GE Energy
Technical Specifications
Masoneilan* Valves
10000 Series Control Valves
Double Ported Globe Valves
07/2012
Table of Contents
Numbering System ...........................................................................................2
General Data .......................................................................................................2
Temperature Range / Seat Leakage ..........................................................3
Ratings /Connections .......................................................................................4
Flow Coefficient – Rated C
v ...................................................................................................................
Numbering System
1st
8
2nd 5th4th3rd
1st
1
and FL versus Travel .............................................................................. 5-6
C
V
Materials of Construction ...................................................................... 7-12
Valve Dimensions ....................................................................................13-14
Valve Weights ..................................................................................................15
4
Actuator Dimensions and Weights .................................................16-17
2nd
0
1
Actuator Type
87 Spring Diaphragm
Air to Close
88 Spring Diaphragm
Air to Open
Body
Series
10
General Data
n Flow Direction
All trim: Flow through both ports
n Body
Type: Double seat globe
n Body Bonnet & Lower Flange
Type: Bolted
n Bonnet & Lower Flange
Materials: Carbon steel
Stainless steel
Chrome-molybdenum steel
Plug Type
1. Double Seat
n
Plug type: Double seat
V-port or contoured
Seat ring: Threaded
Guide: Heavy top and bottom guiding
Capacity: Full area
Reduced capacity (0.4 factor)
Cv ratio: 50:1
Flow characteristics: Equal percentage
Quick opening
Linear
n Actuator
Type: Spring diaphragm
Handwheel: Optional
Trim
Control
Characteristics
3. Equal % (V-Port)
6. Quick Opening
7. Linear
Seat Type
2. Down Seating
2 | GE Energy
Temperature Range / Seat Leakage
Body &
Valve Size
(1)
inch mm
0.75
20 to
to 16
1) Maximum temperature shown is with PTFE packing and LE Packing. Extended max. operating temperature of 800°F
(427
2) LE Packing for low emissions applications is limited to maximum pressure and temperature as shown in chart below.
400
°
C) allowable with Graphite packing.
Body
Rating
ASME Class
150 to 600
(PN 20 to
100)
Bonnet
Material
Carbon
Steel
Stainless
Steel
Chrome-
Moly
NACE
-4°F +450°F
(-20°C) (+232°C) (-20°C) (+427°C)
-20°F +450°F
(-29°C) (+232°C) (-100°C) (+427°C)
32°F +450°F
(0°C) (+232°C) (0°C) (+427°C)
-4°F +450°F
(-20°C) (+232°C)
Temperature Range
Standard
Bonnet
Extension
Bonnet
min. max. min. max.
(1)
-4°F +800°F
(1)
-148°F +800°F
(1)
32°F +800°F
Seat Leakage
IEC 60534-4 and
ANSI/FCI 70.2
Class
II
Pressure and Temperature Rating of LE Packing
1600
(112)
1400
(98)
1200
(84)
1000
(70)
800
(56)
600
(42)
400
Fluid Pressure PSI (Bar)
(28)
200
(14)
0
0 50 100 150 200 250 300 350 400 450 500
(10) (38) (66) (93) (121) (149) (177) (204) (232) (260)
Fluid Temperature °F (°C)
10000 Series Double Ported Globe Valves | 3
Ratings / Connections
n RF Flanged ∆ RT Joint n Butt Weld m Socket Weld l Threaded
Valve Size
mm
Inch
.75 20
1 25
1.5 40
2 50
3 80
4 100
6 150
8 200
10 250
12 300
14 350
16 400
1) Consult factory for availability of additional sizes and end connections.
150
n
∆ l m
n
∆ l m
n
∆ l m
n
∆ l m
n
∆
n
∆
n
∆
n
∆
n
∆
n
∆
n
∆
n
∆
Flow Coefficient – Rated C
Nominal Size
Inch
mm
Inch
Travel
mm
Full Capacity C
ASME Class
300
n
∆ l m
n
∆ l m
n
∆ l m
n
∆ l m
n
∆
n
∆
n
∆
n
∆
n
∆
n
∆
n
∆
n
∆
(1)
v
v
Reduced Capacity C
.75 20 0.5 12.7 8 1 25 0.5 12.7 12 8
1.5 40 0.8 20.3 28 11
2 50 0.8 20.3 48 19
3 80 1.5 38.1 110 44
4 100 1.5 38.1 195 78
6 150 2 50.8 450 180
8 200 2.5 63.5 750 300
10 250 2.5 63.5 1160 460
12 300 3.5 88.9 1620 650
(3)
350 4 101.6 2000
14
16 400 4 101.6 2560
(4)
-
(4)
-
600
n
∆ l m
n
∆ l m
n
∆ l m
n
∆ l m
n
∆
n
∆
n
∆
n
∆
n
∆
n
∆
n
∆
n
∆
(2)
v
1) Rated Cv for Quick Opening trim is 1.3 times values shown.
2) 1" size reduced capacity trim is same as .75" size full area trim.
3) Consult factory for details on 14" size.
4) 14" and 16" sizes are only available with Equal Percentage trim.
4 | GE Energy
CV and FL versus Travel
Contoured Trim
ASME Class 150 to 600
Flow Characteristic: LINEAR
Percent of Travel
Orifice
inch
Full Area
Reduced Area
Travel
inch
F
L
Valve
Size
Diameter
inch
0.75 .88/.80 0.5 .8 1.6 2.4 3.2 4.0 4.8 5.6 6.4 7.2 8
1.06/.98 0.5 1.2 2.4 3.6 4.8 6 7.2 8.4 9.6 10.8 12
1.06/.98 0.8 1.1 2.2 3.3 4.4 5.5 6.6 7.7 8.8 9.9 11
2.00/1.90 0.8 4.8 9.6 14.4 19.2 24 28.8 33.6 38.4 43.2 48
2.62/2.53 1.5 11 22 33 44 55 66 77 88 99 110
3.50/3.40 1.5 19.5 39 58.5 78 97.5 117 136 156 175 195
5.25/5.15 2 45 90 135 180 225 270 315 360 405 450
7.00/6.87 2.5 75 150 225 300 375 450 525 600 675 750
8.75/8.62 2.5 116 232 348 464 580 696 812 928 1044 1160
10.50/10.34 3.5 162 324 486 648 810 972 1134 1296 1458 1620
.88/.80 0.5 .8 1.6 2.4 3.2 4.0 4.8 5.6 6.4 7.2 8
1
1.5
1.5/1.42 0.8 2.8 5.6 8.4 11.2 14 16.8 19.6 22.4 25.2 28
1.43/1.35 0.8 1.9 3.8 5.7 7.6 9.5 11.4 13.3 15.2 17.1 19
2
1.87/1.78 1.5 4.4 8.8 13.2 17.6 22 26.4 30.8 35.2 39.6 44
3
2.37/2.28 1.5 7.8 15.6 23.4 31.2 39 46.8 54.6 62.4 70.2 78
4
3.50/3.40 2 18 36 54 72 90 108 126 144 162 180
6
4.62/4.53 2.5 30 60 90 120 150 180 210 240 270 300
8
5.25/5.15 2.5 46 92 138 184 230 276 322 368 414 460
10
6.37/6.25 3.5 65 130 195 260 325 390 455 520 585 650
12
10 20 30 40 50 60 70 80 90 100
.63 .64 .65 .70 .77 .85 .90 .90 .89 .88
.63 .64 .65 .70 .75 .80 .82 .82 .81 .80
Rated C
V
10000 Series Double Ported Globe Valves | 5
CV and FL versus Travel
V-Port Trim
ASME Class 150 to 600
Flow Characteristic: EQUAL PERCENTAGE
Percent of Travel
F
L
Valve
Size
Orifice
Diameter
inch
0.75 .88/.80 0.5 .24 .48 .64 .88 1.2 1.8 2.3 3.6 5.2 8
.88/.80 0.5 .24 .48 .64 .88 1.2 1.8 2.3 3.6 5.2 8
1
1.06/.98 0.5 .36 .72 .96 1.3 1.8 2.6 3.5 5.4 7.8 12
1.5/1.42 0.8 .84 1.7 2.2 3.1 4.2 6.2 8.1 12.6 18.2 28
2.00/1.90 0.8 1.4 2.8 3.8 5.3 7.2 10.5 13.9 21.6 31.2 48
2.62/2.53 1.5 3.3 6.6 8.8 12.1 16.5 24.2 31.9 49.5 71.5 110
3.50/3.40 1.5 5.8 11.7 15.6 21.4 29.2 42.9 56.5 87.7 126 195
5.25/5.15 2 14 27 36 50 68 99 130 202 292 450
7.00/6.87 2.5 23 45 60 83 112 165 217 337 487 750
8.75/8.62 2.5 35 70 93 127 174 255 336 522 754 1160
10.50/10.34 3.5 49 97 130 178 243 356 469 729 1053 1620
14 12.2/12.1 4 60 120 160 220 300 440 580 900 1300 2000
16 14.00/13.86 4 77 153 207 281 384 563 742 1152 1664 2560
1.06/.98 0.8 .33 .66 .88 1.2 1.6 2.4 3.2 4.9 7.1 11
1.5
1.43/1.35 0.8 0.6 1.1 1.5 2 2.8 4.2 5.5 8.5 12.3 19
2
1.87/1.78 1.5 1.3 2.6 3.5 4.8 6.6 9.7 12.8 19.8 28.6 44
3
2.37/2.28 1.5 2.3 4.7 6.2 8.6 11.7 17.2 22.6 35.1 50.7 78
4
3.50/3.40 2 5 11 14 20 27 40 52 81 117 180
6
4.62/4.53 2.5 9 18 24 33 45 66 87 135 195 300
8
5.25/5.15 2.5 14 28 37 51 69 101 133 207 299 460
10
6.37/6.25 3.5 20 39 52 72 98 143 189 293 423 650
12
Reduced Area
inch
Full Area
Travel
inch
10 20 30 40 50 60 70 80 90 100
.96 .96 .96 .96 .95 .94 .94 .93 .91 .90
.96 .96 .95 .94 .93 .92 .91 .90 .89 .88
Rated C
V
6 | GE Energy