GDI XC300 Owner's Manual

XC300
VDSL Network Extender
Owners Manual
Warranty
In the event of malfunction or other indications of failure attributed directly to faulty workmanship and/or materials, GDI Communications LLC will, at its option, repair or replace the defective products or components to whatever extent it shall deem necessary to restore the product or components to proper operating condition, provided the consumer purchaser sends with the defective product proof of the date of purchase of the product. Please note that GDI Communications LLC may replace the defective product with a new or re manufactured functionally equivalent product of equal value at the option of GDI Communications LLC.
The customer shall be solely responsible for the failure of any GDI Communications LLC computer product, or component thereof, resulting from accident, abuse, or misapplication of the product, and GDI Communications LLC assumes no liability as a consequence of such events under the terms of this Warranty.
GDI Communications LLC does not warrant the merchantability or fitness of this product for any particular purpose. This limited warranty is in lieu of any and all other warranties, expressed or implied.
GDI Communications LLC's liability shall not exceed the price of the defective individual product, which is the basis for claim. In no event will GDI Communications LLC be liable for direct, indirect, incidental, or consequential damages resulting from any defect in the product or in this manual, even if they have been advised of the possibility of such damages. In no event shall GDI Communications LLC be liable for any loss of profits, loss of equipment or facilities, or the loss of programs or data, or the cost of recovering or reproducing the program or data. Some states do not allow the exclusions or limitation of implied warranties or liability for incidental or consequential damages, so the above limitations or exclusion may not apply to you.
2
TABLE OF CONTENTS
GENERAL INFORMATION ………………………………………………………….4
FEATURES………………………………………………………………………….4
APPLICATIONS........................................................................……………….5
INSTALLATION………………………………………………………………………..7
CONNECTING TO THE VDSL LINE INTERFACE……………………………..8 CONNECTING THE LAN (ETHERNET) INTERFACE ………………………...9 CONNECTING THE TELEPHONE (POTS/ISDN) LINE ……………………...11
CONNECTING POWER ……………………………………………………….....11
OPERATION...............................................................................………………..12
POWER UP ...........................................................................………………..12
FRONT PANEL LED STATUS MONITORS ......................... ………………..12
CUSTOMER SERVICE...............................................................………………..14
SERVICE AND UNRESOLVED PROBLEMS........................………………..14
APPENDIX A ……………………………………………………………………….....15
SPECIFICATIONS..................................................................………………..15
APPENDIX B .............................................................................………………..17
FACTORY REPLACEMENT PARTS AND ACCESSORIES ………………..17
APPENDIX C .............................................................................………………..18
INTERFACE PIN ASSIGNMENT ..........................................………………..18
3
GENERAL INFORMATION
Thank you for purchasing this GDI Communications LLC product. The XC300 is the perfect way to connect disparate Local Area Networks (LAN). There is no special wiring or special networking knowledge required. Using inexpensive, twisted copper pair wire the XC300 allows you to connect LANs that are separated by up to 4000ft, breaking the 300ft Ethernet barrier. The XC300 provides reliable high-speed data communication in the harshest operating environments. It can operate in uncontrolled environments such as remote terminals or curb side distribution vaults.
Designed to operate in the harshest environments the XC300 has an operating temperature range of -40°C to +65°C, in non-condensing humidity of up to 95%. It can be set up at altitudes of up to 10,000 feet.
The XC300NT and XC300LT work together to create a transparent extension between two Ethernet LANs. POTS/ISDN calls can be made over the VDSL link without interfering with the data.
This manual has been designed to enable you to install your XC300 extender by following the step-by-step installation procedure. Follow the step-by-step installation instructions outlined in Section titled - Installation.
FEATURES
Easy to install standalone VDSL modems—no configuration required
Environmentally hardened for operation in harsh environments
Auto-sensing full or half-duplex Ethernet
Auto-sensing 10/100 operation
Extends network connections up to 4,000 ft (1,219 m) over 2-wire 24-AWG
unconditioned lines
.7 to 26 Mbps symmetric and asymmetric line rate
Internal POTS/ISDN splitter on board
Transparent operation
LED indicators for Power, Ethernet Link & Activity, VDSL Sync
Surge suppression up to 20 kA
Available in rack-mount or standalone configurations
4
APPLICATIONS
The GDI Communications LLC XC300 set provides high-speed LAN connections between Ethernet LANs, remote PC’s, or any other network enabled 10/100BaseT/TX device. Operating in pairs with an XC300NT located at one end of the LAN extension and an XC300LT at the other end. The data is passed transparently through the XC300 such that the remote LAN appears to be co-located with local network. Figure 1 shows a typical point-to-point application.
The XC300 is well suited to surveillance applications where cameras with digital output are placed in strategic locations to observe any activity within view of the camera. The information from the camera can be transmitted to a central collection point up to 4000 ft away from the camera over inexpensive copper wire. Having the ability to pass voice communications simultaneously with the high-speed data allows camera positioning information to be sent without interfering with the data signal. Figure 2 shows a camera application
5
The XC300 is ideal for building riser applications where distribution of high-speed data communications in a multi-story building is required. Ordinary communications equipment is inefficient in this high noise environment. The alternative is to use fiber optic cable that is expensive; the end-to-end equipment is also expensiv e. The XC300 is well suited for this environment. Designed with robust VDSL technology the XC300 can deliver reliable high-speed communications throughout the multi-story building at a fraction of the cost of the fiber optic solution.
6
Loading...
+ 13 hidden pages