As an EnErgy Star® partner, GE has
determined that this product meets the
EnErgy Star® guidelines for energy efficiency.
Write the model and serial numbers
here:
Model # ________________________
Dehumidifiers
Serial # _________________________
Manual del propietario
La sección en español empieza en la página 25
You can find them on a label on the back
of the dehumidifier.
49-7637 01-10 GE
IMPORTANT SAFETY INFORMATION.
READ ALL INSTRUCTIONS BEFORE USING.
WARNING!
For your safety, the information in this manual must be followed to minimize the risk of fire, electric
shock or personal injury.
SAFETY PRECAUTIONS
When using this dehumidifier, always follow basic safety precautions, including the following:
n Use this appliance only for its intended
purpose as described in this Owner’s
Manual.
n This dehumidifier must be properly
installed and grounded as described
in this manual before it is used.
n Never operate this dehumidifier in an
area that is likely to accumulate standing
water.
If this condition develops, for your safety
disconnect the power supply before
stepping into the water.
n Never unplug your dehumidifier by pulling
on the power cord. Always grip plug firmly
and pull straight out from the receptacle.
n Replace immediately all electric service
cords that have become frayed or otherwise
damaged. A damaged power supply cord
must be replaced with a new power supply
cord obtained from the manufacturer and
not repaired. Do not use a cord that shows
cracks or abrasion damage along its length
or at either the plug or connector end.
n If the receptacle does not match the plug,
the receptacle must be changed out by a
qualified electrician.
n Turn the dehumidifier OFF and unplug it
before making any repairs or cleaning.
NOTE: We strongly recommend that any
servicing be performed by a qualified
individual.
n For your safety, do not store or use
combustible materials, gasoline or other
flammable vapors or liquids in the vicinity
of this or any other appliance.
n All dehumidifiers contain refrigerants,
which under federal law must be removed
prior to product disposal. If you are getting
rid of an old product with refrigerants,
check with the company handling disposal
about what to do.
n Do not use outdoors.
n This dehumidifier is intended for
indoor residential applications only.
This dehumidifier should not be used
for commercial or industrial applications.
■ These R410A Dehumidifier Systems require
contractors and technicians to use tools,
equipment and safety standards approved
for use with this refrigerant. DO NOT use
equipment certified for R22 refrigerant only.
HOW TO CONNECT ELECTRICITY
Do not, under any circumstances, cut or remove
the third (ground) prong from the power cord.
For personal safety, this appliance must be
properly grounded.
DO NOT use an adapter plug with this
appliance.
The power cord of this appliance is equipped
with a 3-prong (grounding) plug which mates
with a standard 3-prong (grounding) wall outlet
to minimize the possibility of electric
shock hazard from this appliance.
Have the wall outlet and circuit checked by a
2
qualified electrician to make sure the outlet is
properly grounded.
Where a 2-prong wall outlet is encountered,
it is your personal responsibility and obligation to
have it replaced with a properly grounded
3-prong wall outlet.
The dehumidifier should always be
plugged into its own individual electrical
outlet, which has a voltage rating matching
the rating plate.
This provides the best performance and also
prevents overloading house wiring circuits, which
could cause a fire hazard from overheated wires.
USE OF EXTENSION CORDS
GEAppliances.com
Because of potential safety hazards under
certain conditions, we strongly recommend
against the use of an extension cord.
However, if you must use an extension
cord, it is absolutely necessary that it be
a UL-listed, 14 gauge, 3-wire grounding
type appliance extension cord having
a grounding type plug and outlet and
that the electrical rating of the cord be
15 amperes (minimum) and 125 volts.
READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY.
SAVE THESE INSTRUCTIONS
What dehumidifier do you need?
Condition without dehumidification— Area (in square feet)
During warm and humid outdoor conditions 500 1000 1500 2000 2500 3000 3500
Moderately damp—Space feels damp
and has musty odor only in humid weather. ADKW30 ADKW30 ADKW30 ADKW30
Very damp—Space always feels damp and has musty
odor. Damp spots show on walls or floor. ADKW30 ADKW30 ADKW30 ADKW50
Wet—Space feels and smells wet. Walls or floor sweat,
or seepage is present. ADKW30 ADKW30 ADKW50 ADKW50
Table indicates recommended GE dehumidifier models, based on the area of the space to be dehumidified and the conditions that would exist in that space
when a dehumidifier is not in use. Dehumidification variables also include such other factors as climate, laundry equipment, number of family members,
number of doors and windows and degree and intensity of area activity.
3
About the controls on the dehumidifier.
Power on
indicator light
Continuous
operation on
indicator light
light indicates
bucket needs
to be emptied
Controls
Power Pad
Press to turn the dehumidifier on and off.
Continuous
Select for the dehumidifier to
operate continuously at its maximum
dehumidification settings until the bucket is
full. The Humidity Set Control Pads cannot be
used when Continuous is on.
Humidity Set Control Pads
The humidity level can be set within a range of
35% RH (Relative Humidity) to 80% RH (Relative
Humidity) in 5% increments.
For drier air, press the pad and set to
a lower percent value (%).
For damper air, press the pad and set
to a higher percent value (%).
When you first use the dehumidifier, set
the humidity control to 45% or 50%. Allow at
least 24 hours for the dehumidifier to achieve
the humidity level. If you still have damper air
than desired, set the humidity level to a lower
setting or select Continuous for maximum
dehumidification.
Bucket full
High fan
indicator light
Fan Speed Pads
Control the fan speed.
Press to select either High or Normal fan
speed.
Set the fan control to High for maximum
moisture removal. When the humidity
has been reduced and quiet operation is
preferred, set the fan control to Normal.
Display
Shows the set % humidity level while setting,
then shows the actual (+/– 5% accuracy)
room % humidity level.
Error CodesE1 – Humidity sensor error – Unplug the unit and
plug it back in. If error repeats, call for service.
E2 – Temperature sensor error – Unplug the unit
and plug it back in. If error repeats, call for
service.
P1 – Unit is defrosting, if any key is pressed during
defrost cycle P1 will be displayed for 3
seconds and disappear. Allow the unit time to
automatically defrost, The code will clear after
the units defrosts.
P2 – Water bucket is full – Empty the water bucket
and replace. See the Removing Collected
Water section.
Normal fan
indicator light
Other Features
BUCKET FULL Light
Glows when the bucket is ready to be emptied, or
when the bucket is removed or not replaced in the
proper position.
Auto Shut Off
The Water Level Control Switch shuts off the
dehumidifier when the bucket is full, or when the
4
bucket is removed or not replaced in the proper
position.
Auto Defrost
When frost builds up on the evaporator coils, the
compressor will cycle off and the fan will continue
to run until the frost disappears.
Power Outage
In the case of a power outage or interruption, the
unit will automatically re-start, in the settings last
used, after the power is restored.
Using the dehumidifier. GEAppliances.com
When first using the dehumidifier, operate the unit continuously 24 hours.
How the Dehumidifier Operates
Moist, humid air is drawn over a cold refrigerated
dehumidifying coil. Moisture in the air condenses on
this coil and drains into a bucket (or through
a hose and drain).
Dry, clean air is drawn through the condenser where
it is heated and discharged out the front grille into the
room.
It is normal for the surrounding air to become slightly
warmer as the dehumidifier operates.
This warming effect further reduces the relative
humidity of the surrounding air.
Choosing a Location
A dehumidifier operating in a basement will have little
or no effect in drying an adjacent enclosed storage
area, such as a closet, unless there is adequate
circulation of air in and out of the area.
n Do not use outdoors.
n This dehumidifier is intended for indoor residential
applications only. This dehumidifier should not be
used for commercial or industrial applications.
n Place the dehumidifier on a smooth, level floor
strong enough to support the unit with a full
bucket of water.
n Allow at least 12–18 inches of air space on all
sides of the unit for good air circulation.
n Place the dehumidifier in an area where the
temperature will not fall below 41°F (5°C). The coils
can become covered with frost at temperatures
below 41°F, which may reduce performance.
n Use the dehumidifier in cooking, laundry, bathing
and dishwashing areas that have excessive
moisture. NOTE: Place the dehumidifier away
from the clothes dryer.
n Use the dehumidifier to prevent moisture damage
anywhere books or valuables are stored.
n Use the dehumidifier in a basement to help
prevent moisture damage.
n The dehumidifier must be operated in an enclosed
area to be most effective.
n Close all doors, windows and other outside
openings to the room.
Automatic Defrost
When frost builds up on the evaporator coils, the
compressor will cycle off and the fan will continue to
run until the frost disappears.
When the coil is defrosted, the compressor or fan
(depending on model) will automatically restart and
dehumidifying will resume.
YES NO
12–18” min.12–18” min.
NOTE: The dehumidifier has rollers to aid placement,
but it should only be rolled on smooth, flat surfaces.
Do not attempt to roll the dehumidifier on carpet or
over objects.
5
Using the dehumidifier.
Always make sure the water bucket is locked into place on the dehumidifier.
Removing Collected Water
There are 2 ways to remove collected water:
Use the bucket. When the bucket is removed,
the unit will shut off. Empty and replace the
bucket.
NOTE: Support bucket with
both hands when emptying.
IMPORTANT: Do not use the drain tube if using
the bucket to collect water. When the drain tube
is connected, water will flow through it onto the
floor instead of into the bucket.
NOTES:
n Do not remove the bucket while the
dehumidifier is operating or if it has just
stopped operating. This might cause some
water to drip from the drain pan.
n The bucket must be in place and securely
seated for the dehumidifier to operate.
Use a hose. Water can be automatically
emptied into a floor drain by attaching the
unit’s drain tube with nozzle and a garden
water hose (not included).
1. Remove the bucket from the front of
the unit.
2. Remove the plug cover from the back of
the unit and store it in a safe location.
3. Insert the tube through the hole in the back
of the unit and securely press it onto the
connector on the front of the unit. Push the
tube around the front connector until the
nozzle is flush with the back of the unit.
4. Secure the nozzle to the back of the unit with
the two screws provided.
Back of unit
5. Cut (as needed) and thread a garden hose
(not supplied) onto the nozzle and lead it to
the floor drain.
Back of unit
6. Replace the bucket in the unit.
NOTE: The bucket must be in place and securely
seated for the dehumidifier to operate.
Insert tube through
hole in back of unit.
Back of unit
Firmly press the tube
onto the front connector.
Front of unit
Water Level
The dehumidifier will turn off automatically
when the bucket is full, or when the bucket is
6
removed or not replaced in the proper position.
The bucket must be replaced in the proper position
for the dehumidifier to work. The light will be on and
the dehumidifier will not run if the bucket is not in the
proper position.
Care and cleaning of the dehumidifier. GEAppliances.com
Turn the dehumidifier off and remove the plug from the wall outlet before cleaning.
Grille and Case
To clean the case:
Use water and a mild detergent. Do not use
bleach or abrasives.
If cabinet paint chips, you can touch it up with
a good grade enamel paint to prevent rust.
Water Bucket
To clean:
Every few weeks, clean the bucket to prevent growth
of mold, mildew and bacteria. Partially fill the bucket
with clean water and add a little mild detergent.
Swish it around in the bucket, empty and rinse.
NOTE: Do not use a dishwasher to clean the
water bucket.
To remove:
Remove the bucket and pour any water out.
To replace:
Slide the bucket into the dehumidifier.
NOTE: The bucket must be in place and securely
seated for the dehumidifier to operate.
To clean the front grille:
Use a vacuum attachment or brush.
Air Filter
The air filter behind the front grille should be checked
and cleaned at least every 30 days or
more often if necessary.
NOTE: DO NOT rinse or put the filter in an automatic
dishwasher.
To remove:
Grasp the filter edge and pull it out the side.
Clean the filter with warm, soapy water. Rinse and let
the filter dry before replacing it. Do not clean the filter
in a dishwasher.
CAUTION:DO NOT operate the
dehumidifier without a filter because dirt and lint
will clog it and reduce performance.
NOTE: Avoid using a dishwasher to clean the filter
7
Troubleshooting tips…
Save time and money! Review the chart below first and you may not need to call for service.
Problem Possible Causes What To Do
Dehumidifier The dehumidifier • Make sure the dehumidifier’s plug is pushed completely
does not start is unplugged. into the outlet.
The fuse is blown/circuit • Check the house fuse/circuit breaker box and replace
breaker is tripped. the fuse or reset the breaker.
Dehumidifier has reached its • The dehumidifier automatically turns off when this
preset level or bucket is full. occurs. Empty the bucket and replace properly.
Bucket is not in the • The bucket must be in place and securely seated for the
proper position. dehumidifier to operate.
Power failure. • There is a protective time delay (up to 3 minutes) to
prevent tripping of the compressor overload. For this
reason, the unit may not start normal dehumidifying
for 3 minutes after it is turned back on.
Dehumidifier does not Did not allow enough time • When first installed, allow at least 24 hours to maintain
dry the air as it should to remove the moisture. the desired dryness.
Airflow is restricted. • Make sure there are no curtains, blinds or furniture
blocking the front or back of the dehumidifier. See the
Choosing a Location section.
The Humidity Control may • For drier air, press the pad and set to a lower percent
not be set low enough. value (%) or press the Continuous pad for maximum
dehumidification.
Doors and windows may not • Check that all doors, windows and other openings
be closed tightly. are securely closed.
Clothes dryer may be • Install the dehumidifier away from the dryer.
blowing moisture-laden The dryer should be vented to the outside.
air into the room.
Room temperature • Moisture removal is best at higher room temperatures.
is too low. Lower room temperatures will reduce the moisture
removal rate. Models are designed to be operated at
temperatures above 41°F (5°C).
Dehumidifier runs Area to be dehumidified • Refer to the chart below to see if the capacity of your
too much is too large. dehumidifier is adequate.
Doors and windows are open. • Close all doors and windows to the outside.
Frost appears on Dehumidifier has been recently • This is normal. Frost will usually disappear
the coils turned on, or room temperature within 60 minutes. See the Automatic Defrost section.
is below 41°F (5°C).
Fan cannot be turned off The dehumidifier is in the • This is normal. Wait approximately 3 minutes and set the
and the Normal or High automatic fan mode. When fan to Normal or High as desired.
fan speed pads cannot the set room humidity level
be set is reached, the compressor
will turn off and the fan
will automatically continue
to run for approximately
3 minutes at a fixed setting.
Fan noise Air is moving through • This is normal.
the dehumidifier.
Water on floor Tube to connector or nozzle • Check the tube to connector and the nozzle to hose
or hose connection may be connections. See the Removing Collected Water section.
loose.
Intend to use the bucket to • Disconnect the drain nozzle if using the bucket to collect
collect water, but the drain nozzle water. See the Removing Collected Water section.
is attached.
E1, E2, P1 or P2 appear These are error codes. • See the About the controls on the dehumidifier section.
in the display
8
Troubleshooting tips…
Problem Possible Causes What To Do
Bucket Full LED light Drain hose not tight on fitting • Check drain hose connection.
flashing and alarm
sounds while drain hose Drain hose is kinked • Ensure the drain hose is pointed straight down to the floor
is connected and is not kinked in anyway.
Save time and money! Review the chart below first and you may not need to call for service.
9
10
GE Dehumidifier—One Year Limited Warranty.
Staple your receipt here.
Proof of the original purchase date is needed to make a warranty claim.
For The Period Of: We Will Replace:
One Year Replacement unit for any product which fails due to a defect in materials or workmanship.
From the date of the The replacement unit is warranted for the remainder of your product’s original one-year
original purchase warranty period. The replacement unit may either be a new unit or a refurbished unit.
In Order to Make a Warranty Claim During the First 30 Days from the Date of Original Purchase:
nProperly pack your unit. We recommend using
the original carton and packing materials.
nReturn the product to the retail location where
it was purchased.
nInclude in the package a copy of the sales receipt or other
evidence of date of original purchase. Also print your
name and address and a description of the defect.
In Order to Make a Warranty Claim During the Remainder of the One-Year Warranty:
nLocate your original sales receipt and make a note
of your model and serial number.
nCall GE at 1.866.907.1655 to initiate the product
replacement process.
nYou will be asked to provide your name, address,
date of purchase, model and serial number.
nGE will arrange for a carton to be sent to your home
to recover the product.
nYou must return the product (postage pre-paid by GE)
to GE’s recovery center before a replacement unit will be
provided. Please include a description of the defect.
nYou should receive your replacement product within
7 to 10 business days after your unit is received.
nIf you experience any problems or delays after initiating
the replacement process, please call 1.256.796.6610 for
assistance.
What Is Not Covered:
n Customer instruction. This owner’s manual provides
information regarding operating instructions and
user controls.
n Improper installation. If you have an installation problem,
or if the dehumidifier is of improper dehumidifying
capacity, contact your dealer or installer. You are
responsible for providing adequate electrical connecting
facilities.
n Failure of the product resulting from modifications to
the product or due to unreasonable use including failure
to provide reasonable and necessary maintenance.
n Replacement of house fuses or resetting of circuit
breakers.
n Failure due to corrosion on models not corrosion-
protected.
n Damage to the product caused by improper power
supply voltage, accident, fire, floods or acts of God.
n Incidental or consequential damage caused by possible
defects with this dehumidifier.
n Damage caused after delivery.
EXCLUSION OF IMPLIED WARRANTIES—Your sole and exclusive remedy is product replacement
as provided in this Limited Warranty. Any implied warranties, including the implied warranties of
merchantability or fitness for a particular purpose, are limited to one year or the shortest period
allowed by law.
This warranty is extended to the original purchaser and any succeeding owner for products purchased for
home use within the USA. Some states do not allow the exclusion or limitation of incidental or consequential
damages. This warranty gives you specific legal rights, and you may also have other rights which vary from
state to state. To know what your legal rights are, consult your local or state consumer affairs office or your
state’s Attorney General.
Exclusion of implied warranties: Except where prohibited or restricted by law, there are no warranties,
whether express, oral or statutory which extend beyond the description on the face hereof, including
specifically the implied warranties of merchantability or fitness for a particular purpose.
Warrantor: General Electric Company. Louisville, KY 40225
11
Loading...
+ 25 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.