Gaumard S107.250 User Manual

Multipurpose Patient Care and CPR Infant
S107.250
®
Simulators for Health Care Education
Multipurpose Patient Care and CPR Infant is an interactive educational system developed to assist a certied instructor. It is not a substitute for a comprehensive understanding of the subject matter and not intended for clinical decision making.
User Guide 16.9.1
© Gaumard Scientic Company, 2016
All Rights Reserved
www.Gaumard.com
2 | User Guide | Multipurpose Patient Care and CRP Infant |
End User License Agreement
Care and Cautions
Overall Warnings .................................................................................................. 8
General ................................................................................................................... 8
Operating Conditions .............................................................................................. 8
Storage Conditions ................................................................................................. 8
IV Arm .....................................................................................................................8
Cleaning .................................................................................................................8
Stoma Guidelines, Warnings, and Maintenance ................................................9
User Guidelines ...................................................................................................... 9
Warnings ................................................................................................................9
Maintenance ........................................................................................................... 9
Equipment Set Up (Optional)
Power Supply .......................................................................................................10
®
Omni
2 Setup ......................................................................................................10
Working with the Simulator
Overview.............................................................................................................. 12
Filling and Drainage Tubes ...................................................................................12
Airway ................................................................................................................... 12
Appearance .......................................................................................................... 12
Breathing .............................................................................................................. 12
Circulation............................................................................................................. 12
Simulator ..............................................................................................................12
Optional Controller................................................................................................ 13
Terminology ........................................................................................................ 13
Facilitator .............................................................................................................. 13
Provider ................................................................................................................ 13
Airway Management ........................................................................................... 13
Nasal and Oral Intubation ..................................................................................... 13
Suction.................................................................................................................. 13
Pulmonary Ventilation ...........................................................................................14
Circulation ........................................................................................................... 14
Palpable Pulses .................................................................................................... 14
Activating the Pulses ............................................................................................ 14
iV Access ............................................................................................................. 14
Filling IV System ................................................................................................... 15
Directions for Use ................................................................................................. 15
Femoral Venous Access ....................................................................................... 16
| Multipurpose Patient Care and CRP Infant | User Guide | 3
Filling the Femoral Venous and Intraosseous Access .......................................... 16
Systemic .............................................................................................................. 16
Intraosseous Access.............................................................................................16
Filling the Femoral Venous Access....................................................................... 16
Instructions for Use............................................................................................... 16
Replacing the Tibia .............................................................................................. 17
Umbilical Cord ...................................................................................................... 17
Filling the Umbilical Cord ...................................................................................... 17
Patient Care......................................................................................................... 18
Bandaging ............................................................................................................18
Heel Stick Exercises ............................................................................................. 18
Eyes/Ophthalmologic Exercises ........................................................................... 18
Tongue .................................................................................................................. 18
Range of Movement ............................................................................................. 18
Nasogastric and Orogastric Exercises .................................................................18
Nose and Throat ................................................................................................... 18
Enema Administration...........................................................................................18
Filling the Colon ................................................................................................... 18
Urinary System ..................................................................................................... 18
Ostomy Care ........................................................................................................19
Ostomy Connections ............................................................................................ 19
Male and Female Organs ..................................................................................... 20
Removing Male Genitalia .....................................................................................20
OMNI
Using OMNI® 2 ..................................................................................................... 21
Main screen .......................................................................................................... 21
Changing a vital sign ............................................................................................ 21
CPR ...................................................................................................................... 22
Feedback graphics ............................................................................................... 22
Actions .................................................................................................................. 22
Calibration ............................................................................................................22
®
2 (Optional)
Appendix
Troubleshooting .................................................................................................25
General Troubleshooting Guide............................................................................25
Warranty .............................................................................................................. 26
Exclusive One-Year Limited Warranty .................................................................. 26
4 | User Guide | Multipurpose Patient Care and CRP Infant |
| Multipurpose Patient Care and CRP Infant | User Guide | 5
End User License Agreement
This is a legal agreement between you, the end user, and Gaumard® Scientic Company, Inc. (“Gaumard”). This software is protected by copyright laws and remains the sole property of Gaumard. By installing the eCPR (the "Software") media, you agree to be bound by the terms of this agreement. If you do not agree to the terms of this agreement, promptly return the uninstalled media and accompanying items to Gaumard at the address indicated below.
1. Grant of License. Gaumard hereby grants to you (an individual or institution) the right to install and activate the Software on one computer for use with one Interactive patient simulator system. The software may also be installed on any number of other computers at the same institution so that students may access the learning resources. One copy of the software may be made for backup purposes. You may not network this Software, or allow multiple users unless you purchased a multi­user workstation license. Sharing this Software with other individuals or allowing other individuals to view the contents of this Software is in violation of this license.
2. Copyright. The Software is owned by Gaumard and protected by United States copyright laws and international treaty provisions. Therefore, you must treat this Software like any other copyrighted material. You may not make this Software or copies thereof available in any manner or form or use, copy or transfer the Software, in whole or in part, except as provided herein.
3. Other Restrictions. You may not rent or lease this Software to any other party. You may not alter, merge, modify, adapt, reverse engineer, decompile or disassemble the software, or disclose the contents of this Software to any other party.
4. Electronic Transmission of Software. If you received the Software by electronic transmission or by Internet delivery, by installation of the Software, you acknowledge that you have read and understand this license agreement and agree to be bound by its terms and conditions.
5. Term of Agreement. The term of this Agreement and the license granted to you pursuant hereto shall commence upon installation of this Software. This Agreement and the license granted herein may otherwise be terminated by Gaumard in the event that you are in breach of any provision of this Agree¬ment. In the event of termination, you agree to immediately return this Software, accompanying items, and any copies thereof to Gaumard.
6. LIMITED WARRANTY
(A) THE CD-ROM MEDIA (THE "MEDIA") WHICH CONTAINS THIS SOFTWARE IS WARRANTED,
FOR A PERIOD OF 30 DAYS FROM THE DATE OF PURCHASE, TO BE FREE FROM DEFECTS IN MATERIAL AND WORKMANSHIP. ELECTRONIC TRANSMISSION IS WARRANTED TO BE FREE FROM DEFECTS AT THE MOMENT OF TRANSMISSION. YOUR SOLE AND EXCLUSIVE REMEDY, AND GAUMARD'S SOLE LIABILITY, IS TO REPLACE THE DEFECTIVE MEDIA OR TO REPEAT THE ELECTRONIC TRANSMISSION PROVIDED THAT YOU NOTIFY GAUMARD IN WRITING OF SUCH DEFECT OR DEFECTIVE TRANSMISSION AND RETURN THE DEFECTIVE MEDIA, IF ANY, DURING THE 30-DAY WARRANTY PERIOD.
6 | User Guide | End User Liscense Agreement |
(B) EXCEPT AND TO THE EXTENT EXPRESSLY PROVIDED IN PARAGRAPH (A), THE SOFTWARE
AND ACCOMPANYING WRITTEN MATERIALS ARE PROVIDED ON AN "AS IS" BASIS, WITHOUT ANY WARRANTIES OF ANY KIND, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE. NO ORAL OR WRITTEN INFORMATION OR ADVICE GIVEN BY GAUMARD, ITS DEALERS, DISTRIBUTORS, AGENTS OR EMPLOYEES SHALL CREATE A WARRANTY OR IN ANY WAY INCREASE THE SCOPE OF THIS WARRANTY, AND YOU MAY NOT RELY ON ANY SUCH INFORMATION OR ADVICE. GAUMARD DOES NOT WARRANT, GUARANTEE, OR MAKE ANY REPRESENTATIONS REGARDING THE USE OR THE RESULTS OF USE, OF THE SOFTWARE OR WRITTEN MATERIALS IN TERMS OF CORRECTNESS, ACCURACY, RELIABILITY, CURRENTNESS, OR OTHERWISE, AND THE ENTIRE RISK AS TO THE RESULTS AND PERFORMANCE OF THE SOFTWARE IS ASSUMED BY YOU. IF THE SOFTWARE OR WRITTEN MATERIALS ARE DEFECTIVE, YOU AND NOT GAUMARD OR ITS DEALERS, DISTRIBUTORS, AGENTS, OR EMPLOYEES, ASSUME THE ENTIRE COST OF ALL NECESSARY SERVICING, REPAIR OR CORRECTION OTHER THAN EXPRESSLY DESCRIBED ABOVE.
(C) NEITHER GAUMARD NOR ANYONE ELSE WHO HAS BEEN INVOLVED IN THE CREATION, PRODUCTION OR DELIVERY OF THIS PRODUCT SHALL BE LIABLE FOR ANY DIRECT, INDIRECT, CONSEQUENTIAL OR INCIDENTAL DAMAGES (INCLUDING DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION, AND THE LIKE) ARISING OUT OF THE USE OR INABILITY TO USE SUCH PRODUCT OR RELATED TO THIS AGREEMENT EVEN IF GAUMARD HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. GAUMARD SHALL NOT BE LIABLE TO YOU FOR ANY INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES OR LOST PROFITS ARISING OUT OF OR RELATED TO THIS AGREEMENT OR YOUR USE OF THE SOFTWARE AND/OR THE RELATED DOCUMENTATION, EVEN IF GAUMARD HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. IN NO EVENT SHALL GAUMARD'S LIABILITY HERE UNDER, IF ANY, EXCEED THE PURCHASE PRICE PAID BY YOU FOR THE SOFTWARE.
ALL RIGHTS NOT EXPRESSLY GRANTED IN THIS LICENSE AGREEMENT ARE RESERVED BY GAUMARD.
ACKNOWLEDGMENT
BY INSTALLATION OF THIS SOFTWARE, YOU ACKNOWLEDGE THAT YOU HAVE READ AND UNDERSTAND THE FOREGOING AND THAT YOU AGREE TO BE BOUND BY ITS TERMS AND CONDITIONS. YOU ALSO AGREE THAT THIS AGREEMENT IS THE COMPLETE AND EXCLUSIVE STATEMENT OF AGREEMENT BETWEEN THE PARTIES AND SUPERSEDES ALL PROPOSED OR PRIOR AGREEMENTS, ORAL OR WRITTEN, AND ANY OTHER COMMUNICATIONS BETWEEN THE PARTIES RELATING TO THE LICENSE DESCRIBED HEREIN.
| End User Liscense Agreement | User Guide | 7
Care and Cautions
Overall Warnings
Remember that damage caused by misuse is not covered by your warranty. It is critical to understand and comply with the following
guidelines:
GENERAL
This simulator is constructed of material
that approximates skin texture. Therefore, in handling the model, use the same gentle techniques as you would in working with a patient.
Ball point pens, ink and markers permanently
stain the skin.
Do not wrap this or any other Gaumard
product in newsprint.
®
Do not use alcohol, acetone, Betadine
any other antiseptic which contains iodine in this or any Gaumard products could damage or stain the skin of the simulator.
Replacement parts are available from
Gaumard Scientic or your Distributor.
®
simulator. These
or
Humidity: 40%-60% (non-condensing).
IV ARM
Treat the simulator with the same precautions
that would be used with a real patient. Only use Gaumard’s provided simulated blood. Any other simulated blood containing sugar or any additive may cause blockage and/or interruption of the vascular system.
The use of needles smaller than 22 gauge will
reduce the lifetime of the lower arms’ skin and veins.
After cleaning and drying the arm, lightly
dust it with talcum powder. This will keep the training arm supple and easy to use.
WARNING
Vein tubing contains latex which may cause allergic reactions. Users allergic or sensitive to latex should avoid contact. Discontinue use of this product and seek medical attention if an allergic reaction occurs.
WARNING
To avoid damage to the simulator, please store and ship it in the clear poly bag provided.
OPERATING CONDITIONS
Operating the simulator outside these ranges may affect performance:
Operating temperature: 50°- 95° F (10°- 35°
C).
Humidity: 5%-95% (non-condensing).
STORAGE CONDITIONS
Improper storage may damage the simulator.
Keep it stored in the box and/or bag provided.
Do not stack or store heavy materials on top
of the carton.
Storage temperature: 32°- 113° F (0°- 45° C).
CLEANING
Clean the skin of the simulator after every
training session. The skin should be cleaned with a cloth dampened with diluted liquid dish washing soap and dry thoroughly.
Remove all traces of any lubricant.
Do not clean with harsh abrasives.
The simulator is “splash-proof” but not
waterproof. Do not submerge or allow water to enter the interior of the simulator.
8 | User Guide | Care and Cautions |
Stoma Guidelines, Warnings, and Maintenance
USER GUIDELINES
Always handle the stomas with clean hands.
WARNINGS
Do not palpate using ngernails
Do not clean with alcohol or aggressive
solvents
Do not pack any sharp objects with the
stomas
Do not press the stomas against soiled
surfaces, ink, or newsprint. The stoma material is absorbent.
The stomas are not detachable; never
attempt to remove the stomas.
MAINTENANCE
Prevent items from resting or pressing
against the stomas as indentations will form on the pressure points.
The stomas may return to the normal shape
after the pressure is relieved.
Place talcum powder on the stoma surface to
reduce tackiness. This can be reapplied as needed.
Clean the stomas using a mild solution of
soap and water.
Apply talcum powder to return the surface to
a skin-like feel and appearance.
WARNING
The lubricants and other accessories provided are for use with the accompanying patient simulator only. The lubricants and other accessories are not suitable for human use or medical treatment/diagnosis and should never be used for such purposes.
| Care and Cautions | User Guide | 9
Loading...
+ 18 hidden pages