GEAppliances.com
Safety Instructions ............. 2, 3
Operating Instructions
Controls ...................... 4-6
Care and Cleaning
Air Filter ........................ 6
Otltdoor Coils .................... 6
Installation Instructions ....... 7-13
AKM I4 *
AKM I8 *
AKM25*
AKQ24
Troubleshooting Tips ........... 14
Normal Operating Sounds ........ 14
Consumer Support
Consumer Support ....... Back Cover
Ownership Registration for
Customers in Canada only ..... 15, 16
Warranty for Customers
in Canada ...................... 18
Warranty for Customers
in the U.S.A..................... 17
*ENERGY STAR ® labeled product
ENERGYSTAR
Climadseur
La section fran_'aise commence ?_la page 19
Acondicionador
o
de alre
La secci6n en espa,F_olempieza en la pdgina 3 7
<
As an ENERGY STAR®partner; (;E has
determined that this product meets
tile ENERGY STAR®guidelines for
energ o, eflqcienc>
Write the model andserial numbers here:
Model #
Serial #
Find these numbers on a label on tile
side of tile air conditioner
In Canada, contact us at:
www.GEAppliances.ca
49-7634 01-10JR
IMPORTANTSAFETYINFORMATION.
READALLINSTRUCTIONSBEFOREUSING
m
For your safety, the information in this manual must be followed to minimize the risk of fire, electric shock
or personal injury,
SAFETYPRECAUtiONS
}} Use this appliance only fi)r its intended }}
purpose as described in this Owner's
Manual.
iii}i}i
This air conditioner must be properly
installed in accordance with the Installation
Instructions before it is used.
iii}i}}li_
Never unplug your air conditioner by pulling
iii}i}i
on the power cord. Alwaysgrip plug firmly
and pull straight out from the receptacle.
iii}i}}li_
Replace immediately 'allelectric sen,ice
iii}i}}li_
cords that have become flayed or other_dse
damaged. A damaged power supply cord
must be replaced with a new power supply
cord obtained from the manufhcturer and
iii}i}}li_
not repaired. Do not use a cord that shows
cracks or abrasion damage along its len_h
or at either the plug or connector end.
iiiH}}ii{_
Turn the unit OFFand unplug your air
conditioner befi)re cleaning.
iii}i}}li_
GE does not support any servicing of the air
conditioner. _% strongly recommend that
you do not attempt to ser_;icethe air
conditioner yourseff,
For your safety...do not store or use
combustible materials, gasoline or other
flammable vapors or liquids in the x,icinity
of this or any other appliance.
All air conditioners contain refligerants,
which under federal law must be removed
prior to pro&lct disposal, ffyou are getting
rid of an old product _dth refrigerants,
check ;_dththe company handling disposal
about what to do.
ff the receptacle does not match the plug,
the receptacle must be changed out by a
qualified electrician.
These 1),410A air conditioning systems
require contractors and technicians to
use tools, equipment and saIety standards
approved for use with this refligerant.
DO NOT use equipment certified fbr
1_222refligerant only.
HOWTOCONNECTELECTRICITY
Do not, under any circumstances, cut or remove
the third (ground) prong from the power cord,
For personal safety, this appliance must be
properly grounded,
DONOT use an adapter plug with this appliance.
The power cord of this appliance is equipped
_dth a 3-prong (grounding) plug which mates
_dth a standard &prong (grounding) wall
oudet to minimize the possibility of electric
shock hazard from this appliance.
Power cord includes a current interrupter
dex,ice. A test and reset button is prox,ided on
the plug case. The dex;ice should be tested on a
periodic basis by first pressing the YESYbutton
and then the RESEYbutton while plugged into
the outlet. If the TESrbutmn does not trip
or it the RESETbutmn _dll not stay engaged,
discontinue use of the air conditioner and
2
contact a qualified serx,ice technician.
Have the wall outlet and circuit checked by
a qualified electrician to make sure the outlet
is properly grounded.
Where a 2-prong wall outlet is encounmred,
it is your personal responsibility and obligation
to have it replaced with a properly grounded
3-prong wall oudet.
The air conditioner should always be plugged
into its own indix,idual electrical outlet which
has a voltage rating that matches the rating
plate.
This prox,ides the best perfbrmance and also
prevents overloading house wiring circuits
which could cause a fire hazard from
overheated wires.
See the Installation Instructions, Electrical
Requirements section for specific electrical
connection requirements.
WA
USEOFEXTENSIONCORDS--775-Voltmodelsonly
GEApp/iance&com
Because of potential safety hazards under certain
conditions, we strongly recommend against the
use of an extension cord.
However, if you must use an extension cord,
it is absolutely necessary that it be a UL-listed,
14-gauge, 3-wire grounding-type appliance
exmnsion cord having a grounding-type plug
and outlet and that the electrical rating of the
cord be 15 amperes (minimum) and 125 volts.
.4,CAUTION:
DONOTuseanextensioncord withanyofthe
230/208voltmodels.
READANDFOLLOWTHISSAFETYINFORMAtiONCAREFULLY.
SAVETHESEINSTRUCTIONS
3
About the controls on the air conditioner.
Features and appearance will vary.
Lights next to the touch pads on the air conditioner control panel indicate the selected settings,
Lightindicatesthe unit
is in temperatureor
delaytime Setmode.
\
\
Lightindicatesthe
delay timer is set.
• I .... Oe
JGO£1 5._o_ _ CFoq
NOTE:Thedisplayalways shows the room
temperature except when setting the Set
temperatureor the Delaytimer.
Air ConditionerControls
Controls
Power Pad
Tmns air conditioner on and off. _;hen
turned on, the display will show the room
temperature.
DisplaF
Shows die room temperature or time
remaining on the Dela?. timer Shows the Set
mmperamre while setting the temperature in
Cool or Energy Saver modes. The Set light will
mrn on while setting.
NOTE:The display will change to show the
room temperature after settings have been
made. To recall the Set temperature, press the
YempIncrease A or Decrease V pads.
O empIncrease A/Decrease T Pads
Use [ose[ [emperamre when in COOlor Energy
Savermode. The Set Ugh[ will mrn on while
setdng.
Delay Timer Increase A /Decrease Y Pads
Each touch of the Increase A /Decrease Y
pads on the unit or on the relIlote conQol will
set the dela), time when using the Delay 1-24hr
timer The Set light will mrn on while setting.
Fan Speed Pads
Use to set the fan speed to LOw, Med, High
or Auto on the unit. NOTE:On the remora
control, use the Fan button to set the fan
speed to LOw, Med, High or Auto.
Delaytimerand2 Z .........i I VTemp2 ....
temperatureset_ _ I I(--) _)
Decrease/Increase ...........Power
_' _ I Delay_ FanFan
uelay 1-24hr !_ _ _
Modeselect _ ..........................................................] Sl_ee)p
l Mode
Remote Control
O ode Pad
Use to set d_eair condidoner to Cool, Energy
Saveror Fanmode.
Delay Pads
0
Delay ON--When the air conditioner is off; it
can be se[ to automatically come on in 1 to 24
hours at its previous mode and fan settings.
DeNy OFF--When tlle Nr conditioner is on,
k can be set to automadcNly mrn off in 1 to
24 ]louis.
How to set
Press die Delay 1-24hrpad on the unit or on
the relilOm control. Each touch of the Increase
A/Decrease T pads on the unit or on the
iemom conUol will set the timer in 1/2-hem
inmrva/s undl the time reaches 10 ]K)urs; then
it will increase in 1-hour inmrva/s. The Set
light will mrn on while setdng.
To review the remaining dine on the Delay
f-24hr dme_; press [he Delay f-24hr pad on
the unit or on the remote control Use the
Increase A/Decrease Y pads on the unit
OI" OI1 [lie IeIIlo[e COlIEIol [o se[ a Ilew [ilIle
if desired.
Tocancelthe timer, press die Delay f-24hr pad
undl the light on the Delay 1-24hrpad goes off.
Unit poweron/off
Auto Fanon/off and
Decrease/Increase
4
Do Not Operate inFreezingOutdoorConditions
This cool-only air conditioner was not designed for
fleezing outdoor conditions. It must not be used in
fleezing outdoor conditions.
Remote Control
GEAppliances.com
To ensure proper operation, aim file remote
control at the signal receiver on the air
conditioner
The remote conuol signal has a range of
up to 20 feet.
Cool Mode
Use the Coolmode at Low, Met/, High or Auto Fan
Speed for cooling. Use the Temperature Increase A /
Decrease W pads to set the desired mmperamre
between 62°F and 86°F in 1 °F increments.
An electronic dlermostat is used to maintain file
room mlnpemlalre. The compressor will cycle on
and off to keep the room at the set level of comfort.
Set the themlostat at a lower number and the indoor
air will become cooler Set the themlostat at a higher
number and the indoor air will become wam_e_:
NOTE:If theairconditioneris offandis thentumedon
whilesettoa Coolsettingorif tumedfromafansetting
toa Coolsetting,it maytakeapproximatdg3minutes
forthecompressortostartandcoolingtobegin.
Energy Saver Mode
Controls the f_m.
0N--The fire will cycle on and offwith the
compressor This results in wider variations of room
mmpemmre and humidity. Nomm/ly used when the
room is tmoccupied. NOTE: Thefan 1778}/continueto run
forashort timeafter the compressorcyclesoff
Make sure nodfing is between file air conditioner
and the remora control that coukt block the
signN.
Make sure batteries are flesh and instaUed
correc@ _ksindicated on the remote control.
Cooling Descriptions
For Normal Cooling--Select the Coolmode and
High or Med fire with a middle set temperature.
ForMaximum Cooling--Select the Cool mode
and High f_m wkh a lower set mmperamre.
ForQuieter and Nighttime Cooling--Select the
Cool mode and LOWf_m wkh a middle set
temperature.
OFF--The fire runs all file time, while the
compressor cycles on and off.
Fan Mode
Use die Fan Mode at tow, Med or High fire speed to
provide air circulation and filtering wifllout cooling.
Since fire-only settings do not provide cooling,
a Set mmperamre cannot be enmred. The room
temperature will appear in the display.
Auto Fan Speed
Set to AutO fire speed for the f_m speed to
automatically set to file speed needed to provide
optimum comfort settings with the set mmpemmre.
If the room needs more cooling, the f_m speed
will automatically increase. If the room needs less
cooling, the f_m speed will automatical b decrease.
Power Outage Recovery Feature
In file case of a power outage or interruption, file
unit will automaficall), restart in file settings last
used a[_er the power is restored. If the De/el/1-24hr
NOTE:AutoFanSpeedisavailableintheFanMode.
NOTE:AutoFanSpeedisavailableintheFanMode.
feature was set, it will resmne cotmtdown. You me}.
need to set a new dine if desired. 5
About the controls on the air conditioner.
Additional important information,
Air Direction
Use the lever to adjust the air direction left m'ld
right on/y:
FreshA# Vent Control (on somemodels)
The Fresh Air Vent Control[ allows you to let flesh
air into the room.
To open the vent, pull the mb out to allow flesh air
to circulate into the room.
To close the vent, push the mb in.
Careand cleaningof the air conditioner.
Grille and Case
Turn the air conditioner off and remove the plug
flom the wall outlet before cleaning.
To clean, use water and a mild detergent. Do not
use bleach or abrasives.
Air Filter
The air filter behind file flont grille shoukt be
checked and cleaned at least ever) 30 days or
more often if necessary.
Toremove:
Open die inlet grille by pulling do_lward on die
tabs at the top upper corners of the inlet grille until
the grille is in a 45 ° position. Remove the film_:
Clean the filter with warm, soapy wateI: Rinse and
let the filmr dr) before replacing it. Do not clean
the filter in a dishwasher:
^,.,CAUTION'._oNoroperatetheairconditioner
without afilter becausedirt and lint will clog it and reduce
performance.
Outdoor Coils
The coils on the outdoor side of the air conditioner
should be checked regularly. If they are clogged
with dirt or soot, they me). be professionN1) cleaned.
Tab Tab
How toInsert theBatteries in theRemoteControl
_] Remove the battery cover by sliding it
according to the arrow direction.
_] Insert new batteries, making sure that the (+)
and (-) of battery are installed correctly.
[_ eattach the cover by sliding it back
into position.
6
NOTES:
Use 2 "AAA" (1.5 volt) alkaUne batteries. Do not
use rechargeable batteries.
Remove the batteries flom the reIilOm con[/o][ if
the sysmm is not going to be used for a long time.
Do not mix old and new batteries. Do not mix
aU<a/ine, smndard (carbon-zinc) or rechargeable
(hi-cad, ni-mh, etc.) batteries.
I stall ti
Ai Conditio
structi
_ Questions? Call 800.GE.CARES (800.432.2737) orVisit ourWebsite at: GEAppliances.com
i m
in Canada, call 1.800.561.3344 or visit www.GEAppliances.ca i
BEFORE YOU BEGIN
Read these instructions completely
and carefully.
• IMPORTANT - Savethese
instructions for local inspector's use.
• IMPORTANT - Observe
governing codes and ordinances.
• Note to Installer- Be sure to leave these
instructions with the Consumer.
• Note to Consumer- Keep these
instructions for future reference.
• Skill level - Installation of this appliance
requires basic mechanical skills.
• Completion time- Approximately 1 hour
• We recommend that two people install
this product.
• Proper installation is the responsibility
of the installer.
Product failure due to improper installation
is not covered under the Warranty.
You MUST use all supplied parts and use
proper installation procedures as described
in these instructions when installing this air
conditioner.
-4,CAUTION:
Do not, under any circumstances, cut or
remove the third (ground) prong from the
power cord.
Do not change the plug on the power cord
of this air conditioner.
Aluminum house wiring may present special
problems--consult a qualified electrician.
TOOLS YOU WILL NEED
Phillips head screwdriver
Flat-blade screwdriver
_) ELECTRICAL REQUIREMENTS
(_ ome models require a 115/120-voltAC,
The 3-prong grounding plug minimizes the
possibility of electric shock hazard. If the wall
outlet you plan to use is only a 2-prong outlet,
it is your responsibility to have it replaced with
a properly grounded 3-prong wall outlet.
©
60-Hz grounded outlet protected with a
15-amp time-delay fuse or circuit breaker.
Some models require 230/208-volt AC,
protected with a time-delay fuse or circuit
breaker. These models should be installed
on their own single branch circuit for
best performance and to prevent
overloading house or apartment wiring
circuits, which could cause a possible
fire hazard from overheating wires.
Pencil Ruler or tape measure
Level Scissors or knife
Power cord includes a current interrupter
device. A test and reset button is provided on
the plug case. The device should be tested on a
periodic basis by first pressing the TEST button
and then the RESET button while plugged into
the outlet. If the TEST button does not trip or
if the RESET button will not stay engaged,
discontinue use of the air conditioner and
contact a qualified service technician.
7
PARTS iNCLUDED
(Appearance may vary)
Installation instructions
Right
accordion
panel
%
V-supports (2)
Type A
screws (4)
Type B
screws (8)
Window
Sill angle locking
bracket (2) bracket (3)
TypeC @ @
screws (2)
Type F bolt V-support bolt
with nut (4) and nut (2)
8
Sash
locks (2)
®
Type E bolt
with 2 nuts (2)
Installation instructions
m WINDOW REQUIREMENTS
• These instructions are for a standard double-
hung window. You will need to modify them
for other types of windows.
• All supporting parts must be secured
to firm wood, masonry or metal.
• The electrical outlet must be within reach of
the power cord.
• Follow the dimensions in the table and
illustration for your model.
Models A B
AKM14, AKM18 18 3/8" 27"-42 1/2"
AKM25, AKQ24 19 1/2" 29 3/4"-44"
[ ///
B===8
J
t
A
B
(With accordion panels)
-3
[] PREPARE THE AiR CONDiTiONER
[] Pull down the front panel and remove the
filter. Remove the front panel by lifting up
at an angle.
FB'] Remove the four front screws. Save them
for reinstalling the front housing.
....
[] Remove the front housing.
[] STORM WINDOW REQUIREMENTS
A storm window frame will not allow the air
conditioner to tilt toward the outside, and will
keep it from draining properly.
To adjust for this, attach a piece of wood to
the sill.
WOOD PIECES
WIDTH: 2"
LENGTH: Long enough to fit inside the
window frame.
THICKNESS: To determine the thickness, place
a piece of wood on the sill to make it 1/2"
higher than the top of the storm window
frame or the vinyl frame.
Attach securely with nails or screws provided
by the installer.
|
than storm
window
frame
1/2" higher ___ °°d
Storm window
frame
1/2" higher
than vinyl frame
L (on some windows)
w
Remove the screw attaching the green
grounding wire to the case and save it for
reinstalling the wire.
9
Installation instructions
[] PREPARE THE CASE
[_ Remove shipping screws located on the
top and the sides of the case.
Depending on the
model, there can be
two screws on each
side.
[] Slide the air conditioner from the case by
gripping the base pan handle and pulling
forward while bracing the case.
PREPARE THE CASE (cont.)
Attach the top rail gasket to the bottom of
the top rail.
r_ Use small pieces of adhesive foam to
cover the shipping screw holes.
[] Install the top mounting rail with 4 type A
screws from the inside of the case. Press
firmly to drive the screws into the gasket
and through the top mounting rail.
Top mounting rail
Your unit may come with internal
packaging.This packaging must be
removed prior to installing the air
conditioner back into the cabinet.
10
Installation instructions
iNSTALL THE ACCORDION PANELS
[]
Slide the free end of the accordion panel
[]
into the side panel rails. Slide the panel
down. Be sure to leave enough space to
slip the top and bottom of the frame into
the rails on the cabinet.
NOTE:There is a right and a left accordion
panel. Be sure to use the proper panel for
each side.
[] Slide the left and right accordion panels
into the top and bottom mounting rails.
iNSTALL THE CASE IN THE
[]
WINDOW
Open the window and mark the center of
the window sill.
FBq
Carefully slide the case into the window
and center the case. Lower the window
behind the top mounting rail. Pull the
bottom of the case forward so that the
bottom mounting rail is tight against the
back of the window stool. Mount the case
to the window sill using 2 type B screws
for a wood frame or 2 type C screws with
window locking brackets for other types of
windows. Drill pilot holes, if necessary.
2 B
Stool
type screws
Top mounting rail Top right
Bottom mounting rail
161PREPARETHE WINDOW
Cut the window sash seal to the proper
length. Peel off the backing and attach the
seal to the underside of the window sash.
F_ iNSTALL THE V-SUPPORTS
For Windows With an Outside Sill:
Assemble theY-support and V-support
bracket with V-support nut and bolt.
Type F bolt
Le_._ _
and nut
Sill angle Right
bracket ----_© _"
V-support
bolt and nut
Position the V-supports
on the case bottom so
that they will be near the
outside wall. Attach a V-
support to each side of the
bottom of the case with
Type F bolts, 2 for each
support.
11
Installation instructions
[_ iNSTALL THE V-SUPPORTS (cont.)
For Windows With an Outside Sill (cont.):
FC-IAdjust sill angle brackets to rest on sill.
ForWindows Without an Outside Sill:
[] Assemble the V-support andType
E bolt with two nuts.
[]
Use a wood block (obtained
locally) between theType E
bolts and the wall if the wall
is weak or if the weight of the
air conditioner falls between
the studs in the wal!.
@
Adjust theType E bolts l_
and nuts against the
outside wal! so that
the case has a slight
tilt to the outside.
Tighten nuts with an
adjustable wrench. Use
a level; no more than a
1/2 bubble will be the correct case slant to
the outside.
@
Extend the left and right accordion panels
to the vertical window sashes. Drill pilot
holes and attach the top and bottom
corners with 5 type B screws.
[] INSTALL SUPPORT BRACKET AND
FOAM TOP WINDOW GASKET
CAUTION:
To prevent broken glass
or damage to windows,
on vinyl or other
similarly constructed
windows, attach the
window locking bracket
to the window side jamb.
Attach the window
locking bracket with one
Type B screw.
Cut the foam top window gasket to the
window width.
Stuff the foam
between the
glass and the
window to
prevent air and
insects from
getting into the room.
NOTE: If the gasket supplied does not fit
your window, obtain appropriate material
locally to provide a proper installation seal.
Vinyl
Wood
J
Type B
screw
Type B screw
and sash lock
Top mounting rail
and Type B screw
Type B
screw
Type B screw
and sash lock
12
Installation instructions
[_ iNSTALL THE AiR CONDiTiONER
iN THE CASE
[] Make sure the __]_l
ground wire is
off to the side
and slide the
air conditioner
into the case.
Do not push
on the controls
or the finned coils. Make sure the air
conditioner is firmly seated.
[]
Reattach the grounding wire with the screw
removed earlier.
[_ Reattach the front housing and replace the
screws.
[_ Install the filter.
F_ The adhesive foam strips provided can be
used to fill any gaps after the installation of
the air conditioner.
[] Plug in the air conditioner.
13
TroubleshootingTips.
Possible Causes What To Do
Air conditioner The air conditioner = Mal<e sure tile ah conditioner plug is pushed
doesnot start is unplugged, completely into the outlet.
The fuse is blown/drcuit =Check the house fl_se/circuit breaker box and replace
breaker is tripped, die fl_se or reset the breaker;
Power failure. * The unit will automatically restart in die settings last
used after file power is restored°
There is a protective time delay (approximately
3 minutes) to prevent tripping of the compressor
overload. For this reason, the unit may not start
normal cooling for 3 minutes after it is turned
back on.
The current interrupter * Press the RESETbutton k)cated on the power cord plug.
device is tripped. * if the RESErbumm will not stay engaged, discontinue
use of the air conditioner and contact a qualified
service technician.
Air conditioner does Airflow is restricted. *Make sure there are no curtains, blinds or fl_rnimre
not cool as it should bk)cking the flont of the air conditkmec
The temp control may * in the Cool mode, press the Decrease W pad.
not be set correctly.
The air Fdter is dirty. * Clean the filter at least eveQ' 30 days.
See the Care and CleaRing section.
The room may have been hot. _ _qlen the air conditioner is first turned on, you need
Cold air is escaping. * Check for open furnace registers and cold air returns.
Cooling coils have iced up. _ See "Air conditioner freezing up" below.
Air conditioner Ice blocks the air flow *Set the controls at High Fanor High COOl and set the
freezing Up and stops the air conditioner thermostat to a higher temperature.
from cooling the room.
The remote control The batteries are inserted _ Check the position of the batteries° They should be
is not working incorrectly, inserted in the opposite (+) and (-) direction.
The batteries may be dead. * Replace the batteries.
Water dripsoutside Hot, humid weather. * Tiffs is normal
Water drips indoors The air conditioner is not * For proper water disposal, make sure the air conditioner
tilted to the outside, slants slightly flom the c_se flont to the rear
_in Moisture removed from air * Tiffs is normal ff)r a short period in areas with little
to allow time for the room to cool down.
basepan and drains into base pan. lmmidity; nomm/ff)r a kruger period in veQ' lmmid areas.
Normal Operating Sounds
You may hear a pinging noise caused by water
being picked up and finown against tlle
condenser on rai W days or when the humidit?.
is high. This design feature helps remcwe
moisture and imprcwe efficiency.
}_You may' hear the themlosmt click when the
conlpressor cycles on and off.
Wamr will collect in file base pan during
high lmmidity or on rainy days. The water
may overflow and drip flom the outdoor side
of the unit.
}_The tim may run even when the compressor
does not.
14
Please place in envelope and mail to:
Veuillez mettre dans une enveloppe et envoyez _ :
OWHERSHIPREGISTRATIOH
P.O. BOX1780
MISSJSSAUGA,OHTARIO
L4Y4G1
(FORCAHADIAHCOHSUMERSOHLY)
15
For Canadian
Customers
Pour les
Consommateurs
Canadiens
Pleaseregisteryourproducttoenableustocontactyou
intheremoteeventasafetynoticeisissuedforthisproduct
andto aUow for efficient communication under the terms
z:
of your warrant_; should the need arise.
I
REGISTERON-UNE: wvwv, geappliances.ca MAILTO:,
CCI
ENREGISTREMENTSUR INTERNETA: www.electromenagersge.ca POSTERA:
L3_
Z _
[][] MISS/MLLE.MR'/M[][] Ms.MRS'/MME"FIRSTNAME/PRt_NOM LASTNAME/NOM
rr-B
I
STREETNO/N° RUE STREETNAME/RUE
C31
CiTY/VILLE
Z I
<i
kkll
Z_
I
m,
DIDYOUPURCHASEASERVICECONTRACTFORTHISAPPLIANCE?
AVEZ-VOUSACHETEUNCONTRATDESERVICEPOURCETAPPAREIL?
ZI
NAMEOF SELLINGDEALER/ NOMDU MARCHAND
I
I--B
INSTALLATIONDATE/DATEDIINSTALLA]ION/
Y/A M D/J CORRESPONDENCE [] ENGLISH
[] Ido notwishtoreceiveanypromotionaloffers_egardingthisproduct.
D Jenedesirepasrecevoird'offrespromotionnellesconcemantce produit.
CORRESPONDANCE [] FRANOAIS
J
[,oo
VeuiUezenregi_ervotreproduitafindenouspermei_ede
communiqueravecvoussijamaisunavisdes_curit6concemant
ceproduit_¢ait_misetdecommuniquerfacibmentavecvousen
vertudevol_egarar_e,silebesoinsenfairsentir.
P.O.BOX1788,MISSISSAUGA
ONTARIO,L4Y461
PROVINCE POSTALCODE/POSTAL
YES/OUI[]
NO/NOND
MODEL/MOD_:LE
SERIAL/Sl_RIE
IFYES/SIOUhEXPIRATION
Y/A M D/J
APT.NO/APP./RR#
16
GEAir Conditioner--One YearLimitedWarranty.marc,stomersi,theU.S.A.)
Aft warranty service provided by our Factory Service Centers,
or an authorized Customer Care_ technician. Toschedule service,
visit us on-line at GEAppliances.com, or carl 800,GE.CARES
(800,432,2737).Have serial number and model number available
when cafling for service.
GE Will Replace:
OneYear
Fromthedate of the
originalpurchase
Service trips to your home to teach you how to use the
product.
Improper installation, delivery or maintenance. If you
have an installation problem, or if the air conditioner
is of improper cooling capacity for the intended use,
contact your dealer or installer. You are responsible for
providing adequate electrical connecting facilities.
Failure of the product resulting from modifications to
the product or due to unreasonable use including failure
to provide reasonable and necessary maintenance.
In commercial locations, labor necessary to move the unit
to a location where it is accessible for service by an
individual technician.
Anypartof the air conditioner which fidls due to a defec[ in materials or workmanship.
Dudng this limited one-year warranty, GE will else provide, free of charge, all labor and relamd
service to replace the defective part°
Staple your receipt here.
Proof of the original purchase date
is needed to obtain service under
the warranty.
Replacement of house fuses or resetting of circuit
breakers.
Failure due to corrosion on models not corrosion-
protected.
Damage to the product caused by improper power
supply voltage, accident, fire, floods or acts of God.
Incidental or consequential damage caused by possible
defects with this air conditioner.
Damage caused after delivery.
EXCLUSION OFIMPLIED WARRANTIES--Your sole and exclusive remedy is product repa# as provided & this
Limited Warranty. Any implied warranties, including the implied warranties of merchantability or fitness for a
particular purpose, are limited to one year or the shortest period allowed by law.
Th& warranty & extended to the original purchaser and any succeeding owner for products purchased for home
use within the USA. If the product is located in an area where service by a GEAuthorized Servicer is not available,
you may be responsible for a trip charge or you may be required to bring the product to an Authorized GEService
location for service. In Alaska, the warranty excludes the cost of shipping or service calls to your home.
Some states do not afiow the exclusion or limitation of incidental or consequential damages. This warranty gives
you specific legal rights, and you may also have other rights which vary from state to state. Toknow what your
legal rights are, consult your local or state consumer affairs office or your state's Attorney General
Warrantor: General Electric Company. Louisville, KY 40225
77