GE ADQ12, ADV12, ADQ14, ADV14 Owner’s Manual & Installation Instructions

<![if ! IE]>

<![endif]>Air Conditioners

<![if ! IE]>

<![endif]>Room

www.GEAppliances.com

Safety Instructions . . . . . . . .2, 3

Operating Instructions

Control Knob Models . . . . . .6, 7

Touch Pad Models . . . . . . . . .4, 5

Care and Cleaning

Air Filter . . . . . . . . . . . . . . . . . .8

Grille and Case . . . . . . . . . . . . .8

Outdoor Coils . . . . . . . . . . . . . .8

Installation Instructions

Window Installation . . . . . . .9–15

Troubleshooting Tips . . . . . .16

Normal Operating Sounds . . .16

Consumer Support

Consumer Support . . . . . . . . .20

Product Registration . . . . .17, 18

Warranty . . . . . . . . . . . . . . . . .19

Write the model and serial numbers here:

Model # __________________________

Serial # __________________________

Find these numbers on a label on the side of the air conditioner.

Owner’s Manual and

Installation Instructions

ADQ12 ADQ14 ADV12 ADV14

49-7479 12-03 JR

<![if ! IE]>

<![endif]>Consumer Support Troubleshooting Tips Installation Instructions Operating Instructions Safety Instructions

IMPORTANT SAFETY INFORMATION.

READ ALL INSTRUCTIONS BEFORE USING.

WARNING!

For your safety, the information in this manual must be followed to minimize the risk of fire, electric shock or personal injury.

SAFETY PRECAUTIONS

Use this appliance only for its intended purpose as described in this Owner’s Manual.

This air conditioner must be properly installed in accordance with the Installation Instructions before it is used.

Never unplug your air conditioner by pulling on the power cord. Always grip plug firmly and pull straight out from the receptacle.

Repair or replace immediately all electric service cords that have become frayed or otherwise damaged. Do not use a cord that shows cracks or abrasion damage along its length or at either the plug or connector end.

Turn the mode control to OFF and unplug your air conditioner before making any repairs or cleaning.

NOTE: We strongly recommend that any servicing be performed by a qualified individual.

For your safety…do not store or use combustible materials, gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance.

All air conditioners contain refrigerants, which under federal law must be removed prior to product disposal. If you are getting rid of an old product with refrigerants, check with the company handling disposal about what to do.

HOW TO CONNECT ELECTRICITY

Do not, under any circumstances, cut or remove the third (ground) prong from the power cord. For personal safety, this appliance must be properly grounded.

The power cord of this appliance is equipped with a 3-prong (grounding) plug which mates with a standard 3-prong (grounding) wall outlet to minimize the possibility of electric shock hazard from this appliance.

Have the wall outlet and circuit checked by a qualified electrician to make sure the outlet is properly grounded.

Where a 2-prong wall outlet is encountered,

it is your personal responsibility and obligation to have it replaced with a properly grounded 3-prong wall outlet.

The air conditioner should always be plugged into its own individual electrical outlet which has a voltage rating that matches the rating plate.

This provides the best performance and also prevents overloading house wiring circuits which could cause a fire hazard from overheated wires.

See the Installation Instructions, Electrical Requirements section for specific electrical connection requirements.

2

www.GEAppliances.com

WARNING!

USE OF EXTENSION CORDS—115-Volt models only

Because of potential safety hazards under certain conditions, we strongly recommend against the use of an extension cord.

However, if you must use an extension cord, it is absolutely necessary that it be a UL-listed, 14 gauge, 3-wire grounding type appliance extension cord having a grounding type plug and outlet and that the electrical rating of the

cord be 15 amperes (minimum) and 125 volts.

CAUTION:

DO NOT use an extension cord with any of the 230/208 volt models.

USE OF ADAPTER PLUGS—115-Volt models only

Because of potential safety hazards under certain conditions, we strongly recommend against the use of an adapter plug.

However, if you must use an adapter, where local codes permit, a temporary connection may be made to a properly grounded 2-prong wall outlet by use of a UL-listed adapter available at most local hardware stores.

The larger slot in the adapter must be aligned with the larger slot in the wall outlet to provide proper polarity in the connection of the power cord.

When disconnecting the power cord from the adapter, always hold the adapter in place with one hand while pulling the power cord plug with the other hand. If this is not done, the adapter ground terminal is very likely to break with repeated use.

If the adapter ground terminal breaks, DO NOT USE the air conditioner until a proper ground has been established.

Attaching the adapter ground terminal to a wall outlet cover screw does not ground the appliance unless the cover screw is metal, and not insulated, and the wall outlet is grounded through the house wiring. You should have the circuit checked by a qualified electrician to make sure the outlet is properly grounded.

READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY.

SAVE THESE INSTRUCTIONS

3

<![if ! IE]>

<![endif]>Support Consumer Tips Troubleshooting Instructions Installation Instructions Operating Instructions Safety

<![if ! IE]>

<![endif]>Consumer Support Troubleshooting Tips Installation Instructions Operating Instructions Safety Instructions

About the controls on the air conditioner—models with touch pads.

Features and appearance will vary.

 

Cool on

Fan speed

 

on

Fan on

Air Conditioner Controls

Remote Control

Controls

ON/OFF Pad

Turns air conditioner on and off.

Display

Shows the set temperature or time remaining on timer.

MODE

Use to set the air conditioner to COOL or

FAN mode. NOTE: When setting the mode using the remote control, use the separate COOL and FAN pads.

Increase /Decrease Pads

Use to set temperature when in COOL mode.

FAN Pad

Use to set the fan speed to LOW , MED or

HIGH.

ENERGY SAVER (on some models)Controls the fan.

ON—The fan runs on low speed while the compressor cycles on and off and the set temperature will automatically increase by 2°F. This results in wider variations of room

temperature and humidity. Normally used when the room is unoccupied. NOTE: The fan will continue to run on low speed only after the compressor cycles off.

OFF—The fan runs all the time, while the compressor cycles on and off.

This feature must be set at OFF in order to use the fan settings (on the mode control).

TIMER Pad

ON—When the air conditioner is off, it can be set to automatically come on in 1 to 12 hours at its previous setting. Each touch will set the timer in hours.

OFF—When the air conditioner is on, it can be set to automatically turn off in 1 to 12 hours. Each touch will set the timer in hours.

To cancel the timer, press the TIMER pad until the display time disappears.

Remote Control Signal Receiver

Remote Control

To ensure proper operation, aim the remote control at the signal receiver on the air conditioner.

The remote control signal has a range of up to 24 feet.

Make sure nothing is between the air conditioner and the remote control that could block the signal.

Make sure batteries are fresh and installed correctly as indicated on the remote control.

4

GEAppliances.com

Lights next to the touch pads on the air conditioner control panel indicate the selected settings.

COOL Mode

Use the COOL mode with HIGH, MED or LOW fan for cooling. Use the INCREASE / DECREASE pads to set the desired temperature between 60°F and 90°F in 1°F increments.

An electronic thermostat is used to maintain the room temperature. The compressor will cycle on and off to keep the room at the set level of comfort. Set the thermostat at a lower number and the indoor air will become cooler. Set the thermostat at a higher number and the indoor air will become warmer.

NOTE: If the air conditioner is off and is then turned on while set to COOL, it will take approximately 3 minutes for the compressor to start and cooling to begin.

Cooling Descriptions

For Normal Cooling—Select the COOL mode and

HIGH or MED fan with a middle set temperature.

For Maximum Cooling—Select the COOL mode and HIGH fan with a lower set temperature.

For Quieter & Nighttime Cooling—Select the

COOL mode and LOW fan with a middle set temperature.

NOTE: If you switch from a COOL setting to OFF or to a fan setting, wait at least 3 minutes before switching back to a COOL setting.

FAN Mode

Use the FAN at HIGH, MED or LOW to provide air circulation and filtering without cooling. Since fan only settings do not provide cooling, a temperature setting will not be displayed.

Vent Control

The vent control is located above the control panels.

When set at CLOSE, only the air inside the room will be circulated and conditioned. When set at OPEN, some inside air is exhausted outside.

To open the vent, push the lever to the right.

To close it, push it to the left.

Air Direction—Side-to-Side

The side-to-side air direction is adjusted by moving the lever to the left or right.

Air Direction—Up and Down

Fingertip pressure on the horizontal louvers adjusts the air direction up or down.

5

<![if ! IE]>

<![endif]>Support Consumer Tips Troubleshooting Instructions Installation Instructions Operating Instructions Safety

<![if ! IE]>

<![endif]>Consumer Support Troubleshooting Tips Installation Instructions Operating Instructions Safety Instructions

About the controls on the air conditioner—models with control knobs.

Features and appearance will vary.

 

 

OFF

 

LOW

HIGH

 

FAN

FAN

 

LOW

HIGH

 

COOL

COOL

 

 

MED

 

 

COOL

TEMP CONTROL

MODE CONTROL

Controls

Temp Controls

The temp control is used to maintain the room temperature. The compressor will cycle on and off to keep the room at the same level of comfort. When you turn the knob to a higher number, the indoor air will become cooler. Turn the knob to a lower number and the indoor air will become warmer

Mode Controls

HIGH COOL, MED COOL and LOW COOL provide cooling with different fan speeds.

COOL provides cooling with a fixed fan speed.

LOW FAN, HIGH FAN or FAN provides air circulation and filtering without cooling.

NOTE: If you move the switch from a cool setting to OFF or to a fan setting, wait at least 3 minutes before switching back to a cool setting.

Cooling Descriptions

For Normal Cooling—Select HIGH COOL or

MED COOL with the temp control at midpoint.

For Maximum Cooling—Select HIGH COOL with the temp control at the highest number available on your knob.

For Quieter and Nighttime Cooling—Select

LOW COOL with the temp control at midpoint.

6

GEAppliances.com

Additional controls and important information.

Energy Saver (on some models)

Controls the fan.

ON—The fan runs on low speed while the compressor cycles on and off. This results in wider variations of room temperature and humidity. Normally used when the room is unoccupied.

NOTE: The fan will continue to run on low speed only after the compressor cycles off.

OFF—The fan runs all the time, while the compressor cycles on and off.

This feature must be set at OFF in order to use the fan settings (on the mode control).

Vent Control

The vent control is located above the control knobs.

When set at CLOSE, only the air inside the room will be circulated and conditioned. When set at OPEN, some inside air is exhausted outside.

To open the vent, push the lever to the right.

To close it, push it to the left.

Air Direction—Side-to-Side

The side-to-side air direction is adjusted by moving the lever to the left or right.

Air Direction—Up and Down

Fingertip pressure on the horizontal louvers adjusts the air direction up or down.

7

<![if ! IE]>

<![endif]>Support Consumer Tips Troubleshooting Instructions Installation Instructions Operating Instructions Safety

<![if ! IE]>

<![endif]>Consumer Support Troubleshooting Tips Installation Instructions Operating Instructions Safety Instructions

Care and cleaning of the air conditioner.

Grille and Case

Turn the air conditioner off and remove the plug

To clean, use water and a mild detergent. Do not

from the wall outlet before cleaning.

use bleach or abrasives.

Outdoor Coils

The coils on the outdoor side of the air conditioner should be checked regularly. If they are clogged with dirt or soot, they may be professionally steam cleaned, a service available through your GE service outlet.

Air Filter

The air filter behind the front grille should be checked and cleaned at least every 30 days or more often if necessary.

Clean the filter with warm, soapy water. Rinse and let the filter dry before replacing it.

NOTE: DO NOT rinse, or put the filter in an automatic dishwasher.

CAUTION: DO NOT operate the air conditioner without a filter because dirt and lint will clog it and reduce performance.

To remove:

1

Grasp the filter tab at the bottom center of the

grille and pull the filter down and out.

2

After cleaning, replace the filter by inserting

its top edge into the filter slot in the grille and

push up and in until it snaps into place.

8

Installation

Air Conditioner

Instructions

 

Questions? Call 800.GE.CARES (800.432.2737) or Visit our Website at: www.GEAppliances.com

BEFORE YOU BEGIN

Read these instructions completely and carefully.

IMPORTANT Save these

instructions for local inspector’s use.

IMPORTANT Observe all governing codes and ordinances.

Note to Installer – Be sure to leave these instructions with the Consumer.

Note to Consumer – Keep these instructions for future reference.

Skill level – Installation of this appliance requires basic mechanical skills.

Completion time – Approximately 1 hour

We recommend that two people install this product.

Proper installation is the responsibility of the installer.

Product failure due to improper installation is not covered under the Warranty.

CAUTION:

Do not, under any circumstances, cut or remove the third (ground) prong from the power cord.

Do not change the plug on the power cord of this air conditioner.

Aluminum house wiring may present special problems—consult a qualified electrician.

ELECTRICAL REQUIREMENTS

Some models require a 115/120-volt a.c., 60 Hz grounded outlet protected with a 15-amp time delay fuse or circuit breaker.

The 3-prong grounding plug minimizes the possibility of electric shock hazard. If the wall outlet you plan to use is only a 2-prong outlet, it is your responsibility to have it replaced with a properly grounded 3-prong wall outlet.

Some models require 230/208-volt a.c., protected with a time delay fuse or circuit breaker. These models should be installed on their own single branch circuit for best performance and to prevent overloading house or apartment wiring circuits, which could cause a possible fire hazard from overheating wires.

TOOLS YOU WILL NEED

Phillips head screwdriver

Scissors or knife

Flat-blade screwdriver

Pencil

Level

Ruler or tape measure

Adjustable wrench

Drill

9

Installation Instructions

PARTS INCLUDED

(Appearance may vary)

Foam top window gasket

Top mounting rail

Left

accordion panel

Left side mounting rail

Side mounting

rail seal strip Left support

Side mounting

rail seal strip

Window stool seal

Right

Right side

support

mounting rail

 

Right accordion panel

 

 

Type B (1)

 

 

 

 

 

 

 

Type A (14)

 

(on some

Type C (10)

Type D (2)

 

Type E (4)

 

Type F (2)

 

models)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

Installation Instructions

1WINDOW REQUIREMENTS

These instructions are for a standard double-hung window. You will need to modify them for other types of windows.

The air conditioner can be installed without the accordion panels if needed to fit in a narrow window. See the window opening dimensions.

All supporting parts must be secured to firm wood, masonry or metal.

The electrical outlet must be within reach of the power cord.

19″ min.

30″ to 42″ (With accordion panels)

2614″ min. (Without accordion panels)

2 STORM WINDOW REQUIREMENTS

A storm window frame will not allow the air conditioner to tilt toward the outside, and will keep it from draining properly.

To adjust for this, attach a piece of wood to the stool.

WOOD PIECES– WIDTH: 2

LENGTH: Long enough to fit inside the window frame.

THICKNESS: To determine the thickness, place a piece of wood on the stool to make it 1/2″ higher than the top of the storm window frame.

Attach securely with nails or screws provided by the installer.

1/2″ higher

 

than frame

Stool

 

Storm window frame

11

GE ADQ12, ADV12, ADQ14, ADV14 Owner’s Manual & Installation Instructions
Ground wire
Press in
Pull

Installation Instructions

3

A

B

C

D

REMOVE THE AIR CONDITIONER FROM THE CASE

Remove and discard the 2 shipping screws from the bottom rear of the case.

Grasp the filter tab at the bottom center of the grille and pull the filter down and out.

On models with control knobs, remove them by pulling them straight off their shafts.

Grasp the lower corners of the grille frame while pressing in on the case sides with your finger tips. Pull out to release and lift it up.

NOTE: Do not pull the bottom edge toward you more than 3 or you may damage the tabs of the grille.

3REMOVE THE AIR CONDITIONER FROM THE CASE (CONT.)

E On some models, you must also disconnect the control connectors before the grille frame can be removed. Press the locking tabs in while pulling on the other

side to release.

Press in

 

FRemove the locking screw and locking bracket from the lower frame.

GRemove the screw and washer securing the ground wire to the right side face of the unit.

Screw

Washer

HSlide the air conditioner from the case by gripping the base pan handle and pulling forward while bracing the case.

12

Loading...
+ 28 hidden pages