If you smell gas:
1. Shut off the gas to the appliance.
2. Extinguish any open flame.
3. If odour continues, immediately call your gas supplier.
WARNING
Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage.
Read the instructions thoroughly before installing or servicing this equipment.
FOR OUTDOOR USE ONLY PROPANE GAS
Model No. AH1069ODS, AH1060ODS
The ideal solution for extending the season of outdoor entertaining
Creates a stylish and attractive ambience
Direct ignition
Includes a safety ‘tip-over’ switch that halts supply of gas to the unit should it be accidently knocked over
Oxygen depletion system for enhanced safety
Stainless steel burner for extra long-term reliability
Complete with hose and POL regulator
Efficient and powerful 27.5MJ/h output
Adjustable heat output
Operates for approximately 17 hours on a properly filled 9Kg Propane cylinder
For outdoor use only
Gas certified to Australian standards
Page 2
2
Installation, Operation and Maintenance Instructions
INSTALLATION
3. Proper clearance from combustible materials must be maintained at all times. The minimum clearances are as follows:
Minimum Clearance from Combustibles:
Side 500 mm Rear 500 mm
Ceiling 1000 mm
Combustible materials are considered to be wood, compressed paper, plant fibres, plastic, plexiglas or other materials capable of being ignited and burned.
Such materials shall be considered combustible even though flame proofed, fire-retardant treated or plastered. Additional clearance may be required for glass, painted surfaces and other materials which may be damaged by radiant or convection heat.
4. Heaters must be placed on a level and adequate footing and be readily accessible.
5. The gas manifold supply pressure must be regulated at 2.75 kPa utilising an AGA approved regulator (supplied with heater).
6. The appliance must be inspected before each use, and at least annually by a qualified service person.
a. The appliance area must be kept clear and free
of combustible materials, gasoline and other flammable vapours and liquids.
b. Gas orifices and burner must be kept clear of dirt
and cobwebs. Flow of combustion and ventilation air through the perforated portions of the heater must not be obstructed. Cleaning with a soft brush before use and at least every six months is recommended.
c. All gas connections should be checked for
leaks utilising a soap solution. Never use a flame for this purpose.
d. The flame pattern should be visually checked
whenever heater is operated. If flames extend beyond surface of the guard the appliance should be turned off and should not be operated again until the unit is serviced and or repaired.
e. Any cleaning agent used on the heater should be of
a non-combustible and non-corrosive nature.
f. The stainless steel emitter normally does not require
cleaning and should NEVER be painted.
Important Safety Rules
This appliance must only be used in a well ventilated area.
1. This appliance shall not be installed or used indoors, in buildings, garages or any other enclosed area.
2. DO NOT place articles on or against this appliance.
3. DO NOT use or store flammable materials near this appliance.
4. Children and adults should be alerted to the hazards of high surface temperatures, burns and clothing ignition.
5. Children should be carefully supervised when they are in the area of the appliance.
6. NEVER hang anything including clothes or other flammable items on the appliance.
7. DO NOT operate this appliance unless it is fully assembled with burner guard in place.
8. DO NOT SPRAY AEROSOLS IN THE
VICINITY OF THIS APPLIANCE WHILE IT IS IN OPERATION.
9. Installation and repair should be done by a qualified service person. The appliance must be inspected before use and at least annually by a qualified service person. It is imperative that control compartment, burners and circulating air passages of the heater be kept clean.
Prior to assembling your appliance, the following must be reviewed. Compliance with the following should result in satisfactory heater operation. This instruction manual should be retained for future reference. The installation must conform with local codes or authority having jurisdiction.
1. The patio heater is intended for heating residential and non-residential outdoor spaces. The installation must conform with local codes and with the Australian Standard AS/NZS 5601.
2. Adequate clearance around air openings into the combustion chamber, clearances from combustible materials, provisions for accessibility and for combustion and ventilating air supply must be maintained at all times when the appliance is operating.
Page 3
3
7. The hose must be protected from contact with hot or sharp surfaces both during use and while in storage. The hose assembly should be visually inspected prior to each use of the heater. If excessive abrasion or wear is evident, or the hose is cut, it must be replaced prior to operating the heater. The replacement hose assembly may be obtained from the manufacturer.
8. DO NOT use any pressure regulator or hose assembly other than those supplied with the appliance. Replacement pressure regulator and hose assembly must be those specified. Replacement parts maybe obtained from the manufacturer or your local sales representative.
9. Installation and use of this heater must conform with local codes and AS/NZS 5601.
10. This heater is designed to operate with a standard 9Kg propane cylinder with Approved Cylinder Connection.
11. The valve outlet must be maintained in good condition. When the cylinder is not in use, be sure to cover it with a dust cap. A leak test should be performed with soapy water whenever connecting a new cylinder. NEVER use a match to test for leaks.
12. The propane cylinder must be turned off whenever the heater is not in use. When the heater is to be stored indoors, the propane cylinder and the heater must be disconnected and the cylinder stored in accordance with the Standard for Storage and Handling of Liquefied Gases.
13. The appliance has been designed with several safety features which include a tip over switch.
IMPORTANT
Storage of an appliance indoors with the cylinder attached is only permitted if the size of the cylinder complies with AS/NZS 1596; otherwise cylinders must be stored outdoors in a well ventilated area.
The guards are fitted to this appliance to reduce the risk of fire or injury from burns and no part of it should be removed.
This appliance must be protected from exposure to rain.
Any modification to the heater not described in the installation instructions may compromise the safety of this appliance. Special concern is as follows:
(1) DO NOT bypass thermocouple safety burner;
(2) DO NOT operate heater without the guard;
Clothing or other flammable materials should not be hung from the heater, or placed on or near the heater. The area above the burner may be extremely hot. Direct contact with these metal surfaces should be avoided in order to prevent burns or clothing ignition.
Screw the coupling nut of regulator into the cylinder valve outlet.
POL CYLINDER CONNECTION DEVICE
Type of Gas Propane
Consumption 27.5 MJ/h
Operating Pressure 2.75 kPa
Injector Size 1.48 mm
Heater specifications can be found on the data label.
Page 4
4
Tools Required
Phillips head screwdriver, 2 Adjustable spanners
Note: Remove any transit protection material
STEP 1
Attach the brackets onto the base with four M8 x 16mm bolts, then attach the cylinder cover with eight M5 x 10mm screws and nuts.
STEP 2
Place the burner head on the cylinder cover and secure with four M4 x 8mm screws.
STEP 3
Position the mesh guard around the burner with the lift up door in front of the control knob locating the wire pins into the cylinder cover holes then secure with the wing nut on top.
STEP 4
Attach the hose and regulator to the underside of the burner head, tightening the hose fitting thread firmly. Leak test this connection with a soapy water solution before attempting to light the heater.
AREA HEATER ASSEMBLY
BRACKETS
BASE
WING NUT
BURNER HEAD
CYLINDER COVER
HOSE AND REGULATOR
MESH GUARD
PARTS LIST
NAME QTY
Mesh Guard 2
Burner Head 1
Cylinder Cover 1
Hose and Regulator 1
Base 1
Base Brackets 4
Wing Nut 1
M8 x 16mm Bolt 6
M8 Nut 2
M5 x 10mm Screws & Nuts 8
M4 x 8mm Screws 4
Page 5
5
AREA HEATER - For Outdoor Use Only
Minimum Clearance from Combustible Surfaces*:
*Combustible materials are considered to be wood, compressed paper, plant fibres, plastic or other materials that are capable of being ignited and burned.
500mm
1400mm
850mm
450mm
1000mm
Page 6
6
TEST FIRING HEATER
Test fire heater, following the lighting instructions. Leak test all gas connections with soapy water. Soap bubbles indicate gas leakage. DO NOT use a match to test for gas leaks.
TROUBLE SHOOTING
Problem Possible Causes Solution
Main burner will not light
No gas Replace cylinder
Low gas pressure Replace cylinder
Blockage in orifice Remove blockage
Manual valve no in LOW or HIGH position Position to HIGH
Exposure to rain Remove emitter and clean burner ports
Note: If the appliance cannot be adjusted to perform correctly it should not be used until serviced or repaired.
White smoke may appear around the emitter grid during the first minute of initial firing.
Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage.
Any modifications or adjustments made to product without prior authority from the manufacturer will void any warranty claims. Read the installation, operating and maintenance instructions thoroughly before installing or servicing this equipment.
WARNING
LIGHTING INSTRUCTIONS
1. Ensure that the control knob is off. Slowly open the gas cylinder valve.
2. Push in control knob and turn anti-clockwise to LO whilst simultaneously pressing the red ignitor button.
3. Check for flame at the burner. If burner does not light immediately turn control knob to OFF position and try again from the start. Allow 30 seconds between ignition attempts for gas to dissipate. Several attempts may be necessary.
Failure to follow this lighting procedure may result
in flame roll out beyond the emitter grid.
4. With the burner alight keep control knob depressed for 15 seconds.
5. For maximum heat push in and turn the control knob to HI.
6. To turn heater off, turn the control knob to OFF.
LO
HI
OFF
Page 7
7
The following figures are diagrammatic representations of outdoor areas. Rectangular areas have been used in these figures – the same principles apply to any other shaped area.
SAFE APPLIANCE LOCATIONS
This appliance shall only be used in an above ground open-air situation with natural ventilation, without stagnant areas, where gas leakage and products of combustion are rapidly dispersed by wind and natural convection.
Any enclosure in which the appliance is used shall comply with the following:
An enclosure with walls on all sides, but at least one permanent opening at ground level and no overhead cover (see Example 1).
Within a partial enclosure that includes an overhead cover and no more than two walls (see Example 2 & 3).
Within a partial enclosure that includes an overhead cover and more than two walls, the following will apply:
At least 25% of the total wall area is completely open, and at least 30% of the remaining wall area is open and unrestricted.
In the case of balconies, at least 20% of the total wall area shall be and remain open and unrestricted (see Example 4 & 5).