g
GE Industrial Systems
Digital Energy
Uninterruptible Power Supply
350-500-700-1000 VA
™
ML Series
Manufactured by:
GE Digital Energy
General Electric Company Telephone +41 (0)91 / 850 51 51
CH – 6595 Riazzino (Locarno) Fax +41 (0)91 / 850 51 44
Switzerland Website www.gedigitalenergy.com
ML Series UPS
Technology for the Digital World.
ver 1.1 - GB
g
GE Digital Energy™ ML Serie
GB
USER MANUAL
Digital Energy™ ML Series
Uninterruptible Power Supply
Uninterruptible Power Supply
Uninterruptible Power SupplyUninterruptible Power Supply
350
350----500
500----700
700----1000 VA
350350
500500
Please read these instructions carefully before installation and start-up of the Digital
Energy™ ML Series UPS. Keep this manual in a safe place for future reference.
CONTENTS
1 INTRODUCTION ........................................................................................... 2
1.1 Introduction
1.2 Safety Rules
1.3 Transport / Storage
2 INSTALLATION ............................................................................................. 2
2.1 Installation Rules
2.2 Installation Procedure
3 OPERATION.................................................................................................. 4
3.1 Start-up
3.1.1 Start-up, mains available
3.1.2 Start-up, mains not available (‘battery start’)
3.2 Use: Normal Operation
3.2.1 Normal operating conditions
3.2.2 Self test
3.2.3 Auto-off (no-load shutdown)
3.2.4 Switching off
3.3 Use: Status and Alarm Indications
3.3.1 Charger on
3.3.2 Normal operation
3.3.3 On battery
3.3.4 Battery low
3.3.5 Replace battery
3.3.6 Overload
3.3.7 Self test
4 COMMUNICATION........................................................................................ 6
5 MAINTENANCE............................................................................................. 7
5.1 General
5.2 Fuses
5.3 Batteries
5.3.1 General
5.3.2 Battery replacement
6 TROUBLESHOOTING .................................................................................. 8
7 SPECIFICATIONS......................................................................................... 9
© General Electric. All rights reserved; reproduction without permission prohibited. This manual may be subject to change; no
liability can be accepted for any error or omission.
700700
1000 VA
1000 VA1000 VA
OPM_MLE_LTE_350_1K0_1GB_V011 1 DE ML Series: user manual 1.1 (GB)
g
1 - Introduction
GE Digital Energy™ ML Serie
1.1 Introduction
The GE (General Electric) Digital Energy™ ML Series UPS, an uninterruptible power supply, protects
your equipment from all forms of power interference, including complete power failures.
1.2 Safety Rules
• CAUTION: RISK OF ELECTRICAL SHOCK. The UPS contains batteries. The
appliance outlets may be electrically live, even when the UPS is disconnected from the
mains.
• The UPS contains potentially hazardous voltages. Do not open the UPS, there are no
user serviceable parts inside.
• Apart from battery replacement on the ML 350/500/700 models, all maintenance and
service work should be performed by qualified service personnel.
• Always isolate the UPS from the mains during battery replacement.
1.3 Transport / Storage
• No liability can be accepted for any transport damage when the equipment is shipped in non-
original packaging.
• Before storing, charge the batteries for at least 24 hours.
• Store the UPS in a dry location, storage temperature must be within -20 +45 °C. If the unit is
stored for a period exceeding 3 months, optimal battery lifetime is obtained if the storage
temperature does not exceed 25°C. Be sure that the UPS is switched off, and that no cable is
connected to the interface port.
• If the unit is stored for a period exceeding 3 months, the batteries must be recharged
periodically. Connect the unit to a wall outlet for a period of approx. 48 hours, minimum every 3
months.
2 - Installation
The shipping box contains a Digital Energy™ ML Series UPS, a power cord, a computer interface
cable, a CD ROM and this manual. After unpacking, inspect the UPS for damage. If you find any damage
please immediately notify the carrier and place of purchase.
IMPORTANT:
Before making any connection and switching on the Digital Energy™ ML Series UPS, please check the
following conditions:
• your mains supply is 220 - 240 Volts and 50 Hz, and
• the total power demand of the connected equipment does not exceed the rated output power of
the UPS (indicated on the rear panel).
2.1 Installation Rules
• The UPS is intended to be used in normal domestic and office situations.
• Protect the UPS, according to the wiring rules, with a 16A D-type fuse.
• The UPS must be powered from a single phase grounded wall outlet. Do not use extension
cords.
• Avoid locations that are excessively humid, near water, near heat sources or in direct sunlight.
• The ambient temperature should not exceed 40°C. Optimal battery lifetime is obtained if the
ambient temperature does not exceed 30°C.
• It is important that ventilation air can move freely around and through the unit. Do not block the
air vents.
• Do not plug appliances such as electric heaters, toasters and vacuum cleaners into the UPS.
The UPS output can be used only for electronic loads such as computers and
telecommunications equipment.
• Be careful when connecting laser printers: be sure that the demanded power does not exceed
the capacity of the UPS.
OPM_MLE_LTE_350_1K0_1GB_V011 2 DE ML Series: user manual 1.1 (GB)