
USING THE AIR CONDITIONER
number of hours you want the air conditioner to continue to operate before turning Off.
NOTE: Wait approximately 5 seconds for the Turn-Off
time to be saved.
While the air conditioner is off:
1. Press the Timer button.
2. Press the Up/Down arrow buttons to select the number of hours you want the air conditioner to remain off before turning On.
NOTE: Wait approximately 5 seconds for the Turn-On
time to be saved.
To cancel the timer:
• Press the Timer button once, the hours remaining will
flash, press the timer button again and the timer will be canceled.
B. Fan Speed Button The fan speed can be adjusted from Low speed to
High speed when the air conditioner is either in Cool or Fan mode.
NOTE: The fan speed cannot be adjusted when the
unit is in DEHUM mode.
• Press the Fan Speed button to toggle among the two
speeds. The corresponding fan speed indicator will illuminate.
C. Remote Control Signal Receiving Window Aim the Remote Control at this window so the Control
will receive the signal.
D. CONTROL PANEL DISPLAY Displays the Set Temperature in degrees Fahrenheit
or degrees Celsius, or the hours remaining in a Time Delay. The corresponding indicator light will illuminate.
E. Up and Down Arrow Buttons Adjusts the Temperature or Hours in Time Delay.
High
Cool
Low
Dehum
F
G
H
TEMP
Sleep
TIMER POWER
Fan
I
C / F
To Set the Temperature: The temperature can be set between 62ºF and 86º F
(17ºC and 30º C) when the air conditioner is in Cool mode.
1. Press the Mode button until the Cool mode is selected.
2. Press the Up Arrow or Down Arrow buttons to select
the Temperature.
NOTE: The temperature cannot be set when the air
conditioner is in either Fan or Dry mode.
F. Mode Button Press the Mode button to toggle among the operating
options. The corresponding indicator will illuminate: Cool – Cools the room to the set temperature ECO – Cycles fan to cool economically Dehum – Reduces the humidity in the room Fan – Circulates the air in the room without cooling G. Power Button Turns ON/OFF power to the air conditioner. NOTE: Turning o power by pressing the Power button
does NOT disconnect the appliance from the power
supply.
• Press the Power button. The Power indicator will
illuminate.
REMOTE CONTROL
1. Insert the two batteries (provided).
2. Aim the remote control at the signal receiver on the
control panel to operate the air conditioner.
H. Sleep Button Increases the set temperature by 2ºF (1ºC) after
2-hours, and then increases the temperature by an additional 2ºF (1ºC) after another 2-hours.
NOTE: The fan will operate at Low speed and cannot
be adjusted while in Sleep mode. Press the Sleep button to enter Sleep mode. The Sleep indicator will illuminate.
To Cancel Sleep Mode:
• Press the Sleep button or the Mode button (Cool, Fan
or Dry) on the remote control.
I. ºC/ºF Button
• Press the ºC/ºF button to toggle between displaying
the temperature in degrees Fahrenheit or degrees Celsius. The corresponding indicator will illuminate.
4 49-5000135
Controls
The display will always default to show the room temperature. When the air conditioner is turned on, it will automatically start in the last mode and fan settings selected.
Cool Mode
Use the COOL mode for cooling. To set the COOL mode:
1. Press the MODE pad until the COOL indicator light is lit.
2. Press the FAN pad to set HIGH or LOW fan speed.
3. Press + or - to set the desired temperature between
61°F and 89°F in 1°F increments.
After settings have been made, the display will change back to show the room temperature.
The temperature control is used to maintain the room temperature. The compressor will cycle on and off to keep the room at the set level of comfort. Set the temperature control at a lower number and the indoor air will become cooler. Set the temperature control at a higher number and the indoor air will become warmer.
ECO Mode
Use ECO mode for economy cooling. To set ECO Mode:
1. Press the MODE pad until the ECO indicator light is lit.
2. Press FAN pad to set high or low fan speede.
3. Press + or - to set desired temperature between 61°F and 89°F in 1°F increments.
NOTE: If the air conditioner is off and is then turned on while set to COOL, it will take approximately 3 minutes for the compressor to start and cooling to begin.
Cooling Descriptions For Normal Cooling—Select the COOL mode and
HIGH or LOW fan speed with a middle set temperature. For Maximum Cooling—Select the COOL mode
and HIGH fan speed with a lower set temperature. For Quieter & Nighttime Cooling—Select the
COOL mode and LOW fan speed with a middle set temperature.
NOTE: If you switch from COOL or DEHUM mode setting to OFF, wait 3 minutes before restarting.
In ECO mode, the fan will cycle off with the compressor when room temperature is reached. Then thefan will cycle 10 minutes off / 2 minutes on to sample the room temperature.
USING THE AIR CONDITIONER
DEHUM Mode—Dehumidification
Use the DEHUM mode to provide dehumidification only. The fan will run at a fixed speed at this setting, so a fan speed cannot be set. Keep windows and doors closed for the best dehumidifying effects.
To set the DEHUM mode:
•Press the MODE pad until the DEHUM indicator light is lit. In the DEHUM mode, a set temperature will not be
displayed. After DEHUM mode has been set, the display will change back to show the room temperature.
NOTE: If you switch from a DEHUM setting to OFF or
FAN Mode
Use the FAN mode to provide air circulation and filtering without cooling.
To set the FAN mode:
• Press the FAN pad until the desired indicator light for HIGH or LOW fan speed is lit.
Power Outage Recovery Feature
In the case of a power outage or interruption, the unit will automatically re-start in the settings last used after the power is restored.
to a fan setting, wait at least 3 minutes before switching back to a DEHUM setting.
If using the unit in the DEHUM mode as a dehumidifier for an extended time.
1 . Unplug the power cord.
2. Connect a drain hose (not included) to the bottom drain port (see page 10, lower drain #8) and lead hose to floor drain.
3. Reconnect the power cord and press the MODE pad until the DEHUM indicator light is lit.
Since fan only settings do not provide cooling, a set temperature will not be displayed. After FAN speed has been set, the display will change back to show the room temperature.
NOTE: If the TIMER was set before the power outage, it will need to be reset after power is restored.
49-5000135 5
Parts and Features
5
1
2
3
4
USING THE AIR CONDITIONER
1. Control Panel
2. Vertical Louvers
3. Horizontal Louvers
4. Casters
5.
Handle (right side for remote control storage)
6. Plug Storage
10
NOTE: Remove filters (number
11) first, in order to access filters
6
11
10 and 12.
7
12
8
9
7. Power Cord Storage
8. Power Cord
9. Drain Hole and Cover
10. Filter
11. Filters
12. Filter
6 49-5000135
Installation Requirements
TOOLS AND PARTS
Gather the required tools and parts before starting installation.
TOOLS NEEDED
• Flat-blade Screwdriver
• Phillips Screwdriver
PARTS SUPPLIED
INSTALLATION REQUIREMENTS
Main Window
Panel
Pointed Screws (7)
2 for top window brackets 1 for security bracket 4 for main window panel
Top Window
Bracket (2)
Use for Vinyl
Windows
Extension
Panels (2)
Exhaust
Nozzle
Bottom
Window Bracket (2)
Use for Vinyl Windows
Flat Screws (6)
4 for extension panels 2 for nozzles
Exhaust Hose
Security
Bracket
Top Foam Seal
(10 mm x 10 mm x 102 cm
49-5000135 7
Bottom Foam Seal
(3 mm x 10 mm x 102 cm
Stuffer Seal
Strip (15 mm x 33 mm x 1200 mm)
Installation Instructions
Questions? Call GE Appliances at 800.GE.CARES (800.432.2737) or visit our Website at: GEAppliances.com.
BEFORE YOU BEGIN
Read these instructions completely and carefully.
IMPORTANT — Save these instructions for
local inspector’s use.
IMPORTANT Observe all governing codes
and ordinances.
Note to Installer – Be sure to leave these
instructions with the Consumer.
Note to Consumer – Keep these instructions for
future reference.
Skill level – Installation of this appliance requires
basic mechanical skills.
Completion time – Approximately 1 hour
• We recommend that two people install this product.
• Proper installation is the responsibility of the installer.
• Product failure due to improper installation is not
INSTALLATION INSTRUCTIONS
covered under the Warranty.
• You MUST use all supplied parts and use proper installation procedures as described in these instructions when installing this air conditioner.
ELECTRICAL REQUIREMENTS
Some models require a 115/120-volt AC, 60-Hz grounded outlet protected with a 15-amp time-delay fuse or circuit breaker.
The 3-prong grounding plug minimizes the possibility of electric shock hazard. If the wall outlet you plan to use is only a 2-prong outlet, it is your responsibility to have it replaced with a properly grounded 3-prong wall outlet.
Power cord includes a current interrupter device. A test and reset button is provided on the plug case. The device should be tested on a periodic basis by first pressing the TEST button and then the RESET button while plugged into the outlet. If the TEST button does not trip or if the RESET button will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician.
Location Requirements
• Place the air conditioner on a flat, level surface in a location that is at least 30” (76.2 cm) from any wall.
NOTE: A minimum clearance of 30” (76.2 cm) from the air conditioner to the wall must be maintained to ensure proper airflow.
• Maintain a minimum 30” (76.2 cm) clearance around
the air conditioner to not block airflow.
• Keep the air conditioner free of any obstructions
such as drapes, curtains, blinds, etc.
• The exhaust hose should be free of any
obstructions.
• Do not place the air conditioner on an unstable
or raised surface because it could fall and cause damage or injury.
Do not place the air conditioner in direct sunlight or near a heat source such as baseboard heaters, stoves, etc.
• The window panel can be installed in a window with
a minimum 30” (76.2 cm) to a maximum 40” (101.6 cm) opening.
CAUTION
Do not, under any circumstances, cut or remove the third (ground) prong from the power cord.
Do not change the plug on the power cord of this air conditioner.
Aluminium house wiring may present special problems—consult a qualified electrician.
30" (76.2 cm)
30"
8 49-5000135
Installation Instructions
INSTALLATION INSTRUCTIONS
1. Unpack the Air Conditioner
WARNING
Excessive Weight Hazard
• Use two or more people to move and install air conditioner.
• Failure to do so can result in back or other injury.
• Remove packaging materials. Save the carton and the foam packaging for storing the air conditioner when not in use.
NOTE: There are NO packing materials inside the air conditioner to remove—Do Not open the cabinet.
• Properly dispose of/recycle all packing material.
• Handle the air conditioner gently.
• Keep the air conditioner upright and level. Do not set the air conditioner on its side, front, back or upside down.
2. Install Exhaust Nozzle to Main
Window Panel
1. Hold the main window panel so that the L-shaped
edges of the panel are facing you.
L-Shaped
AA
2. Align the exhaust nozzle with the slots in the
opening, and then insert and slide the nozzle to access the hole from the back of the main window panel.
Edges
3. Install Main Window Panel and
Extension Panels
NOTE: Depending on the size of your window
opening, use the main panel and one or both of the extension panels.
1. Open the window and place the main window panel into the window.
NOTE: The window assembly is designed to accommodate either a vertical slide or horizontal slide window.
Vertical Slide Window:
Main Window Panel
A
Horizontal Slide Window:
A
Main Window Panel
A
2. Adjust the extension panel(s) to the width or height of the window as shown.
NOTE: Some window installations may require the extension panels to be trimmed.
3. Depending on the number of extension panels used, use two or four flat screws to secure the extension panel(s) to the main panel. Install from the back.
A
Main Window
A
B
Panel Exhaust
B
Nozzle (1 or 2 depending
on model)
3. Turn the main window panel over, so that the nozzle is away from you. Insert a flat screw through the hole to fasten the window panel to the adapter.
NOTE: There are many window types on the market today. Use the foam strips and brackets (provided) to secure the extension panels that will fit the window opening.
4. For vinyl windows only. Skip to step 6 for wood windows. Place the two top window brackets and two bottom window brackets where they will best support the extension panels.
Before assembly: USE ONLY FOR VINYL
NOTE: On a dual hose unit, install the smaller hose nozzle to the left-hand hole in the panel.
A
49-5000135 9
A Flat
Screw
A
B
A
B
Top Window Brackets
A
Bottom Window Brackets
B
Installation Instructions
3. Install Main Window Panel and
Extension Panels (cont.)
After assembly:
Attach with pointed screws (2)
5.
Apply the top foam strip (provided) across the
top of the window panel assembly, and then apply the bottom foam strip (provided) across the bottom front edge of the window panel assembly, as shown.
Typical Vinyl Window Installation:
A B
INSTALLATION INSTRUCTIONS
C
D
6. Place the window panel assembly in the window, and using the screws provided, fasten the assembly to the window sill and window frame.
Top Foam Strip
A
Top Bracket
B
Extension Panel
C
Bottom Bracket
D
Bottom Foam Strip
E
E
4. Attach Exhaust Hose to the
Exhaust Nozzle
1. Grasp both ends of the exhaust hose and gently pull to expand the hose.
NOTE: Do not attach additional hoses to extend the length. This would decrease cooling efficiency and may damage the air conditioner.
2. Using a counterclockwise motion, attach the open end of the exhaust hose to the exhaust nozzle.
A
B
Exhaust Nozzle
A
(1 or 2 depending on the model)
Hose (open end)
B
Hose (connector)
C
C
5. Connect Exhaust Hose to the
Air Conditioner
IMPORTANT: When connecting the hose, the air conditioner must be close enough to the window that you will not dislodge the window seal plate. Once the hose is connected, move the air conditioner 20” (51 cm) from the wall.
1. Extend the flexible exhaust hose to reach out to the unit.
2. Aim the opening of the hose to the air exhaust outlet and push it hard straight into the outlet until it clicks.
7. Using one pointed screw, install the Security bracket to the window.
NOTE: The security bracket prevents the window
from being opened from the outside.
A
A
Security Bracket Pointed Screw (1)
B
B
10 49-5000135
Loading...
+ 22 hidden pages