GE AGL06, AGQ06, AGV06 User Manual

Safety Instructions . . . . . . . . . . .2, 3

Operating Instructions

Control knob models . . . . . . . . .6, 7
Touch pad models . . . . . . . . . . . .4, 5

Care and Cleaning

Air Filter . . . . . . . . . . . . . . . . . . . . . .8
Front Grille and Case . . . . . . . . . . .8
Normal Operating Sounds . . . . . . .8
Installation Instructions . . . . .9–13
Troubleshooting Tips . . . . . . . . .14

Consumer Support

Consumer Support . . . . . . . . . . . .18
Product Registration . . . . . . . .15, 16
Warranty . . . . . . . . . . . . . . . . . . . . .17
3828A20514C 49-7492 11-04 JR
AGF05
AGM05
AGL06
AGQ06
AGV06
Owner’s Manual and
Installation Instructions
Write the model and serial numbers here:
Model # __________________________
Serial # __________________________
Find these numbers on a label on the side of the air conditioner.
Air Conditioners
www.GEAppliances.com
Room
Consumer Support

Troubleshooting Tips Operating Instructions Safety InstructionsInstallation Instructions

2
IMPORTANT SAFETY INFORMATION. READ ALL INSTRUCTIONS BEFORE USING.
WARNING!
For your safety, the information in this manual must be followed to minimize the risk of fire, electric shock or personal injury.
Use this appliance only for its intended
purpose as described in this Owner’s Manual.
This air conditioner must be properly
installed in accordance with the Installation Instructions before it is used.
Never unplug your air conditioner by
pulling on the power cord. Always grip plug firmly and pull straight out from the receptacle.
Repair or replace immediately all electric
service cords that have become frayed or otherwise damaged. Do not use a cord that shows cracks or abrasion damage along its length or at either the plug or connector end.
Turn the mode control to OFF and unplug
your air conditioner before making any repairs or cleaning.
NOTE: We strongly recommend that any servicing be performed by a qualified individual.
For your safety…do not store or use
combustible materials, gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance.
All air conditioners contain refrigerants,
which under federal law must be removed prior to product disposal. If you are getting rid of an old product with refrigerants, check with the company handling disposal about what to do.
SAFETY PRECAUTIONS
Do not, under any circumstances, cut or remove the third (ground) prong from the power cord. For personal safety, this appliance must be properly grounded.
The power cord of this appliance is equipped with a 3-prong (grounding) plug which mates with a standard 3-prong (grounding) wall outlet to minimize the possibility of electric shock hazard from this appliance.
Power cord may include a current interrupter device. A test and reset button is provided on the plug case. The device should be tested on a periodic basis by first pressing the TEST button and then the RESET button. If the TEST button does not trip or if the RESET button will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician.
Have the wall outlet and circuit checked by a qualified electrician to make sure the outlet is properly grounded.
Where a 2-prong wall outlet is encountered, it is your personal responsibility and obligation to have it replaced with a properly grounded 3-prong wall outlet.
The air conditioner should always be plugged into its own individual electrical outlet which has a voltage rating that matches the rating plate.
This provides the best performance and also prevents overloading house wiring circuits which could cause a fire hazard from overheated wires.
See the Installation Instructions, Electrical Requirements section for specific electrical connection requirements.
HOW TO CONNECT ELECTRICITY
3
Consumer SupportTroubleshooting TipsOperating InstructionsSafety Instructions Installation Instructions
WARNING!
Because of potential safety hazards under certain conditions, we strongly recommend against the use of an extension cord.
However, if you must use an extension cord, it is absolutely necessary that it be a UL-listed, 14 gauge, 3-wire grounding type appliance extension cord having a grounding type plug and outlet and that the electrical rating of the cord be 15 amperes (minimum) and 125 volts.
CAUTION:
DO NOT use an extension cord with any of the 230/208 volt models.
USE OF EXTENSION CORDS—115-Volt models only
Because of potential safety hazards under certain conditions, we strongly recommend against the use of an adapter plug.
However, if you must use an adapter, where local codes permit, a temporary connection may be made to a properly grounded 2-prong wall outlet by use of a UL-listed adapter available at most local hardware stores.
The larger slot in the adapter must be aligned with the larger slot in the wall outlet to provide proper polarity in the connection of the power cord.
When disconnecting the power cord from the adapter, always hold the adapter in place with one hand while pulling the power cord plug with the other hand. If this is not done, the adapter ground terminal is very likely to break with repeated use.
If the adapter ground terminal breaks, DO NOT USE the air conditioner until a proper ground has been established.
Attaching the adapter ground terminal to a wall outlet cover screw does not ground the appliance unless the cover screw is metal, and not insulated, and the wall outlet is grounded through the house wiring. You should have the circuit checked by a qualified electrician to make sure the outlet is properly grounded.
USE OF ADAPTER PLUGS—115-Volt models only
READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY.
SAVE THESE INSTRUCTIONS
www.GEAppliances.com
Consumer Support
Troubleshooting Tips Operating Instructions Safety InstructionsInstallation Instructions
To ensure proper operation, aim the remote
control at the signal receiver on the air conditioner.
The remote control signal has a range of
up to 21 feet.
Make sure nothing is between the air conditioner
and the remote control that could block the signal.
Make sure batteries are fresh and installed
correctly as indicated on the remote control.
About the controls on the air conditioner—models with touch pads.
Features and appearance will vary.
4
Air Conditioner Controls
Remote Control
Controls
ON/OFF Pad
Turns air conditioner on and off.
Display
Shows the set temperature or time remaining on timer.
MODE
Use to set the air conditioner to COOL or FAN mode.
Increase /Decrease Pads
Use to set temperature when in COOL mode.
FAN Pad
Use to set the fan speed to LOW (F1), MED (F2) or HIGH (F3).
ENERGY SAVER (on some models)Controls
the fan.
ON—The fan and compressor cycle on and off. This results in wider variations of room temperature and humidity. Normally used when the room is unoccupied. NOTE: The fan
will continue to run for a short time after the compressor cycles off.
OFF—The fan runs all the time, while the compressor cycles on and off.
This feature must be set at OFF in order to use the fan settings (on the mode control).
TIMER Pad
ON—When the air conditioner is off, it can be
set to automatically come on in 1 to 12 hours or 1 to 24 hours (depending on model) at its previous setting. Each touch will set the timer in hours.
OFF—When the air conditioner is on, it can be set to automatically turn off in 1 to 12 hours or 1 to 24 hours (depending on model). Each touch will set the timer in hours.
To cancel the timer, press the TIMER pad until the display time disappears.
Remote Control Signal Receiver
Remote Control
Fan on
Cool on
Time r on
Energy Saver on
www.GEAppliances.com
Lights next to the touch pads on the air conditioner control panel indicate the selected settings.
COOL Mode
Use the COOL mode with HIGH (F3), MED (F2) or LOW (F1) fan for cooling. Use the INCREASE / DECREASE pads to set the desired temperature
between 60°F and 86°F in 1°F increments.
An electronic thermostat is used to maintain the room temperature. The compressor will cycle on and off to keep the room at the set level of comfort. Set the thermostat at a lower number and the indoor air will become cooler. Set the thermostat at a higher number and the indoor air will become warmer.
NOTE: If the air conditioner is off and is then turned on while set to COOL, it will take approximately 3 minutes for the compressor to start and cooling to begin.
Cooling Descriptions
For Normal Cooling—Select the COOL mode and HIGH (F3) or MED (F2) fan with a middle set
temperature.
For Maximum Cooling—Select the COOL mode and HIGH (F3) fan with a lower set temperature.
For Quieter & Nighttime Cooling—Select the COOL mode and LOW (F1) fan with a middle set
temperature.
NOTE: If you switch from a COOL setting to OFF or to a fan setting, wait at least 3 minutes before switching back to a COOL setting.
FAN Mode
Use the FAN at HIGH (F3), MED (F2) or LOW (F1) to provide air circulation and filtering without cooling. Since fan only settings do not provide cooling, a temperature setting will not be displayed.
Consumer SupportTroubleshooting TipsOperating Instructions
Safety Instructions
Installation Instructions
5
Air Direction
Fingertip pressure on the louvers lets you control the air direction left, right, straight ahead or any combination of these directions.
Additional controls and important information.
Power Outage Recovery Feature
In the case of a power outage or interruption, the unit will automatically re-start in the settings last used after the power is restored. The TIMER feature will reset to the original setting. You may need to set a new time if desired.
About the controls on the air conditioner—models with control knobs.
Features and appearance will vary.
Controls
Mode Control
HI COOL , MED COOL and LOW COOL provide
cooling with different fan speeds.
HI FAN and LOW FAN provide air circulation and filtering without cooling.
NOTE: If you move the mode control from a cool setting to OFF or to a fan setting, wait at least 3 minutes before switching back to a cool setting.
Cooling Descriptions
For Normal Cooling—Select HI COOL or MED COOL
with the temp control at midpoint.
For Maximum Cooling—Select HI COOL with the temp control at the highest number available on your knob.
For Quieter & Nighttime Cooling—Select LOW COOL with the temp control at midpoint.
Temp Control
The temp control is used to maintain the room temperature. The compressor will cycle on and off to keep the room at the same level of comfort. When you turn the knob to a higher number the indoor air will become cooler. Turn the knob to a lower number and the indoor air will become warmer.
MODE
Your model will have one of the above type controls.
TEMP
Your model will have one of the above type controls.
Consumer Support
Troubleshooting Tips Operating Instructions Safety InstructionsInstallation Instructions
6
HI
FAN
LOW FAN
OFF
LOW
COOL
HI
COOLHICOOL
MED
COOL
HI
FAN
LOW
FAN
OFF
34
2
1
6
5
45
3
2
1
COOL
COOL
6
8
HI
LOW
7
Consumer SupportTroubleshooting TipsOperating InstructionsSafety Instructions Installation Instructions
7
Air Direction
Fingertip pressure on the louvers lets you control the air direction left, right, straight ahead or any combination of these directions.
www.GEAppliances.com
Additional controls and important information.
Care and cleaning of the air conditioner.
8
Consumer Support
Troubleshooting Tips Operating Instructions Safety InstructionsInstallation Instructions
The air filter behind the front grille should be checked and cleaned at least every 30 days or more often if necessary.
Clean the filter with warm, soapy water. Rinse and let the filter dry before replacing it.
CAUTION: DO NOT operate the air
conditioner without a filter because dirt and lint will clog it and reduce performance.
To remove (on some models):
Grasp the tab and gently pull the filter up and out.
To remove (on some models):
Open the inlet grille downward by pulling out the upper corners of the inlet grille.
Using the tab, push down on the filter to release it and pull it out.

Outdoor Coils

The coils on the outdoor side of the air conditioner should be checked regularly. If they are clogged with dirt or soot they may be professionally steam cleaned, a service available through your GE service outlet.

Air Filter

Filter
tab
Grasp
corner
Grasp
corner

Front Grille and Case

Turn the air conditioner off and remove the plug from the wall outlet before cleaning.
To clean, use water and a mild detergent. Do not use bleach or abrasives.

Normal Operating Sounds

You may hear a pinging noise caused by
water being picked up and thrown against the condenser on rainy days or when the humidity is high. This design feature helps remove moisture and improve efficiency.
You may hear the thermostat click when the
compressor cycles on and off.
Water will collect in the base pan during
high humidity or on rainy days. The water may overflow and drip from the outdoor side of the unit.
The fan may run even when the compressor
does not.
TOOLS YOU WILL NEED
Installation
Air Conditioner
Instructions
Phillips head screwdriver
Ruler or tape measure
Pencil
Level
Scissors or knife
9
Flat-blade screwdriver
CAUTION:
Do not, under any circumstances, cut or remove the third (ground) prong from the power cord.
Do not change the plug on the power cord of this air conditioner.
Aluminum house wiring may present special problems—consult a qualified electrician.
Questions? Call 800.GE.CARES (800.432.2737) or Visit our Website at: www.GEAppliances.com
BEFORE YOU BEGIN
Read these instructions completely and carefully.
IMPORTANT — Save these
instructions for local inspector’s use.
IMPORTANT — Observe all
governing codes and ordinances.
Note to Installer – Be sure to leave these instructions with the Consumer.
Note to Consumer – Keep these instructions for future reference.
Skill level – Installation of this appliance requires basic mechanical skills.
Completion time – Approximately 1 hour
We recommend that two people install
this product.
Proper installation is the responsibility of the installer.
Product failure due to improper installation is not covered under the Warranty.
ELECTRICAL REQUIREMENTS
Some models require a 115/120-volt a.c., 60 Hz grounded outlet protected with a 15-amp time delay fuse or circuit breaker.
The 3-prong grounding plug minimizes the possibility of electric shock hazard. If the wall outlet you plan to use is only a 2-prong outlet, it is your responsibility to have it replaced with a properly grounded 3-prong wall outlet.
Some models require 230/208-volt a.c., protected with a time delay fuse or circuit breaker. These models should be installed on their own single branch circuit for best performance and to prevent overloading house or apartment wiring circuits, which could cause a possible fire hazard from overheating wires.
Power cord may include a current interrupter device. A test and reset button is provided on the plug case. The device should be tested on a periodic basis by first pressing the TEST button and then the RESET button. If the TEST button does not trip or if the RESET button will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician.
PARTS INCLUDED
(Appearance may vary)
10
Installation Instructions
Window sash seal
Support brackets (3)Type A (5) Type B (11)
Top mounting rail
Side
accordion
panels
Security bracket (1)
Foam top window gasket
Air conditioner
11
Installation Instructions
WINDOW REQUIREMENTS
These instructions are for a standard double-hung window. You will need to modify them for other types of windows.
The air conditioner can be installed without the accordion panels if needed to fit in a narrow window. See the window opening dimensions.
All supporting parts must be secured to firm wood, masonry or metal.
The electrical outlet must be within reach of the power cord.
1
13min.
22to 36
(With accordion panels)
18
3
4min.
(Without accordion panels)
STORM WINDOW REQUIREMENTS
A storm window frame will not allow the air conditioner to tilt toward the outside, and will keep it from draining properly. To adjust for this, attach a piece of wood to the stool.
WOOD PIECES— WIDTH: 2 LENGTH: Long enough to fit inside the
window frame. THICKNESS: To determine the thickness,
place a piece of wood on the stool to make it 1/2higher than the top of the storm window frame.
Attach securely with nails or screws provided by the installer.
2
1/2″ higher than frame
Storm window frame
Wood
Stool
PREPARE THE WINDOW
Cut the window sash seal to the window width and stick the adhesive side to the bottom of the sash.
Mark the centerline of the sill. Measure and mark the locations for the support brackets 8from both sides of the centerline.
Place 2 support brackets on the sill, against the back edge of the stool with their holes centered on each 8mark.
Attach them to the sill with one Type B screw through each support bracket.
D
C
B
A
3
Window
sash seal
INSIDE
Stool
Outside
Inside
Support bracket
Sill
Type B screw
Support bracket
Loading...
+ 25 hidden pages