As an ENERGY STAR® partner, GE has
determined that this product meets
the ENERGY STAR® guidelines for
energy efficiency.
Write the model and serial numbers here:
Model # _________________________
Serial # __________________________
Find these numbers on a label on the side of
Air Conditioners
the air conditioner.
49-7730 11-13 GE
IMPORTANT SAFETY INFORMATION.
READ ALL INSTRUCTIONS BEFORE USING.
WARNING!
For your safety, the information in this manual must be followed to minimize the risk of fire, electric
shock or personal injury.
SAFETY PRECAUTIONS
Use this appliance only for its intended
purpose as described in this Owner’s
Manual.
This air conditioner must be properly
installed in accordance with the Installation
Instructions before it is used.
Never unplug your air conditioner by pulling
on the power cord. Always grip plug firmly
and pull straight out from the receptacle.
Replace immediately all electric service
cords that have become frayed or otherwise
damaged. A damaged power supply cord
must be replaced with a new power supply
cord obtained from the manufacturer and
not repaired. Do not use a cord that shows
cracks or abrasion damage along its length
or at either the plug or connector end.
If the receptacle does not match the plug,
the receptacle must be changed out by a
qualified electrician.
Turn the unit OFF and unplug your air
conditioner before making any repairs
or cleaning.
NOTE: We strongly recommend that any
servicing be performed by a qualified
individual.
For your safety…do not store or use
combustible materials, gasoline or other
flammable vapors or liquids in the vicinity
of this or any other appliance.
All air conditioners contain refrigerants,
which under federal law must be removed
prior to product disposal. If you are getting
rid of an old product with refrigerants, check
with the company handling disposal about
what to do.
These R410A air conditioning systems
require contractors and technicians to use
tools, equipment and safety standards
approved for use with this refrigerant.
DO NOT use equipment certified for R22
refrigerant only.
HOW TO CONNECT ELECTRICITY
Do not, under any circumstances, cut or remove
the third (ground) prong from the power cord.
For personal safety, this appliance must be
properly grounded.
DO NOT use an adapter plug with this
appliance.
The power cord of this appliance is equipped
with a 3-prong (grounding) plug which mates
with a standard 3-prong (grounding) wall outlet
to minimize the possibility of electric
shock hazard from this appliance.
Power cord includes a current interrupter device.
A test and reset button is provided on the plug
case. The device should be tested on a periodic
basis by first pressing the TEST button and then
the RESET button while plugged into the outlet. If
the TEST button does not trip
or if the RESET button will not stay engaged,
discontinue use of the air conditioner and
contact a qualified service technician.
2
Have the wall outlet and circuit checked by
a qualified electrician to make sure the outlet
is properly grounded.
Where a 2-prong wall outlet is encountered,
it is your personal responsibility and obligation to
have it replaced with a properly grounded
3-prong wall outlet.
The air conditioner should always be plugged
into its own individual electrical outlet which has
a voltage rating that matches the rating plate.
This provides the best performance and also
prevents overloading house wiring circuits which
could cause a fire hazard from overheated wires.
See the Installation Instructions, Electrical Requirements section for specific electrical
connection requirements.
GEAppliances.com
WARNING!
USE OF EXTENSION CORDS
RISK OF FIRE. Could cause serious injury or
death.
• DO NOT use an extension cord with this
Window Air Conditioner.
• DO NOT use surge protectors or multi-outlet
adaptors with this Window Air Conditioner.
READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY.
SAVE THESE INSTRUCTIONS
3
About the controls on the air conditioner.
Features and appearance will vary.
Lights next to the touch pads on the air conditioner control panel indicate the selected settings.
Light indicates the unit is in the
temperature or delay time Set mode.
Light indicates the
delay timer is set.
Power
On/Off
Auto
High
Med
Low
FanMode
NOTE: The display always shows the room temperature except
when setting the Set temperature or the Delay timer.
Cool
Fan Only
Energy Saver
Set
Reset
Filter
Air Conditioner Controls
Controls
Power Pad
Turns air conditioner on and off. When
turned on, the display will show the room
temperature.
Display
Shows the room temperature or time
remaining on the Delay timer. Shows the Set
temperature while setting the temperature in
Cool or Energy Saver modes. The Set light will
turn on while setting.
Temp Increase Ÿ /Decrease ź Pads
Use to set temperature when in Cool or
Energy Saver mode. The Set light will turn on
while setting.
Delay Timer IncreaseŸ (+) /Decrease
ź(–) Pads
Each touch of the Increase Ÿ / Decrease ź
pads on the unit or the Increase + / Decrease
– pads on the remote control will set the delay
time when using the Delay 1–24hrtimer. The
Set light will turn on while setting.
Fan Speed Pads
Use to set the fan speed to Low, Med, High
or Auto on the unit. NOTE: On the remote
control, use the fan speed Increase + /
Decrease –pads to set the fan speeds to Low,
Med or High. Use the Auto pad to turn Auto
fan on.
+
-
Delay
1-24 Hrs
Delay 1–24hr
Delay timer
Decrease
Mode select
Fan speed
Decrease
Temperature
8
set Increase
and Decrease
FanFan
Delay
timer
Increase
Auto Fan
on
Fan speed
Increase
Unit power
on/off
Remote Control
Mode Pad
Use to set the air conditioner to Cool, Energy
Saver or Fan Only mode.
Delay Pads/Delay 1-24hr Pad
'HOD\21³When the air conditioner is off, it can
be set to automatically come on in 1 to 24 hours
at its previous mode and fan settings.
'HOD\2))³When the air conditioner is on,
it can be set to automatically turn off in 1 to
24 hours.
How to set:
Press the Delay 1–24hr pad on the unit or the
Delay pad on the remote control. Each touch
of the Increase Ÿ/ Decreaseźpads on the
unit or the Increase
the remote control will set the timer in 1-hour
intervals. The Set light will turn on while setting.
To review the remaining time on the Delay 1–24hr timer, press the Delay 1–24hr pad on
the unit or the Delay pad on the remote control.
Use the Increase Ÿ / Decrease ź pads on the
unit or the Increase
remote control to set a new time if desired.
To cancel the timer, press the Delay 1–24hr pad
until the light on the Delay 1–24hr pad goes off.
Reset Filter
LED will turn on when fan has accumulated 250
hours of run time as a reminder to clean filter.
Press Reset Filter to turn off the LED and reset
the accumulated run time.
+ / Decrease – pads on
+ / Decrease – pads on the
Note: The default temperature reading on the display is degree Fahrenheit ( °F). To change the display to
degree Celcius (°C), press the Temp Increase Ÿ and Temp Decrease ź buttons together and hold for 3
4
seconds. Repeat the process to change back to degree Fahrenheit (°F)
GEAppliances.com
Do Not Operate in Freezing Outdoor Conditions
This cool-only air conditioner was not designed for
freezing outdoor conditions. It must not be used in
freezing outdoor conditions.
Remote Control
To ensure proper operation, aim the remote
control at the signal receiver on the air
conditioner.
Make sure nothing is between the air conditioner
and the remote control that could block the
signal.
The remote control signal has a range of
up to 20 feet.
Make sure batteries are fresh and installed
correctly as indicated on the remote control.
Remote contains a magnet allowing it to attach
to metal surfaces.
Cool Mode
Use the Cool mode at Low, Med, High or Auto Fan
Speed for cooling. Use the Temperature Increase Ÿ
/ Decreaseź pads to set the desired temperature
between 64°F and 86°F in 1°F increments.
An electronic thermostat is used to maintain the room
temperature. The compressor will cycle on
and off to keep the room at the set level of comfort.
Set the thermostat at a lower number and the indoor
air will become cooler. Set the thermostat at a higher
number and the indoor air will become warmer.
NOTE: If the air conditioner is off and is then turned on
while set to a Cool setting or if turned from a fan
setting to a Cool setting, it may take approximately
3 minutes for the compressor to start and cooling to
begin.
Cooling Descriptions
For Normal Cooling³6HOHFWWKHCool mode and
High or Med fan with a middle set temperature.
For Maximum Cooling³6HOHFWWKH Cool mode and High fan with a lower set temperature.
For Quieter and Nighttime Cooling³6HOHFWWKH
Cool mode and Low fan with a middle set
temperature.
Energy Saver Mode
This mode optimizes the cooling power of your air
conditioner, thereby saving you energy. Once the
set point temperature has been reached, the fan
will cycle off to save energy. The fan will cycle back
on periodically to insure all cooling capacity in the
system is used. This mode is the default mode for the
unit. Each time the unit is powered off, it will restart
in Energy Saver mode ON. This includes Delay timer
mode. The first time the unit is turned on, the settings
will be 70° and Low fan. You can adjust the fan
speed and temperature to your personal comfort.
Fan Only Mode
Use the Fan Only Mode at Low, Med or High fan
speed to provide air circulation and filtering without
cooling. Since fan-only settings do not provide
cooling, a Set temperature cannot be entered. The
room temperature will appear in the display.
Auto Fan Speed
Set to Auto fan speed for the fan speed to
automatically set to the speed needed to provide
optimum comfort settings with the set temperature.
If the room needs more cooling, the fan speed
Energy Saver ON³Helps minimize electricity use.
It is normal for the fan to cycle off and then back
on in this mode. This on/off cycle can repeat
multiple times. Because the fan will cycle off, you
may notice a variation in room temperature and
humidity.
Energy Saver OFF³When this mode is not engaged,
the fan will run continuously, and in Cool mode the
compressor will cycle on and off to maintain room
temperature.
NOTE: Auto Fan Speed cannot be used when in the
Fan Only Mode.
will automatically increase. If the room needs less
cooling, the fan speed will automatically decrease.
NOTE: Auto Fan Speed cannot be used when in the
Fan Only Mode.
Power Outage Recovery Feature
In the case of a power outage or interruption, the
unit will automatically restart in the settings last
used after the power is restored. If the Delay 1–24hr
feature was set, it will resume countdown. You may
need to set a new time if desired.
5
About the controls on the air conditioner
Additional important information.
Air Direction
Use the lever to adjust the air direction left and right
only.
Care and cleaning of the air conditioner.
Grille and Case
Turn the air conditioner off and remove the plug from
the wall outlet before cleaning.
Air Filter
The air filter behind the front grille should be checked
and cleaned at least every 30 days or
more often if necessary.
To clean, use water and a mild detergent. Do not use
bleach or abrasives.
To remove:
Open the inlet grille by pulling downward on the tabs
at the top upper corners of the inlet grille until the
grille is in a 45º position. Remove the filter.
Clean the filter with warm, soapy water. Rinse and let
the filter dry before replacing it. Do not clean the filter
in a dishwasher.
TabTab
CAUTION: DO NOT operate the air
conditioner without a filter because dirt and lint will
clog it and reduce performance.
Outdoor Coils
The coils on the outdoor side of the air conditioner
should be checked regularly. If they are clogged with
dirt or soot, they may be professionally cleaned.
How to Insert the Batteries in the Remote Control
Remove the battery cover by sliding it according
1
to the arrow direction.
Insert new batteries, making sure that the (+)
2
and (–) of battery are installed correctly.
Reattach the cover by sliding it back
3
into position.
6
NOTES:
Use 2 “AAA” (1.5 volt) alkaline batteries. Do not
use rechargeable batteries.
Remove the batteries from the remote control if
the system is not going to be used for a long time.
Do not mix old and new batteries. Do not mix
alkaline, standard (carbon-zinc) or rechargeable
(ni-cad, ni-mh, etc) batteries.
Installation
Air Conditioner
Instructions
Questions? Call 800.GE.CARES (800.432.2737) or visit our Website at: GEAppliances.com
BEFORE YOU BEGIN
Read these instructions completely
and carefully.
•
IMPORTANT ³ Save these instructions
for local inspector’s use.
•
IMPORTANT ³ Observe all governing
codes and ordinances.
•
Note to Installer – Be sure to leave these
instructions with the Consumer.
• Note to Consumer – Keep these instructions for
future reference.
• Skill level – Installation of this appliance requires
basic mechanical skills.
• Completion time –
• We recommend that two people install
this product.
• Proper installation is the responsibility
of the installer.
• Product failure due to improper installation is not
covered under the Warranty.
• You MUST use all supplied parts and use proper
installation procedures as described in these
instructions, and any separate kit instructions,
when installing this air conditioner.
Approximately 1 hour
CAUTION:
Do not, under any circumstances, cut or remove
the third (ground) prong from the power cord.
Do not change the plug on the power cord
of this air conditioner.
Aluminum house wiring may present special
SUREOHPV³FRQVXOWDTXDOLILHGHOHFWULFLDQ
If the sill support bolts do not contact the
window sill, or if you have a window without
a sill, you must order accessory kit RAK87
to properly install this air conditioner. Call
800.626.2002 or visit GEAppliances.com.
TOOLS YOU WILL NEED
Phillips head screwdriver
Adjustable wrench
ELECTRICAL REQUIREMENTS
Some models require a 115/120-volt AC,
60 Hz grounded outlet protected with a
15-amp time delay fuse or circuit breaker.
The 3-prong grounding plug minimizes the possibility
of electric shock hazard. If the wall outlet you plan to
use is only a 2-prong outlet,
it is your responsibility to have it replaced with
a properly grounded 3-prong wall outlet.
Some models require 230/208-volt AC,
protected with a time delay fuse or circuit
breaker. These models should be installed
on their own single branch circuit for best
performance and to prevent overloading
house or apartment wiring circuits, which
could cause a possible fire hazard from
overheating wires.
Flat-blade screwdriver
Pencil
Level
Power cord includes a current interrupter
device. A test and reset button is provided on the
plug case. The device should be tested on a periodic
basis by first pressing the TEST button and then the
RESET button while plugged into the outlet. If the
TEST button does not trip or
if the RESET button will not stay engaged, discontinue
use of the air conditioner and contact a qualified
service technician.
7
Ruler or tape measure
Scissors or knife
PARTS INCLUDED
(appearance may vary)
Installation Instructions
Window sash seal
(thin, adhesive-backed)
Foam top
window gasket
Left accordion
panel
Top mounting rail
seal strip
Type A (6)
Type B (7)
Type C (6)
Type D (3)
Sill support (2)
Nut (2)
Bolt (2)
Top mounting rail
Right
accordion
panel
Window locking
bracket (2)
8
Installation Instructions
WINDOW REQUIREMENTS
1
• These instructions are for a standard
double-hung window. You will need to modify
them for other types of windows.
3
REMOVE THE AIR CONDITIONER
FROM THE CASE
A
Remove and save the 2 screws from the lower
sides of the front grille.
CAUTION:
If the sill support
bolts do not contact the window sill, or
if you have a window without a sill, you
must order accessory kit RAK87 to
properly install this air conditioner.
Call 800.626.2002 or visit GEAppliances.com.
• The air conditioner can be installed without
the accordion panels if needed to fit in a
narrow window. See the window opening
dimensions.
• All supporting parts must be secured
to firm wood, masonry or metal.
• The electrical outlet must be within reach of
the power cord.
16.4” min.
25.25s to 38s
(With accordion panels)
FRONT
Grasp the lower corners of the grille while
B
pressing in on the case sides with your finger
tips. Pull out to release and lift it up.
NOTE: Do not pull the bottom edge toward you
more than 3s or you may damage the tabs of
the grille.
FRONT
STORM WINDOW REQUIREMENTS
2
A storm window frame will not allow the air
conditioner to tilt toward the outside, and will keep
it from draining properly. To adjust for this, attach
a piece of wood to the sill.
WOOD PIECES –
WIDTH: 2s
LENGTH: Long enough to fit inside the window
frame.
THICKNESS: To determine the thickness, place a
piece of wood on the sill to make it 1/2s higher
than the top of the storm window frame or the
vinyl frame.
Attach securely with nails or screws provided
by the installer.
1/2shigher
than vinyl frame
(on some windows)
1/2shigher
than storm
window
frame
Storm window
frame
Sill
Vinyl frame
Wood
Remove the ground screw from each side
C
of the case. Keep them in a safe location.
NOTE: Be sure to save these screws. You
will need them later in the installation.
FRONT
Slide the air conditioner from the case by
D
gripping the base pan handle and pulling
forward while bracing the case. Do not pull
or lift on the styrofoam discharge area.
Do not
pull or
lift in this
DUHD³
damage
to the
unit may
result
FRONT
9
Installation Instructions
ATTACH THE TOP MOUNTING RAIL
4
SEAL STRIP
Remove the backing from the top mounting rail
seal strip and attach the seal strip to the bottom
of the top maounting rail, along the front edge.
Allow the seal strip to overlap 3/8” on each end.
INSTALL THE
6
SIDE ACCORDION PANELS
Slide the left and right accordion panels into
A
the top and bottom mounting rails.
B
Attach the accordion panels to the case using 3
Type A screws on each side.
Top mounting rail
3/8”
Remove
backing
from seal
strip
3/8”
FRONT VIEW
3/8” overlap3/8” overlap
INSTALL THE TOP MOUNTING RAIL
5
Seal strip
Top mounting rail
ONTO THE CASE
Attach the top mounting rail onto the top of the
case with 3 Type B screws.
Type B
screws
Top mounting rail
Accordion
panel
Type A
screws
BACK
Bottom mounting rail
PREPARE THE WINDOW
7
• Cut the window sash seal to the window
width and stick the adhesive side to the
bottom of the sash.
Top
mounting
rail
Window sash
seal
INSIDE
10
Loading...