This equipment has been tested and found to comply with the limits for a class B
digital device, pursuant to part 15 of the FCC rules. These limits are designed to
provide reasonable protection against harmful interference in a typical installation.
This equipment generates, uses and can radiate radio frequency energy and if
not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to
correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna on the device experiencing the
interference
Increase the separation between the Door Manager and the equipment
experiencing the interference.
Connect the equipment into an outlet on a circuit different from that to
which the Door Manager is connected
In order to maintain compliance with FCC regulations, no changes can be made
to this equipment without the approval of Gatekeeper Systems, Inc. The user is
cautioned that any changes or modifications made to the equipment without the
approval of Gatekeeper Systems, Inc. could void the user’s authority to operate
this equipment.
Operation is subject to the following two conditions: (1) this device may not cause
interference, and (2) this device must accept any interference, including
interference that may cause undesired operation of the device.
This device complies with Industry Canada licence-exempt RSS standard(s).
Operation is subject to the following two conditions: (1) this device may not cause
interference, and (2) this device must accept any interference,including
interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux
appareils radio exempts de licence. L'exploitation est autorisée aux deux
conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2)
l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même
si le brouillage est susceptible d'en compromettre le fonctionnement.
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du
Canada.
Consult the dealer or experienced technician for the device experiencing
the interference
The Gatekeeper Systems SmartKey2 combines the functions of the "SmartKey"
and CartKey2 with the ability to pair wheels
SmartKey2 Diagram
1.1
The SmartKey2 uses
the same enclosure and battery as the Smart Key.
3
2
Lock and Unlock
The SmartKey2 will lock or unlock any (GS2, Black Dot, Red Dot, Grey Dot,
Green Dot) Gatekeeper Systems wheel. When the
is pressed, the appropriate command is first sent out on 8KHz (with
approximately 3 feet / 1 meter range) and then sent out on 2.4GHz (with
approximately
When the Lock button is pressed, only 8HKz command will be sent out (with
approximately 3 feet / 1 meter range).
All wheels within the appropriate range will lock or unlock.
12 feet / 4 meter range).
Unlock button
3 Status
The SmartKey2 can retrieve status information from any (GS2, Black Dot, Red
Dot, Grey Dot, Green Dot) Gatekeeper Systems wheel.
3.1 GS2 and Black Dot Wheel Status
To retrieve status information from a GS2 or Black Dot wheel (or a Red Dot /
Grey Dot w
press the black status button once. The LCD screen should display rEC .
When the display changes from
viewing. The scroll button is used to c
received from the wheel.
3.2 Red Dot and Grey Dot Wheel Status
To retrieve status information from a Red Dot or a Grey Dot wheel (via 2.4GHz)
place the SmartKey2 within 3 feet (1 meter) of the wheel
red/grey status button once.
meters away. The LCD screen should display rEC . When the display changes
from
used to cycle through the status information received from the wheel.
3.3 Green Dot Wheel Status
To retrieve status information from a Red Dot or a Grey Dot wheel (via 2.4GHz)
place the SmartKey2 within 3 feet (1 meter) of the wheel and press the green
status button once.
away
to
rEC
cycle through the status information received from the wheel.
heel via 8KHz) place the SmartKey2 within 1 inch of the wheel and
to
rEC
Make sure other wheels are at least 30 feet / 10
rEC to iD2 the wheel status is ready for viewing. The scroll button is
Make sure other wheels are at least 30 feet / 10 meters
.The LCD screen should display
iD2
the wheel status is ready for viewing. The scroll button is used to
ycle through the status information
iD2
the wheel status is ready for
to be read
rEC . When the display changes from
and press t
he
4
Pairing Wheels
The SmartKey2 can pair one Grey Dot and one Green Dot wheel.
Grey Dot and one Green Dot wheel:
1.
Place the Grey Wheel and the Green wheel to be paired within 3 feet / 1
meter of the SmartKey2. (wheels ma
2. Make sure there are no other Red Dot / Grey Dot / Green Dot wheels
within 30 feet / 10 meters of the SmartKey2.
3. Press the pair button once.
The SmartKey2 will display dashes as it is performing the pairing operation.
When the pa
if the wheels were successfully paired or an error code. See the table below for
error code definitions:
iring operation is complete, the Super Key will display either Pass
y be on a shopping cart).
To pair one
Error Code
ER 0
ER 1
ER 2
ER 3
ER 4
ER 5
ER 6
ER 7
ER 8
The SmartKey2 will only pair wheels with SW versions 2.5 or greater. Both
wheels must be at the same SW version.
Super Key did not find any wheels to pair
Change Grey Wheel Battery and try again
Sup
er Key did not find a
Super Key did not find a Grey wheel to pair
Wheels too far from Super Key
Super Key found more than one Grey / Green wheel
Communication Problem
Change Green Wheel
Definition
Green wheel
Pairing Failed
Battery and try again
to pair
5.3 Signal Analysis Mode Codes
The SmartKey2 will d
8KHz.
8KHz Codes
8KHz
Command Codes
Code
3 Normal Perimeter Lock
4 Indoor Unlock (No delay)
6
10
11
12
13
14
15
16
19
20
22
23
isplay various codes to indicate the different codes used for
Normal U
Definition
nlock (10 Second delay)
10 Minute Permission
30 Minute Permission
For more information about the Door Manager and troubleshooting, to order parts
or report an issue, contact the Gatekeeper Systems Inc. regional Customer
Support office nearest to your location.
Hong Kong
Gatekeeper Systems (HK), Ltd.
Unit 2318~2319, Level 23, Tower 1, Metroplaza
NO. 223 Hing Fong Road, Kwai Fong, N.T.,
HONG KONG
(852) 2413 3050
USA
Gatekeeper Systems, Inc.
8 Studebaker
Irvine, CA 92618
(888) 808-9433