GDH Eco Air Split series Installation And Operating Instructions Manual

Installation and Operating Instructions
Table of contents
Safty instructions Page 3
Components Page 4
Connection Indoor and Outdoor Unit Page 5
House Installation Page 7 Hydraulic Connection Page 8 Dimensions Page 9 Electrical Wire Diagram Page 10
Installation Procedure Page 11 Controller Page 12 Controller – setup – operation Page 13 Controller – setup – timer Page 14
Parameters definations Page 15 Parameters definations and settings Page 16 Error list Page 17
Maintenance Page 18
GDH-50Eco Air Split Technical data – characteristic curve Page 19 Technical data Page 20
GDH-70Eco Air Split Technical data – characteristic curve Page 21 Technical data Page 22
GDH-120Eco Air Split Technical data – characteristic curve Page 23 Technical data Page 24
EC Declaration of Conformity Page 25
Safety instructions
This unit should not be installed in any area where flammable liquids or vapors may be present. Do not store or use gasoline or other combustible materials or liquids near or adjacent to this water heater.
Do not use this unit if it has been dropped or damaged in any way.
Check the rating plate on the unit before installation to make certain the
voltage shown is the same as the electricity supply to the water heater.
The unit must be connected only to a properly grounded electrical supply. Do not fail to properly ground the unit.
This unit should only be serviced by qualified service personnel.
Always shut off electric power before making unit connections or removing
any panels and be extremely careful to avoid injury.
Components may have sharp edges or protrusions which can cut you.
Tubing and compressor contain high pressure refrigerant and they should not
be exposed to high temperature or be punctured.
Water temperature over 52 °C (125 °f) can cause severe burns or death from scalding. Feel the water before bathing or showering. Children, disabled, and elderly are at highest risk of being scalded.
Tampering with the thermostat, heater, elements or electrical connections is dangerous and may result in serious injury. Only properly trained, qualified service personnel should service these components. Do not attempt to modify or change this water heater in any way.
3
Components
4
Connection Indoor and Outdoor Unit
5
House Installation
7
Hydraulic Connection
8
Dimensions
The Heat Pump Water Heater should never be stored or installed on its side. Upright transportation is recommended. If it becomes necessary to transport the water heater on its side, the manufacturer recommends that the unit be in the upright position for a minimum of two hours prior to operation. Failure to follow these instructions may result in damage to the water heater.
After removing the unit from the crate/carton, immediately remove the panels and inspect for any damage that might have occurred during shipment. Report concealed damage immediately to the transportation company and request inspection. The electric power source must be the same voltage and phase as shown on the rating plate. Line and low voltage wiring must be done in accordance with local codes or the national electric code.
9
Electrical Wire Diagram
10
Installation Procedure
The heat pump should be mounted level on a vibration absorbing pad slightly larger
than the base to provide isolation between the unit and floor
Connect the heat pump with your water pipes (DN25) – inlet and outlet water
Install a circulation water pump direct after the outlet water
Connect the power wire on 220 Volt. Do not forget to connect on earth
Connect the controller panel with the telephone wire
Put the water tank sensor into your water tank
If the heat pump installed into south side, please use the second outdoor
temperature sensor. Change the existent outdoor temperature sensor. The new one is to install and to put it into the north side. The outdoor temperature sensor is not to install into the sun.
Compressor Time Delay: Be aware there is a 3 minute time delay before the compressor will start once the unit is turned on or whenever it restarts.
Connection pipe size:
DN25 = GDH70 Air Split – Inside Unit
11
Controller
1 On / Off 11 Latest water temperature / Error Code
2 Up 12 Not available
3 Down 13 Return water
4 Setting enter 14 Fan working
5 Timer 15 Circulate water pump working
6 Not available 16 Cooling mode
7 Time 17 Heating mode
8 Timer on / off 18 Not available
9 Locker 19 Electric assistant heater working
10 Water temperature 20 Defrosting
21 Set water temperature
12
Controller – setup – operation
1. Press „power“
2. Setting the water temperature by „up“ or „down“ keys
3. Setting the inlet and outlet temperature by „setting“ key – press one time – than please press the „setting“ key for 8 seconds.
Press „settings“ again and again until you have choose the following parameters:
Please change the settings L3 (oulet water temperature) and L6 (inlet water temperature) into your requirements.
4. If you have set up your requirements, please press „power“ to start the heat pump.
5. You can change into heating (sun) and cooling (snow flake) mode by press the key „up“ for 8 seconds.
6. Your heat pump is set up and start to work – the compressor start by a delay of about 3 minutes.
Attention:
If your controller locked you have to press the „power“ key for 8 seconds. The controller lock by itself if you do not use it.
It is not nessescary to change other parameters – only L3 and L6 for the outlet and inlet water temperature. Also the water temperature in the display by „up“ and „down“ keys.
13
Controller – setup - timer
1. Press „timer“ for 11 seconds. You hear after 3 seconds the first buzzer and after 8 seconds the second buzzer
2. Press „up“ or „down“ keys to set up the time. You confirm by press „setting“
You can set up two different timers.
Example:
Timer 01
Start 08.00 Stop 13.00
Timer 02
Start 15.00 Stop 24.00
Set up the two timers:
1. Press „timer“ one time
2. Press „up“ or „down“ keys to set up the timer. You confirm by press „setting“
14
Parameter definations
15
SHOW: touch function – inquiry – touch again – quit.
Code
Parameter
A1 / B1
Fan coil temperature
A2 / B2
Return gas temperature
A3 / B3
Exhaust temperature
A4 / B4
Enviroment temperature
A5 / B5
Outlet water temperature
A6 / B6
Return water temperature
A7 / B7
00
A8 / B8
Compressor current
A9 / B9
Electric expansion valve angle
This parameters show the settings of L1 – L7
Parameter definations and settings
16
SETTINGS: Touch function over 3 seconds – hear a sound – off your hand – enter your settings.
Code
Parameter
Range
Standard setting
/ / /
Water tank temperature setting
20 °C – 60 °C
35 °C / 45 °C / 50 °C / 55 °C
L1
Dummy temperature
0 °C – 15 °C
00 °C
L2
Compressor start & set temperature
3 °C – 18 °C
05 °C
L3
Set outlet water temperature
35 °C – 99 °C
35 °C / 45 °C / 50 °C / 55 °C
L4
Maximal water tank temperature
30 °C – 99 °C
60 °C
L5
Electric start temperature
0 °C – 35 °C
00 °C
(0 °C mean no electric assistant heater)
L6
Return water temperture
30 °C – 65 °C
30 °C / 40 °C / 45 °C / 50 °C
L7
Supplement water temperature
20 °C – 60 °C
20 °C
(20 °C mean no supplemmet)
L8
Compressor current
0 – 48A
0
H1
Defrosting period
20 min. – 99 min.
35 min.
H2
Permission temperature for defrosting
-15 °C – 1 °C
-01 °C
H3
Defrosting time
5 – 20 min.
10 min.
H4
Defrosting temperature
1 °C – 40 °C
20 °C
P1
Electric expansion valve adjust period
20 – 180 sec.
30 sec.
P2
Difference temperature between A1 and A2
-8 °C – 15 °C
00 °C
P3
Pemission for exhaust temperature protection
70 °C – 135 °C
95 °C
P4
Electric expansion valve open angel
when defrosting
6 – 55 degree
50 degree
P5
Electric expansion valve minimal open angel
6 – 30degree
15 degree
Error list
17
Code
Reason
01E
Mistake on phase
02E
Missing phase
03E
Water flow switch
05E
Water pump – pressure or connection
06E
Low pressure – leckage/refrigerant/dirty
07E
-
08E
-
09E
Communicate
11E
Limit time pin code
12E
High exhaust temperature /
13E
-
15E
Water tank sensor broken
16E
Fan coil sensor broken
17E
-
18E
Exhaust sensor broken
19E
-
21E
Enviroment sensor broken
22E
Return water sensor broken
25E
Water level switch broken
27E
Outlet water sensor broken
28E
Return gas sensor broken
29E
Water pressure sensor broken
Maintenance
Please clean the heat pump all the time. The evaporator has to be free of leaves and other things. If you clean the heat pump please do it by off mode.
After the European enviroments requirements proof the the heat pump for any leckage by a professional.
We recommend you to maintenance the heat pump by a professional minimum one time per year. It is to proof after gas leckage, oil level of compressor and low/high pressure.
Check list
Leckage of refrigerant
Oil level of compressor (please change it regulary by professional)
Low and high pressure
Electric wires
18
19
Technical Data GDH50-Air-Split
Outlet water max. temp. (°C) A10/W35 7,2 kW / COP 3,8 Outlet water max. temp. (°C) A7/W35 6,3 kW / COP 3,5 Outlet water max. temp. (°C) A2/W35 5,2 kW / COP 3,0 Outlet water max. temp. (°C) A-7/W35 4,1 kW / COP 2,3
Starting current 18 A Operating current 17,2 A Operating voltage 220V 1NAC 50 Hz Compressor Scroll Max. water flow 2.500 l/h Fuse 1 x C 25 A Refrigerant quantity (R407c) 2,4 kg
Outdoor Unit High 900 mm Width 950 mm Depth 420 mm Weight 45 kg Sound level (distance 1 m) 54 dB
Indoor Unit High 500 mm Width 450 mm Depth 280 mm Weight 25 kg Sound level (distance 1 m) 26 dB
Subject to modification. Images for demonstration.
20
21
Technical Data GDH70-Air-Split
Outlet water max. temp. (°C) A10/W35 9,2 kW / COP 3,8 Outlet water max. temp. (°C) A7/W35 8,5 kW / COP 3,5 Outlet water max. temp. (°C) A2/W35 7,1 kW / COP 3,0 Outlet water max. temp. (°C) A-7/W35 6,3 kW / COP 2,3
Starting current 20 A Operating current 19,2 A Operating voltage 220V 1NAC 50 Hz Compressor Scroll Max. water flow 2.500 l/h Fuse 1 x C 25 A Refrigerant quantity (R407c) 2,9 kg
Outdoor Unit High 900 mm Width 950 mm Depth 420 mm Weight 55 kg Sound level (distance 1 m) 54 dB
Indoor Unit High 500 mm Width 450 mm Depth 280 mm Weight 28 kg Sound level (distance 1 m) 26 dB
Subject to modification. Images for demonstration.
22
23
Technical Data GDH120-Air-Split
Outlet water max. temp. (°C) A10/W35 15,9 kW / COP 3,6 Outlet water max. temp. (°C) A7/W35 14,8 kW / COP 3,3 Outlet water max. temp. (°C) A2/W35 12,1 kW / COP 3,0 Outlet water max. temp. (°C) A-7/W35 9,7 kW / COP 2,2
Starting current 22 A Operating current 20,2 A Operating voltage 220V 1NAC 50 Hz Compressor Scroll Max. water flow 2.500 l/h Fuse 1 x C 25 A Refrigerant quantity (R407c) 3,2 kg
Outdoor Unit High 900 mm Width 950 mm Depth 420 mm Weight 55 kg Sound level (distance 1 m) 54 dB
Indoor Unit High 1.400 mm Width 950 mm Depth 420 mm Weight 28 kg Sound level (distance 1 m) 26 dB
Subject to modification. Images for demonstration.
24
EC Declaration of Conformity
The undersigned GDH Energy Co., Ltd.
No. 340 Dongjiang Road, Zhongye Building, Free Trade Zone, GETDD, 510730 Guangzhou, China
hereby confirm that the design and construction of the product(s) listes below, in the version(s) placed on the market by us, conform to the relevant requirements of the applicable EC directives.
This declaration becomes invalidated if any modifications are made to product(s) without our prior authorization.
Designation EC Directives Air-to-water heat pumps EC Low Voltage Directive for outdoor installation, containing R407c
EC EMC Directive Pressure Equipment Directive
Typ(e): Harmonized EB Standards: GDH70 Air Split
EN 255:1997 EN 378:2000 DIN 8901
DIN EN 60335-1 (VDE 0700 T1):2005-07 EN603351:2002+A1:2004+A1:2004 DIN EN 60335-2 (VDE 0700 T40):2004-03 EN 60335-2-40:2003 DIN EN 55014-1 (VDE 0875 T14-1):2003-09 EN 55014-1:2000+A1:2001+A2:2002 DIN EN 55014-2 (VDE 0875 T14-2):2002-08 EN 55014-2:1997+A1:2001 DIN EN 61000-3-2 (VDE 0838 T2):2001-12 EN 61000-3-2:2000 DIN EN 61000-3-3 (VDE 0838 T3):2002-05 EN 61000-3-3:1995+Corr.: 1997+A1:2001
National Directives
VBG20 DruckbehV DIN 8901 DIN 8975 SVTI
GDH Energy Co., Ltd. Guangzhou, China
21