Gasmate GM135-017 Installation, Operation And Maintenance Instructions

Page 1
Infrared Electric Umbrella Heater
Model No. GM135-017
4150-05/15
FOR OUTDOOR USE ONLY
DO NOT OPERATE THIS APPLIANCE BEFORE READING THE INSTRUCTION BOOKLET DO NOT PLACE ARTICLES ON OR AGAINST THIS APPLIANCE DO NOT STORE CHEMICALS OR FLAMMABLE MATERIALS OR SPRAY AEROSOLS NEAR THIS APPLIANCE DO NOT OPERATE THE APPLIANCE INDOORS DO NOT OPERATE IN AN ENCLOSED AREA ACCESSIBLE PARTS MAY BE VERY HOT. KEEP YOUNG CHILDREN AWAY.
Minimum clearance from combustible materials: 1 metre
Important: Retain these instructions for future use.
Page 2
INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS
Safety
Before attempting to operate this heater, the following basic safety precautions should be
taken to reduce the risk of re, electric shock
and personal injury. It is important to read the instruction manual and to understand its’ applications, limitations and potential hazards associated with this heater.
This heater is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety.
This heater is not designed for use within 1m or above a water source.
It is important that you read, understand and follow these instructions very carefully. They are designed for the safety of yourself and others ensuring a long and trouble free service life from your heater.
This electric heater complies with New Zealand and International standards and safety requirements.
Repairs should only be carried out by qualied
persons using original spare parts. Failure to do so may result in considerable danger to the operator.
SAFE OPERATION
Beware of Children and Pets
Children should not be allowed to touch or operate heaters or touch extension cords, if used. All heaters should be kept out of reach of children, preferably stored or locked in a secure cabinet or room when not in use.
Do Not Abuse the Power Cord
Never yank or pull on the power cord to disconnect it from the mains supply socket. Never carry your heater by its’ power cord. Keep the power cord away from heat, oil, solvents and sharp edges. Check the power cord regularly for any damage and if the power cord becomes damaged have it replaced by an authorised service facility.
Extension Cords and Reels
This heater is NOT designed to run off an extension cord. If you require an additional power
point please have one installed by a qualied
electrician.
The use of extension cords may cause power voltage loss which will result in damage to the appliance this will NOT be covered under warranty.
Installation
Always ensure you use the correct xing method
found in the mounting instructions on page 4. This heater is not designed for use within 1m or above a water source. All installations must meet the requirements of New Zealand Standard AS/NZS 3000:2007.
Ensure that the heater is not positioned directly above, below or in front of a power point or switch.
This heater is not designed to be used with 3rd party timer or programmable system.
FOR YOUR SAFETY
WARNING: Fire risk exists if this heater is covered by or positioned close to curtains or other combustible materials.
NOTE: Ensure that this heater is connected directly to an outdoor power point.
The electrical system of this heater must be connected with an automatic circuit breaker and/or residual current device (RCD). If
uncertain have a qualied electrician check
your electrical system before installation and/ or use.
All electrical connections are made in a dry area.
Outdoor power points must be weatherproof
and installed by a qualied electrician.
The distributor is not responsible for
incorrectly chosen additional xing accessories
or any damage which may be caused by an
incorrectly tted heater.
2
Page 3
SPECIFIC SAFETY INSTRUCTIONS
WARNINGS
Do not use the heater in areas where there is a
risk of explosion or re from ammable gases.
Ensure that the heating area is kept clear of combustible materials. Do not use the heater in damp areas, without suitable ventilation. This heater is not designed for use within 1m or above a water source. Do not place within one metre (1m) of any water source. Do not place directly in front of, below or above any power points or switches.
Fire risk exists if this heater is covered by or positioned close to curtains or other combustible materials.
• This heater is intended for domestic/ household use only.
• Always ensure that this heater is installed as per the requirements noted in New Zealand Standard AS/NZS 3000:2007.
• Always keep heater at least one metre (1m) from combustible materials.
• DO NOT locate this heater directly below, above or in front of the power supply socket or switch.
• DO NOT use a 3rd party timer, or programmable system with this heater.
• DO NOT clean the heater while the heater is on or plugged into the mains power supply.
• DO NOT touch any part of the heater while on, hot surfaces may burn.
• DO NOT use the heater as a dryer.
• DO NOT attempt to modify the heater, power cord, power plug or the supplied accessories in any way.
• DO NOT expose the heater to rain, water, or use in damp wet conditions.
• NEVER cover this heater.
• NEVER carry the heater by its power supply cord.
• NEVER use with the power cord coiled, bundled up or tied up. Always extend fully before use.
• NEVER use the heater if any part of it is damaged.
• Ensure that the heater is disconnected from the mains supply when installing, cleaning or removing/installing.
• Ensure this heater is not left on when unattended.
• Ensure the heater is not used in areas where
ammable gases are present, e.g. paint,
petrol etc.
• Always turn the heater OFF at the unit switch and the power point switch when not in use for extended periods of time.
• Always allow the heater to cool, about one (1) hour after the heater has been turned off, before cleaning the heater.
• Always ensure that the power cord is fully extended and NOT in contact with any part of the heater.
• Always ensure that the heater is kept clean and free from dust.
• Only use this heater when securely attached to an umbrella pole on a level surface.
3
Page 4
ELECTRICAL DATA MOUNTING AND OPERATING
INSTRUCTIONS
IMPORTANT
This product is tted with a sealed electrical
connection plug that is compatible with the heater, the mains supply for New Zealand and meets the requirements of international standards. This heater must be connected to a supply voltage that is equal to that stated on the rating label.
If the mains connection plug or power cord becomes damaged it must be replaced with a complete assembly that is identical to the original, and this must be replaced by an authorised service centre.
Always follow the New Zealand requirements for connection to the mains supply. If in doubt always
consult a qualied electrician.
Technical Specication
Model GM135-017
Voltage: 220V-240V~ 50Hz
Input Wattage: 1500W
Unit Weight: 3.5Kg
IP Rating: IPx3
Heater specications can be found on the data
label.
THIS PRODUCT SHOULD ONLY BE USED UNDER AN UMBRELLA AND MUST NOT BE USED OR LEFT IN WET CONDITIONS.
For best results and your safety, please follow the instructions carefully. DO NOT modify this product in any way as the distributor will accept no liability for improper use.
MOUNTING THE HEATER
Step 1
Ensure umbrella is secure and stable by using a suitable umbrella base.
Step 2
Place heater on the umbrella pole.
Step 3
Slide heater up the umbrella pole to the desired height (no less than 1.8m) and tighten thumb screw.
IMPORTANT
Step 4
Bring mains lead through hole in table, contain lead around umbrella pole and connect into base of heater.
Step 5
Connect plug on mains lead into an RCD protected socket or into an outdoor IP23 weatherproof socket.
4
Page 5
POSITIONING THE HEATER
When choosing a mounting position, it is important to ensure the heater beams are NOT pointed towards combustible surfaces. To adjust, loosen the nuts on the side, set the heater to desired position and re-tighten. Take care not to
pinch the cable between the back of the ttings
and the plate. DO NOT ADJUST WHEN HOT!
IMPORTANT
• Heater must not be located immediately below a socket outlet.
• Heater must not be located in front of a socket outlet.
• Heater must be installed at least 1.8m
above the oor.
REPLACING THE BULB
1. Unplug the unit.
2. Loosen the screw at the top of the unit and hinge the front open. Release the bulb from the spring loaded lampholders. Insert new bulb into lampholders ensuring it is mounted within 4 degrees horizontal along its length. It is important that the end-caps on the lamp are making good contact with the lampholders.
Take care not to handle the bulb surface. Should the bulb be accidentally handled during installation, it should be thoroughly cleaned with methylated spirit and a lint free cloth. Close the front and tighten screw.
TO OPERATE
1. Plug into 240V AC wall socket.
2. To turn on – switch the wall socket on.
3. Switch the heater ON: 500W - one switch 1000W - one switch 1500W - both switches
The red indicator light will turn on to indicate
your chosen setting.
4. To turn off – switch heater OFF and the wall socket off.
5. Unplug lead from wall socket when not in use.
CLEANING
Always ensure that the heater has been left for one hour to cool before cleaning.
1. Turn off and disconnect from mains power, allow to cool.
2. Wipe unit over with a damp clean soft lint free cloth.
3. For stubborn marks you can use a mild dish washing solution on a damp clean soft lint free cloth.
NEVER allow water or a mild dish washing
solution to enter or drip onto the heater.
NEVER use solvents, e.g. Petrol, Toluene,
Methylated Spirits etc to clean the heater, as
these will damage the surface nish and may cause a re when unit is next used.
5
Page 6
This page has been left intentionaly blank
6
Page 7
This page has been left intentionaly blank
Gasmate® is a registered trademark of: Sitro Group Australia Pty Ltd www.gasmate.com.au Aber, Hamilton, N.Z. www.gasmate.co.nz
7
Page 8
8