DO NOT OPERATE THIS APPLIANCE BEFORE READING THE INSTRUCTION BOOKLET
DO NOT PLACE ARTICLES ON OR AGAINST THIS APPLIANCE
DO NOT STORE CHEMICALS OR FLAMMABLE MATERIALS OR SPRAY AEROSOLS NEAR THIS APPLIANCE
DO NOT OPERATE THE APPLIANCE INDOORS
DO NOT OPERATE IN AN ENCLOSED AREA
ACCESSIBLE PARTS MAY BE VERY HOT. KEEP YOUNG CHILDREN AWAY.
Minimum clearance from combustible materials: 1 metre
Important: Retain these instructions for future use.
Page 2
INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS
Safety
Before attempting to operate this heater, the
following basic safety precautions should be
taken to reduce the risk of re, electric shock
and personal injury. It is important to read
the instruction manual and to understand its’
applications, limitations and potential hazards
associated with this heater.
This heater is not intended for use by persons
(including children) with reduced physical, sensory
or mental capabilities, or lack of experience
and knowledge, unless they have been given
supervision or instruction concerning the use of
the appliance by a person responsible for their
safety.
This heater is not designed for use within 1m or
above a water source.
It is important that you read, understand and
follow these instructions very carefully. They are
designed for the safety of yourself and others
ensuring a long and trouble free service life from
your heater.
This electric heater complies with New Zealand
and International standards and safety
requirements.
Repairs should only be carried out by qualied
persons using original spare parts. Failure to do so
may result in considerable danger to the operator.
SAFE OPERATION
Beware of Children and Pets
Children should not be allowed to touch or operate
heaters or touch extension cords, if used. All
heaters should be kept out of reach of children,
preferably stored or locked in a secure cabinet or
room when not in use.
Do Not Abuse the Power Cord
Never yank or pull on the power cord to disconnect
it from the mains supply socket. Never carry your
heater by its’ power cord. Keep the power cord
away from heat, oil, solvents and sharp edges.
Check the power cord regularly for any damage
and if the power cord becomes damaged have it
replaced by an authorised service facility.
Extension Cords and Reels
This heater is NOT designed to run off an
extension cord. If you require an additional power
point please have one installed by a qualied
electrician.
The use of extension cords may cause power
voltage loss which will result in damage to the
appliance this will NOT be covered under warranty.
Installation
Always ensure you use the correct xing method
found in the mounting instructions on page 4. This
heater is not designed for use within 1m or above
a water source. All installations must meet the
requirements of New Zealand Standard AS/NZS
3000:2007.
Ensure that the heater is not positioned directly
above, below or in front of a power point or
switch.
This heater is not designed to be used with 3rd
party timer or programmable system.
FOR YOUR SAFETY
WARNING: Fire risk exists if this heater is
covered by or positioned close to curtains or
other combustible materials.
NOTE: Ensure that this heater is connected
directly to an outdoor power point.
The electrical system of this heater must be
connected with an automatic circuit breaker
and/or residual current device (RCD). If
uncertain have a qualied electrician check
your electrical system before installation and/
or use.
All electrical connections are made in a dry
area.
Outdoor power points must be weatherproof
and installed by a qualied electrician.
The distributor is not responsible for
incorrectly chosen additional xing accessories
or any damage which may be caused by an
incorrectly tted heater.
2
Page 3
SPECIFIC SAFETY INSTRUCTIONS
WARNINGS
Do not use the heater in areas where there is a
risk of explosion or re from ammable gases.
Ensure that the heating area is kept clear of
combustible materials. Do not use the heater in
damp areas, without suitable ventilation. This
heater is not designed for use within 1m or
above a water source. Do not place within one
metre (1m) of any water source. Do not place
directly in front of, below or above any power
points or switches.
Fire risk exists if this heater is covered by or
positioned close to curtains or other combustible
materials.
• This heater is intended for domestic/
household use only.
• Always ensure that this heater is installed as
per the requirements noted in New Zealand
Standard AS/NZS 3000:2007.
• Always keep heater at least one metre (1m)
from combustible materials.
• DO NOT locate this heater directly below,
above or in front of the power supply socket
or switch.
• DO NOT use a 3rd party timer, or
programmable system with this heater.
• DO NOT clean the heater while the heater is
on or plugged into the mains power supply.
• DO NOT touch any part of the heater while on,
hot surfaces may burn.
• DO NOT use the heater as a dryer.
• DO NOT attempt to modify the heater, power
cord, power plug or the supplied accessories
in any way.
• DO NOT expose the heater to rain, water, or
use in damp wet conditions.
• NEVER cover this heater.
• NEVER carry the heater by its power supply
cord.
• NEVER use with the power cord coiled,
bundled up or tied up. Always extend fully
before use.
• NEVER use the heater if any part of it is
damaged.
• Ensure that the heater is disconnected from
the mains supply when installing, cleaning or
removing/installing.
• Ensure this heater is not left on when
unattended.
• Ensure the heater is not used in areas where
ammable gases are present, e.g. paint,
petrol etc.
• Always turn the heater OFF at the unit switch
and the power point switch when not in use
for extended periods of time.
• Always allow the heater to cool, about one
(1) hour after the heater has been turned off,
before cleaning the heater.
• Always ensure that the power cord is fully
extended and NOT in contact with any part of
the heater.
• Always ensure that the heater is kept clean
and free from dust.
• Only use this heater when securely attached
to an umbrella pole on a level surface.
3
Page 4
ELECTRICAL DATAMOUNTING AND OPERATING
INSTRUCTIONS
IMPORTANT
This product is tted with a sealed electrical
connection plug that is compatible with the heater,
the mains supply for New Zealand and meets
the requirements of international standards. This
heater must be connected to a supply voltage that
is equal to that stated on the rating label.
If the mains connection plug or power cord
becomes damaged it must be replaced with a
complete assembly that is identical to the original,
and this must be replaced by an authorised
service centre.
Always follow the New Zealand requirements for
connection to the mains supply. If in doubt always
consult a qualied electrician.
Technical Specication
ModelGM135-017
Voltage:220V-240V~ 50Hz
Input Wattage:1500W
Unit Weight:3.5Kg
IP Rating:IPx3
Heater specications can be found on the data
label.
THIS PRODUCT SHOULD ONLY BE USED
UNDER AN UMBRELLA AND MUST NOT BE
USED OR LEFT IN WET CONDITIONS.
For best results and your safety, please follow the
instructions carefully. DO NOT modify this product
in any way as the distributor will accept no liability
for improper use.
MOUNTING THE HEATER
Step 1
Ensure umbrella is secure and stable by using a
suitable umbrella base.
Step 2
Place heater on the umbrella pole.
Step 3
Slide heater up the umbrella pole to the desired
height (no less than 1.8m) and tighten thumb
screw.
IMPORTANT
Step 4
Bring mains lead through hole in table, contain
lead around umbrella pole and connect into base
of heater.
Step 5
Connect plug on mains lead into an RCD protected
socket or into an outdoor IP23 weatherproof
socket.
4
Page 5
POSITIONING THE HEATER
When choosing a mounting position, it is
important to ensure the heater beams are NOT
pointed towards combustible surfaces. To adjust,
loosen the nuts on the side, set the heater to
desired position and re-tighten. Take care not to
pinch the cable between the back of the ttings
and the plate. DO NOT ADJUST WHEN HOT!
IMPORTANT
• Heater must not be located immediately
below a socket outlet.
• Heater must not be located in front of a
socket outlet.
• Heater must be installed at least 1.8m
above the oor.
REPLACING THE BULB
1. Unplug the unit.
2. Loosen the screw at the top of the unit and
hinge the front open. Release the bulb from
the spring loaded lampholders. Insert new
bulb into lampholders ensuring it is mounted
within 4 degrees horizontal along its length. It
is important that the end-caps on the lamp are
making good contact with the lampholders.
Take care not to handle the bulb surface.
Should the bulb be accidentally handled during
installation, it should be thoroughly cleaned with
methylated spirit and a lint free cloth. Close the
front and tighten screw.
TO OPERATE
1. Plug into 240V AC wall socket.
2. To turn on – switch the wall socket on.
3. Switch the heater ON:
500W - one switch
1000W - one switch
1500W - both switches
The red indicator light will turn on to indicate
your chosen setting.
4. To turn off – switch heater OFF and the wall
socket off.
5. Unplug lead from wall socket when not in use.
CLEANING
Always ensure that the heater has been left for
one hour to cool before cleaning.
1. Turn off and disconnect from mains power,
allow to cool.
2. Wipe unit over with a damp clean soft lint free
cloth.
3. For stubborn marks you can use a mild dish
washing solution on a damp clean soft lint free
cloth.
NEVER allow water or a mild dish washing
solution to enter or drip onto the heater.
NEVER use solvents, e.g. Petrol, Toluene,
Methylated Spirits etc to clean the heater, as
these will damage the surface nish and may
cause a re when unit is next used.
5
Page 6
This page has been left intentionaly blank
6
Page 7
This page has been left intentionaly blank
Gasmate® is a registered trademark of: Sitro Group Australia Pty Ltd www.gasmate.com.au
Aber, Hamilton, N.Z. www.gasmate.co.nz
7
Page 8
8
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.