1.0 Configuring your STU-III for the 90si 3
1.1 AT&T Security Plus 3
1.2 AT&T, Lucent and General Dynamics 1100 (*1) 4
1.3 AT&T, Lucent, General Dynamics 1900 SDD (*1) 5
1.4 GE/RCA 2400 6
1.5 GE 9600 7
1.6 Motorola SECTEL 1000/1500 8
1.7 Motorola SECTEL MMT 1500 9
1.8 L-3 Communications STE 10
2.0 90si Status LED's 11
2.1 Power-up 11
2.2 Communications Errors 11
2.3 System Errors 11
2.4 Contact GFS Customer Service 11
3.0 Glossary of Secure Facsimile Terms 12
*1. GateWay Fax Systems, Inc. would like to gratefully acknowledge the contribution of ETR Technical
Services (336-698-9358) for providing the MODEM configuration procedure for the ATT 1100. And 1910
90si Reference Guide
GateWay Fax Systems, Inc., www.gwfs.com, 1-877-951-9800 page 3/13
1.0 Configuring your STU-III for the 90si
The most common cause of 90si operational problems are attributed to not having the STU-III's
Secure Data port configured for "Synchronous" operation. The following sections provide stepby-step instructions for configuring various secure telephones for "Synchronous" operation as
well as setting "speed" and "duplex" to provide optimum performance with the 90si. The "Press"
column indicates which button on the secure telephone should be pressed. The "Display" column
indicates what the responding display will show. The first line indicates the state of the secure
telephone before proceeding.
1.1 AT&T Security Plus
Objective: To set Secure Data Mode for 4.8 Kbps, Full Duplex, Synchronous.
While On or Off-Hook:
Operation Complete (Sets Synchronous)
3, 4, #
Operation Complete (Sets 4.8 Kbps, Full Duplex)
3, 0, #
SD:48 FDX SYNC (Displays new configuration)
Program
90si Reference Guide
GateWay Fax Systems, Inc., www.gwfs.com, 1-877-951-9800 page 4/13
1.2 AT&T, Lucent and General Dynamics 1100
Objective: To set Secure Data Mode for 9.6 Kbps, Full Duplex, Synchronous.
While On or Off-Hook:
MAIN MENU / Secure Voice
NEXT
MAIN MENU / Secure Data
SELECT
Ex. SD:9.6 FDX, ASYNC / 2.4 Full Duplex
NEXT (until...)
SD:9.6 FDX, SYNC / previous menu
MENU
Objective: To set MODEM; OUTPUT to -6 dBm and CONFIG to TRELLIS (*1)
While On Hook and with Master CIK inserted:
MAIN MENU / Secure Voice
NEXT (until…)
MAIN MENU / Change Config
SELECT
CHANGE CONFIG / Security Config
NEXT (until...)
CHANGE CONFIG / Network Config
SELECT
NETWORK CONFIG / Common Rining
NEXT
NETWORK CONFIG / Modem Output
SELECT
MODEM OUTPUT / Output = -10dBm
SELECT
OUTPUT / increment level
SELECT
OUTPUT = -9dBm / increment level
SELECT (3 times until…)
OUTPUT = -6dBm / increment level
NEXT (until…)
OUTPUT = -6dBm / save level
SELECT
OUTPUT = -6dBm / previous menu
SELECT
NETWORK CONFIG / modem output
NEXT (until…)
NETWORK CONFIG / previous menu
SELECT
CHANGE CONFIG / Network Config
NEXT
CHANGE CONFIG / Modem Config
SELECT
MODEM CONFIG / Trellis coding
SELECT
TRELLIS disabled / enable Trellis
SELECT
TRELLIS enabled / enable Trellis
MENU