Gasmate AH2067ODS, AH2066 User Manual

Page 1
STELLAR BLACK
DELUXE AREA HEATER
Model No. AH2067ODS & AH2066
The ideal solution for extending the season of
outdoor entertaining
Creates a stylish and attractive ambience
Rotary ignition
Includes a safety ‘tip-over’ switch that halts supply of gas to the unit should it be accidentally knocked over
Oxygen depletion system for enhanced safety
Stainless steel burner for extra long-term reliability
Complete with hose and POL regulator
Efficient and powerful 40MJ/h output
Adjustable heat output
Operates for approximately 9 hours on a properly filled 9Kg Propane cylinder
For outdoor use only
Gas certified to Australian standards
FOR YOUR SAFETY
If you smell gas:
1. Shut off the gas to the appliance.
2. Extinguish any open flame.
3. If odour continues, immediately call your gas supplier.
Do not store or use gasoline or other flammable vapour and liquids in the vicinity of this or any other appliance.
WARNING
Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage.
Read the instructions thoroughly before installing or servicing this equipment.
FOR OUTDOOR USE ONLY PROPANE GAS
IMPORTANT: RETAIN THESE INSTRUCTIONS FOR FUTURE USE
03908 04/19
Page 2
Installation, Operation and Maintenance Instructions
INSTALLATION
3. Proper clearance from combustible materials must be
Important Safety Rules
This appliance must only be used in a well ventilated area.
1. This appliance shall not be installed or used indoors, in buildings, garages or any other enclosed area.
2. DO NOT place articles on or against this appliance.
3. DO NOT use or store flammable materials near this appliance.
4. Children and adults should be alerted to the hazards of high surface temperatures, burns and clothing ignition.
5. Children should be carefully supervised when they are in the area of the appliance.
6. NEVER hang anything including clothes or other flammable items on the appliance.
7. DO NOT operate this appliance unless it is fully assembled with burner guard in place.
8. DO NOT SPRAY AEROSOLS IN THE VICINITY
OF THIS APPLIANCE WHILE IT IS IN OPERATION.
9. Installation and repair should be done by a qualified service person. The appliance must be inspected before use and at least annually by a qualified service person. It is imperative that control compartment, burners and circulating air passages of the heater be kept clean.
Prior to assembling your appliance, the following must be reviewed. Compliance with the following should result in satisfactory heater operation. This instruction manual should be retained for future reference. The installation must conform with local codes or authority having jurisdiction.
1. The patio heater is intended for heating residential and non-residential outdoor spaces. The installation must conform with local codes and with the Australian Standard AS/NZS 5601.
2. Adequate clearance around air openings into the combustion chamber, clearances from combustible materials, provisions for accessibility and for combustion and ventilating air supply must be maintained at all times when the appliance is operating.
maintained at all times. The minimum clearances are as follows:
Minimum Clearance from Combustibles:
Side 500 mm Rear 500 mm
Ceiling 1000 mm
Combustible materials are considered to be wood, compressed paper, plant fibres, plastic, plexiglas or other materials capable of being ignited and burned.
Such materials shall be considered combustible even though flame proofed, fire-retardant treated or plastered. Additional clearance may be required for glass, painted surfaces and other materials which may be damaged by radiant or convection heat.
4. Heaters must be placed on a level and adequate footing and be readily accessible.
5. The gas manifold supply pressure must be regulated at
2.75 kPa utilising an AGA approved regulator (supplied with heater).
6. The appliance must be inspected before each use, and at least annually by a qualified service person.
a. The appliance area must be kept clear and free of
combustible materials, gasoline and other flammable vapours and liquids.
b. Gas orifices and burner must be kept clear of dirt
and cobwebs. Flow of combustion and ventilation air through the perforated portions of the heater must not be obstructed. Cleaning with a soft brush before use and at least every six months is recommended.
c. All gas connections should be checked for
leaks utilising a soap solution. Never use a flame for this purpose.
d. The flame pattern should be visually checked
whenever heater is operated. If flames extend beyond surface of the guard the appliance should be turned off and should not be operated again until the unit is serviced and or repaired.
e. Any cleaning agent used on the heater should be of a
non-combustible and non-corrosive nature.
f. The stainless steel emitter normally does not require
cleaning and should NEVER be painted.
2
Page 3
7. The hose must be protected from contact with hot or sharp surfaces both during use and while in storage. The hose assembly should be visually inspected prior to each use of the heater. If excessive abrasion or wear is evident, or the hose is cut, it must be replaced prior to operating the heater. The replacement hose assembly may be obtained from the manufacturer.
8. DO NOT use any pressure regulator or hose assembly other than those supplied with the appliance. Replacement pressure regulator and hose assembly must be those specified. Replacement parts maybe obtained from the manufacturer or your local sales representative.
9. Installation and use of this heater must conform with local codes and AS/NZS 5601.
10. This heater is designed to operate with a standard 9Kg propane cylinder with Approved Cylinder Connection.
11. The valve outlet must be maintained in good condition. When the cylinder is not in use, be sure to cover it with a dust cap. A leak test should be performed with soapy water whenever connecting a new cylinder. NEVER use a match to test for leaks.
12. The propane cylinder must be turned off whenever the heater is not in use. When the heater is to be stored indoors, the propane cylinder and the heater must be disconnected and the cylinder stored in accordance with the Standard for Storage and Handling of Liquefied Gases.
13. The appliance has been designed with several safety features which include a tip over switch.
Any modification to the heater not described in the installation instructions may compromise the safety of this appliance. Special concern is as follows:
(1) DO NOT bypass thermocouple safety burner;
(2) DO NOT operate heater without the guard;
Clothing or other flammable materials should not be hung from the heater, or placed on or near the heater. The area above the burner may be extremely hot. Direct contact with these metal surfaces should be avoided in order to prevent burns or clothing ignition.
POL CYLINDER CONNECTION DEVICE
IMPORTANT
Storage of an appliance indoors with the cylinder attached is only permitted if the size of the cylinder complies with AS/NZS 1596; otherwise cylinders must be stored outdoors in a well ventilated area.
The guards are fitted to this appliance to reduce the risk of fire or injury from burns and no part of it should be removed.
This appliance must be protected from exposure to rain.
Screw the coupling nut of regulator into the cylinder valve outlet.
Type of Gas Propane
Consumption 40 MJ/h
Operating Pressure 2.75 kPa
Injector Size 1.85 mm
AH2066 Colour Black
AH2067ODS Colour Graphite
Heater specifications can be found on the data label.
3
Page 4
AREA HEATER ASSEMBLY
Tools Required
Phillips head screwdriver
2 Adjustable spanners
Note: Remove any transit protection material
STEP 1
Secure the base to the cylinder house body with five M8 x 12mm long bolts.
STEP 2
Secure the burner head to the inside of the cylinder house body with five M5 x 8mm long screws, washers and nuts.
STEP 3
Securely attach the hose to the burner head and the regulator to a gas cylinder, check the connections for leaks using a soapy water solution.
Burner head assembly
Flexible hose assembly
STEP 4
Attach the door hinges to the body and the door with 8 M5 screws and nuts.
M8 bolt 12mm long
M5 screw 8mm long
M5 nuts
Cylinder house body
Cylinder house door
Locks
Base
4
Page 5
AREA HEATER - For Outdoor Use Only
Minimum Clearance from Combustible Surfaces*:
1000mm
500mm
1330mm
630mm
540mm
*Combustible materials are considered to be wood, compressed paper, plant fibres, plastic or other materials that are capable of being ignited and burned.
5
Page 6
TEST FIRING HEATER
Test fire heater, following the lighting instructions. Leak test all gas connections with soapy water. Soap bubbles indicate gas leakage. DO NOT use a match to test for gas leaks.
WARNING: White smoke may appear around the radiant head during the first minute of the initial firing.
TROUBLE SHOOTING
Problem Possible Causes Solution
No gas Replace cylinder
Main burner won’t light
NOTE: If the appliance cannot be adjusted to perform correctly it should not be used until serviced or repaired.
WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Any modifications or adjustments made to product without prior authority from the manufacturer will void any warranty claims. Read the installation, operating and maintenance instructions thoroughly before installing or servicing this equipment.
Low gas pressure Replace cylinder
Blockage in orifice Remove blockage
Manual valve not in ‘LOW’ or ‘HIGH’ position Position to ‘HIGH’
Exposure to rain Remove emitter and clean burner ports
LIGHTING INSTRUCTIONS
WARNING: White smoke may appear around the radiant head during the first minutes of the initial firing.
1. Ensure that the control knob is off. Slowly open the gas cylinder valve.
2. Push in control knob and turn anti-clockwise to ‘PILOT’. The rotary piezo will make a clicking sound.
3. Check for flame at the pilot. If pilot does not light immediately turn control knob to ‘OFF’ position and try again from the start. Allow 30 seconds between ignition attempts for gas to dissipate. Several attempts may be necessary.
Failure to follow this lighting procedure may result
in flame roll out beyond the emitter grid.
4. With the pilot alight keep control knob depressed for 10 seconds.
5. For minimum heat turn the control knob to ‘LOW’.
6. For maximum heat turn the control knob to ‘HIGH’.
7. To turn heater off, turn the control knob to ‘OFF’.
PILOT
OFF
HIGH
LOW
6
Page 7
SAFE APPLIANCE LOCATIONS
This appliance shall only be used in an above ground open-air situation with natural ventilation, without stagnant areas, where gas leakage and products of combustion are rapidly dispersed by wind and natural convection.
Any enclosure in which the appliance is used shall comply with the following:
An enclosure with walls on all sides, but at least one permanent opening at ground level and no overhead cover (see Example 1).
Within a partial enclosure that includes an overhead cover and no more than two walls (see Example 2 & 3).
Within a partial enclosure that includes an overhead cover and more than two walls, the following will apply:
At least 25% of the total wall area is completely open, and at least 30% of the remaining wall area is open and unrestricted.
In the case of balconies, at least 20% of the total wall area shall be and remain open and unrestricted (see Example 4 & 5).
The following figures are diagrammatic representations of outdoor areas. Rectangular areas have been used in these figures – the same principles apply to any other shaped area.
7
Page 8
For any queries or assistance call
Customer Service
(Australia Only)
1300 174 876
Hours of operation:
Monday to Friday 8am - 5pm EST
Do not return to place of purchase.
Keep your purchase receipt, this will be required to
make any claims under the 12 month warranty.
Loading...