Working voltage
4.5 V ~ 5.5V DC
Average current
< 85 mA
Interface level
3.3 V
Measuring range
0~5%VOL optional
Output signal
PWM
UART
0.4-2V DC
Preheat time
3min
Reponse Time
T90 < 90s
Working temperature
0 ~ 50
Working humidity
0~95%RH
Weight
15 g
Lifespan
>5 year
Dimension
57.5×34.7×16mmL×W×H
1. Profile
Main functions and features
High sensitivity, High resolution Low power consumption Output modes: UART, analog voltage signal, PWM wave Quick response Temperature compensation, excellent linear output Good stability Long lifespan Anti-water vapor interference No poisoning
2 Main technical parameters
Target Gas
Measuring
Range
Accuracy
Mark
Carbon Dioxide
(CO2)
0~2000ppm
±(50ppm
+5%readin
g value)
Temperature
compensation
0~5000ppm
Temperature
compensation
0~1%VOL
Temperature
compensation
0~3%VOL
Temperature
compensation
0~5%VOL
Temperature
compensation