GE AAP05, AAV05 Owner’s Manual & Installation Instructions

<![if ! IE]>

<![endif]>Air Conditioners

www.GEAppliances.com

Safety Instructions

Adapter Plugs . . . . . . . . . . . . . . . . . . . .3

Connect Electricity . . . . . . . . . . . . . . .2

Extension Cords . . . . . . . . . . . . . . . . .3

Safety Precautions . . . . . . . . . . . . . . . .2

Operating Instructions

Controls . . . . . . . . . . . . . . . . . . . . . . . .4

Care and Cleaning

Air Filter . . . . . . . . . . . . . . . . . . . . . . . .5

Grille and Case . . . . . . . . . . . . . . . . . . .5

Outdoor Coils . . . . . . . . . . . . . . . . . . .5

Installation Instructions . . . . .6–11

Troubleshooting Tips . . . . . . . . . .12

Normal Operating

Sounds . . . . . . . . . . . . . . . . . . . . . . . . .12

Consumer Support

Consumer Support . . . . .Back Cover

Product Registration . . . . . . . . .13, 14

Warranty . . . . . . . . . . . . . . . . . . . . . . .15

Write the model and serial numbers here:

Model # ________________________

Serial # ________________________

Find these numbers on a label in the air discharge area of the air conditioner.

Owner’s Manual &

Installation Instructions

AAP05

AAV05

49-7409 JR 12-00

<![if ! IE]>

<![endif]>Consumer Support Troubleshooting Tips Installation Instructions Operating Instructions Safety Instructions

IMPORTANT SAFETY INFORMATION.

READ ALL INSTRUCTIONS BEFORE USING.

WARNING!

For your safety, the information in this manual must be followed to minimize the risk of fire, electric shock or personal injury.

SAFETY PRECAUTIONS

Use this appliance only for its intended purpose as described in this Owner’s Manual.

This air conditioner must be properly installed in accordance with the Installation Instructions before it is used.

Never unplug your air conditioner by pulling on the power cord. Always grip plug firmly and pull straight out from the receptacle.

Repair or replace immediately all electric service cords that have become frayed or otherwise damaged. Do not use a cord that shows cracks or abrasion damage along its length or at either the plug or connector end.

Turn the mode control OFF and unplug your air conditioner before making any repairs or cleaning.

NOTE: We strongly recommend that any servicing be performed by a qualified individual.

For your safety…do not store or use combustible materials, gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance.

HOW TO CONNECT ELECTRICITY

Do not, under any circumstances, cut or remove the third (ground) prong from the power cord. For personal safety, this appliance must be properly grounded.

The power cord of this appliance is equipped with a 3-prong (grounding) plug which mates with a standard 3-prong (grounding) wall outlet to minimize the possibility of electric shock hazard from this appliance.

Have the wall outlet and circuit checked by a qualified electrician to make sure the outlet is properly grounded.

Where a 2-prong wall outlet is encountered,

it is your personal responsibility and obligation to have it replaced with a properly grounded 3-prong wall outlet.

The air conditioner should always be plugged into its own individual electrical outlet which has a voltage rating that matches the rating label.

This provides the best performance and also prevents overloading house wiring circuits which could cause a fire hazard from overheated wires.

See the Installation Instructions, Electrical Requirements section for specific electrical connection requirements.

2

www.GEAppliances.com

WARNING!

USE OF EXTENSION CORDS –115-Volt models only

Because of potential safety hazards under certain conditions, we strongly recommend against the use of an extension cord.

However, if you must use an extension cord, it is absolutely necessary that it be a UL-listed, 14 gauge, 3-wire grounding type appliance extension cord having a grounding type plug and outlet and that the electrical rating of the cord be 15 amperes (minimum) and 125 volts.

CAUTION:

DO NOT use an extension cord with any of the 230/208 volt models.

USE OF ADAPTER PLUGS –115-Volt models only

Because of potential safety hazards under certain conditions, we strongly recommend against the use of an adapter plug.

However, if you must use an adapter, where local codes permit, a temporary connection may be made to a properly grounded 2-prong wall outlet by use of a UL-listed adapter available at most local hardware stores.

The larger slot in the adapter must be aligned with the larger slot in the wall outlet to provide proper polarity in the connection of the power cord.

When disconnecting the power cord from the adapter, always hold the adapter in place with one hand while pulling the power cord plug with the other hand. If this is not done, the adapter ground terminal is very likely to break with repeated use.

If the adapter ground terminal breaks, DO NOT USE the air conditioner until a proper ground has been established.

Attaching the adapter ground terminal to a wall outlet cover screw does not ground the appliance unless the cover screw is metal, and not insulated, and the wall outlet is grounded through the house wiring. You should have the circuit checked by a qualified electrician to make sure the outlet is properly grounded.

READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY.

SAVE THESE INSTRUCTIONS

3

<![if ! IE]>

<![endif]>Support Consumer Tips Troubleshooting Instructions Installation Instructions Operating Instructions Safety

GE AAP05, AAV05 Owner’s Manual & Installation Instructions
<![if ! IE]>

<![endif]>Consumer Support Troubleshooting Tips Installation Instructions Operating Instructions Safety Instructions

About the controls on the air conditioner.

Features and appearance will vary.

LOW

LOW

5

6

FAN

COOL

4

7

 

OFF

MED

3

8

COOL

 

 

 

 

 

2

9

HIGH

HIGH

1

10

FAN

COOL

 

 

MODE CONTROL TEMP CONTROL

Controls

Mode Control

HIGH COOL, MED COOL and LOW COOL provide cooling with different fan speeds.

LOW FAN or HIGH FAN provides air circulation and filtering without cooling.

NOTE: If you move the switch from a cool setting to OFF or to a fan setting, wait at least 3 minutes before switching back to a cool setting.

Cooling Descriptions

For Normal Cooling—Select HIGH COOL or MED COOL with the temp control at midpoint.

For Maximum Cooling—Select HIGH COOL with the temp control at the highest number available.

For Quieter & Nighttime Cooling—Select LOW COOL with the temp control at midpoint.

Temp Control

The temp control is used to maintain the room temperature. The compressor will cycle on and off to keep the room at the same level of comfort. When you turn the knob to a higher number, the indoor air will become cooler. Turn the knob to a lower number and the indoor air will become warmer.

Air Direction

The side-to-side air direction is adjusted by moving the inner vertical louvers .

The up or straight ahead air direction is adjusted by fingertip pressure on the louvers.

4

Care and cleaning of the air conditioner.

www.GEAppliances.com

Grille and Case

 

Turn the air conditioner off and remove the plug

To clean, use water and a mild detergent. Do not

from the wall outlet before cleaning.

use bleach or abrasives.

Outdoor Coils

The coils on the outdoor side of the air conditioner should be checked regularly. If they are clogged with dirt or soot they may be professionally steam cleaned, a service available through your GE service outlet.

Air Filter

The air filter behind the front grille should be checked and cleaned at least every 30 days or more often if necessary.

Clean the filter with warm, soapy water. Rinse and let the filter dry before replacing it.

CAUTION: DO NOT operate the air conditioner without a filter because dirt and lint will clog it and reduce performance.

To remove:

Grab the tab on the filter and pull it to the right.