GE 0150-0193C User Manual

e
e
Caalliibbuurr
C
DVV
D
Digital Video Multiplexer Recorder
M
M
R
R
TTrriipplleex
User Manual
WARNING!
To prevent fire and electric shock, do not expose this product to rain or moisture.
The lightning flash with the arrowhead symbol,
within an equilateral triangle, is intended to alert
the user to the presence of uninsulated
"dangerous voltage" within the products enclosure
that maybe of sufficient magnitude to constitute a
risk of electric shock to persons.
CAUTION!
To prevent electric shock, do not remove cover.
No user serviceable components inside. Refer
servicing to qualified service personnel.
!
The exclamation point, within an equilateral
triangle, is intended to alert the user to the
presence of important operating and maintenance
(servicing) instructions in the literature
accompanying the product.
!
CAUTION! Lithium Battery
Danger of explosion if battery is
incorrectly replaced. Replace only
with the same or equivalent type
This equipment generates, uses and can radiate radio frequency energy, and if not installed and used
in accordance with the instructions in this manual, may cause interference to radio communications. It
has been tested and found to comply with the limits for a Class A computing device pursuant to subpart
J of part 15 of FCC rules which are designed to provide reasonable protection against such
interference when operated in a commercial environment. This equipment has also been tested and
found to comply with the requirements for a CE Class A device and TUV safety standards.
recommended by the
manufacturer.
Electrostatic-Sensitive Device!
Use proper CMOS and MOSFET handing precautions, including approved
grounded wrists straps, etc., to avoid damage to this unit or its internal
components, from electric discharge.
WARNING!
This product contains a recyclable lithium battery.
It may be illegal to dispose of this battery
improperly under local, state, or federal laws.
Check with your local waste management officials
for disposal and recycling options.
CAUTION!
ATTENTION
Operation of this equipment in a residential area may cause interference, in which case the user is
required to take all measures that are necessary, at the user's expense, to correct the interference.
0150-0193C 2 Calibur DVMRe Triplex
IMPORTANT INFORMATION
Software and/or firmware is furnished to the purchaser under a license for use on a single system. Software and/or firmware included with this equipment are the sole proprietary property of, confidential to, and copyrighted by GE-Interlogix Kalatel Division, Corvallis, Oregon, USA. The software/firmware are not to be copied or disclosed in any manner without the express written consent of GE-Interlogix.
All information and specifications furnished by GE-Interlogix are believed to be accurate and reliable. No responsibility is assumed by GE-Interlogix for neither its use nor any infringements of rights of third parties that may result from its use. No license is granted by implication or otherwise under any patent or patent rights of GE-Interlogix.
The CALIBUR brand name and product model numbers are the property of GE-Interlogix. COPYRIGHT, 2002: The contents of this manual may not be copied or reproduced in any manner or
form without the prior written consent of GE-Interlogix.
0150-0193C 3 Calibur DVMRe Triplex
Contents
1 DVMR
1.1 Products Featured In This Manual...................................................................................6
1.2 Product Description ..........................................................................................................6
1.3 Passwords......................................................................................................................... 7
1.4 Unpacking.........................................................................................................................8
1.5 Installation Environment ..................................................................................................8
1.6 Associated Equipment...................................................................................................... 8
1.7 The Back Panel .................................................................................................................9
1.8 Power-Up.........................................................................................................................14
1.9 Minimum Recommended Menu Setup...........................................................................14
2 DMVR
2.1 Principal Operating Modes.............................................................................................16
2.2 The Front Panel...............................................................................................................16
2.3 Live Viewing....................................................................................................................17
2.4 Playback..........................................................................................................................18
2.5 Recording........................................................................................................................20
2.6 Display Options............................................................................................................... 21
2.7 Active Cameos................................................................................................................21
2.8 Sequencing .....................................................................................................................22
2.9 On-screen Indicators......................................................................................................23
2.10 Triplex Mode....................................................................................................................25
e
Triplex Overview.......................................................................................6
e
Triplex Basic Operations .......................................................................16
3 Menu System Overview.......................................................................................27
3.1 Menu Notation In This Manual........................................................................................27
3.2 Accessing The Menu System.........................................................................................27
3.3 Available Menus..............................................................................................................27
3.4 Menus In This Manual.....................................................................................................28
3.5 Navigating The Menu System.........................................................................................28
3.6 Menu Shortcuts...............................................................................................................28
3.7 The Main Menu................................................................................................................29
3.8 Time/Date ........................................................................................................................29
3.9 Sequencing .....................................................................................................................31
3.10 Record ............................................................................................................................31
3.11 Alarms ............................................................................................................................37
3.12 Macro..............................................................................................................................42
3.13 Motion Detection............................................................................................................44
3.14 Camera Setup.................................................................................................................47
3.15 Archive Setup.................................................................................................................50
3.16 Audio Setup....................................................................................................................51
3.17 Communications............................................................................................................51
0150-0193C 4 Calibur DVMRe Triplex
3.18 Front Panel Lock............................................................................................................53
3.19 Factory Settings.............................................................................................................53
3.20 Passwords......................................................................................................................54
3.21 The QuickInstall Menu ...................................................................................................54
3.22 The Operator Menu ........................................................................................................55
3.23 The SystemView Menu...................................................................................................56
4 Alarms ..................................................................................................................59
4.1 Alarm Input......................................................................................................................59
4.2 Alarm Output...................................................................................................................59
4.3 Alarm Acknowledge........................................................................................................59
4.4 On-screen Displays During Alarms................................................................................59
4.5 Alarm Operations During Playback................................................................................60
4.6 Alarm History Box...........................................................................................................61
4.7 Searching For Recorded Alarms....................................................................................61
5 Searching .............................................................................................................62
5.1 Disk Analysis Screen......................................................................................................63
5.2 Motion Search.................................................................................................................63
5.3 Search Filters..................................................................................................................65
5.4 Search Results ................................................................................................................65
6 Technical Specifications.....................................................................................67
7 RS232 Event Generation/Text Insertion Protocol.............................................69
7.1 Message Structure..........................................................................................................69
7.2 Message Type.................................................................................................................69
7.3 Event Field ......................................................................................................................69
8 RS232 Remote Control Protocol........................................................................71
8.1 Front Panel Button Emulation........................................................................................71
8.2 Configuration and Status ...............................................................................................72
9 Macro Tables........................................................................................................73
9.1 Macro Functions Table...................................................................................................73
9.2 Scheduled Macro Table..................................................................................................74
10 Warranty and Service..........................................................................................75
10.1 Factory Service ...............................................................................................................75
10.2 Warranty and Return Information..................................................................................76
0150-0193C 5 Calibur DVMRe Triplex
e
1 DVMR
Triplex Overview
1.1 Products Featured In This Manual
DVMRe -4CT: Digital Video Multiplexer Recorder, Four-Channel, Color, Triplex. DVMRe -10CT: Digital Video Multiplexer Recorder, Ten-Channel, Color, Triplex. DVMRe -16CT: Digital Video Multiplexer Recorder, Sixteen-Channel, Color, Triplex.
Key To Model Numbers
1. DVMRe: Digital Video Multiplexer Recorder, Ethernet capable.
DVMRe 16 C T
2. 4, 10, or 16: Maximum number of camera inputs.
3. C: Color.
4. T: Triplex.
1 2 3 4
1.2 Product Description
The DVMRe Triplex is a video multiplexer capable of recording from multiple cameras to an internal hard drive while simultaneously providing playback. Unlike outdated time-lapse VCRs, the DVMRe Triplex records high-resolution pictures. Digital recording improves playback quality over VCRs, and eliminates the hassle of cleaning heads, changing tapes or servicing motors. The unit can also be programmed to record continuously by overwriting the oldest recorded data. Depending on the setup, the DVMRe Triplex can store from a few hours to more than 3 years of color images.
Programmable search features eliminate time consuming Fast Forwarding or Rewinding of tapes, searching for critical data. Search for recorded images or events by alarm, time, date, motion, video loss, camera number and ASCII cash register or ATM text.
Caution! This products primary purpose is to furnish video multiplexing and recording. Although the unit has alarm handling and motion detection functions, they are considered secondary features. This unit should not be the only alarm device on site.
Features
Multiplexer functionality with built-in digital recording.
Triplex simultaneous recording, playback, and live multiscreen viewing.
Remote programming and control through the RS232, RS485 and Ethernet ports.
View live or recorded images remotely using WaveReader software.
Dual multiscreen monitor displays.
Video motion detection (intrusion and activity).
Motion search.
Record speed selectable per camera.
Displays include full screen, sequenced, picture-in-picture, and multiscreens.
Alarm Handling with History Log. Pre- and post alarm recording, selectable per camera.
Archive onto Calibur DVSe Disk Array, or RAID, DAT, AIT, or CD-Rs.
PTZ control via ethernet or POTS, using CBR-KB3/J or KTD-405 keypad.
Covert camera recording (recording without display).
Daylight savings time change function.
Alarm Notification via email and/or TCP/IP dialout notification.
0150-0193C 6 Calibur DVMRe Triplex
1.3 Passwords
Passwords are provided to limit access to menus and certain functions. Two levels of password security are provided:
Operator: Limited menu access, only Operator and System View menus are available.
Installer: Complete menu access.
As a security measure, it is recommended that the Operator and Installer passwords be changed after installation is complete (see section 3.20). Store the passwords in the administrator’s secure files.
Default Passwords
Four-Channel Units
Password
Type
Operator
Installer
Factory
Defaults
Language
Ethernet
Access
Reset
Access
Level Function
Operator
Installer
Installer
Installer
Installer
Provides access to the Operator
and SystemView menus.
Provides access to all on-screen
Resets the multiplexer to the
factory defaults.
Provides access to the On-screen
Language menu.
Deactivates the ethernet
password, so that the unit may be
accessed by any PC equipped with
Ten and Sixteen-Channel Units
Password
Type
Access
Level Function
menus.
WaveReader.
Changeable
by user?
Yes
Yes
No
No
No
Changeable
by user?
Default
Password
Press ‘ENTER’
4 Times
3 4 4 4
4 1 1 1
1 4 1 4
1 1 1 1
Default
Password
Operator
Installer
Factory
Defaults
Language
Ethernet
Access
Reset
0150-0193C 7 Calibur DVMRe Triplex
Operator
Installer
Installer
Installer
Installer
Provides access to the Operator
and SystemView menus.
Provides access to all on-screen
menus.
Resets the multiplexer to the
factory defaults.
Provides access to the On-screen
Language menu.
Deactivates the ethernet
password, so that the unit may be
accessed by any PC equipped with
WaveReader.
Yes
Yes
No
No
No
Press ‘ENTER’
4 Times
3 4 7 7
8 1 1 1
5 4 1 5
1 1 1 1
1.4 Unpacking
Check the package and contents for visible damage. If any components are damaged or missing, do not attempt to use the unit, contact the supplier immediately. If the unit must be returned, it must be shipped in the original packing box.
Package Contents
The DVMRe Triplex unit.
The Alarm Interface Circuit Board (P/N 0090-0077).
Accessory PCB (P/N 0900-0127). Audio equipped models only.
The User Manual (P/N 0150-0193).
A WaveReader Software CD (P/N 0151-0005-25W11).
The WaveReader Software Manual (P/N 0150-0143).
The Archiving Addendum (P/N 0150-0194).
WaveWatch User Manual (P/N 0150-0189).
Power Supply (P/N 4310-0020)
Power Cord ( NTSC P/N 4310-0002) (PAL P/N 4310-0001)
1.5 Installation Environment
Power: Ensure that the installation site’s AC power is stable and within the rated voltage of the 12
Volt DC power supply. If the site’s AC power is likely to have spikes or power dips, use power line conditioning or an Uninterruptable Power Supply (UPS).
Ventilation: Ensure that the location planned for the installation of the unit is well ventilated. Take note of the locations of the cooling vents in the unit’s enclosure, and ensure that they are not obstructed.
Temperature: Consider the unit’s operating temperature (0 to 40 °C) and non-condensing humidity specifications (10% to 80%) before choosing an installation location. Extremes of heat or cold beyond the specified operating temperature limits may cause the unit to fail. Do not install the unit on top of other hot equipment. Leave space between rack mounted units.
Moisture: Do not expose the unit to rain or moisture. Moisture can damage the internal components. Do not install the unit near sources of water.
Chassis: Other equipment may be placed on top of the unit if it weighs less than 35 pounds (16 kilograms).
1.6 Associated Equipment
Associated equipment in a typical security system could contain the following items:
Two monitors
A Keyboard (KB3 or KTD405).
Video cameras: Composite video, 1 volt peak-to-peak.
Alarm input devices: Pressure sensors, motion detectors, etc.
Alarm output devices: Buzzers, Sirens, Flashing Lights, etc.
A PC connected via ethernet cable.
0150-0193C 8 Calibur DVMRe Triplex
An external archive device, such as a DVSe, RAID, CD-R, DAT, or AIT drive.
B
B
RS-485/1
ETHERNET
RS-485/2
RS-232/2
2345678
9
121314
For instructions regarding the connection of the associated security equipment in your system, please consult the instruction manual of the associated equipment.
1.7 The Back Panel
1
AUX
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
SVHS
SCSI
12V DC
RS-232/1
10/100
10 11
1. Camera Inputs: BNC connector, looping. Auto Terminating.
2. Composite Monitor-A Output: Composite video output with BNC style connector.
3. Y/C Monitor-A Output: Y/C video output with 4-pin mini-DIN style connector.
4. Alarm I/O: For connecting alarm inputs, and alarm output relays.
5. Power Input: For connecting the power supply.
6. Aux Port: For connecting the Accessory PCB for Audio inputs and outputs.
7. RS485 Port 1 Connector: For connecting to keyboard and other RS485 devices.
8. 10/100 Ethernet Port: For connecting to remote PC via ethernet network.
9. Composite Monitor-B Output: Composite video output with BNC style connector.
10. Y/C Monitor-B Output: Y/C video output with 4-pin mini-DIN style connector.
11. SCSI Port: For connecting SCSI compatible archive devices.
12. RS232 Port 1: For modem connection and external control of the unit.
13. RS485 Port 2 Connector: For connecting to keyboard and other RS485 devices.
14. RS232 Port 2: For Event Generation and ASCII Text insertion.
Camera Inputs
There are two BNC jacks for each camera. Either jack can receive a camera signal. The signal is looped (directly connected to the other jack), making the camera signal available to other equipment.
Cable: 75-Ohm Coaxial Connectors: BNC Auto Terminating: Yes
The camera input connectors are Auto Terminating.
Passive Looping: Yes
This means that the input signal will automatically be terminated with 75-Ohms unless a 2nd cable is connected to the 2nd BNC connector of the same camera input. Make sure there is 75-Ohm termination at the end of the video line if the signal is looped through the DVMRe Triplex.
Time base correction is performed during digital capture. As a result, cameras do not require synchronization.
See section 3.14 for information about disabling unused camera jacks in the menu system.
0150-0193C 9 Calibur DVMRe Triplex
Composite Monitor Output
A 7
G N D
When connecting directly from the DVMRe Triplex to the monitor, select the 75-Ohm impedance setting on the monitor.
If an additional device is connected to the monitor’s looping output, set the termination of the additional device as 75-Ohm, and set the termination of the monitor as Hi-Z (High Impedance).
Cable: 75-Ohm Coaxial Connectors: BNC
Y/C Monitor Output
Y/C video output has a 4-pin mini-DIN style connector. This style of connection is also referred to as SVHS and S-Video.
Cable: 75-Ohm Coaxial Connectors: BNC
Alarm I/O Port
The back panel of the unit is equipped with an Alarm
Port (DB-25 style connector).
Do not attempt to wire directly to the DB-25
connector on the back panel.
DB-25 Connector on Back Panel
Connect the Alarm PCB (supplied with the unit) to the Alarm Port. Wire all alarm inputs to the Alarm PCB per the pin out specifications shown below.
Pin 1: Alarm Input 1.
Pin 2: Alarm Input 2.
Pin 3: Alarm Input 3.
Pin 4: Alarm Input 4.
Pin 5: Alarm Input 5.
Pin 6: Alarm Input 6.
Pin 7: Alarm Input 7.
Pin 8: Alarm Input 8.
Pin 9: Alarm Input 9.
Pin 10: Alarm Input 10.
Pin 11: Alarm Input 11.
Pin 12: Alarm Input 12.
Pin 13: Alarm Input 13. Pin 14: Alarm Input 14. Pin 15: Alarm Input 15. Pin 16: Alarm Input 16. Pin 17: Alarm Output Relay #1. Pin 18: Ground. Pin 19: Ground. Pin 20: Ground. Pin 21: Alarm Output Relay #1 Common. Pin 22: Alarm Output Relay #2. Pin 23: External Alarm Silence and Acknowledge Input. Pin 25: Alarm Output Relay #2 Common.
Signal
PIN
PIN
NO1A1 A2A14 A15 A16A3 A4 A5 GND
171 214 15 163 4 5 18 7196
22 21 208910 202311241213 25
GNDA6
Signal
NO2 COM1
A8A9A10 GNDACKA11VextA12A13 COM2
Alarm PCB
Active alarm inputs vary by DVMRe model. 4 channel units (4CT) have 4 active alarm inputs. 10 channel units (10CT) have 10 active alarm inputs.
Alarm Input
An alarm condition can be activated by devices such as pressure pads, passive infrared detectors, door switches, or other similar devices.
0150-0193C 10 Calibur DVMRe Triplex
See section 3.11 for information about configuring the contacts as Normally Open or Normally Closed
pins 18
-
20
Normally Closed
DVMRe Triplex DB25 Connector
(Closes During Alarm)
Alarm Input No. 16
Ground
Output Relay No. 2
Output Relay No. 1
in the menu system.
Normally Open, Zero Potential Relay Contact: Configure in menu as Normally Open. Normally Closed, Zero Potential Relay Contact: Configure in menu as Normally Closed
TTL Active High: Configure in menu as Normally Closed.
TTL Active Low: Configure in menu as Normally Open.
Open Collector Active On: Configure in menu as Normally Open. Open Collector Active Off: Configure in menu as Normally Closed.
Alarm Input No. 1
Alarm Input No. 2 - 15
pin 1
pins 2-15
pin 16
Refer to each alarm device's manual for specific wiring details.
Typical wiring for Alarm #1 as Normally Open and Alarm #16 as Normally Closed.
Normally Open and Normally Closed Connections
Alarm Relay Output
The alarm relay output is activated when an alarm condition
exists. The alarm output is only active for the duration of the
alarm.
Output: Zero potential relay contacts, programmable in menu system as Normally Open or Normally Closed.
High: 5V (12V Tolerant) Low: Ground Inputs: 1 per channel.
Normally Open
Typical Alarm Device
(Opens During Alarm)
Typical Alarm Device
Alarm relays can be programmed in the menu system to
respond to macros, and video loss. See section 3.11 for
information about configuring the alarms in the menu system.
Typical wiring for Alarm Relays. Relays may be programmed Normally Open or Normally Closed.
pin 17
Alarm
Device
pin 21
pin 22
Controlled
pin 25
Device
DVMRe Triplex DB25 Connector
Voltage: 30V (Max) Current: 500mA (Max)
Power
Source
Power
Source
0150-0193C 11 Calibur DVMRe Triplex
External Alarm Acknowledge Input
1
5
6
9
123456789
GND
#24 AWG, twisted pair with shield
Connect a switch or similar device to ground this pin in order
to acknowledge an alarm condition, and silence associated
buzzers and relays. Connect from pin 23 to either pin 18, 19,
or 20 (ground pins).
External Device: Normally Open Zero potential relay contact.
NOTE
All specifications subject to change without notice. GE-Interlogix believes all specifications to be correct at time of printing, but no liability is assumed for omissions or errors.
AUX Port
The back panel of the unit is equipped with an Aux Port
(DB-9 style connector).
Do not attempt to wire directly to the DB-9
connector on the back panel.
DB-9 Connector on Back Panel
Connect the Accessory PCB (supplied with the audio equipped models) to the AUX port to access the Audio features. Wire the audio input and output to the Accessory PCB per the pin out specifications shown below.
Pin 1: Not Used. Pin 2: Audio Out. Pin 3: Ground. Pin 4: Audio In. Pin 5: Ground. Pin 6: Not Used. Pin 7: Ground. Pin 8: Not Used. Pin 9: Ground. GND: Ground.
Accessory PCB
RS485 Connector
Shields are grounded at one end, preferably at the
DVMRe Triplex.
See section 3.16 for information about configuring
the RS485 network address settings in the menu
system.
Wire Type:
(2-wire)
Connector Type: RJ-45 Max. Cable Length: 3200 feet / 1000 meters
RJ-45 Pin Configuration For RS485 Port
Pin Use
Pin Use
1 Ground (Shield) 5 Not Connected 2 Not Connected 6 Network -VE 3 Network +VE 7 Ground (Shield) 4 Not Connected 8 Not Connected
0150-0193C 12 Calibur DVMRe Triplex
82 3 4 5 6 71
RJ-45 socket on
back panel.
Ethernet Port
1
5
6
9
The cable connection configuration depends on your
network configuration:
For a DVMRe Triplex that connects directly to a Hub or Switch, use a straight through connection.
For a DVMRe Triplex that connects directly to a PC, use a cross over connection.
Consult with your MIS personnel for the specific type of configuration. See section 3.16 for information about configuring the ethernet settings in the menu system.
Wire Type: Cat 5 Connector Type: RJ-45 Max. Cable Length: 100 meters / 328 ft. Min. Cable Length: 6 feet / 1.8 meters Hub Wiring Configuration: Straight Through PC Wiring Configuration: Cross Over
RJ-45 Pin Configuration For Ethernet Port
Pin Use
1 TX+ 5 Not Connected 2 TX- 6 RX-
Pin Use
82 3 4 5 6 71
3 RX+ 7 Not Connected 4 Not Connected 8 Not Connected
RJ-45 socket on
back panel.
SCSI Port
The unit is equipped with a SCSI port for connecting external archive devices. The unit only supports a single SCSI device. The SCSI ID of the archive device must be set to 0.
The SCSI bus must be terminated, otherwise the system will not operate properly.
Additional menu setup may be necessary to configure archive device. See section 3.15.
Connector: 50 Pin, High Density SCSI-2. Gender (on unit) : Female Compatible devices : DVSe, RAID, DAT, AIT,
CD-R, CD-RW
SCSI ID : 0
RS232 Port 1
For a Modem connection or remote control of unit. See section 3.16 for information about configuring the modem settings in the menu system. See section 8 for RS232 Remote Control Protocols.
DB-9 Pin Configuration For Port 1
Pin Use
Pin Use
Pin Use
1 DCD 4 DTR 7 RTS 2 RX 5 Ground 8 CTS
DB-9 on back panel.
3 TX 6 Not Connected 9 Not Connected
0150-0193C 13 Calibur DVMRe Triplex
RS232 Port 2
For Event Generation and ASCII Text Insertion.
RJ-45 Pin Configuration For RS232 Port 2
Pin Use
1 Ground 5 TXD 2 Reserved 6 Not Connected
Pin Use
82 3 4 5 6 71
3 Not Connected 7 Ground 4 RXD 8 Reserved
RJ-45 socket on
back panel.
1.8 Power-Up
It is important that the power-up procedures be followed carefully. The unit uses its auto-detect feature to detect camera signals during power-up, and configure itself automatically.
Power-up procedure
Once the system installation is complete, apply power in the following order:
Voltage: 12 Volt DC
1. Energize the monitors and all of the cameras. Power: 60 Watt (5 Amp)
2. Energize the DVMRe Triplex. Connector: 2.1mm barrel, center positive
Once power is applied to the unit, it will begin its power-up procedure. The unit will begin by displaying the software version on Monitor-A, then the unit will begin recording automatically.
Check Video Input Quality
Check the picture quality by selecting each camera for full screen display. If the picture quality is poor, check the following items:
Power Supply Input
The BNC connections.
The loop-through terminations.
The video levels of incoming signals.
The possibility of ground loops.
Consult the camera’s installation instructions for additional information about proper camera setup.
Check Record And Playback Quality
Record for at least three minutes at the default record rate. Then play back the recording, selecting each camera for full screen display. Check the playback picture quality.
1.9 Minimum Recommended Menu Setup
After installation is complete, it is strongly recommended that, as a minimum, the items in the QuickInstall menu be configured before the unit is used. All the features located in the QuickInstall menu are also found in the Main menu. These items are provided in the separate QuickInstall menu as a convenience for the installer.
For information about accessing and configuring the menu system, see Section 3.
0150-0193C 14 Calibur DVMRe Triplex
To find detailed information in this manual about configuring each item in the QuickInstall menu, use the following table to locate the main menu location of each item in the QuickInstall menu.
QuickInstall
Menu Item
Change the time Change the date Edit Camera
Titles Camera Disable Record Quality
Installer Password
Auto Disable Now
Main Menu Location
Main Menu Time/Date Set Time Main Menu Time/Date Set Date Main Menu Camera Setup Camera Titles Edit Titles
Main Menu Camera Setup Camera Disable Main Menu Record Record Quality Main Menu Passwords Installer Password
Main Menu Camera Setup Camera Disable Auto Disable Now
Section in
Manual
3.8
3.8
3.14
3.14
3.10
3.20
3.14
0150-0193C 15 Calibur DVMRe Triplex
e
2 DMVR
Triplex Basic Operations
2.1 Principal Operating Modes
The DVMRe Triplex has three principal modes of operation:
Live Viewing.
Playback.
Recording.
All three of these modes can operate simultaneously. Each mode is discussed in detail later in this section.
2.2 The Front Panel
1. Multiscreen Selection Buttons: 16, 10, 7, and 4 way.
2. Monitor Selection Button: Monitor A or Monitor B.
3. Multiscreen Selection Buttons: 13, 9, 6 way, and Picture-in-Picture.
4. Camera Selection Number buttons: Camera numbers 1 through 16.
5. Reverse Play Button: Playback in Reverse.
6. Freeze Button: Freezes camera images on-screen in Live mode. Pauses Playback.
7. Play Forward Button: Begins Playback.
8. Jog/Shuttle: Controls Playback speed and Menu selections.
9. Menu Button: Provides access to on-screen menus.
10. Power Indicator: Indicates power on/off condition.
11. Alarm button: Allows user to acknowledge and silence alarms.
12. Sequence Button: Sequences camera views.
13. Zoom Button: Provides a 2X digital zoom.
14. Function Button: Used in conjunction with Camera Buttons to run Macros.
15. Record Button: Used to Start and Stop Recording.
16. Stop Button: To stop Playback and return to Live mode.
17. Search Button: Access to stored video data.
18. Enter Button: Confirms selection in menus.
0150-0193C 16 Calibur DVMRe Triplex
2.3 Live Viewing
Multiscreen Display
In Live Multiscreen mode, press one of the Multiscreen buttons to activate the multiscreen display on Monitor-A or Monitor-B. Live Multiscreens are displayed with gray borders. For detailed information about Multiscreen displays, see section 2.6.
Multiscreen Display With Sequencing
If a multiscreen display does not include all of the cameras, the remaining cameras can be sequenced in the bottom right cameo. While in a multiscreen display, press the Sequence button to begin sequencing. For detailed information about sequencing, see section 2.8.
Full Screen Display
Select any camera for Full Screen display by pressing the Number button of the desired camera. Pressing the Camera number button again displays the Status Display Box. Pressing the same button a third time displays any associated ATM or cash register ASCII text, see section 2.9.
Sequenced Full Screen Display
While in a Full Screen display, press the Sequence button to begin full screen sequencing. The sequence list and dwell times are programmable. For detailed information about programming the sequence list see section
2.8. For detailed information about configuring the dwell times in the menu system, see section 3.9.
A
B
Multiscreen Buttons
Sequence Button
1
Number Button
Sequence Button
Zooming
To activate the 2x digital zoom, select the full screen display of the camera you wish to zoom, then press the Zoom button. Zooming will be indicated by the LED located directly above the Zoom button. Zooming is also indicated as ZOOM on the primary monitor. Zooming works with frozen and non-frozen images. Zoomed images can also be frozen.
While Zoomed, rotate the Jog/Shuttle to Pan and Tilt across the image. Please note, the camera does not move during digital Pan/Tilt.
Press the Zoom button again to cancel the Zoom operations.
If the Zoom button is pressed while in a multiscreen display, the camera from the last active
NOTE
cameo is selected for full screen display. Press the Zoom button again to activate the Zoom operation.
Freezing
Pressing the Freeze button freezes all camera images on-screen. Full Screen freezing is indicated as FRZ on-screen. Multiscreen freezing is indicated as * (a flashing asterisk) in each frozen cameo.
Individual cameos can be frozen in Active Cameo mode (see section 2.7).
Zoom Button
with LED
Freeze Button
Press the Freeze button again or any camera button to cancel Freeze operations.
0150-0193C 17 Calibur DVMRe Triplex
Selecting Monitor-B
To control Monitor-B, press the lower part of the Monitor button. The Monitor-B LED will light to indicate that the number keypad now controls Monitor-B. Press the upper part of the Monitor button again to return the keypad control to Monitor-A.
Monitor Button
A
B
2.4 Playback
Playback always displays on Monitor A. Playback multiscreen borders are black, as opposed to the gray borders of the live multiscreens. Monitor B continues to display full or multiscreen live images in playback mode. To begin playback, press the Play Forward or Reverse Play button.
Play Forward
When the Play Forward button is pressed, the unit will play forward at the rate the data was recorded. While in Playback mode, the user may change the playback direction, playback speed, etc. To return to Play Forward operations, press the Play Forward button.
Reverse Play
To begin reverse playback, press the Reverse Play button.
Play Forward
Button
Fast Forward
During playback, rotate the Shuttle (the outer dial) clockwise to view data at a higher than normal rate. Increasing the amount of rotation increases the rate of playback.
Rewind
During playback, rotate the Shuttle counter-clockwise to view data (in reverse) at a higher than normal rate. Increasing the amount of rotation increases the rate of playback.
Freeze
During playback, press the Freeze button. This feature pauses all full screen and multiscreen images
Single Frame Advance & Single Frame Rewind
During Freeze or Pause mode, rotate the Jog (the inner dial) to view the frame directly before or after the frame displayed on-screen.
Reverse Play
Button
Jog / Shuttle
Freeze Button
0150-0193C 18 Calibur DVMRe Triplex
Stop Playback
To stop playback and return to Live Multiscreen mode on Monitor A, press the
Stop button.
Multiscreen Display
During Playback, press one of the Multiscreen buttons to activate a multiscreen display. The 6-way and PIP multiscreen displays are not available in Playback mode. For detailed information about Multiscreen displays, see section 2.6.
Multiscreen Display With Sequencing
If a multiscreen display does not include all of the cameras, the remaining cameras can be sequenced in the bottom right cameo. While in a multiscreen display, press the Sequence button to begin sequencing. For detailed information about sequencing, see section 2.8.
Full Screen Display
Select any camera for Full Screen display by pressing the Number button of the desired camera. Pressing the Camera number button again displays the Status Display Box. Pressing the same button a third time displays any associated ATM or cash register ASCII text.
Sequenced Full Screen Display
While in a Full Screen display, press the Sequence button to begin full screen sequencing. The sequence list and dwell times are programmable. For detailed information about programming the sequence list see section
2.8. For detailed information about configuring the dwell times in the menu system, see section 3.9.
Zooming
To activate the 2x digital zoom, select the full screen display of the camera you wish to zoom, then press the Zoom button. Zooming will be indicated by the LED located directly above the Zoom button. Zooming is also indicated as ZOOM on the monitor. Zooming works with frozen and non-frozen images. Zoomed images can also be frozen.
While Zoomed, use the Jog/Shuttle to Pan and Tilt across the image. Please note, the camera does not move during digital Pan/Tilt.
Stop Button
A
B
Multiscreen Buttons
Sequence Button
1
Number Button
Sequence Button
Zoom Button
with LED
Press the Zoom button again, or another camera button to cancel the Zoom operations.
If the Zoom button is pressed while in a multiscreen display, the camera from the last active cameo is selected for full screen display. Press the Zoom button again to activate the Zoom operation.
Searching Recorded Data
The DVMRe Triplex has a powerful search interface feature that allows the user to search for data on the internal hard disk or an external archive device. The user may search the data for previous recording sessions, text insertion, alarm conditions, or for motion in a selectable area of the scene.
0150-0193C 19 Calibur DVMRe Triplex
Because the search interface is so dynamic, the search interface is covered in detail in a separate
Monitor A
Monitor B
section of this manual. See section 5.
2.5 Recording
To begin recording, press the Record button. Recording will be indicated by the LED located directly above the Record button. The unit always starts recording at the end of previously recorded data.
The unit will continue recording until the record button is pressed again.
Monitor Displays During Recording
Multiscreen Live and Playback display on Monitor A and Monitor B are not affected by recording operations.
Record Button
LIVE
PLAY
BACK
LIVE
LIVE
or
or
LIVE
LIVE
LIVE
PLAY
LIVE
BACK
0150-0193C 20 Calibur DVMRe Triplex
2.6 Display Options
Monitor A
Monitor B
Available Multiscreen Displays
Press the Multiscreen buttons to activate the multiscreen display. Pressing the individual multiscreen button will display the corresponding multiscreen.
10-Way
7-Way
16-Way
4-Way
9-Way
6-Way
A
A
B
B
PIP
13-Way
The multiscreen display is limited to the number of camera inputs on the unit.
Sixteen-Channel unit: Capable of displaying all multiscreens. Ten-Channel unit: Only capable of displaying 10-way through 4-way multiscreen and PIP. Four-Channel unit: Only capable of displaying 4-way multiscreen and PIP.
The camera assignments for each multiscreen is retained (in non-volatile memory) for both Live and Playback multiscreen mode on Monitor A, as well as Live multiscreen mode on Monitor B.
PIP: Use the Jog/Shuttle to adjust the location and size of the PIP display. Please note that the PIP display is only available on Monitor A in Live mode, when Monitor B is in fullscreen display mode.
2.7 Active Cameos
A cameo is defined as any cell within a multiscreen display. Active Cameo mode allows the user to access and edit each cameo individually.
Entering Active Cameo Mode
While viewing a multiscreen, enter Active Cameo mode by pressing the Enter button. Active Cameo mode is indicated on-screen by flashing the number and titles of the active cameo and the LED above the Enter button is lit. By default, the top left cameo is activated.
Selecting Cameos
Select a cameo using the Jog/Shuttle to navigate the multiscreen. Rotating the Jog selects the next screen up or down a row. Rotating the shuttle selects the next screen in numerical order. The active cameo will always be indicated by the flashing camera number and titles.
0150-0193C 21 Calibur DVMRe Triplex
Enter Button
Jog/Shuttle
Selecting Cameras
Display any camera in the active cameo by pressing the Number button of the desired camera. Once a camera has been selected, the active cameo advances to the next cameo on the right.
Number Button
The camera selection only changes the multiscreen currently being displayed. Each multiscreen must be configured separately. Changes to the multiscreen display are saved in non-volatile memory, and will be retained even if power is removed from the unit.
1
Freezing
Press the Freeze button to freeze the image in the selected cameo. Each frozen cameo is indicated as * (a flashing asterisk) on-screen.
Press the Freeze button again to cancel Freeze operations.
Freeze Button
2.8 Sequencing
The sequencing feature allows a camera to be displayed briefly on-screen, before advancing to the next camera in the sequence list. The default sequence list displays each camera in numerical order.
Sequence Button
Dwell Time
The dwell time is the amount of time each camera is displayed on-screen before advancing to the next camera. The Full Screen and Multiscreen Dwell Times are separately programmable in the menu system. For detailed information about configuring the dwell times in the menu system, see section
3.9.
Autolist™ Custom Sequence List
The Autolist™ feature allows the user to create a custom sequence list, controlling the order the cameras are displayed and the dwell time. Separate Autolists may be created for Monitor A (Live and Playback mode) and Monitor B (Live mode). Using the Monitor button, select the monitor to be programmed. Then, using a Number button, select any camera for full screen display.
The unit must be in Full Screen Display mode before starting to create the sequence list.
NOTE
To begin recording the Autolist™ sequence: Press the Alarm button and Sequence button simultaneously. Autolist Program mode is indicated as PGM on-screen.
Recording starts when the first camera number is pressed. Press the camera numbers in the order you wish them to appear on-screen. The amount of time between button presses determines the Dwell Time. During sequence list programming, pressing any button other than a Number button or the
Sequence button voids the sequence list.
To end the recording: Press the Sequence button. The amount of time between pressing the last Number button and the Sequence button determines the dwell time for the final camera in the
sequence list.
This initial camera is not part the sequence list.
Alarm Button and
Sequence Button
Returning To The Default Sequence List
The default sequence list is all cameras in numeric order with a three second dwell time.
0150-0193C 22 Calibur DVMRe Triplex
To return the unit to the default sequence list, go to the Main Menu Sequencing Full Screen
Dwell menu. Select 03 seconds by rotating the Jog, then press the Enter button. Note: Any alteration of the dwell time from this menu will cancel the sequence list and return to the
default (numeric) order.
Sequencing In Cameos
While viewing a multiscreen display, additional cameras (cameras not shown in the multiscreen display) can be sequenced in the lower right hand cameo by pressing the Sequence button. The sequence list is not programmable, but the dwell time can be adjusted in the menu system. Press the
Sequence button again to cancel sequencing.
2.9 On-screen Indicators
There are five types of on-screen indicators.
Camera Titles: Displays the camera number and the camera title. Status Indicators: Displays Time, Date, and Hard Disk record time left. Conditional Indicators: Displays indicators for Freeze, Zoom, Alarm, Motion Detection, Videoloss,
Autolist™ Program mode, Macro Record and Macro Playback mode. Status Display Box: Displays Archive Device, Network status and Image Quality Setting (Playback
mode only).
Text Display Box: Displays ATM/POS Text data.
Camera Titles
Camera Titles are displayed on either the upper or lower corner of the left hand side of the screen. The camera title can be changed in the menu system (see section 3.14). The user can change display position and color. See below.
Changing Position And Color Of Title And Status Indicators
Camera Titles: To change the color and position of the camera
titles, select a camera for full screen display, then press the Enter button to advance to the next display setting. Repeatedly pressing the Enter button advances the display settings through the sequence show in the table on the right.
Status Indicators & Camera Titles: Select Camera 1 for full screen display. Using the Enter button, cycle through the sequence shown on the right. Each time the position cycle is completed, the unit advances the Status Indicator color. Choose Black, White or Gray.
Position Color
Top Left Black Top Left White Top Left Gray Bottom Left Black Bottom Left White Bottom Left Gray
Title not displayed
Status Indicators
Status indicators are displayed on the upper right hand corner of the screen.
Status indicators include:
Time and Date (these can be turned off in the menu system, see section 3.8). The Time and Date format can also be changed in the menu system.
Time remaining on Hard Disk(s).
0150-0193C 23 Calibur DVMRe Triplex
Small Cameo
Conditional Indicators
Condition Full Screen Indicator Multiscreen Indicator
Alarm
Autolist™ Program
mode
Freeze
Macro Record mode
Motion Detection
Videoloss
Zoom
F followed by macro number F followed by macro number
ALM A in cameo of camera in alarm
PGM PGM
FRZ
M M in cameo w/ motion detection
VDL V in cameo with videoloss
ZOOM ZOOM
(Asterisk) in frozen cameo
*
Status Display Box
A Status Display Box can be viewed by pressing the Camera Number button twice. Status Indicators include:
On Live Fullscreen:
Archive Status: Not Connected, Not Ready, Ready, Ejecting, Play, and timeleft. Timeleft indicates the amount of time before the archive medium is full (Only available if the unit has Background Archiving turned On).
Network: Displays all current Network connections. Normal connection is displayed as ip.ip or --­if there is no connection. Live connections are displayed as E1: ip.ip , E2: ip.ip, etc. (where ip.ip represents the last 2 bytes of the IP Address). POTS connection is displayed as IP 1.1.
On Playback Fullscreen:
All the above, including Image Quality Setting: High, Medium, Standard.
ATM/POS Text Display
Pressing the Camera Number a third time displays an ATM/POS text display. This feature can be used during live viewing mode to verify that the DVMRe Triplex is receiving ATM/POS text, or in Playback mode to review recorded text and video.
0150-0193C 24 Calibur DVMRe Triplex
2.10 Triplex Mode
Triplex mode allows the display of both live and playback images to appear on Monitor A simultaneously. Live images have gray borders, while playback images have black borders.
To enter Triplex mode, press the Play Forward button while in Play Forward mode. Alternatively, press the Play Reverse button while in Play Reverse mode. Both the Play Forward LED and the Stop LED turn on to indicate that the unit is in Triplex mode.
Monitor B always switches to a fullscreen live display whenever Triplex mode is entered.
Play Forward
When in Play Forward mode and the Play Forward button is pressed, the unit will enter the Triplex mode of operation. When Play Forward is pressed again, the unit will revert back into the normal Playback mode. While in the Triplex mode, if reverse play is in progress, the Play Forward button will change the playback direction.
Reverse Play
When in Reverse Play mode and the Reverse Play button is pressed, the unit will enter the Triplex mode of operation. When Reverse Play is pressed again, the unit will revert back into the normal Playback mode. While in the Triplex mode, if forward play is in progress, the Reverse Play button will change the playback direction.
Fast Forward
During Triplex mode, rotate the Shuttle (the outer dial) clockwise to view playback images at a higher than normal rate. Increasing the amount of rotation increases the rate of playback. Live images are not affected.
Play Forward
Button
Reverse Play
Button
Rewind
During Triplex mode, rotate the Shuttle counter-clockwise to view playback images (in reverse) at a higher than normal rate. Increasing the amount of rotation increases the rate of playback. Live images are not affected.
Freeze
During Triplex mode, pressing the Freeze button pauses all multiscreen images, both Live and Playback.
Single Frame Advance & Single Frame Rewind
During Freeze or Pause mode, rotate the Jog (the inner dial) to view the frame directly before or after the frame displayed on-screen. Only the playback images are affected.
Stop
To stop Triplex mode and return to Live mode on Monitor A, press the Stop button.
Jog / Shuttle
Freeze Button
Stop Button
0150-0193C 25 Calibur DVMRe Triplex
Multiscreen Display
During Triplex mode, press one of the Multiscreen buttons to activate a multiscreen display. The 6-way and PIP multiscreen displays are not available in Triplex mode. For detailed information about Multiscreen displays, see section 2.6. The Live and Playback images in a multiscreen display may be transposed by pressing the multiscreen button that corresponds with the current multiscreen display.
E.g. If the current display is a 13-way multiscreen with the center cameo being a playback image and the rest of the cameos being live images, pressing the 13-way multiscreen button will result in the center cameo being live and the rest of the cameos being playback images.
Multiscreen Buttons
A
B
Multiscreen Display With Sequencing
The bottom right cameo of any multiscreen will start sequencing when the Sequence button is pressed. If this camera is a playback image, the sequencing will include all the non-displayed playback cameras, and vice versa for a live image.
Sequence Button
Full Screen Display
Select any camera for Full Screen display by pressing the Number button of the desired camera. Pressing the Camera number button again displays the Status Display Box. Pressing the same button a third time displays any associated ATM or cash register ASCII text.
Number Button
1
Sequenced Full Screen Display
While in a Full Screen display, press the Sequence button to begin full screen sequencing. The sequence list and dwell times are programmable. For detailed information about programming the sequence list see section
2.8. For detailed information about configuring the dwell times in the menu system, see section 3.9.
Sequence Button
Zooming
To activate the 2x digital zoom, select the full screen display of the camera you wish to zoom, then press the Zoom button. Zooming will be indicated by the LED located directly above the Zoom button. Zooming is also indicated as ZOOM on the monitor. Zooming works with frozen and non-frozen images. Zoomed images can also be frozen.
While Zoomed, use the Jog/Shuttle to Pan and Tilt across the image. Please note, the camera does not move during digital Pan/Tilt.
Zoom Button
with LED
Press the Zoom button again, or another camera button to cancel the Zoom operations.
NOTE
If the Zoom button is pressed while in a multiscreen display, the camera from the last active cameo is selected for full screen display. Press the Zoom button again to activate the Zoom operation.
0150-0193C 26 Calibur DVMRe Triplex
3 Menu System Overview
3.1 Menu Notation In This Manual
In the following sections, there are headings like this:
q Main Menu Time/Date Set Time
Meaning: From the Main Menu, select Time/Date, then press the Enter button. The Time/Date menu
will appear. From the Time/Date menu, select Set Time, then press the Enter button. A pop-up or pull-down menu will appear.
Selected Items
Items selected in the menu system are represented in the manual as follows:
Selected Not Selected
Time/Date Time/Date
3.2 Accessing The Menu System
Enter the menu system by pressing the Menu button. A Password Box will appear on the primary monitor. Enter either the:
Operator Password: Providing limited access to the menu system. Only the Operator and System View menus are available.
Menu Button
Installer Password: Providing complete menu access. Use the Number buttons to enter the appropriate password. Default passwords are provided in the beginning of this manual, in section 1.
3.3 Available Menus
Main QuickInstall
Time/Date Sequencing Record Alarms Macro Motion Detection Camera Setup Archive Setup Audio Setup Communications Front Panel Lock Factory Settings Passwords
Change the time Change the date Edit Camera Titles Camera Disable Record Quality Installer Password Auto Disable Now
Operator SystemView
Sequencing Time/Date Display Titles Display Alarm History Archive Setup Operator Password
About DVMR View Screen 1 View Screen 2 View Screen 3 View Screen 4 View Screen 5 View Screen 6 View Screen 7 View Screen 8
0150-0193C 27 Calibur DVMRe Triplex
3.4 Menus In This Manual
QuickInstall
Shuttle
Shuttle
Each menu is covered in detail in this chapter of this manual. Menus and Menu Items appear in the manual in the same order they appear on-screen.
Main Menu
QuickInstall Menu
Operator menu
SystemView Menus
3.5 Navigating The Menu System
Selecting a Menu from the Menu Bar: When the menu system is first accessed, only the menu bar is displayed. Use the Shuttle to select the desired menu.
Opening the Drop Down Menus: Rotate the Jog. Navigating in Menus: Rotate the Jog to highlight items in the drop-down menus. Selecting Menu Items: Hit the ENTER button to select the highlighted menu item. Exiting Menus: Press the Menu button to exit a menu. From the menu bar, press the Menu button
to exit the menu system completely.
Main
Time/Date Sequencing Record Alarms Macro Motion Detection Camera Setup Archive Setup Audio Setup Communications Front Panel Lock Factory Settings Passwords
Jog
Operator SystemView
Jog
3.6 Menu Shortcuts
Zoom Button: In menu lists that have 2 settings per camera, the Zoom button will toggle all
selections. This provides a quick and easy way to enable or disable all cameras for a particular feature.
0150-0193C 28 Calibur DVMRe Triplex
Camera Button: In menu lists that provide settings per camera, a particular camera may be
accessed directly by pressing on the associated camera button. Rotate the Shuttle to modify the setting.
3.7 The Main Menu
Main Menu Overview
The Main menu contains the majority of programmable options for the DVMRe Triplex. Each item in the Main menu is described in detail in this section of the manual.
Main menu items appear in this section in the same order they appear in the menu.
3.8 Time/Date
Use this menu to specify:
Which monitors will display the time and date.
The time format: 12 or 24 hours.
The date format: MM/DD/YY, YY/MM/DD, or DD/MM/YY.
The time and date.
Whether the unit’s clock is a master or slave.
q Main Menu → Time/Date Time / Date Display
Use this menu to specify if the time and date will be displayed on:
Monitor-A.
Monitor-B.
Both Monitors.
Not Displayed
Rotate the Jog to navigate, then rotate the Shuttle to change the values. Save changes and exit the menu: Select [OK], then press the Enter button.
Time/Date Display Set Time Format Set Date Format Set Time Set Date Set Master/Slave
Time/Date Display
Monitor A : Monitor B : ON
[CANCEL] [OK]
ON
Exit the menu without making changes: Press the Menu button, or select [CANCEL], then press the Enter button.
q Main Menu Time/Date Set Time Format
Rotate the Jog to set the desired time format. Select from either:
12 Hour
24 Hour
Press the Enter button to confirm the selection and exit the menu. Press the Menu button to exit the menu without making changes.
0150-0193C 29 Calibur DVMRe Triplex
Time Format Setup
Select Format
12 HOUR
q Main Menu Time/Date Set Date Format
Time Setup
[CANCEL] [OK]
Date Setup
[CANCEL] [OK]
Master/Slave Select
Rotate the Jog to set the desired date format. Select from either:
MM/DD/YY
DD/MM/YY
YY/MM/DD
Press the Enter button to confirm the selection and exit the menu. Press the Menu button to exit the menu without making changes.
q Main Menu → Time/Date Set Time
1. Rotate the Shuttle to navigate, highlight HH MM SS.
2. Press the Enter button, the highlighting will move to the row of numbers.
Date Format Setup
Select Format
MM/DD/YY
3. Enter the time in Hours, Minutes, and Seconds. Rotate the Jog to change the values and the Shuttle to navigate.
HH MM SS
03 05 53
4. Press the Enter button to confirm the selection and exit the edit mode.
5. To save the changes and exit the menu: Rotate the Jog to select [OK], then press the Enter button.
6. To exit the menu without making changes: Rotate the Jog to select [CANCEL], then press the Enter button.
q Main Menu → Time/Date Set Date
1. Press the Enter button, the highlighting will move to the row of
numbers.
2. Enter the date in Months, Days, Years. The day of the week is calculated automatically. Rotate the Jog to change the values and the Shuttle to navigate.
3. Press the Enter button to confirm the selection and exit the edit mode.
4. To save the changes and exit the menu: Rotate the Jog to select [OK], then press the Enter
button.
5. To exit the menu without making changes: Rotate the Jog to select [CANCEL], then press the Enter button.
MM DD YY Day
01 25 60 MON
q Main Menu Time/Date Set Master / Slave
If several multiplexers are installed and connected via RS485 a network, one of the multiplexers may be set as the master clock. This unit will control the date and time (including daylight savings time) for all of the other units.
Select One unit from the RS485 network as the master clock by selecting YES in this menu. All other units must be set as NO (Default).
0150-0193C 30 Calibur DVMRe Triplex
Master Clock
NO
3.9 Sequencing
Fullscreen Dwell
Record Quality
Event Settings
Use this menu to specify:
The multiscreen dwell time.
The full screen dwell time.
The dwell time is the amount of time each camera is displayed on-screen (while sequencing) before advancing to the next camera.
q Main Menu Sequencing Multiscreen Dwell
Rotate the Jog to change the desired dwell time (from 1 to 30 seconds). The default is 3 seconds.
1. Press the Enter button to confirm the selection and exit the menu.
2. Press the Menu button to exit the menu without making changes.
q Main Menu Sequencing Fullscreen Dwell
Rotate the Jog to change the desired dwell time (from 1 to 30 seconds). The default is 3 seconds.
1. Press the Enter button to confirm the selection and exit the menu.
2. Press the Menu button to exit the menu without making changes.
Multiscreen Dwell
Fullscreen Dwell
Multiscreen Dwell
(Time in Seconds)
03
(Time in Seconds)
03
3.10 Record
Use this menu to:
Specify the record quality: High, Medium, or Standard.
Specify if a camera is to be used for event recording,
time-lapse recording, or both.
Specify the time-lapse record rate per camera.
Specify the event record rate per camera.
Specify the activity record rate per camera.
Specify the alarm record rate.
Set the Record Lock feature.
Perform disk maintenance by Deleting, Un-deleting, or
Destroying previously recorded video.
Specify how the unit will handle data overwrite issues once the hard disk becomes full.
Record Timer
Timelapse Record Rate Event Record Rate Activity Record Rate Alarm Record Rate Record Mode Disk Maintenance Record Lock ADM
0150-0193C 31 Calibur DVMRe Triplex
Day Start Stop Macro ON/OFF
Record Quality
[CANCEL] [OK]
q Main Menu Record Record Timer
Use this menu to setup Preset Record Timer Events.
1. Rotate the Shuttle to select a timed event from the list.
2. Press the ENTER button to enter the Edit mode.
3. Rotate the Shuttle to navigate to the desired field.
4. Rotate the Jog to change the values of the selected field.
5. Press the Enter button to exit the Edit mode.
6. Rotate the Jog to highlight the [OK] field and press the ENTER button to save the changes.
q Main Menu Record Record Quality
Use this menu to specify the record quality for each camera. Decreasing the record quality decreases the amount of disk space required to store the images, due to a higher compression scheme.
Record Quality Picture Quality Disk Space Needed
High Excellent Most Medium Good Medium
22:59 01:59 NONE ON
7
MON-FRI 05:56 04:06 10 ON
-- --:-- --:-- -- --
[OK]
Hit ‘ENTER’ to toggle EDIT Mode
Camera 01:
High
Camera 02: High Camera 03: High Camera 04: High : :
Standard Fair Least
Camera 16: High
1. Rotate the Jog to navigate, and the Shuttle to change the values.
2. To save changes and exit the menu: Select [OK], then press the Enter button.
3. Exit the menu without making changes: Press the Menu button, or select [CANCEL], and then press the Enter button.
q Main Menu Record Event Settings
Use this menu to specify how each camera will record during normal and event conditions.
TL: Records at the Time-lapse Record Rate under normal conditions. Does not change record rate during an event.
Event: Records during events at the Event Record Rate. Camera does not record under normal conditions.
Event + TL: Records at the Time-lapse Record Rate under normal conditions. Records at the Event Record Rate during events.
Event Camera Settings
Camera : Type : TL Pre Event Duration : 00 Post Event Duration: 000
[CANCEL] [OK]
01
0150-0193C 32 Calibur DVMRe Triplex
About Events: An Event is an action that the unit acknowledges by recording at the
NOTE
Event Record Rate, yet it is not cause for an Alarm. Events may be created two ways, via RS232 text insertion and Activity detection.
Example of an Event: A camera is pointed at the front door inside the lobby during business hours. With the Event Camera Settings Type set to Event, the unit does not record while the doorway is empty. When activity motion detection senses that someone is entering or leaving the doorway, the unit begins recording at the Event Record Rate and stops recording when the motion ceases.
RS232 Event: See section 7 for information about generating an Event via RS232, and optionally inserting ASCII text to mark the Event.
Activity Detection Event: See Setup Parameters in section 3.13 for detailed information about configuring activity detection as an event in the menu system.
Pre Event Duration: The unit will record up to 5 seconds of data ahead of the event trigger, at the Event Record Rate. Select from 0 to 5 seconds.
Post Event Duration: The unit will record up to 250 seconds after the completion of the Event, at the Event Record Rate. Select from 0 to 250 seconds.
q Main Menu Record Timelapse Record Rate
The unit records at the Timelapse Record Rate under normal conditions, when there are no alarms, events, or activity present. Record rates are measured in both Pictures Per Second (pps) and Seconds Per Picture (spp).
The maximum record rate per camera is inversely proportional to the number of cameras connected to the unit. The fewer cameras connected, the higher the maximum record rate for each camera, and vice versa. The maximum record rate for multiple cameras is 48pps (NTSC)(40pps PAL). The maximum record rate for a single camera is 30pps (NTSC)(25pps PAL).
The bottom right corner of the menu contains a record duration calculator. The top line indicates the estimated recording time for the unit in Time-lapse record mode only. The bottom line indicates the estimated recording time, taking into consideration the amount of time the unit will spend in Activity, Event, and/or Alarm record mode.
Timelapse Record Rate
Camera 1 : Camera 2 : 0.29 pps 3.5 spp Camera 3 : 0.34 pps 2.9 spp Camera 4 : 0.57 pps 1.8 spp : : : Camera 15 : 0.40 pps 2.5 spp Camera 16 : 0.40 pps 2.5 spp
0.40 pps 2.5 spp
[CANCEL] [OK]
8 days 5 h (TL) 8 days 5 h (Total)
1. Rotate the Jog to navigate, and the Shuttle to change the values.
0150-0193C 33 Calibur DVMRe Triplex
2. To save changes and exit the menu: Select [OK], and then press the Enter button.
Estimate of the % of time each
camera will typically spend in
Event mode. For example if you
events each day, each lasting 3
minutes on average, then the %
3. To exit the menu without making changes: Press the Menu button, or select [CANCEL], then press the Enter button.
q Main Menu Record Event Record Rate
The unit will record at the Event Record Rate when an Event is activated. Events can be activated by RS232 ev ent generation or activity detection. See Event Settings on page 29.
Record rates are measured in both Pictures Per Second (pps) and Seconds Per Picture (spp). The maximum record rate per camera is inversely proportional to the number of cameras connected to
the unit. The fewer cameras connected, the higher the maximum record rate for each camera, and vice versa. The maximum record rate for multiple cameras is 48pps (NTSC)(40pps PAL). The maximum record rate for a single camera is 30pps (NTSC)(25pps PAL).
The bottom right corner of the menu contains a record duration calculator. The top line indicates the estimated recording time of the cameras in Event record mode only. The bottom line indicates the estimated recording time, taking into consideration the amount of time the unit will spend in Time-lapse, Activity, Event, and/or Alarm record mode.
Event Record Rate
Camera 1 : Camera 2 : 0.29 pps 3.5 spp Camera 3 : 0.34 pps 2.9 spp Camera 4 : 0.57 pps 1.8 spp : : : Camera 15 : 0.40 pps 2.5 spp Camera 16 : 0.40 pps 2.5 spp
0.40 pps 2.5 spp
[CANCEL] [OK]
% Time: 4%
% Time: 4%
125 days 8 h (EVENT) 10 days 7 h (Total)
expect to have about 20 total
of the time will be (1 hour/24 hours)
4%.
1. Rotate the Jog to navigate, and the Shuttle to change the values.
2. To save changes and exit the menu: Select [OK], and then press the Enter button.
3. To exit the menu without making changes: Press the Menu button, or select [CANCEL], then press the Enter button.
q Main Menu Record Activity Record Rate
The unit will record at the Activity Record Rate when the camera is in normal Timelapse Record Mode and activity is detected in the camera scene. Activity should not be linked to Event, in which case the Event Record Rate will be used.
Record rates are measured in both Pictures Per Second (pps) and Seconds Per Picture (spp).
0150-0193C 34 Calibur DVMRe Triplex
The maximum record rate per camera is inversely proportional to the number of cameras connected to
total periods of activity each day,
each lasting 3 minutes on average,
each lasting 3 minutes on average,
the unit. The fewer cameras connected, the higher the maximum record rate for each camera, and vice versa. The maximum record rate for multiple cameras is 48pps (NTSC)(40pps PAL). The maximum record rate for a single camera is 30pps (NTSC)(25pps PAL).
The bottom right corner of the menu contains a record duration calculator. The top line indicates the estimated recording time of the cameras in Activity record mode only. The bottom line indicates the estimated recording time, taking into consideration the amount of time the unit will spend in Time-lapse, Activity, Event, and/or Alarm record mode.
Activity Record Rate
Camera 1 : Camera 2 : 0.29 pps 3.5 spp Camera 3 : 0.34 pps 2.9 spp Camera 4 : 0.57 pps 1.8 spp :
0.40 pps 2.5 spp
% Time: 4%
% Time: 4%
Estimate of the % of time each camera will typically spend in periods of activity. For example if you expect to have about 20
then the % of the time will be 4%. (1 hour/24 hours)
: : Camera 15 : 0.40 pps 2.5 spp Camera 16 : 0.40 pps 2.5 spp
68 days 11 h (ACTIVITY)
[CANCEL] [OK]
9 days 16 h (Total)
1. Rotate the Jog to navigate, and the Shuttle to change the values.
2. To save changes and exit the menu: Select [OK], and then press the Enter button.
3. To exit the menu without making changes: Press the Menu button, or select [CANCEL], then press the Enter button.
q Main Menu Record Alarm Record Rate
During an alarm, the unit records at the alarm record rate. The bottom of the menu contains a record duration calculator. The top line indicates the estimated recording time of the cameras in Alarm record mode only. The bottom line indicates the estimated recording time, taking into consideration the amount of time the unit will spend in Time-lapse, Activity, Event, and/or Alarm record mode.
The configuration of the Alarm Record Rate is closely associated with the Alarm Record Mode. For detailed information about configuring the Alarm Record Mode, see Alarm Record mode in section 3.11.
Global Alarm Record Rate
% Time:
1%
60 pps
40 days 20 h (Alarm) 15 days 11 h (Total)
[CANCEL] [OK]
0150-0193C 35 Calibur DVMRe Triplex
Estimate of the % of time the unit will typically spend in alarm mode. For example if you expect to have about 5 total periods of alarms each day,
then the % of the time will be 1%. (15 min/24 hours)
Record Duration Calculator
1. Rotate the Jog to navigate, and the Shuttle to change the values.
No overwrite
OFFONOFF
2. To save changes and exit the menu: Select [OK], and then press the Enter button.
3. To exit the menu without making changes: Press the Menu button, or select [CANCEL], then press the Enter button.
q Main Menu Record Record Mode
Use this menu to specify how the unit will handle data overwrite issues once the hard disk becomes full.
No Overwrite:
Recording starts at the end of the last recording.
Recording stops when disk becomes full.
When the hard disk becomes full, the unit displays an on-screen message indicating that the
device is full and that the archive device has stopped recording. The user must acknowledge the message by pressing the Enter button.
Write once
Continuous
Write Once:
Recording starts at the end of the last recording.
Recording stops when disk becomes full.
The user is prompted to authorize overwriting old data.
Continuous:
Recording starts at the end of the last recording.
Unit overwrites all previously recorded data, overwriting the oldest data first.
The unit does not stop recording when disk becomes full.
q Main Menu Record Disk Maintenance
Use the Jog to select from the following options, then press the
Enter button to begin. Delete: Delete all data from the hard disk (with the possibility of restoring it). Undelete: Restore data that has been deleted, but not yet overwritten. Destroy: Erase all data from the hard disk permanently, without the possibility
of restoring it. Selecting this option brings up a confirmation dialog box.
q Main Menu → Record Record Lock
Use this menu to set the Record Lock feature. This feature disables the front panel record button. Setting Record Lock to ON will start the unit recording if it is not currently in the Record mode.
Delete
UnDelete Destroy
ADM (Auto Delete Mode)
The ADM feature prevents the unit from displaying or archiving any search results that are more than thirty days old. This feature may be required by law in some jurisdictions. If required by local authorities, the ADM feature must be turned On. Typically this feature is turned Off.
0150-0193C 36 Calibur DVMRe Triplex
ON
3.11 Alarms
Alarm Action
Relay Configuration
Input Configuration
Use this menu to configure the alarm handling features of the unit.
Caution! The DVMRe Triplex’s primary function is to furnish video multiplexing and recording with a multiscreen display. Although the unit has alarm handling and motion detection functions, these are considered secondary features. This unit should not be the only alarm device on site.
q Main Menu Alarms Input Configuration
Configure the alarm inputs as either Normally Open or Normally Closed. Configure inputs as follows. Normally Open Zero Potential Relay Contact: Configure in menu as
Normally Open. Normally Closed Zero Potential Relay Contact: Configure in menu
as Normally Closed
TTL Active High: Configure in menu as Normally Closed.
Alarm Latch
Alarm Record Mode Enable / Disable Alarm History Link to a Macro Fullscreen Alarm
Buzzer Setup Videoloss Action Pre Alarm Duration Notification Archive Alarms
TTL Active Low: Configure in menu as Normally Open. Open Collector Active On: Configure in menu as Normally Open. Open Collector Active Off: Configure in menu as Normally Closed.
q Main Menu → Alarms Alarm Latch
This feature determines how the unit latches alarm conditions. Selecting from the following options. Latched: The alarm is activated until it is silenced and acknowledged
by the user. Transparent: The alarm is active only while receiving alarm input.
The alarm condition is canceled when the alarm input ceases. Timed Out: The alarm condition is latched for the amount of time selected in this menu, then it is
automatically silenced and acknowledged. If the alarm input exceeds the duration specified in this menu, the unit silences and acknowledges the alarm when the alarm input ceases. Select the timeout duration, the range is from 1 to 250 seconds.
Transparent alarms cannot be silenced and acknowledged. If transparent mode is preferred, but the ability to silence and acknowledge alarms is desired, select Timed Out and set the Alarm Timeout to two seconds.
Latched
Transparent Timed Out
0150-0193C 37 Calibur DVMRe Triplex
q Main Menu Alarms Alarm Action
Alarm Action Setup
This menu is not available on 4-channel units. Only the full screen alarm display is available on the 4-channel unit. Therefore, a 4 channel unit will always be limited to the default values in this menu, i.e. no presets linked to alarms and alarm relay is always Relay 1.
Input: Select the input you wish to configure. Freeze: Selecting Yes will freeze the alarm camera display (quadrant 1)
at the time the alarm is activated. Cameras: This setting determines the four cameras displayed on-screen
when an alarm is received. The camera group contains the camera in alarm and three associated cameras.
Default Settings: The first camera in the list is the camera in alarm. The second camera in the list is the camera that precedes the alarm camera numerically. The third and fourth cameras in the list are the two cameras following the alarm camera numerically.
Preset: Use this feature to send a camera to a preset when an alarm is activated. The preset number corresponds directly with the camera number located directly above it in this menu. Select from 1 through 16. If this field is left blank, the camera will not respond. In the example above, Camera 1 will go to Preset 1, while Camera 2 will go to Preset 9.
Relay: Configure which relay will be triggered when an alarm is activated per camera. Select from:
Input : Freeze : Yes Cameras: 01 16 02 03 Presets: 01 -- 09 -­Relay : 1
[CANCEL] [OK]
01
1
2
1 + 2
None
Rotate the Jog to navigate and the Shuttle to change the values.
q Main Menu Alarms Alarm Record Mode
Alarm Record Mode
Use this menu to determine how the unit will record cameras in alarm. No Change: Unit changes to the Alarm Record Rate, but it does not
give priority to the camera in alarm.
Select Mode
Interleaved
Exclusive: The unit records only the camera (or cameras) in alarm. Interleaved: Alarmed cameras are recorded at a higher rate than
non-alarm cameras. The unit accomplishes this by interleaving images of alarmed cameras between images from non-alarmed cameras in the record list. Interleaved is the
recommended mode of operation. Example of Record Lists:
No Change record list for 8 cameras, Camera-4 in alarm. 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Exclusive record list for 8 cameras, Camera-4 in alarm. 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 Interleaved record list for 8 cameras, Camera-4 in alarm. 1 4 2 4 3 4 5 4 6 4 7 4 8 4 1 4
q Main Menu → Alarms Enable / Disable
Use this menu to Enable or Disable the alarm inputs. Select from the following:
0150-0193C 38 Calibur DVMRe Triplex
Individual Enable
Enable All Disable All
Individual Enable: Allow the user to access the Alarm
Fullscreen Alarm
Enable submenu, and enable or disable alarm inputs on a per camera basis.
Enable All
Disable All
Rotate the Jog to navigate, and the Shuttle to change the values.
Save changes and exit the menu: Select [OK], then press the Enter button.
Exit the menu without making changes: Press the Menu button, or select [CANCEL], then press the Enter button.
q Main Menu → Alarms Alarm History
Use this window to view a list of the 100 most recent alarms. Alarms are displayed 10 at a time. Rotate the Jog to scroll through the alarms.
Information displayed in this window is:
The alarms number in the list.
The date of the alarm (month and day).
The time of the alarm (hours, minutes, and seconds).
The number of the camera input in alarm.
Alarm History Box
001- 02/04 18:40:32 16 002- 02/15 12:00:10 11 003- 02/28 10:10:20 08 : : 010- 03/15 05:12:16 04
[OK]
q Main Menu Alarms Link To A Macro
Use this menu to link an alarm input to a macro. If a link is created, a macro will run each time that alarm is activated.
Alarm: Select the alarm input you would like to link.
Macro: Select the macro number you wish to link to. Leave this
setting blank if you do not wish to link to a macro. Rotate the Jog to navigate, and the Shuttle to change
the values.
Save changes and exit the menu: Select [OK], then press the Enter button.
Exit the menu without making changes: Press the Menu button, or select [CANCEL], then press the Enter button.
q Main Menu → Alarms Fullscreen Alarm
Selecting Yes from this menu will cause the unit to always display the alarm camera fullscreen.
Selecting No from this menu will cause the unit to display the 4-way display configured in the Main Menu Alarms Alarm Action Setup menu.
Fullscreen
NO
This menu selection is not available on 4-channel DVMRe Triplex units, since Fullscreen Alarm Mode is the only alarm mode available.
0150-0193C 39 Calibur DVMRe Triplex
Buzzer Setup
[CANCEL] [OK]
Videoloss Action
Relay 1: Disable
Buzzer : Enable
Pre Alarm Duration
TCP/IP Dialout
q Main Menu Alarms Relay Configuration
Use this menu to configure each relay output as either:
Normally Open
Normally Closed
q Main Menu Alarms Buzzer Setup
Use this menu to configure the internal buzzer. Global Buzzer: The Global Buzzer setting acts as a master On/Off
switch. Setting the Global Buzzer to OFF deactivates all buzzer activity.
Live Alarm Buzzer: Activates while receiving alarm input. Videoloss Buzzer: Activates when video loss is detected.
Disabling the Videoloss buzzer disables all videoloss buzzer activity. Videoloss buzzers may be disabled on a per camera basis in the
Alarms Videoloss Action menu. Playback Buzzer: Activates during playback of recorded alarms.
q Main Menu → Alarms Videoloss Action
Use this menu to configure how the unit responds to videoloss.
Relay Configuration
Relay 01: Relay 02: N/CLOSED
[CANCEL] [OK]
Global Buzzer : Live Alarm Buzzer: ON Videoloss Buzzer : ON Playback Buzzer : ON
N/OPEN
ON
Camera: Select the camera you wish to configure. Relay 1: If enabled, the unit will activate Relay 1 when videoloss
is detected. Relay 2: If enabled, the unit will activate Relay 2 when videoloss is
detected. Buzzer: Use this setting to disable the videoloss buzzer activation
on a per camera basis. To disable videoloss buzzer activation on all cameras go to the Main Menu Alarms Buzzer Setup menu, described in the previous section.
q Main Menu Alarms Pre Alarm Duration
During recording, the unit stores up to 5 seconds of recorded information in a buffer. This data can be automatically retrieved when an alarm is activated. Select the amount of time just previous to the activation of an alarm you wish to retrieve.
q Main Menu Alarms Notification
Use this menu to select:
Email Alarm Notification.
Camera :
Relay 2: Enable
[CANCEL] [OK]
(Time in Seconds)
Email
01
05
0150-0193C 40 Calibur DVMRe Triplex
TCP/IP Dialout Notification.
Email Notification Setup
Timezone Delta:
This screen allows the user to setup the types of events to be notified of, and the email addresses (up to two) to be notified. Follow the context sensitive on-screen instructions to setup the individual fields.
Email Notification Setup
One or more of these
fields must be set to
ENABLE to receive an
email notification of
the selected event.
Obtain the parameters
for these two fields from
your IT Department.
Notify Vidloss: Notify Alarm: Notify Record: Notify Archive: Email User 1: Email Domain 1: Email User 2: Email Domain 2: SMTP Server: SMTP Port:
Format of email address: user@domain The timezone delta is relative to Universal Time (UT/GMT)
ENABLE
DISABLE DISABLE DISABLE john.doe somecompany.com jane.doe somecompany.com
0. 0. 0. 0 25
-07 [CANCEL] [OK]
Email Address Format
The format of the email addresses should be entered as follows. If the email address to be notified is
john.doe@somecompany.com, then john.doe should be entered in one of the Email User fields and
somecompany.com should be entered in the subsequent Email Domain field.
Timezone Delta
The timezone delta integer is based on how many time zones your current time zone is from Greenwich Mean Time (GMT). To calculate your timezone delta use the following formula.
Current time – Greenwich Mean Time = Timezone Delta For example: If the current time is 0900 hours, and the GMT is 1600 hours, then the timezone delta
would be –0700 and should be expressed in the field as –07.
To obtain the GMT open an Internet Browser on an Internet connected PC and point the browser to
www.greenwichmeantime.com.
TCP/IP Dialout Notification Setup
This screen allows the user to setup the types of events to be notified of, and the IP addresses (up to two) of the PC(s) where the WaveReader software resides.
WaveReader must be running on the receiving PC(s) and Alarm Monitoring must be setup. See Alarm Monitoring in the WaveReader Manual for details.
0150-0193C 41 Calibur DVMRe Triplex
TCP/IP Dialout Notification Setup
Macro Record
Select Macro
One or more of these
fields must be set to
ENABLE to receive an
email notification of
the selected event.
The IP Addresses
of the PC on which
the WaveReader
Software resides
Notify Vidloss: Notify Alarm: Notify Record: Notify Archive: Notify Menu Access: Notify Power Up: Notify Connection: Primary Host: Backup Host: Port: Notification Interval (minutes):
[CANCEL] [OK]
DISABLE
DISABLE DISABLE DISABLE DISABLE DISABLE DISABLE
0. 0. 0. 0
0. 0. 0. 0 27
10 Immediate
The Notification Interval can be set from 1 minute to 60 minutes, or immediately upon the event.
q Main Menu Alarms Archive Alarms
Selecting Enable from this menu will cause the unit to activate Relay 2 if a malfunction occurs while archiving.
Archive Alarm
Relay 2
ENABLE
3.12 Macro
A macro is a recorded sequence of keystrokes. The number of macros depends on the number of camera inputs (4, 10 or 16). Each macro can have up to 32 keystrokes.
Use this menu to:
Enter Macro Record mode.
Program a scheduled start time for a macro.
Edit the RS232 command string for each submacro.
q Main Menu → Macro Macro Record
Note: Do not attempt macro programming while the front panel is locked.
To begin recording a macro:
1. Select the macro number you wish to record, then press the Enter button. The unit will automatically exit the menu system and go to a starting point. Macro Record mode is indicated as F and the Macro Number on-screen.
Macro Record
Timed Macro Start Edit Submacro
01
2. From this point, begin recording the desired keystroke sequence. Record up to 32 keystrokes. If 32 keystrokes are exceeded, the unit will end the macro recording automatically.
0150-0193C 42 Calibur DVMRe Triplex
3. When finished programming, press the Function button then the Enter button to end the macro recording. A form is provided in section 9 to keep track of recorded macro functions.
Keystroke count while in the menu system: While recording a macro, entering the
NOTE
During macro recording, the following button combinations perform special functions.
Button Sequence Resulting Action
menu system, changing multiple menu items, and exiting the menu system are only counted as one keystroke. Using the Jog to navigate the menu system does not count as keystrokes. Once the menu system has been exited, re-entering the menu system will count as a second keystroke.
Not all menu items can be programmed using macros. For a complete list of macro programmable menu items, see the table below.
Function then 1. Function then 2. Function then 3. Function then 4. Function then 5. Function then 6. Function, Function, then
Submacro number. Function then Enter.
Activate Relay 1 output. Reset Relay 1 output. Pause macro for 1 second. Pause macro for 5 seconds. Activate Relay 2 output. Reset Relay 2 output. Program a specific submacro to activate when the macro is run.
End macro recording
Macro Excluded Features
The following core features or settings cannot be programmed by Macro.
Disk Maintenance.
Erase Archive Medi um.
POTS Setting.
Ethernet Setting.
RS485 Network Address.
Front Panel Lock/Unlock.
Record Timer.
q Main Menu Macro Timed Macro Start
Use this menu to program scheduled start times for macros. Up to 20-scheduled start times can be programmed in this menu.
Event: Select the scheduled start event you wish to edit. Day: Select the start day (Monday – Sunday) of the macro.
Select ** (double asterisks) to run the macro every day. Select None to cancel the scheduled start time.
Time: Select the start time for the macro. Macro: Select the desired macro number.
0150-0193C 43 Calibur DVMRe Triplex
Timed Macro Setup
Event : Day : Monday Time : 00:00 Macro : 01
[CANCEL] [OK]
01
A form is provided in section 9 to keep track of scheduled macros.
Setup Parameters
Setup Active Zones
Indicate Detection
q Main Menu Macro Edit Submacro
A submacro is an RS232 command string used to control a peripheral device. Submacros are activated during macros. See the table on page 43 for information about programming a macro to activate a submacro.
Select the submacro you wish to edit from the menu system. This menu will appear.
Edit Submacro 01
080 066 066 010 --- --- --- --- --- ---
[P] [B] [B] [0]
[CANCEL] [OK]
ENTER key starts Submacro edit
Use this menu to create the RS232 command string. Press the Enter button to Enter and Exit the submacro edit mode. Rotate the Jog/Shuttle to navigate among the fields and change the values. Each byte value can be set from 0 to 255.
Running A Macro
A macro is a recorded sequence of up to 32 keystrokes. To activate a macro, press the Function button followed by the Number button of the desired macro. While running, the macro is indicated on-screen as the letter F and the macro number.
The user can cancel the macro at any time by pressing the Function button.
{F}
Function and
Number Buttons
Daylight Savings Time
To adjust the time one hour for daylight savings time, press the Function button, then the Sequence button. If this function is activated during April, one hour is added to the time. If this function is activated in October, one hour is subtracted from the time. This function will only operate once per time period.
{F}
Function and
Sequence Buttons
3.13 Motion Detection
Use this menu to:
Enable motion detection on a per camera basis.
Activate individual zones in a scene to respond to motion
detection.
Activate the on-screen motion detection indicator.
Set motion detection as Activity detection or Intrusion Detection.
Configure the motion detection parameters on a per camera basis.
Enable/Disable Detection
1
0150-0193C 44 Calibur DVMRe Triplex
Detection Enable
Camera 02: Disable
q Main Menu Motion Detection Enable/Disable Detection
Selecting Enable All or Disable All from this menu will activate or deactivate motion detection on all cameras.
Selecting Individual Enable from this menu will bring up the following menu.
Individual Enable
Enable All Disable All
Individual Enable Menu
Use this menu to enable or disable motion detection on a per camera basis. Rotate the Jog to navigate, and the Shuttle
Camera 01:
Enable
to change the values.
Camera 03: Enable : : Camera 16: Enable
[CANCEL] [OK]
q Main Menu Motion Detection Setup Parameters
Use this menu to select the Camera, Motion Detection Type, and Sensitivity of the Motion Detection you wish to configure.
Motion Detection Parameters Setup
Camera Motion Detection Type Sensitivity Relay Output Link to Event
Rejection Target Size Link to Alarm
01
ACTIVITY 06 2
---
LOW 01 NONE
[CANCEL] [OK]
Navigate in this menu using the Jog to select the field and the Shuttle to change the parameters.
Activity Vs. Intrusion
Activity Detection is a simple type of motion detection having only a sensitivity setting and a relay output. Intrusion Detection is a more sophisticated type of motion detection, with additional features such as false alarm rejection levels, minimum target size, and an alarm output.
0150-0193C 45 Calibur DVMRe Triplex
Activity Detection Setup
If Activity is selected in Motion Detection Type field, the following parameters are enabled: Relay Output: The unit may be configured to activate a relay output when motion detection is
present. Select either 1, 2, 1+2 (both relays), or None. Link to Event: Selecting Yes in this menu will activate the event record speed when activity detection
is present.
Intrusion Detection Setup
If Intrusion is selected in Motion Detection Type field, the following parameters are enabled: Sensitivity: Rotate the Shuttle to change the motion detection sensitivity, 10 being the most
sensitive. Rejection: Configure the unit’s false alarm rejection feature by selecting Low, Medium, or High.
These settings are based on the number of simultaneously triggered zones and the persistence of motion in a scene. The Low setting is the most sensitive to motion. The Medium setting will filter out most false alarm situations due to sudden luminance changes over the whole scene (clouds passing over). The High setting will filter out sudden luminance changes as well as spurious motion events that do not persist for a number of frames (a bird flying past the lens).
Target Size: This setting is the minimum number of zones (from the 16 x 16 grid) that must be activated simultaneously before it is considered to be valid motion.
Link To Alarm: Select the alarm number that you wish to activate when motion detection is activated.
q Main Menu Motion Detection Setup Active Zones
Use this menu to setup the Active Zones for motion detection. The screen shown below will overlay the current video image allowing for precise activity zone setup. The disabled zones will be tinted. The enabled zones will be clear.
Activity Grid Setup Screen
5
0150-0193C 46 Calibur DVMRe Triplex
‘MENU’ : Exit Activity Setup
‘ENTER’: Save and Exit Activity Setup
‘PAUSE’: Toggle between Enable and Neutral
‘STOP’ : Toggle between Disable and Neutral
‘PLAY FORWARD’: Increase the Sensitivity level
“PLAY REVERSE’: Decrease the Sensitivity level
Play Forward to increase the Sensitivity
Indicate Detection
Titles Display
Camera Disable
Pressing the Function button will bring up the Help screen shown on the next page. This screen will overlay the current video image.
{F}
Function
‘ZOOM’ : Disable/Enable all zones
Button
Sensitivity Scope
Use the sensitivity scope to adjust the motion detection sensitivity for the scene. The sensitivity scope is the bar located near the left-hand corner of the screen.
The black bar raises and lowers to indicate the degree of motion detected. When the black bar reaches the red bar, a motion detection alarm is activated.
Adjusting Motion Detection Sensitivity: Raise and lower the red bar to change the motion detection sensitivity. Use the Play Forward button to increase the sensitivity level and the Play Reverse button to decrease the sensitivity level. The sensitivity level is also displayed as a numeric value.
Play Reverse to decrease the Sensitivity
q Main Menu → Motion Detection → Indicate Detection
Motion Detection may be indicated on-screen by displaying the letter M. Use this menu to turn this feature On or Off.
Detection
ON
3.14 Camera Setup
Use this menu to:
Edit the title for each camera.
Adjust the Automatic Gain Control.
Disable or Enable camera inputs.
Specify cameras as covert (recorded but not displayed).
View the Camera Scope (Histogram)
q Main Menu Camera Setup Camera Titles
Use this menu to:
Specify if the camera titles will be displayed on the monitors. Edit the title for each camera.
0150-0193C 47 Calibur DVMRe Triplex
Camera Titles Camera AGC
Covert Camera Camera Scope
Edit Titles
Titles Display
Titles Display
[CANCEL] [OK]
Monitor B: OFF
Camera titles may be displayed on either monitor. Use this menu to turn this feature On or Off.
Rotate the Jog buttons to navigate and the Shuttle to change the values.
Monitor A:
Edit Titles
Rotate the Shuttle to select the camera whose title you wish to configure, and then press the Enter button. The Camera Title Edit menu will appear.
Camera Title Edit
ON
Camera Title : Camera 01
@ABCDEFGHIJKLMNOPQRSTUVXXYZ[\]^
SEQ key selects character bank ‘1’ key inserts blank character ‘2’ key inserts selected character
1
[CANCEL] [OK]
Camera Title Edit Menu
1. With the camera title selected, press the Enter button. The menu will enter the Edit mode and the
character bank will appear in the center of the menu.
2. Press the Sequence button to select the desired character set.
3. Rotate the Shuttle to navigate the cursor in the camera title.
4. Rotate the Jog to navigate the cursor in the character bank.
5. Press the Number 1 button to insert a blank character or press the Number 2 button to insert the
selected character.
6. When finished editing the title, press the Enter button to exit the edit mode.
7. Save changes and exit the menu: Select [OK], then press the Enter button.
8. Exit the menu without making changes: Press the Menu button, or select [CANCEL], then press
the Enter button.
q Main Menu → Camera Setup AGC
Use the Automatic Gain Control (AGC) to adjust the video input signal level for cameras whose level is outside the normal range. The default gain setting is 100%.
Rotate the Jog to navigate and the Shuttle to change the values.
Save changes and exit the menu: Select [OK], then press the Enter button.
Exit the menu without making changes: Press the Menu button,
or select [CANCEL], then press the Enter button.
0150-0193C 48 Calibur DVMRe Triplex
Signal Gain Setup
Camera 01 Signal Gain 100%
[CANCEL] [OK]
Power Up Disable
Auto Disable Now
Individual Disable
Camera Disable
[CANCEL] [OK]
Camera 03: Disable
Power Up Disable
[CANCEL] [OK]
Camera 02: YES
q Main Menu Camera Setup Camera Disable
Use this menu to:
Enable or Disable cameras individually
Configure the unit to disable cameras automatically at power-up
if video loss is detected.
Automatically disable all inputs detecting videoloss.
Individual Disable
Use this menu to Disable or Enable each camera input
Camera 01: Camera 02: Enable
Disable
individually. Use the Jog to navigate and the Shuttle to change the values. Save changes and exit the menu: Select [OK], then press
the Enter button. Exit the menu without making changes: Press the Menu
Camera 04: Enable : : Camera 16: Enable
button, or select [CANCEL], then press the Enter button.
Power Up Disable
With this feature turned On (Enabled), the unit will automatically detect which inputs are experiencing videoloss at power-up, and disable them.
Disable
Rotate the Jog to navigate and the Shuttle to change the values.
OFF
Auto Disable Now
This feature detects which inputs have video signals and which are experiencing videoloss. When this feature is activated, the unit will automatically disable the inputs experiencing videoloss. The DVMRe Triplex will also re-enable video inputs that were previously disabled if a video input signal is detected.
q Main Menu Camera Setup Covert Camera
This feature removes cameras from all live displays while continuing to record them, so that the users and the public are unaware that the camera is being recorded. Covert cameras are viewable during playback.
Select Yes in this menu to configure a camera as covert. Rotate the Jog to navigate and Shuttle to change the values.
0150-0193C 49 Calibur DVMRe Triplex
Covert Camera
Camera 01:
Camera 03: NO Camera 04: NO : : Camera 16: NO
NO
q Main Menu Camera Setup Camera Scope
Luminance Histogram
Luminance
OFF
Use this menu to view a live luminance histogram of the currently displayed camera.
Luminance Histogram
A Luminance Histogram is a graphical representation of how many times each gray-level value occurs in an image.
Use this feature to analyze and optimize the video input signal.
%L
0
Black
White
3.15 Archive Setup
Data recorded by the unit can be archive to an external archive device.
Use this menu to:
Turn Background Archiving mode Off and On.
Erase the recorded data on a compatible archive device.
q Main Menu → Archive Setup Background Archive
Background Archive: Commands the unit to record data to both the
hard disk and the archive device simultaneously. Select from the following items.
OFF: Turns background archiving Off. ON: Turns background archiving On.
Background Archive
Erase Archive Medium
ON
0150-0193C 50 Calibur DVMRe Triplex
q Main Menu Archive Setup Erase Archive Medium
RS485
POTS Setup
G.711
Use this feature to erase all of the recorded data on an archive device.
With Erase Archive Medium highlighted, press the Enter
Erase all Records. Are you sure?
button. If a compatible archive device is connected, a confirmation box will appear, otherwise no action will occur.
3.16 Audio Setup
Use this menu to enable or disable the audio feature of the Triplex. Select from:
OFF
G.711
3.17 Communications
Use this menu to:
Configure the baud rates and settings for the RS232 ports.
Configure the network address for the RS485 network.
Configure the Ethernet address and networks settings.
Message
YES
OFF
RS232
Ethernet
q Main Menu Communications RS232
Select the Port you wish to configure and press the ENTER button.
Port 1
Port 2
Port 1
Use this menu to:
Enable/Disable POTS and configure the Modem initialization string (POTS Setup).
Baud Rate
Adjust the Baud rate.
POTS Setup
The default modem string (shown below) is for use with Hayes Accura 56k, Diamond Supra Express 56k, and 5686 US Robotics modems in their default conditions. Consult with the modem manual before attempting to make any changes. It is strongly recommended that the modem initialization string only be modified by a qualified technician.
0150-0193C 51 Calibur DVMRe Triplex
POTS Setup
POTS : DISABLE
1200 Baud
2400 Baud
4800 Baud
19200 Baud
38400 Baud
57600 Baud
Modem Init String : AT&F1&K3M0E1Q0V1S0=0&R2&C1&D0&H1
[Default Modem String] [CANCEL] [OK]
@ABCDEFGHIJKLMNOPQRSTUVWXYZ[\]^
SEQ key selects character bank ‘1’ key inserts blank character ‘2’ key inserts selected character
1. With the Modem Init String highlighted, press the Enter button to enter the Edit mode. The character bank will appear in the center of the menu.
2. Press the Sequence button to select the desired character bank.
3. Rotate the Shuttle to navigate the Modem Init String.
4. Rotate the Jog to select a character from the character bank.
5. Use the Number 2 button or rotate the Shuttle to insert the desired character from the character
bank into the Modem Init String and advance to the next character.
6. Use the Number 1 button to insert a blank character.
7. When finished, press the Enter button.
8. To save the changes and reboot, select OK, then press the Enter button. The unit will only reboot
if changes were made to the Modem Init String.
9. To exit the menu without making changes, select Cancel, then press the Enter button. Pressing the Menu button also exits the menu without making changes.
Baud Rate
Use this menu to configure the baud rate for Port 1. Rotate the Jog to select a baud rate from the menu.
Save changes and exit the menu: Press the Enter button. Exit the menu without making changes: Press the Menu button.
9600 Baud
Port 2
The RS232 port 2 is used for Event Generation and ASCII Text Insertion. See Section 7 for the RS232 Protocol required to perform these functions.
0150-0193C 52 Calibur DVMRe Triplex
q Main Menu Communications RS485
Connect several units to a single keyboard, or vice-versa. Up to 32 units (any combination of multiplexers and keyboards) can be networked together. Use this menu to specify the units unique network address.
Save changes and exit the menu: Press the Enter button. Exit the menu without making changes: Press the Menu button.
Network Address
01
q Main Menu Communications Ethernet Settings
An ethernet connection can be used to connect to the unit from a PC for viewing of live or recorded images. Use this menu to configure the Ethernet communications settings. Select from the following:
Ethernet: Select Enable or Disable. IP Address / Subnet Mask / Gateway: Consult with a qualified
Network Administrator or an MIS professional to configure these settings.
3.18 Front Panel Lock
Use this feature to lock the front panel keypad. While locked, the only operational key on the front panel is the Menu button. To unlock the front panel, enter the Installer password and return to this menu.
Highlight the item you wish to select.
Save changes and exit the menu: Press the Enter button. Exit the menu without making changes: Press the Menu button.
3.19 Factory Settings
Ethernet Settings
Ethernet : IP Address : 10. 90.253. 22 Subnet Mask: 255.255. 0. 0 Gateway : 10. 90. 0. 1
Unlock Keyboard
Lock Keyboard
Enable
[CANCEL] [OK]
Return To Factory Defaults
From the Factory Setting menu, press the Enter button. A password box will appear. Enter the Factory Default password. Select OK, then press the Enter button.
The unit will reboot, returning all settings (except the time and date) to the factory defaults. Due to the large size of the hard disk, the reboot may take several minutes.
Factory Default Password
10 and 16-Channel 4-Channel
8 1 1 1
4 1 1 1
Change Language
From the Factory Setting menu, press the Enter button. A password box will appear. Enter the Language password. Select OK, then press the Enter button.
A menu will appear displaying the available language selections. Rotate the Jog to select the desired language.
Save changes and exit the menu: Press the Enter button. Exit the menu without making changes: Press the Menu button.
0150-0193C 53 Calibur DVMRe Triplex
Language Password
10 and 16-Channel 4-Channel
5 4 1 5
1 4 1 4
-
Installer Password
-
Edit Camera Titles
Installer Password
3.20 Passwords
Use this feature to change the Installer, Operator or Ethernet passwords.
Changing the Installer or Operator Passwords
To change the password:
1. Highlight the password you wish to change, then press the Enter button. A password box will appear.
2. Enter the new password using the Number buttons.
3. Highlight OK, then press the Enter button.
4. Re-enter the password.
5. Highlight OK, then press the Enter button. The user will be
prompted, indicating if the password was entered correctly and changed.
The Ethernet Password
The Ethernet Password feature limits access to only those users who access the unit using the password feature of WaveReader versions 2.3 or later. When the unit is first setup, the default is No Password Protection. Meaning, anyone using WaveReader and accessing with an ethernet connection can connect to the unit.
Operator Password Ethernet Password
Password Box
Enter a new Install Password
---
Password Box
Enter a new Ethernet Password
---
Activate The Ethernet Password
1. Enter the new password using the Number buttons.
2. Highlight OK, then press the Enter button.
3. Re-enter the password.
4. Highlight OK, then press the Enter button. The user will be prompted, indicating if the password was
entered correctly and changed.
Deactivate The Ethernet Password
To return the unit to No Ethernet Password Protection, enter the Ethernet Access Reset Password in the password box shown above.
Ethernet Access Reset Password
1 1 1 1
3.21 The QuickInstall Menu
QuickInstall Menu Overview
After installation is complete, it is strongly recommended that, as a minimum, the items in the QuickInstall menu be configured before the unit is used.
All items located in the QuickInstall menu are also found in the Main menu. These items are provided in the separate QuickInstall menu as a convenience for the installer.
Change the time Change the date
Camera Disable Record Quality
Auto Disable Now
0150-0193C 54 Calibur DVMRe Triplex
Use the following table to find detailed information about configuring
Sequencing
specific items from the QuickInstall menu.
QuickInstall Menu Item
Change the time Change the date Edit Camera Titles Camera Disable Record Quality Installer Password Auto Disable Now
Main Menu Time/Date Set Time Main Menu Time/Date Set Date Main Menu Camera Setup Camera Titles Main Menu Camera Setup Camera Disable Main Menu Record Record Quality Main Menu Passwords Installer Password Main Menu Camera Setup Camera Disable
Auto Disable Now
Primary Menu Location
3.22 The Operator Menu
The Operator Menu Overview
The Operator menu is provided so that the user has access to a limited number of menu items. These menu items are primarily monitor display setup options, so that the user may “personalize” the monitor displays during their shifts. Other options include video archive setup and changing the operator password.
None of the items are unique to the Operator menu. All items located in the Operator menu are also found in the Main menu.
Section In
Manual
3.8
3.8
3.14
3.14
3.10
3.20
3.14
Time/Date Display Titles Display Alarm History Archive Setup Operator Password
Use the following table to find detailed information about configuring specific items from the Operator menu.
Operator Menu Item Primary Menu Location
Sequencing Time/Date Display Titles Display
Alarm History Video Archive Setup Operator Password
Main Menu Sequencing Main Menu Time/Date Time/Date Display Main Menu Camera Setup Camera Titles
Title Display Main Menu Alarm Alarm History Main Menu Archive Setup Main Menu Password Operator Password
Section In
Manual
3.9
3.8
3.14
3.11
3.15
3.20
0150-0193C 55 Calibur DVMRe Triplex
About DVMR
OK
3.23 The SystemView Menu
The SystemView Menu Overview
The SystemView menu is provided so that users may quickly view global software and hardware settings.
View Screen 1 View Screen 2 View Screen 3 View Screen 4 View Screen 5 View Screen 6 View Screen 7 View Screen 8
About DVMRe menu: This menu provides information such as model designation, serial number, software version, software date, boot code version hard disk size, IP address, and hardware address (MAC).
Model: Serial Number: Software Version: Software Date: Boot Code Version: Disk Size: IP Address: Hardware Address:
DVMRe-16CT D406-T72-210001 VER 4.08 Oct 15 16:40:18 2002 VER 1.03
163.93 GB
3.18.173.10 BA-BE-C6-7E-FA-CE
View Screens 1 through 8: These menus provide an overview of the units current operating parameters and the menu settings selected by the user or installer. Each View Screen is described in the following tables.
The View Screens
View Screen 1
Alarm Input
Enable/Disable: 1 = Enabled, 0 = Disabled
Normally Open or Normally Closed: 0 = Open, C = Closed
Macro: Macro number if activated
Alarm Action
Freeze: 1 = Freeze, 0 = No Freeze
Cameras: Primary camera in alarm and three associated cameras
Relay: 1, 2, 1+2, or None
View Screen 2
Camera
Enable/Disable: 1 = Enabled, 0 = Disabled
Signal Gain: AGC setting from 1 through 10
Covert Camera: Yes or No
Camera Title
Videoloss Action
Relay 1: 1 = Enabled, 0 = Disabled
Relay 2: 1 = Enabled, 0 = Disabled
Buzzer: 1 = Enabled, 0 = Disabled
0150-0193C 56 Calibur DVMRe Triplex
View Screen 3
Motion Detection
Enable/Disable: 1 = Enabled, 0 = Disabled
Activity or Intrusion Detection: I = Intrusion, A = Activity
Sensitivity: 1 through 10
Relay Output: None, 1, 2, 1+2
Link to Event: Yes or No
Rejection Ratio: High, Medium, or Low
Target Size: 1 through 256
Alarm Camera: 1 through 4, 10 or 16
View Screen 4
Record Rate
Event Camera Settings: T = Timelapse, E = Event, ET = Event and Timelapse
Timelapse Record Rate: In pictures per second (pps).
Event Record Rate: In pictures per second (pps).
Pre Event Duration: 0 to 5 seconds.
Post Event Duration: 0 to 200 seconds.
Acitvity Record Rate: In pictures per second (pps).
Record Quality: High, Medium, or Low.
View Screen 5
Record Timer
DAY: 1-31, Mon, Tue, Wed, Thu, Fri, Sat, Sun, Mon-Fri, Sat-Sun, Mon-Sun
Start: Time (HH:MM)
Stop: Time (HH:MM)
Macro: Macro Number, On or Off
View Screen 6
Time and Date Display A: On or Off.
Time and Date Display B: On or Off.
Time Format
Date Format
Titles Display A: On or Off.
Titles Display B: On or Off.
Master Clock: Yes or No.
Multiscreen Dwell: In seconds.
Full Screen Dwell: In seconds.
Record Mode: No Overwrite, Write Once, or Continuous.
Auto Disable: On or Off.
Indicate Detection: On or Off.
0150-0193C 57 Calibur DVMRe Triplex
View Screen 7
Global Buzzer: On or Off.
Live Alarm Buzzer: On or Off.
Video Loss Buzzer: On or Off.
Playback Buzzer: On or Off.
Relay 1: Normally Open or Normally Closed.
Relay 2: Normally Open or Normally Closed.
Alarm Latch: T = Transparent, L = Latched, TO (020) = Timed Out (Time)
Alarm Record Mode: Interleaved, Exclusive, or No Change.
Full Screen Alarm: Yes or No. This feature is not available on the 4-Channel units.
Global Alarm Record Rate: In pictures per second (pps).
Pre Alarm Duration: In seconds.
Archive Alarm: Enable or Disable.
View Screen 8
Background Archive: On or Off.
Monitor Setup: Single or Dual.
Baud Rate Port 1
Baud Rate Port 2
Network Address
Ethernet: Enable or Disable.
POTS: Enable or Disable.
Language: English, German, or French.
Keyboard Lock: On or Off.
Record Lock: On or Off.
0150-0193C 58 Calibur DVMRe Triplex
4 Alarms
4.1 Alarm Input
Alarm devices are connected via the Alarm PCB on the back panel of the unit (see section 1.7). Each Alarm Input corresponds with the Camera Input of the same number. Alarm input to camera number assignments can be changed on 10 and 16-channel models. See Alarm Action menu (section 3.11).
4.2 Alarm Output
Front Panel Alarm LED: The LED located to the left and above the Alarm button is lit for the duration
of the alarm. Internal Buzzer: The internal buzzer is activated until it is Silenced and Acknowledged. This feature
can be turned off in the menu system (see Buzzer Setup in section 3.11).
Monitor Displays: Discussed below in the On-screen Displays During Alarms section. Output Relays: The alarm output relays are active for the duration of the alarm. This feature is
configured in the menu system (see Alarm Action and Relay Configuration in section 3.11) and can be deactivated.
Macro Activation: Unit can be configured in the menu system to activate a macro when an alarm is detected.
Preset PTZ Camera commands: Unit can be configured in the menu system to send preset commands to specific cameras when an alarm is detected.
Record Rate: Record Rate can be increased by recording at the Alarm Record Rate (see section
3.10) and by Interleaved or Exclusive Recording (see Alarm Record mode in section 3.11).
4.3 Alarm Acknowledge
Pressing the Alarm button acknowledges to the unit that the alarm has been recognized and silences the internal buzzer. This does not clear the alarm condition.
4.4 On-screen Displays During Alarms
10 and 16-Channel Units
Monitor-A in Live Multiscreen Mode
Single Alarm: When a single alarm is received, the unit changes to 4-way
display containing the camera in alarm, and three associated cameras. The three associated cameras are defined as a group in the menu system (see Alarm Action in section 3.11). The top left cameo displays the camera in alarm.
Second Alarm: When a second alarm is received, the unit changes to a 10-way multiscreen, displaying the alarm cameras in the top two cameos. The associated cameras are displayed in the remaining cameos.
Third Alarm: When a third alarm is received, the unit changes to a 9-way multiscreen, displaying the alarm cameras in the top three cameos. The associated cameras are displayed in the remaining cameos.
More than three alarms simultaneously: The unit switches to the maximum multiscreen display, i.e. 16 or 10-way.
4-Way
Single Alarm
10-Way
Second Alarm
9-Way
Third Alarm
0150-0193C 59 Calibur DVMRe Triplex
Other display options include:
LIVE MODE
PLAYBACK MODE
Monitor A
Monitor A
Monitor B
Monitor B
A full screen display of a single camera in alarm, with a sequenced full screen display for additional cameras in alarm. This option is selectable in the menu system (see Full Screen Alarm in section 3.11).
Freeze camera display at the time the alarm was received.
Monitor-B Display During Alarm
Single Alarm: Unit switches to a full screen display of the camera in alarm. Additional Alarms: Unit switches to a sequenced display of all cameras in alarm.
4-Channel Units
Single Alarm: Unit switches to a full screen display of the camera in alarm. Additional Alarms: Unit switches to a sequenced display of all cameras in alarm.
4.5 Alarm Operations During Playback
Live Alarms Displays
Single Alarm: Unit switches to a full screen display of the camera in alarm on Monitor B. Additional Alarms: Unit switches to a sequenced display of all cameras in alarm on Monitor B.
LIVE
LIVE ALARM
A
LIVE
LIVE
LIVE ALARM
FULL
SCREEN
ALARM
PLAY
BACK
LIVE ALARM
PLAY
BACK
LIVE
LIVE ALARM
FULL
SCREEN
ALARM
0150-0193C 60 Calibur DVMRe Triplex
Recorded Alarms
Internal Buzzer: During playback, the internal buzzer is activated until it is silenced and
acknowledged. This feature can be turned off in the menu system (see Playback Buzzer, Buzzer Setup in section 3.11).
Front Panel Alarm LED: The LED located to the left and above the Alarm button is lit for the duration of the alarm.
Monitor-A Multiscreen: Each camera in alarm is indicated on-screen by a flashing red “A” in its cameo. Alarm LED lights to indicate an alarm condition. There is no change in the playback (or Triplex) multiscreen based on playback of recorded alarms.
4.6 Alarm History Box
The Alarm History feature provides a list of the 100 most recent alarms. View the Alarm History Box by accessing the menu system, and selecting Operator Alarm History. The Alarm History Box can also be found under Main Menu Alarm Alarm History. For detailed information about viewing the Alarm History Box see Alarm History in section 3.11.
4.7 Searching For Recorded Alarms
See section 5.
0150-0193C 61 Calibur DVMRe Triplex
Play Back
Search Filters
Operation: Play from Disk
DATE (MM/DD/YY) TIME (HH:MM)
Start Stop Start Stop
01/27/02 01/27/02 20:57 20:59
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
[START SEARCH]
Search Filters
Search Results
Start Date Start Time Days HH MM SS
002 01/21/2002 20:09:10 0 00:00:38
003 01/21/2002 20:10:10 0 01:07:22
004 01/22/2002 20:07:10 0 00:00:07
005 01/23/2002 20:07:10 0 00:08:56
006 01/24/2002 20:07:10 0 00:00:06
007 01/25/2002 20:07:10 0 05:57:31
008 01/26/2002 20:07:10 0 00:46:43
000 01/21/2002 20:07:10 0 04:35:15
Search
Enter
5 Searching
The DVMRe Triplex provides a powerful search interface to access video files stored on the hard disk or an external archive device.
Search Menu Overview
Button
Disk Analysis Screen
Disk Analysis Screen
Disk Analysis Screen
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Alarm Event Activity Videoloss Present Absent Hit SEARCH again to enter Advanced Search Level 1
01/21/2002 20:17:01
Motion Search
Search Button
Motion Search
Last 2hrs Last 8hrs Last day Last 7 days Last 4 weeks Last 12 weeks CustomX
Activity Setup
Activity Setup
Enter
Search Button
Activity Event Alarm Text
Camera
X X X X X X X X X X X X X X X X
[CANCEL]
Enter
Play Back
Search Results
Search Results
001 01/21/2002 20:08:10 0 00:01:55
9 matches found.
‘PLAY REV/FWD’ to page up/down ‘ENTER’ to play event; ‘SEQ’ to repeatedly play event.
Enter
Enter
Search
Button
0150-0193C 62 Calibur DVMRe Triplex
5.1 Disk Analysis Screen
Alarm Event Activity Videoloss Present Absent
Level 1
Disk Time
and Date
Arrow Cursors
Begin by pressing the Search button. The Disk Analysis Screen will appear. This screen shows a graphical representation of the recorded video stored on the internal hard disk.
02/28/2002 20:45:00
Search Button
Disk Analysis Screen
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Hit SEARCH again to enter Advanced Search Level 1
01/21/2002 20:17:01
01/21/2002 20:17:01
at cursor location.
Zoom Level
Rotating the Jog moves the two arrow cursors across the representation of the recorded video. As the cursors move across the screen the corresponding disk time is indicated in the upper right of the screen. The video representations are color-coded by category. Rotating the Shuttle expands (Zooms) the display. The Lowest level (most detail) is indicated on screen with an (L). Pressing the Enter button will start Playback from the cursor location.
5.2 Motion Search
Pressing the Search button a second time will bring up the Motion Search menu. This menu performs a motion search with six preset time parameters and a custom search option. Rotate the Jog to navigate and the Shuttle to select a specific parameter. Selecting the Custom option and pressing the Enter button starts playback and brings up another window with Start/Stop, Time/Date options. These options provide the parameters to focus the search to a specific time period.
0150-0193C 63 Calibur DVMRe Triplex
Motion Search
‘MENU’ : Exit Activity Setup
‘ENTER’: Save and Exit Activity Setup
‘PAUSE’: Toggle between Enable and Neutral
‘STOP’ : Toggle between Disable and Neutral
Button
Last 2hrs Last 8hrs Last day Last 7 days Last 4 weeks Last 12 weeks
X
Custom
Selecting any of the other options and pressing Enter starts playback and displays the Motion Search Setup Screen.
5
This screen overlays the current playback video and allows the user to enable or disable motion detection on the screen within blocks that form a 16 x 16 grid.
Pressing the Function key while in this screen overlays a help screen with all the available commands.
{F}
Function
Pressing Enter upon completion of the activity setup will start the search and launch the Search Results window. See section 5.4 for operating instructions.
‘ZOOM’ : Disable/Enable all zones
0150-0193C 64 Calibur DVMRe Triplex
5.3 Search Filters
3. Copy from Disk to Archive.
4. Copy from Archive to Disk.
XXXXXXXXXXX
Pressing the Search button a third time brings up the Search Filters Menu. Use the Search Filters menu to specify:
The type of operation to be performed: Play from Disk, Play from Archive, Copy from Disk to Archive, and Copy from Archive to Disk.
The Start and Stop date of the search.
The Start and Stop time of the search.
Searching for recorded activity, events, or alarms.
Searching for a text string.
Which cameras to search inclusively or exclusively.
Search Filters
Operation: Play from Disk
DATE (MM/DD/YY) TIME (HH:MM) Start Stop Start Stop 01/27/02 01/27/02 20:57 20:59
Activity Event Alarm Text
Camera 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
X X X X X X X X X X X X X X X X
X X X X X
[CANCEL] [START SEARCH]
The following options are available when an archive device is connected:
1. Play from Disk.
2. Play from Archive.
Hit Camera buttons to select/deselect individual cameras. Use the Zoom button to globally select/deselect cameras to search.
Selecting Search Parameters
1. Rotating the Jog to navigate, highlight the box adjacent to the parameters that you wish to modify.
2. Once in the Parameter Box, use the Shuttle to navigate through the fields and the Jog to change
the values.
3. To activate the parameter, use the Shuttle or the Enter button to place an [X] in the check box.
4. When finished, use the Jog to navigate to another parameter.
5.4 Search Results
Activate Search
From the Search Filters menu, use the Jog to navigate to the Start Search parameter. With the Start Search parameter highlighted, press the Enter button to begin the search operation. When finished
searching, the Search Results window will appear. A maximum of 200 results can be displayed per search.
Follow the directions on-screen to select, archive, playback, etc.
0150-0193C 65 Calibur DVMRe Triplex
Search Results
Start Date Start Time Days HH MM SS
000 01/21/2002 20:07:10 0 04:35:15
001 01/21/2002 20:08:10 0 00:01:55 002 01/21/2002 20:09:10 0 00:00:38 003 01/21/2002 20:10:10 0 01:07:22 004 01/22/2002 20:07:10 0 00:00:07 005 01/23/2002 20:07:10 0 00:08:56 006 01/24/2002 20:07:10 0 00:00:06 007 01/25/2002 20:07:10 0 05:57:31 008 01/26/2002 20:07:10 0 00:46:43
9 matches found.
‘PLAY REV/FWD’ to page up/down ‘ENTER’ to play event; ‘SEQ’ to repeatedly play event.
Some options may be unavailable depending on the type of search performed. These options are not displayed.
When archiving, the unit will not allow the amount of selected data to exceed the amount of space available on the target medium.
Press the Menu button to exit the Search Results window without making a selection. Hitting the Enter button will play the selected search result. Hitting the Enter button again while in playback will cause the next selection from the search list to be
played. Press the Sequence button to repeatedly play the selected event.
0150-0193C 66 Calibur DVMRe Triplex
6 Technical Specifications
General
External Power Supply
12 Volt DC. 60 Watt (5 Amp)
Connector Power Consumption Operating Temperature Range Relative Humidity Range (Non-Condensing) Dimensions Weight
Connections
10/100 Ethernet Port RS232 Port 1 AUX Port RS232 Port 2 Camera Inputs Monitor-A Output (Y/C) Monitor-B Output (Y/C) Monitor-A Output (Composite) Monitor-B Output (Composite)
2.1mm barrel connector, center positive. 35 Watt nominal (single disk). Operating: 0 to 40°C. Storage: -20 to +60°C. Operating: 10% to 80%. Storage: 10% to 95%
17.5 x 14 x 1.7 Inches. 1U, 19 inch rack unit. 9 Lbs.
RJ-45 Connector. DB-9 Male Connector. DB-9 Male Connector. RJ-45 Connector. BNC connectors. Auto Terminating. Color & Mono. 4-pin Mini-DIN Connector. 4-pin Mini-DIN Connector. BNC Connector BNC Connector
RS485 Port SCSI Port Alarm I/O Port
Two Looping RJ-45 Connectors 50 pin, High Density SCSI-2 female connector. Use Supplied DB-25 PCB connector.
Video
Video Signal Input Video Signal Output Input Termination Display Memory Resolution Gray Scale Colors Compression Standard
0150-0193C 67 Calibur DVMRe Triplex
0.5 to 2.0 Volts peak-to-peak with Automatic Gain Control. 1 Volt peak-to-peak into 75-Ohm. 75-Ohm (Auto Terminating) 4 Megabytes Horizontal: 720 Pixels. Vertical: 484 Lines (576 for PAL). 256 levels Y:U:V 4:2:2, 16.8 Million Colors Wavelets
Audio
Audio Input
315mV, 40k Ohms. Unbalanced.
Audio Output
Alarms
Inputs Relay Configuration Record Priority Alarm Status Indicators
Motion Detection
Zones Per Camera Sensitivity Settings Gray Levels Per Zone Motion Detection Status
Output
Part Numbers
Remote Keyboard
315mV, 600 Ohms. Unbalanced.
1 per camera. User programmable as Normally Open or Normally Closed. Interleaved, Exclusive, or No Change. Relay Outputs, On-screen Indicators. Status Retrievable via RS232
port.
256: 16 x 16 grid. 10 levels 256 levels Relay Outputs, Link to Alarms, Link to Events, On-screen Indicators.
Status retrievable via RS232 port.
CBR-KB3, CBR-KB3/J, KTD405. Includes motorized pan, tilt, and zoom controls.
Rack Mount Kit Replacement Manual
CBR-RK6. 1U Height. Part Number: 0110-R601 0150-0193C.
0150-0193C 68 Calibur DVMRe Triplex
7 RS232 Event Generation/Text Insertion Protocol
7.1 Message Structure
The Delimiter byte signals the start of a new message, and has a value of 0xFF. The Class and Command fields identify the type of message. The Data Length is a 16-bit value indicating the number of bytes in the Data portion of
the message. Data Length is sent using Intel byte ordering (Little Endian). The Check Sum byte is the result of ORing all the bytes in the message.
7.2 Message Type
One message is currently supported to store text along with recorded video.
CMD_ADD_TEXT
Class byte is 0x14. Command byte is 0x40. Data Length is the number of data bytes in the message (from 2 to 502). Camera byte indicates the camera associated with the text. The valid range is from
0 to 15.
Event byte usage is described in the following section. String field contains text characters. The string can be from 0 to 500 characters in
length.
Delimiter Class Command Data Length Data Check Sum
0xFF 0x14 0x40 Data Length[0] Data Length[1] Camera Event String[0] String[1] : String[n-1] Check Sum
7.3 Event Field
The two least significant bits are currently used. All other bits should be zero.
A – Event 0x00
If both the start and end bits are clear, the associated text will be stored with the next recorded field for that camera. That cameras record rate will not be changed.
B – Event 0x01
If only the start bit is set, the associated text will be stored with the next recorded field for that camera. This will cause the selected camera, as well as any pre-event fields to be recorded at the Event Record Rate*.
C – Event 0x02
If only the end bit is set, the associated text will be stored with the next recorded field for that camera. This will start the post-event timer** after which, the selected camera will resume recording at the normal record rate*.
MSB 7 LSB 0
0 0 0 0 0 0 End Start
0150-0193C 69 Calibur DVMRe Triplex
D – Event 0x03
If both the start and end bits are set, the associated text will be stored with the next recorded field for that camera. The post-event timer will be started** after which the selected camera will resume recording at the normal record rate*.
*If no alarms are present. **If enabled.
0150-0193C 70 Calibur DVMRe Triplex
8 RS232 Remote Control Protocol
The unit supports two different communication types:
Remote Front Panel Button Emulation
Remote Configuration and Status
8.1 Front Panel Button Emulation
Data Structure
Byte 1: 0xFF Byte 2: 0x55 Byte 3: Front Panel Button Code
Description
Byte 1 and 2 are header bytes. Byte 3 contains the code for a specific front
panel button. The different buttons and their corresponding
codes are as follows. No Button Pressed 0
Record 1 Play 2 Stop 3 Alarm 4 Freeze 5 Zoom 6 Sequence 7 16 Way Multiscreen 8 Camera 1 9 Camera 2 10 Camera 3 11 Camera 4 12 Camera 5 13 Camera 6 14 Camera 7 15 Camera 8 16 Camera 9 17 Camera 10 18 Camera 11 19 Camera 12 20 Camera 13 21 Camera 14 22 Camera 15 23 Camera 16 24 Reserved 25 - 40 Menu 41 Enter 42
Reserved 43 Macro 44 Reserved 45-49 Monitor B 50 Reserved 51-63 Left Arrow 64 Right Arrow 65 Up Arrow 66 Down Arrow 67 Reserved 68-74 Alarm and Sequence 75 Alarm and Camera 1 76 Alarm and Camera 2 77 Alarm and Camera 3 78 Alarm and Camera 4 79 Alarm and Camera 5 80 Alarm and Camera 6 81 Alarm and Camera 7 82 Alarm and Camera 8 83 Alarm and Camera 9 84 Alarm and Camera 10 85 Alarm and Camera 11 86 Alarm and Camera 12 87 Alarm and Camera 13 88 Alarm and Camera 14 89 Alarm and Camera 15 90 Alarm and Camera 16 91 Reserved 92-110 Search 111 Frame Reverse 112 Frame Forward 113 Play Reverse 114 Stop 115 Play Forward 116 Monitor A 130 2 Way Multiscreen 131 4 Way Multiscreen 132 6 Way Multiscreen 133 7 Way Multiscreen 134 9 Way Multiscreen 135 10 Way Multiscreen 136 13 Way Multiscreen 137
0150-0193C 71 Calibur DVMRe Triplex
8.2 Configuration and Status
i) Data structure
Byte 1: 0xFF Byte 2: Command Type
0xAA: (SET) Update DVMRe with data.
0xBB: (GET) Extract data from DVMRe. Byte 3: Data Length (n) Byte 4: Data Type
0x61: Restart DVMRe
0xFE: Send configuration data to DVMRe 0x09: Read Alarm History from DVMRe 0xFF: Read configuration and status data
from DVMRe Byte 5: Data byte 1 Byte 6: Data byte 2 : : Byte x: Data byte n
ii) Sending data to the DVMRe
a) Restart DVMRe Triplex
This command will restart the DVMRe Triplex.
Byte 1: 0xFF Byte 2: 0xAA Byte 3: 0 Byte 4: 0x61
b) Send data to DVMRe Triplex
Configuration data can be sent to the DVMRe Triplex, to change the way it operates. The data is arranged in the form of 16 byte blocks, numbered from 1 to 213. Blocks 182, 183 and 185 are status blocks, and hence cannot be written to. For details about the contents of each block, contact GE-Interlogix and request the Block Data Structure for the DVMRe Triplex.
Byte 1: 0xFF Byte 2: 0xAA Byte 3: 17 Byte 4: 0xFE Byte 5: Block Number
(1-181, 184, 186-213)
Byte 6: data[0] : : : : Byte 21:data[15]
After sending a block or series of blocks, block number 255 must be updated to signal the end of the configuration session. All data bytes for block 255 must be set to 0.
iii) Requesting data from the DVMRe
When a message of type 0xBB is sent to the DVMRe Triplex, it will respond by sending 16 bytes of requested data.
a) Read Alarm History List
Byte 1: 0xFF
Byte 2: 0xBB Byte 3: 0 Byte 4: 0x09
When the "Read Alarm History List" message is received by the DVMRe Triplex, it responds by sending a start byte 0xFF, followed by ASCII strings for every alarm event in its alarm history list, and a stop byte, 0xFF. Each string is formatted as follows:
dd.bmm/ddbhh:mm:ssbaa<CR><LF>
dd: index number (00 - 99) b: space character mm: month (01-12) dd: day (01-31) hh: hours (00-23) mm: minutes (00-59) ss: seconds (00-59) aa: alarm number (01-16) <CR> Carriage return (0x0D) <LF> Line feed (0x0A)
Example: 03. 11/27 22:48:58 15
b) Read data from DVMRe Triplex
Configuration and status data can be read from the DVMRe Triplex. The data is arranged in the form of 16 byte blocks, numbered from 1 to 213. For details about the contents of each block, contact GE-Interlogix and request the Block Data Structure for the DVMRe Triplex.
Byte 1: 0xFF Byte 2: 0xBB Byte 3: 1 Byte 4: 0xFF Byte 5: Block Number 1-213 or 255 if all
blocks are requested.
The DVMRe Triplex responds to the “Read data” request by sending all the requested data bytes consecutively, without any start or stop bytes.
A total of either 16 bytes or 3408 bytes will be transmitted, depending on whether a single block or all the blocks were requested.
0150-0193C 72 Calibur DVMRe Triplex
9 Macro Tables
Photo copy this page and use it to keep a record of the programmed macro functions.
9.1 Macro Functions Table
Macro Number
1
2
3
4
5
6
7
8
9
10
Description
11
12
13
14
15
16
Function + Sequence
0150-0193C 73 Calibur DVMRe Triplex
Daylight Savings Time: Sets clock ahead one hour in April, and back one hour in October.
9.2 Scheduled Macro Table
Event Day Time Macro to Run
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
0150-0193C 74 Calibur DVMRe Triplex
10 Warranty and Service
10.1 Factory Service
Warning: Do not open the top cover or attempt to service the unit, as this may expose
you to dangerous voltages and other hazards. Programmer maintenance of this unit is limited to external cleaning and inspection. Refer all servicing to qualified personnel.
If the unit requires factory service, contact the dealer who supplied the unit to you for the correct procedures on returning the unit to the factory or the nearest factory service center.
If the dealer is not available, contact the manufacturer of the unit as detailed below and request a Return Material Authorization number (RMA). The unit’s serial number must be provided before a RMA number can be issued. Units returned to the factory for service must have freight and insurance prepaid, and must show the RMA number clearly on all shipping documents. The failure symptoms must be clearly described by the operator and enclosed with the unit together with a copy of the original suppliers invoice. Failure to comply with these instructions will delay service of the unit, and may result in the unit not being accepted by the Repair Center.
Factory Address
GE-Interlogix, Kalatel Division
Attention: Repair Center 3197-C Airport Loop Drive Costa Mesa, CA. 92626 United States of America Telephone: 800-343-3358 (7:00 AM to 4:30 PM, Pacific Time) In Oregon: 541-754-9133 Fax: 541-754-7162 (24 hours a day)
For warranty information, see the following page.
0150-0193C 75 Calibur DVMRe Triplex
10.2 Warranty and Return Information
GE-Interlogix warrants all of its equipment for three years from the date of purchase. This warranty covers any defects in materials and workmanship. Equipment failures that are due to improper installation, modification, abuse, or acts of nature will not be covered by this warranty. The repair department will evaluate all equipment returned for repair to determine warranty coverage. The Tech Support Manager will resolve any questions that may arise during evaluation to make a final determination.
Note: The three-year warranty does not apply to the following products:
MobileView® and the monitor CRT, which carry a 12-month warranty from the date of purchase.
The warranty specifically covers any defects in material and workmanship and does not cover equipment that has been abused, damaged, or modified.
For all warranty repairs, GE-Interlogix will cover all costs, including parts, labor, and shipping. Repaired equipment will be returned via the same method of shipment in which it was received. If a customer requests a faster return shipment, the difference will be charged.
For all non-warranty repairs, the customer will be billed for parts, labor, and shipping. Labor will be billed in half-hour increments.
Note: Customers requesting an estimate prior to repair will be notified by phone. If they cannot be reached, they will be notified by fax. If we are unable to reach the contact person for repair authorization after one phone attempt and two fax attempts, the equipment will be returned without being repaired. We will hold equipment no longer than two weeks.
Advance Replacement Policy
When an advance replacement is required, we will send the customer replacement equipment from our stock and receive the returned product in exchange. The received equipment will be evaluated and the repair department will determine whether it is a warranty replacement. If it is non-warranty, see our repair policy above for details. The following guidelines will be used for all advance replacements:
Fewer than 45 days from purchase, GE-Interlogix will replace the product with new equipment.
From 45 days to 1 year from purchase, GE-Interlogix will replace the product with refurbished
equipment.
From 1 year to 3 years from purchase, the product must be sent in for repair. Advance replacements will be sent for a fee of $100.
If you have questions about this policy, please contact GE-Interlogix Kalatel Division’s RMA Department at 800-469-1676.
0150-0193C 76 Calibur DVMRe Triplex
0150-0193C
Loading...