GE AGM14ACG1, ADV14AAG1, ADV12AAG1 Owner’s Manual

©
©
www.GEAppfiances.com
Safety Instruaions ........ 2, 3
Operating Instructions
Control Knob Models ...... 6, 7
Touch Pad Models ......... 4, 5
Care and Cleaning
Air Filter . ................. 8
Grille and Case ............. 8
()utdoor (:oils .............. 8
Installation Instructions
Air Conditioner . ............ 9
Window Installation ...... 10-14
Troubleshooting Tips ...... 15
Normal Operating Sounds . . .16
Consumer Support
Consumer Support ......... 20
Product Registration ..... 17, 18
_4'arranty ................. 19
A GF06
A (;M06
A GF08 AGL08
A CM08
A CN08
AC;QOS
A GV08 A CFI 0 AGLIO
A (;M l 0
A (;N l 0
AGVIO
M)Q12
ADVl2 A GFl 2
AGLl2
A CM l 2
ACNl2
ADQ14 ADVI4
A CFI 4
AGLI4
A CM l 4
ACNI4
©
Write the model and serial numbers here:
Model #
Serial #
Find these nmnbers on a label on the side of the air conditione_:
49-7483 12-03JR
IMPORTANTSAFETYINFORMATION. READALLINSTRUCTIONSBEFOREUSING.
WARNING!
For your safe_ the information in this manual must be followed to minimize the risk of fire, electric shock
or personal injurg
SAFETYPRECAUTIONS
_{_:Use this appliance only %r its intended
puq)ose as described in tills )wrier s Manual.
_{::This air conditioner must be properly
installed in accordance with tile Installation Instructions before it is used.
_::Nexer unplug your air conditioner by pulling
on the power cord. Always gdp plug firefly
and pull straight out fiom tile receptacle.
_: Repair or replace immediamly all elect3_ic
service cords that haxe become flwed or otherwise damaged. Do not use a cord dlat shows cracks or abrasion damag_ along its lenglh or at either the plug or connector end.
(
_?{::Turn tile mode control to OR:and unplug
_:;For your safety...do not store or use
;f; All air conditioners contain refl_igerants,
HOWTOCONNECTELECTRICITY
Do not, under any circumstances, cut or remove
the third (ground) prong from the power cord. For personal safe_ this appliance must be properly grounded.
Tile air conditioner should always be plug\g_d into its own individual electrical outlet which has a x_lmg_ rating fllat matches the rating plato.
your air conditioner before making any
repairs or cleaning.
NOTE"Westronglyrecommendthat anyservicing be performedbyaqualified individual.
combustible materials, gasoline or other flammable vapors or liquids in tile vicinity of this or any other appliance.
which under federal law must be removed prior to product disposal. If you are g>tfing
rid of an old product with refi_ig_rants, check
with tile company handling disposal about what to do.
Tile power cord of dfis appliance is equipped
with a 3-prong (gxounding) plug which mates with a standard 3-prong (grounding) wall
outlet m minimize the possibility of electric shock hazard fiom this appliance.
Hme tile wall outlet and circuit checked by a qualified electrician to make sure the outlet is
properly grounded.
Where a 2-prong wall outlet is encountered,
it is your personal responsibility and obligation to hme it replaced with a properly grounded
3-prong wall outlet.
This provides tile best performance and also prexents oxerloading house wiring circuits
which cou]d cause a fire hazard from
oxerheated wires. See the Installation Instructions, Electrical
Requirements section for specific electrical
connection requirements.
2
WARNING!
USEOFEXTENSIONCORDS--115-Voltmodelsonly
Because ofpotential safety hazards under certain.."CAUTION:
conditions, we strongly recommend against the use of an extension cord.
Howexei; if you must use an exmnsion cord, it is absolutely necessai T tllat it be a UiAismd,
14 gauge, 3-wire grounding type appliance
extension cord having a grounding type plug and outlet and that the electrical rating of file
cord be 15 amperes (nfininnnn) and 195 x_lts.
USEOFADAPTERPLUGS--115-Voltmodelsonly
DO NOT use an extensioncord with any of the 230/208 volt models.
GEAppliances.com
Because of potential safety hazards under certain conditions, we strongly recommend against the use of an adapter plug.
Howe\>i; if yon must use an adaptei; where local codes i)ermit, a temporaryconnectionmay be made to a i)roperly grounded 21)rong wall on0et l)y use of a UiAismd adaptor available
at nlost local hardware stores.
Tile larger slot ill tile adaptor nmst be alig_led with file larger slot in tile wall outlet to provide proper polarity ill the connection of the power cord.
When disconnecting fl)e power cold flom tile
adaptei; alwws hold the adapter ill place with one hand while I)ulling tile I)ower cord I)lug
with the other hand. If this is not done, tile
adaptor ground ml_ninal is x_U liken to bleak
with rei)eated use.
If tile adapter ground temfinal breaks, DO NOT
USEtile air conditioner until a proper ground
has been established.
Attachingthe adaptergroundterminalto a waftoutlet coverscrewdoesnot groundthe applianceunlessthe
coverscrewis metal, andnotlesulated,andthe waft outlet is groundedthroughthehousewiring. Youshould
havethecircuitcheckedby a quafifiedelectricianto makesuretheoutlet is properlygrounded.
READANDFOLLOWTHISSAFETYINFORMATIONCAREFULLY.
SAVETHESEINSTRUCTIONS
Aboutthe controlsontheair conditionermmodels with touchpads.
Features and appearance will vary.
FAN SPEED
Coolon -
Fanon Energy
Saveror
Energy Saveron
on
Air ConditionerControls Remote Control
Controls
O ON/OFF Pad
TtlFIIS air coilditioilei" oi1 aIld ()_.
Oisplav
Shows tile set temperature or time remaining
011 tiIlleI:
O MODE
Use to set tile air conditioner to COOLor
FAN mode.
Increase •/Decrease Pads
Use to set temperature when in COOLmode.
O FAN Pad
Use to set the fire speed to LOW(FI), MED (F2) or HIGH (F3).
O ENERGYSAVER(on some models)
Controls tile tim.
ON--The tim and compressor cycle on and
off. This results in wider \m'iations of room temperature and humidity. Nommllv used
when the room is tmoccupied. NOTE"Thefan
will continuetorun fora shortt/me after the
compressorcyciesoff.
OFF--The tim rtms all tile time, while tile
compressor cycles on and off. This fi_atm'e must be set at OFFin order to
use tile tim settings (on tile mode control).
Coolon 0
0
@
NOTE"Onsome models,the ENERGYSAVERfeature cannotbe set on the air conditioner /tmust be set using
theremote control.
O CIRCULAIRE (on some models)
For (olltiIltlOt/S side-to-side air circulation
(cool settings only), set tile Circulaire switch
to ON. For fixed side-to-side air direction, mrn ON
tmtil tile desired air direction is obt;fined, then turn it OFF.
O TIMER Pad
ON--'_._hen tile air conditioner is off, it can be
set to automatically come on in 1 to 12 hours or 1 to 24 hem's (depending on model) at its
previous setting. Each touch of tile TIMER pad or tile INCREASE •/DECREASE• pads
(depending on model) will set tile timer
in hours.
OFFi\'_llen tile air conditioner is on, it can be
set to automatically tun_ off in 1 to 12 hem's or
1 to 24 hom_ (depending on model). Each
touch of tile TIMER pad or tile INCREASE / DECREASE• pads (depending on model) will
set tile till/er ill hotlI_.
Tocancel the timer, press tile 77MERpad /mfil
tile display time disappears.
O Remote Control Signal Receiver
TIMER MODE
Remote Control
::Ji::To ensm'e proper operation, aim tile remote
control at the signal receiver on tile air
Collditiollei:
iJi::Tile remote control signal has a range of
up to 21 feet.
::Ji::Make sure nothing is between tile air conditioner
and the remote control that could block the signal,
::Ji::Make sure batteries are fl'esh and installed
correctly as indicated on tile remote control.
4
GEAppliances.com
Lights next to the touch pads on the air conditioner
control panel indicate the selected settings.
COOLMode
Use the COOL Inode with HIGH (F3), MED (F2) or
LOW(F1)tim for cooling. Use the INCREASEA /
DECREASE pads to set the desired temperature
between 60°F and 86°F in 1°F increments.
M_ electronic them/ostat is used to maintain tile room temperatm'e. Tile compressor will cycle on
and off to kee I) tile room at tile set level of comflwt. Set the them_ostat at a lower nttmber and the indoor
air will becolne coole_: Set tile fl/ern/ostnt at a higher nmnber and tile indoor air will become wam_e_:
NOTE:ff theairconditionerisoff andisthenturnedon
whilesetto COOL,it willtakeapproxl_nate/y3minutes forthecompressortostartandcoolingtobegin.
CoolingDescriptions
ForNormalCooling--Selectthe COOLmode and HIGH(F3)or MED(F2)fim with a middle set
temperature.
ForMaximumCooling--Select the COOL mode and HIGH(F3)firewith alower set temperature.
ForQuieter& NighttimeCooling--Selectthe
COOLmode and LOW(F/)fire with a middle set
temperature.
NOTE"/fyouswitchfroma COOLsettingtoOFFortoa fan settingwaitat least3minutesbeforeswitchingbacktoa
COOLsetting
FAN Mode
Use tile FANat HIGH(F3),MED(F2)or LOW(F/)to Since tim only settings do not provide cooling, provide air circulation and filtering without cooling, a temperatm'e setting will not be displayed.
Power Outage Recovery Feature
In tile case el a power outage or interruption, tile refit will automatically re-start in the settings last used after tile power is restored. Tile TlMERfeature
Vent Control
Tile vent control is located above tile control panels.
When set at CLOSE, only tile air inside tile room
will be circulated and conditioned, _Vhen set at
OPEN,some inside air is exhausted outside.
Air Direction--Side-to-Side
Tile side-to-side air direction is a(!i usted by moving tile lever to tile left or right.
will reset to tile original setting. You may need to set a new time if desired.
Toopen the vent, pull the lever toward you. Toclose it,push it hT.
Air Direction--Up and Down
Fingertip pressure on tile horizontal lou\'e_ a(!iusts tile air direction u I) or down.
(on some models)
5
Aboutthecontrolsonthe air conditionermmodelswith controlknobs.
Features and appearance will vary.
OFF
FAN OOL
HIGHQcIIGH
LOW' MED
FAN COOL
LOW
COOL
FAN OOL
LOW LOW
FAN COOL
OFF
MODECONTROLS
Yourmodel will have one of the above type controls.
3 98 2 7 2 5
[ 01[0][ 1''
TEMPCONTROLS
Yourmodel will have one of the above type controls.
Controls
Mode Controls
0
HIGHCOOL,MED COOLand LOWCOOL
provide cooling with (liflerent tan speeds.
FANsettings provide air circulation and
filtering without cooling.
NOTE:If youmovethemodecontrolfromacoolsettlbg
toOFFortoafansetting,waitat least3 mlbutes
beforeswitchlbgbacktoacoolsetting.
Cooling Descriptions ForNormal Cooling--Select HIGH COOLor MED
COOL with the temp control at midpoint.
For Maximum Cooling--Select HIGH COOL with the temp control at the highest number available on
VOIII" knob.
For Quieter & Nighttime Cooling--Select LOW COOL
with the temp control at midpoint,
TempControls
The temp control is used to maintain the
room temperature, The compressor will c)'cle on and off to kee I) the room at the same level
of comfort. _,_]_en wm turn the knob to a higher numbe_; the indoor air will become
cooler; Turn the knob to a lower number and the indoor air will become wmmer
Loading...
+ 14 hidden pages