TABLE of CONTENTS
GENERAL DECRIPTION……………………………………………..4
SPECIFICATIONS…………………………………………………….4
INSTALLATION………………………………………………………5
AT COMMAND SET …………………………………………………7
TABLES
DB-9 PIN-OUT………………………………………………….……5
RJ11 PIN-OUT………………………………………………….…….5
170 CONNECTION CHART…………………………………………6
SM560SAMAN
SM560SA Manual 4
DESCRIPTION
The SM560SA is a 56 Kbps dial-up Modem in a standalone case. It is completely compatible with other V.34 AT command set Modems and is designed for traffic control environments. The SM560SA has a built in power supply and plugs into a standard outlet. The SM560SA-12 connects to a 12VDC supply. The Black wire from the cord is connected to +12V and the white wire is connected to Ground. The SM560SA comes standard with an RS-232 port that connects to a Computer or Traffic controller through a DB-9 (female) connector on the back panel. The phone line connects to the SM560SA through a standard RJ-11 connector. The SM560SA can not be used with leased lines. A second RJ-11 connector can be used for a phone connection.
The SM560SA can operate at 56 Kbps and automatically fall back all the way down to 300 baud. The Modem speed can also be set using the AT commands if wanted (see AT Command listing). The serial port has a maximum speed of 115.2 Kbps and is RS­232 and V.24 compatible. An RS-485 option is also available using the same DB­9 connector.
A speaker is included internal to the Modem so that call progress can be heard. The speaker is controlled through standard AT Commands. Front panel LEDs show the status of the Modem. The SM560SA has Auto Answer, Auto Dial, and tone or pulse dialing. A front panel switch allows you to set DTR active all the time if DTR is not available. Front panel dip switches also allow you to invert the RS-485 data and control signals if that option is installed.
SPECIFICATIONS
ENVIRONMENTAL
Temperature Range……..-37° to +74° C Humidity ..….5 to 95% non-Condensing
POWER
Voltage………..90 to 130 VAC or 189 to 260 VAC
Frequency………47 to 63 Hz
Power…………..6 Watts Max
+12 Volt version….12 VDC @ 0.5A
PHYSICAL
5.7”W x 8.5”D x 1.5” H
Weight……………~3 lbs.
MODEM
Modulation……..Quadrature Amp. Mod.
Compatibility: Modem…………ITU V.90, V.34 and
Rockwell V.FC Interface………..ITU V.24/V.28, EIA-232, and EIA-485
Data Throughput…..115.2 Kbps
Data Rates……56Kbps, 33.6Kbps,
31.3Kbps,
28.8Kbps, 26.4Kbps,
24.0Kbps, 21.6Kbps,
19.2Kbps, 16.8Kbps,
14.4Kbps, 12.0Kbps,
SM560SAMAN
SM560SA Manual 5
9.6Kbps, 7.2Kbps,
4.8Kbps, 2.4Kbps,
1.2K baud, 300 baud. The Modem will automatically select the best operating speed. Speeds are ±0.01%.
Specifications: V.90, 56Kflex, V.34,
V.32 bis, V.32,V.22 bis, V.22A/B, V.23, V.21, Bell 212, Bell 103, V.33, V.17, V.29, V.27 ter, V.21 Channel 2
Error Correction….V.42 LAPM, MNP2-4, MNP 10 Data Compression…V.42 bis, MNP 5
Loop Tests….. ITU V.54 loop2 (RDL) and Loop 3 (LAL)
Transmit and Receive Frequencies:
Data Carrier…….1800 ± 0.5 Hz Calling Tone……1300 ± 10 Hz Answering Tone…2100 ± 15 Hz
Receiver Freq. Tol…….±14 Hz
Receiver Performance
S/N Ratio…………..-26 dB Dynamic Range……-12 dBm to –42 dBm
Transmit Level
Fixed at –11 ±2 dB
Ring detect Sensitivity…. 38 VRMS
LINE INTERFACE
Ring Equiv. Number….…1 Bel
Terminating Imped………600 Ohm
Return Loss… Better than 14 dB between
200 and 4000 Hz
DB-9 PIN-OUT
Pin No. EIA-232 EIA-485
1 DCD (out) TXD+ 2 RXD (out) TXD­3 TXD (in) RXD+ 4 DTR (in) RXD­5 GND GND 6 DSR (out) RTS+ 7 RTS (in) RTS­8 CTS (out) CTS+ 9 RI (out) CTS-
INDICATORS
POWER, TXD, RXD, DTR, DSR (OH), DCD, RI.
Th SM560SA can store 2 user profiles and 4 phone numbers. The numbers can have up to 32 digits.
INSTALLATION
The SM560SA comes from the factory set up for 90 to 130 VAC. If 180 to 260 VAC operation is required, the Zero Ohm jumpers labeled “110VAC” (R8 and R9) should be removed and the Zero Ohm Jumper labeled “220VAC” (R10) installed. These jumpers are located between the transformer and the fuse on the PC Board.
The SM560SA-12 connects to a 12 Volt DC supply rated at least to 0.5A. The Black wire connects to +12V and the white wire connects to Ground. The green wire is Chassis Gnd.
SM560SAMAN
SM560SA Manual 6
The Phone line is connected to the RJ11 connector on the back panel labeled “LINE”. An exterior phone can be connected to the RJ11 labeled “PHONE”. The RJ11 connectors are connected in parallel so do not use the phone while the modem is being used.
RJ11 PIN-OUT
2 TIP 3 RING
The DB-9 connector is pinned out so that a one-to-one cable is needed to connect to most computers. Since most computers use a DB-9 connector with male pins, the cable will need to have one female and one male connector on it.
A special cable will be needed if you have the RS-485 option since there is no standard pin-out for RS-485 with this connector. The DB-9 is pinned out according to the way CALTRANS has defined it on the 2070-7.
The connection chart for a 170 type controller is shown below:
170 Connection Chart
Function DB-9 170 C2,20 TXD 3 K RXD 2 L RTS 7 J CTS 8 M DCD 1 H GND 5 N
As can be seen from the Chart, the 170 doesn’t use DTR and DSR. DTR can be set up to be ignored by the Modem with an AT command. DTR can be permanently
asserted with the front panel switch if you don’t want to use the AT command.
485 OPTION
The SM560SA has the 120-Ohm termination resistors built into the unit on the input lines (TXD and RTS). This Modem is not designed to be used in an RS-485 Multi-drop system.
The polarity of theRS-485 signals can be inverted if needed by two front panel dip switches. The Switch labeled “DATA” will invert the TXD and RXD signals and the Switch labeled “CTR” will invert the RTS and CTS signals. These Switches have no affect on RS-232 operation.
Indicators
The Indicators on the front panel give the status of the SM560SA.
POWER………Indicates that the Power Supply is operating.
TXD…………Indicates that data is being Transmitted
RXD………….Indicates that data is being Received
DTR……….. Indicates that Data terminal Ready is true.
DSR (OH)…..Indicates that Data SET Ready is true. It is also An indicator of the OFF Hook condition.
DCD…………Indicates that the modem Is detecting a carrier.
RI……………Indicates that the Modem is Receiving a Ring signal.
SM560SAMAN
SM560SA Manual 7
There are no adjustments or user selectable features inside the Modem. There is no preventative maintenance required or anything that needs to be adjusted for the life of the product.
The following pages contain a summary of the AT Commands and “S” Registers that the SM560SA responds to. The factory default settings are also shown. A complete definition of the AT commands is too large for this Manual (174 pages). If one is required, a PDF file (450K) can be sent electronically to you.
SM560SAMAN
SM560SA Manual 8
BILL OF MATERIAL
FOR THE
SM560SA
RS-232 VERSION
Item PART
NUMBER
1 PCB-336SA 1 PC Board for the Sm336SA Rev. B 1 2 FP-560SA 1 Front panel w/silkscreen 2 3 BP-560SA 1 Back panel w/silkscreen 3 4 P/CORD-18/3B 1 Power cord, 18 AWG 4 5 SR-1150 1 Strain Relief, Power Cord, Heyco 5 6 LANSING/TOP 1 Lansing Top 6 7 LANSING/BAS
E
8 LANSING/BEZ
L
9 LANSING38695 4 Screw, 4-40 10 LF-3A/G- ½ A 1 Fuse, ½ A Slow Blow 11 Box-12X9X3 1 Shipping Box 9
11A TYWRAP-
3.9WH
12 V.90/56-MMC 1 SocketModem Conexant 56k V.90, K-
13 74HC-86 1 EX-OR Gate, quad, U6 14 14C88 1 RS-232 Driver, Quad, CMOS U7 15 00386 1 Audio Amp, LM386CN U5 16 MAX-232 1 RS-232 Rec., Driver, 5V U3 17 LT-1129CT-5 1 Regulator, 5V, LOH, w/Shut off, TO-
18 01233-5 1 Voltage Monitor DS1233-5, TO92 U10
19 2N7000 7 Transistor, 2N7000, MOSFET Q1,7 20 1N5233 1 Zener, 1N5233, 5.1V Z3 21 1N4004 2 Diode, 1N4004, 1 Amp, 400V D1,2 22 SA26A 1 Tranzorb, 26V Z2 23 V275/350-S 1 SIDACTOR, Teccor P3100BA70,
24 LED-CR 7 LED, RED, Clear Lens DS1,7
Qty DESCRIPTION REFERENCE
1 Lansing Base 7
1 Lansing Bezel 8
2 Ty-wraps 4” for tying down U9 U9
U9
flex
U1
220
Z1
310V
SM560SAMAN
SM560SA Manual 9
Item PART
Qty DESCRIPTION REFERENCE
NUMBER
25 V150LA10 3 MOV, 150V 50J MOV1,2,3 26 102K1000-CDR 2 Capacitor, 1000pF, 1000V, Ceramic
C22,23
disc 27 473M050-DCR 1 Capacitor, 0.047uF, 50V, ceramic C13 28 104K050-DCR 15 Capacitor, 0.1uF, 50V, ceramic C3-6,8-12,14-
16,18,21,24 29 106K025-TTR 3 Capacitor, 10.0uF, 25V Tantalum C19,20,25 30 107M025-AER 1 Capacitor, 100 uF, 25V Electrolytic C7 31 227M035-AER 1 Capacitor, 220 uF, 35V Electrolytic C17 32 108M025-AER 2 Capacitor, 1000 uF, 25V Electrolytic C1,2 33 34 35 02505-000 3 Resistor, 0 Ohms R8,9,12 (opt
R14) 36 02505-100 1 Resistor, 10 Ohms, ¼ W, 5% R13 37 02501-1001 10 Resistor, 1.0 K, ¼ W. 1% R1-7,11,15,16 38 02501-3011 1 Resistor, 3.01 K, ¼ W, 1% R17 39 02501-4751 3 Resistor, 4.75 K, ¼ W, 1% R20,21,23 40 02501-2321 1 Resistor, 2.32 K, ¼ W, 1% R22 41 PDT-2 1 Switch, push button SW2 42 SPST—3SA 1 Switch, dip, 3 position side actuated SW1 43 PH3TB-MKDS 1 Terminal Block, 3 position, Phoenix J4 44 RJ11C-RA/PC 2 RJ-11 Phone Jack, PC mount J1,2 45 9DSC-FRA/PC 1 Connector, DB-9, Female, PC mount J3 46 47 LP20-300B7 1 Transformer, 20V, PC mount T1 48 FERBEAD-85A 8 Ferrite Bead, TDK BF45-4001 L2-9 49 FERBEAD-
400W
1 Wound Ferrite Bead, Fair-Rite
2961666681
L1
50 51 10SIL-TH/SKT 2 Socket, 10 Position SIP, SAMTEC A9 52 IC-SKT4 2 Socket, 4 Position SIP, SAMTEC A9 53 LFH-HLDR/PC 1 Fuse Holder, Littlefuse F1 54 LFH-K/3AG 1 Fuse Holder Casing F1 55 M/SPKR-SQ/2 1 Speaker SPKR1 56 MS3-48X3/8PP 2 Screw, 3-48 3/8” SPKR1 57 HN3-48SS/S 2 Nut, 3-38 SPKR1 58 H/SINK-FIN 1 Heatsink, TO-220 HS1 59 MS4-40X3/8P 1 Screw, 4-40 X 3/8” HS1 60 HN4-40Z/M 1 Nut, 4-40 HS1 61 CL/SPRAY A/R Conformal Coating 10
SM560SAMAN
SM560SA Manual 10
Item PART
Qty DESCRIPTION REFERENCE
NUMBER
62 A/R Heatsink compound HS1
SM560SAMAN
SM560SA Manual 11
GDI COMMUNICATIONS, LLC
280 I-80 West Exit 1
PO Box 1330
VERDI, NEVADA 89439
775-345-8000 FAX: 775-345-8010
www.sgdi.com
SM560SAMAN
Loading...