To prevent fire and electric shock, do not expose this product to rain or moisture.
The lightning flash with the arrowhead symbol,
within an equilateral triangle, is intended to alert
the user to the presence of uninsulated
"dangerous voltage" within the products enclosure
that maybe of sufficient magnitude to constitute a
risk of electric shock to persons.
CAUTION!
To prevent electric shock, do not remove cover.
No user serviceable components inside. Refer
servicing to qualified service personnel.
!
The exclamation point, within an equilateral
triangle, is intended to alert the user to the
presence of important operating and maintenance
(servicing) instructions in the literature
accompanying the product.
!
CAUTION! Lithium Battery
Danger of explosion if battery is
incorrectly replaced. Replace only
with the same or equivalent type
This equipment generates, uses and can radiate radio frequency energy, and if not installed and used
in accordance with the instructions in this manual, may cause interference to radio communications. It
has been tested and found to comply with the limits for a Class A computing device pursuant to subpart
J of part 15 of FCC rules which are designed to provide reasonable protection against such
interference when operated in a commercial environment. This equipment has also been tested and
found to comply with the requirements for a CE Class A device and TUV safety standards.
recommended by the
manufacturer.
Electrostatic-Sensitive Device!
Use proper CMOS and MOSFET handing precautions, including approved
grounded wrists straps, etc., to avoid damage to this unit or its internal
components, from electric discharge.
WARNING!
This product contains a recyclable lithium battery.
It may be illegal to dispose of this battery
improperly under local, state, or federal laws.
Check with your local waste management officials
for disposal and recycling options.
CAUTION!
ATTENTION
Operation of this equipment in a residential area may cause interference, in which case the user is
required to take all measures that are necessary, at the user's expense, to correct the interference.
0150-0193C 2 Calibur DVMRe Triplex
IMPORTANT INFORMATION
Software and/or firmware is furnished to the purchaser under a license for use on a single system.
Software and/or firmware included with this equipment are the sole proprietary property of, confidential
to, and copyrighted by GE-Interlogix Kalatel Division, Corvallis, Oregon, USA. The software/firmware
are not to be copied or disclosed in any manner without the express written consent of GE-Interlogix.
All information and specifications furnished by GE-Interlogix are believed to be accurate and reliable.
No responsibility is assumed by GE-Interlogix for neither its use nor any infringements of rights of third
parties that may result from its use. No license is granted by implication or otherwise under any patent
or patent rights of GE-Interlogix.
The CALIBUR™ brand name and product model numbers are the property of GE-Interlogix.
COPYRIGHT, 2002: The contents of this manual may not be copied or reproduced in any manner or
form without the prior written consent of GE-Interlogix.
0150-0193C 3 Calibur DVMRe Triplex
Contents
1 DVMR
1.1 Products Featured In This Manual...................................................................................6
10 Warranty and Service..........................................................................................75
10.1 Factory Service ...............................................................................................................75
10.2 Warranty and Return Information..................................................................................76
0150-0193C 5 Calibur DVMRe Triplex
e
1 DVMR
Triplex Overview
1.1 Products Featured In This Manual
DVMRe -4CT: Digital Video Multiplexer Recorder, Four-Channel, Color, Triplex.
DVMRe -10CT: Digital Video Multiplexer Recorder, Ten-Channel, Color, Triplex.
DVMRe -16CT: Digital Video Multiplexer Recorder, Sixteen-Channel, Color, Triplex.
Key To Model Numbers
1. DVMRe: Digital Video Multiplexer Recorder, Ethernet capable.
DVMRe 16 C T
2. 4, 10, or 16: Maximum number of camera inputs.
3. C: Color.
4. T: Triplex.
1 2 3 4
1.2 Product Description
The DVMRe Triplex is a video multiplexer capable of recording from multiple cameras to an internal
hard drive while simultaneously providing playback. Unlike outdated time-lapse VCRs, the DVMRe
Triplex records high-resolution pictures. Digital recording improves playback quality over VCRs, and
eliminates the hassle of cleaning heads, changing tapes or servicing motors. The unit can also be
programmed to record continuously by overwriting the oldest recorded data. Depending on the setup,
the DVMRe Triplex can store from a few hours to more than 3 years of color images.
Programmable search features eliminate time consuming Fast Forwarding or Rewinding of tapes,
searching for critical data. Search for recorded images or events by alarm, time, date, motion, video
loss, camera number and ASCII cash register or ATM text.
Caution! This products primary purpose is to furnish video multiplexing and recording.
Although the unit has alarm handling and motion detection functions, they are considered
secondary features. This unit should not be the only alarm device on site.
Features
• Multiplexer functionality with built-in digital recording.
• Triplex simultaneous recording, playback, and live multiscreen viewing.
• Remote programming and control through the RS232, RS485 and Ethernet ports.
• View live or recorded images remotely using WaveReader software.
• Dual multiscreen monitor displays.
• Video motion detection (intrusion and activity).
• Motion search.
• Record speed selectable per camera.
• Displays include full screen, sequenced, picture-in-picture, and multiscreens.
• Alarm Handling with History Log. Pre- and post alarm recording, selectable per camera.
• Archive onto Calibur DVSe Disk Array, or RAID, DAT, AIT, or CD-Rs.
• PTZ control via ethernet or POTS, using CBR-KB3/J or KTD-405 keypad.
• Covert camera recording (recording without display).
• Daylight savings time change function.
• Alarm Notification via email and/or TCP/IP dialout notification.
0150-0193C 6 Calibur DVMRe Triplex
1.3 Passwords
Passwords are provided to limit access to menus and certain functions. Two levels of password
security are provided:
• Operator: Limited menu access, only Operator and System View menus are available.
• Installer: Complete menu access.
As a security measure, it is recommended that the Operator and Installer passwords be changed after
installation is complete (see section 3.20). Store the passwords in the administrator’s secure files.
Default Passwords
Four-Channel Units
Password
Type
Operator
Installer
Factory
Defaults
Language
Ethernet
Access
Reset
Access
Level Function
Operator
Installer
Installer
Installer
Installer
Provides access to the Operator
and SystemView menus.
Provides access to all on-screen
Resets the multiplexer to the
factory defaults.
Provides access to the On-screen
Language menu.
Deactivates the ethernet
password, so that the unit may be
accessed by any PC equipped with
Ten and Sixteen-Channel Units
Password
Type
Access
Level Function
menus.
WaveReader.
Changeable
by user?
Yes
Yes
No
No
No
Changeable
by user?
Default
Password
Press ‘ENTER’
4 Times
3 4 4 4
4 1 1 1
1 4 1 4
1 1 1 1
Default
Password
Operator
Installer
Factory
Defaults
Language
Ethernet
Access
Reset
0150-0193C 7 Calibur DVMRe Triplex
Operator
Installer
Installer
Installer
Installer
Provides access to the Operator
and SystemView menus.
Provides access to all on-screen
menus.
Resets the multiplexer to the
factory defaults.
Provides access to the On-screen
Language menu.
Deactivates the ethernet
password, so that the unit may be
accessed by any PC equipped with
WaveReader.
Yes
Yes
No
No
No
Press ‘ENTER’
4 Times
3 4 7 7
8 1 1 1
5 4 1 5
1 1 1 1
1.4 Unpacking
Check the package and contents for visible damage. If any components are damaged or missing, do
not attempt to use the unit, contact the supplier immediately. If the unit must be returned, it must be
shipped in the original packing box.
Package Contents
• The DVMRe Triplex unit.
• The Alarm Interface Circuit Board (P/N 0090-0077).
• Power Cord ( NTSC P/N 4310-0002) (PAL P/N 4310-0001)
1.5 Installation Environment
Power: Ensure that the installation site’s AC power is stable and within the rated voltage of the 12
Volt DC power supply. If the site’s AC power is likely to have spikes or power dips, use power line
conditioning or an Uninterruptable Power Supply (UPS).
Ventilation: Ensure that the location planned for the installation of the unit is well ventilated. Take
note of the locations of the cooling vents in the unit’s enclosure, and ensure that they are not
obstructed.
Temperature: Consider the unit’s operating temperature (0 to 40 °C) and non-condensing humidity
specifications (10% to 80%) before choosing an installation location. Extremes of heat or cold beyond
the specified operating temperature limits may cause the unit to fail. Do not install the unit on top of
other hot equipment. Leave space between rack mounted units.
Moisture: Do not expose the unit to rain or moisture. Moisture can damage the internal components.
Do not install the unit near sources of water.
Chassis: Other equipment may be placed on top of the unit if it weighs less than 35 pounds (16
kilograms).
1.6 Associated Equipment
Associated equipment in a typical security system could contain the following items:
• Two monitors
• A Keyboard (KB3 or KTD405).
• Video cameras: Composite video, 1 volt peak-to-peak.
• Alarm input devices: Pressure sensors, motion detectors, etc.
• Alarm output devices: Buzzers, Sirens, Flashing Lights, etc.
• A PC connected via ethernet cable.
0150-0193C 8 Calibur DVMRe Triplex
• An external archive device, such as a DVSe, RAID, CD-R, DAT, or AIT drive.
B
B
RS-485/1
ETHERNET
RS-485/2
RS-232/2
2345678
9
121314
For instructions regarding the connection of the associated security equipment in your system, please
consult the instruction manual of the associated equipment.
1.7 The Back Panel
1
AUX
12345678910111213141516
SVHS
SCSI
12V DC
RS-232/1
10/100
1011
1. Camera Inputs: BNC connector, looping. Auto Terminating.
2. Composite Monitor-A Output: Composite video output with BNC style connector.
3. Y/C Monitor-A Output: Y/C video output with 4-pin mini-DIN style connector.
4. Alarm I/O: For connecting alarm inputs, and alarm output relays.
5. Power Input: For connecting the power supply.
6. Aux Port: For connecting the Accessory PCB for Audio inputs and outputs.
7. RS485 Port 1 Connector: For connecting to keyboard and other RS485 devices.
8. 10/100 Ethernet Port: For connecting to remote PC via ethernet network.
9. Composite Monitor-B Output: Composite video output with BNC style connector.
10. Y/C Monitor-B Output: Y/C video output with 4-pin mini-DIN style connector.
11. SCSI Port: For connecting SCSI compatible archive devices.
12. RS232 Port 1: For modem connection and external control of the unit.
13. RS485 Port 2 Connector: For connecting to keyboard and other RS485 devices.
14. RS232 Port 2: For Event Generation and ASCII Text insertion.
Camera Inputs
There are two BNC jacks for each camera. Either
jack can receive a camera signal. The signal is
looped (directly connected to the other jack), making
the camera signal available to other equipment.
Cable: 75-Ohm Coaxial
Connectors: BNC
Auto Terminating: Yes
The camera input connectors are Auto Terminating.
Passive Looping: Yes
This means that the input signal will automatically be terminated with 75-Ohms unless a 2nd cable is
connected to the 2nd BNC connector of the same camera input. Make sure there is 75-Ohm
termination at the end of the video line if the signal is looped through the DVMRe Triplex.
Time base correction is performed during digital capture. As a result, cameras do not require
synchronization.
See section 3.14 for information about disabling unused camera jacks in the menu system.
0150-0193C 9 Calibur DVMRe Triplex
Composite Monitor Output
A
7
G
N
D
When connecting directly from the DVMRe Triplex to
the monitor, select the 75-Ohm impedance setting on
the monitor.
If an additional device is connected to the monitor’s looping output, set the termination of the additional
device as 75-Ohm, and set the termination of the monitor as Hi-Z (High Impedance).
Cable: 75-Ohm Coaxial
Connectors: BNC
Y/C Monitor Output
Y/C video output has a 4-pin mini-DIN style
connector. This style of connection is also referred to
as SVHS and S-Video.
Cable: 75-Ohm Coaxial
Connectors: BNC
Alarm I/O Port
The back panel of the unit is equipped with an Alarm
Port (DB-25 style connector).
Do not attempt to wire directly to the DB-25
connector on the back panel.
DB-25 Connector on Back Panel
Connect the Alarm PCB (supplied with the unit) to the Alarm Port. Wire all alarm inputs to the Alarm
PCB per the pin out specifications shown below.
Active alarm inputs vary by DVMRe model. 4 channel units (4CT) have 4 active alarm inputs. 10
channel units (10CT) have 10 active alarm inputs.
Alarm Input
An alarm condition can be activated by devices such as pressure pads, passive infrared detectors,
door switches, or other similar devices.
0150-0193C 10 Calibur DVMRe Triplex
See section 3.11 for information about configuring the contacts as Normally Open or Normally Closed
pins 18
-
20
Normally Closed
DVMRe Triplex DB25 Connector
(Closes During Alarm)
Alarm Input No. 16
Ground
Output Relay No. 2
Output Relay No. 1
in the menu system.
Normally Open, Zero Potential Relay Contact: Configure in menu as Normally Open.
Normally Closed, Zero Potential Relay Contact: Configure in menu as Normally Closed
TTL Active High: Configure in menu as Normally Closed.
TTL Active Low: Configure in menu as Normally Open.
Open Collector Active On: Configure in menu as Normally Open.
Open Collector Active Off: Configure in menu as Normally Closed.
Alarm Input No. 1
Alarm Input No. 2 - 15
pin 1
pins 2-15
pin 16
Refer to each alarm device's manual for specific wiring details.
Typical wiring for Alarm #1 as Normally
Open and Alarm #16 as Normally Closed.
Normally Open and Normally Closed Connections
Alarm Relay Output
The alarm relay output is activated when an alarm condition
exists. The alarm output is only active for the duration of the
alarm.
Output: Zero potential relay contacts,
programmable in menu system as
Normally Open or Normally Closed.
High: 5V (12V Tolerant)
Low: Ground
Inputs: 1 per channel.
Normally Open
Typical Alarm Device
(Opens During Alarm)
Typical Alarm Device
Alarm relays can be programmed in the menu system to
respond to macros, and video loss. See section 3.11 for
information about configuring the alarms in the menu system.
Typical wiring for Alarm Relays. Relays may be
programmed Normally Open or Normally Closed.
pin 17
Alarm
Device
pin 21
pin 22
Controlled
pin 25
Device
DVMRe Triplex DB25 Connector
Voltage: 30V (Max)
Current: 500mA (Max)
Power
Source
Power
Source
0150-0193C 11 Calibur DVMRe Triplex
External Alarm Acknowledge Input
1
5
6
9
123456789
GND
#24 AWG, twisted pair with shield
Connect a switch or similar device to ground this pin in order
to acknowledge an alarm condition, and silence associated
buzzers and relays. Connect from pin 23 to either pin 18, 19,
or 20 (ground pins).
External Device: Normally Open
Zero potential relay contact.
NOTE
All specifications subject to change without notice. GE-Interlogix believes all specifications
to be correct at time of printing, but no liability is assumed for omissions or errors.
AUX Port
The back panel of the unit is equipped with an Aux Port
(DB-9 style connector).
Do not attempt to wire directly to the DB-9
connector on the back panel.
DB-9 Connector on Back Panel
Connect the Accessory PCB (supplied with the audio equipped models) to the AUX port to access the
Audio features. Wire the audio input and output to the Accessory PCB per the pin out specifications
shown below.
Pin 1: Not Used.
Pin 2: Audio Out.
Pin 3: Ground.
Pin 4: Audio In.
Pin 5: Ground.
Pin 6: Not Used.
Pin 7: Ground.
Pin 8: Not Used.
Pin 9: Ground.
GND: Ground.
Accessory PCB
RS485 Connector
Shields are grounded at one end, preferably at the
DVMRe Triplex.
See section 3.16 for information about configuring
1 Ground (Shield) 5 Not Connected
2 Not Connected 6 Network -VE
3 Network +VE 7 Ground (Shield)
4 Not Connected 8 Not Connected
0150-0193C 12 Calibur DVMRe Triplex
82 3 4 5 6 71
RJ-45 socket on
back panel.
Ethernet Port
1
5
6
9
The cable connection configuration depends on your
network configuration:
• For a DVMRe Triplex that connects directly to a
Hub or Switch, use a straight through connection.
• For a DVMRe Triplex that connects directly to a
PC, use a cross over connection.
Consult with your MIS personnel for the specific type
of configuration. See section 3.16 for information
about configuring the ethernet settings in the menu
system.
Wire Type: Cat 5
Connector Type: RJ-45
Max. Cable Length: 100 meters / 328 ft.
Min. Cable Length: 6 feet / 1.8 meters
Hub Wiring Configuration: Straight Through
PC Wiring Configuration: Cross Over
RJ-45 Pin Configuration For Ethernet Port
Pin Use
1 TX+ 5 Not Connected
2 TX- 6 RX-
Pin Use
82 3 4 5 6 71
3 RX+ 7 Not Connected
4 Not Connected 8 Not Connected
RJ-45 socket on
back panel.
SCSI Port
The unit is equipped with a SCSI port for
connecting external archive devices. The unit only
supports a single SCSI device. The SCSI ID of the
archive device must be set to 0.
The SCSI bus must be terminated, otherwise the
system will not operate properly.
Additional menu setup may be necessary to
configure archive device. See section 3.15.
Connector: 50 Pin, High Density SCSI-2.
Gender (on unit) : Female
Compatible devices : DVSe, RAID, DAT, AIT,
CD-R, CD-RW
SCSI ID : 0
RS232 Port 1
For a Modem connection or remote control of unit. See section 3.16 for information about configuring
the modem settings in the menu system. See section 8 for RS232 Remote Control Protocols.
DB-9 Pin Configuration For Port 1
Pin Use
Pin Use
Pin Use
1 DCD 4 DTR 7 RTS
2 RX 5 Ground 8 CTS
DB-9 on back panel.
3 TX 6 Not Connected 9 Not Connected
0150-0193C 13 Calibur DVMRe Triplex
RS232 Port 2
For Event Generation and ASCII Text Insertion.
RJ-45 Pin Configuration For RS232 Port 2
Pin Use
1 Ground 5 TXD
2 Reserved 6 Not Connected
Pin Use
82 3 4 5 6 71
3 Not Connected 7 Ground
4 RXD 8 Reserved
RJ-45 socket on
back panel.
1.8 Power-Up
It is important that the power-up procedures be followed carefully. The unit uses its auto-detect
feature to detect camera signals during power-up, and configure itself automatically.
Power-up procedure
Once the system installation is complete, apply
power in the following order:
Voltage: 12 Volt DC
1. Energize the monitors and all of the cameras.
Power: 60 Watt (5 Amp)
2. Energize the DVMRe Triplex.
Connector: 2.1mm barrel, center positive
Once power is applied to the unit, it will begin its power-up procedure. The unit will begin by displaying
the software version on Monitor-A, then the unit will begin recording automatically.
Check Video Input Quality
Check the picture quality by selecting each camera for full screen display. If the picture quality is poor,
check the following items:
Power Supply Input
• The BNC connections.
• The loop-through terminations.
• The video levels of incoming signals.
• The possibility of ground loops.
• Consult the camera’s installation instructions for additional information about proper camera setup.
Check Record And Playback Quality
Record for at least three minutes at the default record rate. Then play back the recording, selecting
each camera for full screen display. Check the playback picture quality.
1.9 Minimum Recommended Menu Setup
After installation is complete, it is strongly recommended that, as a minimum, the items in the
QuickInstall menu be configured before the unit is used. All the features located in the QuickInstall
menu are also found in the Main menu. These items are provided in the separate QuickInstall menu
as a convenience for the installer.
For information about accessing and configuring the menu system, see Section 3.
0150-0193C 14 Calibur DVMRe Triplex
To find detailed information in this manual about configuring each item in the QuickInstall menu, use
the following table to locate the main menu location of each item in the QuickInstall menu.
QuickInstall
Menu Item
Change the time
Change the date
Edit Camera
Titles
Camera Disable
Record Quality
Installer
Password
Auto Disable
Now
Main Menu Location
Main Menu → Time/Date → Set Time
Main Menu → Time/Date → Set Date
Main Menu → Camera Setup → Camera Titles → Edit Titles
Main Menu → Camera Setup → Camera Disable
Main Menu → Record → Record Quality
Main Menu → Passwords → Installer Password
Main Menu → Camera Setup → Camera Disable → Auto
Disable Now
Section in
Manual
3.8
3.8
3.14
3.14
3.10
3.20
3.14
0150-0193C 15 Calibur DVMRe Triplex
e
2 DMVR
Triplex Basic Operations
2.1 Principal Operating Modes
The DVMRe Triplex has three principal modes of operation:
• Live Viewing.
• Playback.
• Recording.
All three of these modes can operate simultaneously. Each mode is discussed in detail later in this
section.
2.2 The Front Panel
1. Multiscreen Selection Buttons: 16, 10, 7, and 4 way.
2. Monitor Selection Button: Monitor A or Monitor B.
3. Multiscreen Selection Buttons: 13, 9, 6 way, and Picture-in-Picture.
4. Camera Selection Number buttons: Camera numbers 1 through 16.
5. Reverse Play Button: Playback in Reverse.
6. Freeze Button: Freezes camera images on-screen in Live mode. Pauses Playback.
7. Play Forward Button: Begins Playback.
8. Jog/Shuttle: Controls Playback speed and Menu selections.
9. Menu Button: Provides access to on-screen menus.
10. Power Indicator: Indicates power on/off condition.
11. Alarm button: Allows user to acknowledge and silence alarms.
12. Sequence Button: Sequences camera views.
13. Zoom Button: Provides a 2X digital zoom.
14. Function Button: Used in conjunction with Camera Buttons to run Macros.
15. Record Button: Used to Start and Stop Recording.
16. Stop Button: To stop Playback and return to Live mode.
17. Search Button: Access to stored video data.
18. Enter Button: Confirms selection in menus.
0150-0193C 16 Calibur DVMRe Triplex
2.3 Live Viewing
Multiscreen Display
In Live Multiscreen mode, press one of the Multiscreen buttons to activate
the multiscreen display on Monitor-A or Monitor-B. Live Multiscreens are
displayed with gray borders. For detailed information about Multiscreen
displays, see section 2.6.
Multiscreen Display With Sequencing
If a multiscreen display does not include all of the cameras, the remaining
cameras can be sequenced in the bottom right cameo. While in a multiscreen
display, press the Sequence button to begin sequencing. For detailed
information about sequencing, see section 2.8.
Full Screen Display
Select any camera for Full Screen display by pressing the Number button of
the desired camera. Pressing the Camera number button again displays the
Status Display Box. Pressing the same button a third time displays any
associated ATM or cash register ASCII text, see section 2.9.
Sequenced Full Screen Display
While in a Full Screen display, press the Sequence button to begin full
screen sequencing. The sequence list and dwell times are programmable.
For detailed information about programming the sequence list see section
2.8. For detailed information about configuring the dwell times in the menu
system, see section 3.9.
A
B
Multiscreen Buttons
Sequence Button
1
Number Button
Sequence Button
Zooming
To activate the 2x digital zoom, select the full screen display of the camera
you wish to zoom, then press the Zoom button. Zooming will be indicated by
the LED located directly above the Zoom button. Zooming is also indicated
as ZOOM on the primary monitor. Zooming works with frozen and non-frozen
images. Zoomed images can also be frozen.
While Zoomed, rotate the Jog/Shuttle to Pan and Tilt across the image.
Please note, the camera does not move during digital Pan/Tilt.
Press the Zoom button again to cancel the Zoom operations.
If the Zoom button is pressed while in a multiscreen display, the camera from the last active
NOTE
cameo is selected for full screen display. Press the Zoom button again to activate the Zoom
operation.
Freezing
Pressing the Freeze button freezes all camera images on-screen. Full
Screen freezing is indicated as FRZ on-screen. Multiscreen freezing is
indicated as * (a flashing asterisk) in each frozen cameo.
Individual cameos can be frozen in Active Cameo mode (see section 2.7).
Zoom Button
with LED
Freeze Button
Press the Freeze button again or any camera button to cancel Freeze
operations.
0150-0193C 17 Calibur DVMRe Triplex
Selecting Monitor-B
To control Monitor-B, press the lower part of the Monitor button. The
Monitor-B LED will light to indicate that the number keypad now controls
Monitor-B. Press the upper part of the Monitor button again to return the
keypad control to Monitor-A.
Monitor Button
A
B
2.4 Playback
Playback always displays on Monitor A. Playback multiscreen borders are black, as opposed to the
gray borders of the live multiscreens. Monitor B continues to display full or multiscreen live images in
playback mode. To begin playback, press the Play Forward or Reverse Play button.
Play Forward
When the Play Forward button is pressed, the unit will play forward at the rate
the data was recorded. While in Playback mode, the user may change the
playback direction, playback speed, etc. To return to Play Forward operations,
press the Play Forward button.
Reverse Play
To begin reverse playback, press the Reverse Play button.
Play Forward
Button
Fast Forward
During playback, rotate the Shuttle (the outer dial) clockwise to view data at a
higher than normal rate. Increasing the amount of rotation increases the rate of
playback.
Rewind
During playback, rotate the Shuttle counter-clockwise to view data (in reverse) at
a higher than normal rate. Increasing the amount of rotation increases the rate of
playback.
Freeze
During playback, press the Freeze button. This feature pauses all full screen and
multiscreen images
Single Frame Advance & Single Frame Rewind
During Freeze or Pause mode, rotate the Jog (the inner dial) to view the frame
directly before or after the frame displayed on-screen.
Reverse Play
Button
Jog / Shuttle
Freeze Button
0150-0193C 18 Calibur DVMRe Triplex
Stop Playback
To stop playback and return to Live Multiscreen mode on Monitor A, press the
Stop button.
Multiscreen Display
During Playback, press one of the Multiscreen buttons to activate a
multiscreen display. The 6-way and PIP multiscreen displays are not
available in Playback mode. For detailed information about Multiscreen
displays, see section 2.6.
Multiscreen Display With Sequencing
If a multiscreen display does not include all of the cameras, the remaining
cameras can be sequenced in the bottom right cameo. While in a multiscreen
display, press the Sequence button to begin sequencing. For detailed
information about sequencing, see section 2.8.
Full Screen Display
Select any camera for Full Screen display by pressing the Number button of
the desired camera. Pressing the Camera number button again displays the
Status Display Box. Pressing the same button a third time displays any
associated ATM or cash register ASCII text.
Sequenced Full Screen Display
While in a Full Screen display, press the Sequence button to begin full
screen sequencing. The sequence list and dwell times are programmable.
For detailed information about programming the sequence list see section
2.8. For detailed information about configuring the dwell times in the menu
system, see section 3.9.
Zooming
To activate the 2x digital zoom, select the full screen display of the camera
you wish to zoom, then press the Zoom button. Zooming will be indicated by
the LED located directly above the Zoom button. Zooming is also indicated
as ZOOM on the monitor. Zooming works with frozen and non-frozen
images. Zoomed images can also be frozen.
While Zoomed, use the Jog/Shuttle to Pan and Tilt across the image.
Please note, the camera does not move during digital Pan/Tilt.
Stop Button
A
B
Multiscreen Buttons
Sequence Button
1
Number Button
Sequence Button
Zoom Button
with LED
Press the Zoom button again, or another camera button to cancel the Zoom
operations.
If the Zoom button is pressed while in a multiscreen display, the camera from the last active
cameo is selected for full screen display. Press the Zoom button again to activate the Zoom
operation.
Searching Recorded Data
The DVMRe Triplex has a powerful search interface feature that allows the user to search for data on
the internal hard disk or an external archive device. The user may search the data for previous
recording sessions, text insertion, alarm conditions, or for motion in a selectable area of the scene.
0150-0193C 19 Calibur DVMRe Triplex
Because the search interface is so dynamic, the search interface is covered in detail in a separate
Monitor A
Monitor B
section of this manual. See section 5.
2.5 Recording
To begin recording, press the Record button. Recording will be indicated by the
LED located directly above the Record button. The unit always starts recording
at the end of previously recorded data.
The unit will continue recording until the record button is pressed again.
Monitor Displays During Recording
Multiscreen Live and Playback display on Monitor A and Monitor B are not affected by recording
operations.
Record Button
LIVE
PLAY
BACK
LIVE
LIVE
or
or
LIVE
LIVE
LIVE
PLAY
LIVE
BACK
0150-0193C 20 Calibur DVMRe Triplex
2.6 Display Options
Monitor A
Monitor B
Available Multiscreen Displays
Press the Multiscreen buttons to activate the multiscreen display. Pressing the individual multiscreen
button will display the corresponding multiscreen.
10-Way
7-Way
16-Way
4-Way
9-Way
6-Way
A
A
B
B
PIP
13-Way
The multiscreen display is limited to the number of camera inputs on the unit.
Sixteen-Channel unit: Capable of displaying all multiscreens.
Ten-Channel unit: Only capable of displaying 10-way through 4-way multiscreen and PIP.
Four-Channel unit: Only capable of displaying 4-way multiscreen and PIP.
The camera assignments for each multiscreen is retained (in non-volatile memory) for both Live and
Playback multiscreen mode on Monitor A, as well as Live multiscreen mode on Monitor B.
PIP: Use the Jog/Shuttle to adjust the location and size of the PIP display. Please note that the PIP
display is only available on Monitor A in Live mode, when Monitor B is in fullscreen display mode.
2.7 Active Cameos
A cameo is defined as any cell within a multiscreen display. Active Cameo mode allows the user to
access and edit each cameo individually.
Entering Active Cameo Mode
While viewing a multiscreen, enter Active Cameo mode by pressing the Enter
button. Active Cameo mode is indicated on-screen by flashing the number
and titles of the active cameo and the LED above the Enter button is lit. By
default, the top left cameo is activated.
Selecting Cameos
Select a cameo using the Jog/Shuttle to navigate the multiscreen. Rotating
the Jog selects the next screen up or down a row. Rotating the shuttle
selects the next screen in numerical order. The active cameo will always be
indicated by the flashing camera number and titles.
0150-0193C 21 Calibur DVMRe Triplex
Enter Button
Jog/Shuttle
Selecting Cameras
Display any camera in the active cameo by pressing the Number button of
the desired camera. Once a camera has been selected, the active cameo
advances to the next cameo on the right.
Number Button
The camera selection only changes the multiscreen currently being displayed. Each multiscreen must
be configured separately. Changes to the multiscreen display are saved in non-volatile memory, and
will be retained even if power is removed from the unit.
1
Freezing
Press the Freeze button to freeze the image in the selected cameo. Each
frozen cameo is indicated as * (a flashing asterisk) on-screen.
Press the Freeze button again to cancel Freeze operations.
Freeze Button
2.8 Sequencing
The sequencing feature allows a camera to be displayed briefly on-screen,
before advancing to the next camera in the sequence list. The default
sequence list displays each camera in numerical order.
Sequence Button
Dwell Time
The dwell time is the amount of time each camera is displayed on-screen before advancing to the next
camera. The Full Screen and Multiscreen Dwell Times are separately programmable in the menu
system. For detailed information about configuring the dwell times in the menu system, see section
3.9.
Autolist™ Custom Sequence List
The Autolist™ feature allows the user to create a custom sequence list, controlling the order the
cameras are displayed and the dwell time. Separate Autolists may be created for Monitor A (Live and
Playback mode) and Monitor B (Live mode). Using the Monitor button, select the monitor to be
programmed. Then, using a Number button, select any camera for full screen display.
The unit must be in Full Screen Display mode before starting to create the sequence list.
NOTE
To begin recording the Autolist™ sequence: Press the Alarm button and
Sequence button simultaneously. Autolist Program mode is indicated as
PGM on-screen.
Recording starts when the first camera number is pressed. Press the camera
numbers in the order you wish them to appear on-screen. The amount of
time between button presses determines the Dwell Time. During sequence
list programming, pressing any button other than a Number button or the
Sequence button voids the sequence list.
To end the recording: Press the Sequence button. The amount of time between pressing the last
Number button and the Sequence button determines the dwell time for the final camera in the
sequence list.
This initial camera is not part the sequence list.
Alarm Button and
Sequence Button
Returning To The Default Sequence List
The default sequence list is all cameras in numeric order with a three second dwell time.
0150-0193C 22 Calibur DVMRe Triplex
To return the unit to the default sequence list, go to the Main Menu → Sequencing → Full Screen
Dwell menu. Select 03 seconds by rotating the Jog, then press the Enter button.
Note: Any alteration of the dwell time from this menu will cancel the sequence list and return to the
default (numeric) order.
Sequencing In Cameos
While viewing a multiscreen display, additional cameras (cameras not shown in the multiscreen
display) can be sequenced in the lower right hand cameo by pressing the Sequence button. The
sequence list is not programmable, but the dwell time can be adjusted in the menu system. Press the
Sequence button again to cancel sequencing.
2.9 On-screen Indicators
There are five types of on-screen indicators.
Camera Titles: Displays the camera number and the camera title.
Status Indicators: Displays Time, Date, and Hard Disk record time left.
Conditional Indicators: Displays indicators for Freeze, Zoom, Alarm, Motion Detection, Videoloss,
Autolist™ Program mode, Macro Record and Macro Playback mode.
Status Display Box: Displays Archive Device, Network status and Image Quality Setting (Playback
mode only).
Text Display Box: Displays ATM/POS Text data.
Camera Titles
Camera Titles are displayed on either the upper or lower corner of the left hand side of the screen.
The camera title can be changed in the menu system (see section 3.14). The user can change display
position and color. See below.
Changing Position And Color Of Title And Status Indicators
Camera Titles: To change the color and position of the camera
titles, select a camera for full screen display, then press the Enter
button to advance to the next display setting. Repeatedly pressing
the Enter button advances the display settings through the
sequence show in the table on the right.
Status Indicators & Camera Titles: Select Camera 1 for full
screen display. Using the Enter button, cycle through the
sequence shown on the right. Each time the position cycle is
completed, the unit advances the Status Indicator color. Choose
Black, White or Gray.
Position Color
Top Left Black
Top Left White
Top Left Gray
Bottom Left Black
Bottom Left White
Bottom Left Gray
Title not displayed
Status Indicators
Status indicators are displayed on the upper right hand corner of the
screen.
Status indicators include:
• Time and Date (these can be turned off in the menu system, see
section 3.8). The Time and Date format can also be changed in
the menu system.
• Time remaining on Hard Disk(s).
0150-0193C 23 Calibur DVMRe Triplex
Small Cameo
Conditional Indicators
Condition Full Screen Indicator Multiscreen Indicator
Alarm
Autolist™ Program
mode
Freeze
Macro Record mode
Motion Detection
Videoloss
Zoom
F followed by macro number F followed by macro number
ALM A in cameo of camera in alarm
PGM PGM
FRZ
M M in cameo w/ motion detection
VDL V in cameo with videoloss
ZOOM ZOOM
(Asterisk) in frozen cameo
*
Status Display Box
A Status Display Box can be viewed by pressing the Camera Number button twice. Status Indicators
include:
On Live Fullscreen:
• Archive Status: Not Connected, Not Ready, Ready, Ejecting, Play, and timeleft. Timeleft
indicates the amount of time before the archive medium is full (Only available if the unit has
Background Archiving turned On).
• Network: Displays all current Network connections. Normal connection is displayed as ip.ip or --if there is no connection. Live connections are displayed as E1: ip.ip , E2: ip.ip, etc. (where ip.ip
represents the last 2 bytes of the IP Address). POTS connection is displayed as IP 1.1.
On Playback Fullscreen:
• All the above, including Image Quality Setting: High, Medium, Standard.
ATM/POS Text Display
Pressing the Camera Number a third time displays an ATM/POS text display. This feature can be
used during live viewing mode to verify that the DVMRe Triplex is receiving ATM/POS text, or in
Playback mode to review recorded text and video.
0150-0193C 24 Calibur DVMRe Triplex
Loading...
+ 53 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.