GE AJCH10ACA Specification

Page 1
AJCH10ACA—GE 115 Volt Built-In ”J Series” Room Air Conditioner with Mechanical Controls
Specification Created 5/01
GE Appliances
26
15-5/8
16-7/8
Wall Case Dimensions (in inches)
115V 15 Amp
R
R
Total capacity and E.E.R. ratings are calculated based on the Association of Home Appliance Manufacturers’ standards.
Listed by Underwriters Laboratories
For answers to your Monogram,® GE Profile™or GE appliance questions, visit our website at GEAppliances.com or call GE Answer Center®service, 800.626.2000.
Note: When installing slide-out chassis units in through- the-wall applications. Do not restrict air flow areas.
Page 2
Specification Created 5/01
GE Appliances
AJCH10ACAGE 115 Volt Built-In J Series Room Air Conditioner with Mechanical Controls
Brick Block and Brick Frame Construction
Fill open cells with mortar or insulation
15-3/4
26-1/8
Lintel
Dimensions (in inches)
Installation Information: A finished opening of
26-1/8" x 15-3/4" clear of intrusions is required. Keep clearance of 4" from side walls. Brick veneer or frame walls should have wood studding surrounding case to provide firm anchoring with screws. Case can be fastened directly to brick or block walls with screws sunk in lead expansion shields.
Note: Units should be caulked on all four sides of case to the building exterior to assure building integrity.
Two Wall Cases for Tenant Option Installation
When the air conditioner is offered as a tenant option, these wall cases provide protection against outside elements. RAB47–includes wall case, exterior grille and steel closure panels. RAB48–includes wall case, exterior grille, steel closure panel and two layers of insulation.
Standard Wall Case RAB46
Solid-sided wall case fabricated of galvanized steel with baked enamel finish. Welded areas are coated with a sealing compound to help resist rust and corrosion. Polymer gasket surrounds opening to assure tight weather seal. Aluminum grille (RAG13) is included. Panels on interior and between case and grille provide weather protection prior to installation of chassis.
Make frame if desired or caulk between case and siding
15-3/4
26-1/8
Frame Construction
Lintel
OUTSIDE INSIDE
16-7/8
Caulking
Drip Rail
Trim Molding (if desired)
Plaster Line
Flexible Mounting Position
R
R
Total capacity and E.E.R. ratings are calculated based on the Association of Home Appliance Manufacturers standards.
Listed by Underwriters Laboratories
For answers to your Monogram,® GE Profile™or GE appliance questions, visit our website at GEAppliances.com or call GE Answer Center®service, 800.626.2000.
Page 3
Specification Created 5/01
GE Appliances
AJCH10ACAGE 115 Volt Built-In J Series Room Air Conditioner with Mechanical Controls
Features and Benefits
9,000 BTUH, 115 Volts
9.2 E.E.R.
Mechanical Controls with Variable Setting Thermostat
2 Cooling/2 Fan Only Speeds
Fan Cycle Switch for Reduced Energy Consumption
Slide-Out Chassis
250/210 Airflow (CFM) Roomside Hi/Low
Exhaust for Air Exchange
2.7 Dehumidification (pints/hr)
Slide-Out Filter for Easy Cleaning
1075 Watts / 9.7 Amps
Wall CaseOptional Accessory (RAB46/47/48)
Plug Type–Parallel
Rotary Compressor
Model AJCH10ACA