Gaymar ATW8000, ATW5000, ATM800, ATM500, ATC80 Operator's Manual

Aire•Twin Mattress Replacement System Operator’s Manual
Important
Before using an Aire•Twin System, please read and understand this manual and all safety precautions prior to each application.
Direct: (716) 662-2551 Option 2
Toll Free: (800) 828-7341 extension 739
Fax: (716) 662-8795
1.0 Warranty
The ATC80 Control Unit is warranted free of defects in material and workmanship for a period of one (1) year. The ATM500 Mattress is warranted free of defects in material and workmanship for a period of one (1) year. The ATM800 Mattress is warranted free of defects in material and workmanship for a period of one (1) year.
The Control Unit and Mattress are warranted under the terms and conditions of the Gaymar warranty in place at the time of purchase. A copy of the warranty is available upon request. Gaymar disclaims all implied warranties including, but not limited to, the implied warranties of merchantability and of fitness for a particular purpose.
2.0 Symbols
Attention, consult accompanying documents
Class II, double insulated equipment
Type BF equipment
Dangerous voltage
Protective earth ground
Latex Free
2
Aire•Twin Mattress Replacement System Operator’s Manual
3.0 Indications for Use
This device is intended to assist in treating and preventing pressure ulcers.
4.0 Contraindications
Air support treatment is not recommended when spinal stability is a concern.
5.0 Safety Precautions
Review the following SAFETY PRECAUTIONS prior to using an Aire•Twin System.
DANGER
Risk of electric shock. Refer servicing to qualified service personnel.
WARNING
Disinfect the Aire•Twin system between patient installations. Failure to disinfect may risk cross- contamination and infection.
Check patient at least every 8 hours to assure proper system operation.
Disconnect the AC power from the wall outlet before attempting to clean the Control Unit. Do not
heat or steam autoclave any component of the system.
CAUTION
Some medical conditions may not respond to treatment of this type. Patient’s skin condition should be inspected regularly. Consult physician if any redness or skin breakdown occurs.
For grounding reliability, plug only into a properly grounded outlet.
Use minimal layers of sheeting and incontinence pads. Too many layers between the patient’s
skin and the support surface will reduce the effectiveness of the system.
Do not pull linens tightly over mattress. Tight sheets can cause “hammocking” and reduce effectiveness of treatment.
Portable and RF communications equipment can affect medical electrical equipment.
Make certain all mattress straps are secured to the bed frame to prevent mattress from sliding and
causing patient injury.
The Aire•Twin mattress is not intended to be AND DOES NOT FUNCTION AS a patient fall device. SIDE RAILS MUST BE USED WITH THE AIRE•TWIN MATTRESS TO PREVENT PATIENT FALLS, unless determined unnecessary based on the facility protocol or the patient’s medical needs determined by the facility. IN SUCH CASES THE USE OF OTHER SUITABLE PATIENT SAFETY MEASURES ARE RECOMMENDED. When using side rails, the use of side rail pads is strongly recommended. Failure to use a side rail pad may result in patient injury.
During mattress set-up, insure that all mattress air cells are inflated and that air cells are secured to the mattress base with the snaps located on each side of the air cell. Air cells not properly secured or inflated may result in compromised therapy.
Insure that the Aire•Twin mattress properly fits the bed frame on which it is being placed. Using the Aire•Twin mattress on a larger than 35 inch wide bed frame may result in mattress sliding and patient injury.