SPECIFICATIONS
Infrared Gas Heaters For Industry Since 1949
OW INTENSITY
L
PTS/PTU Series Tube Heaters
Positive Pressure
PTU Series
Single Stage Input
Two Stage Input
SPACE-RAY®…A TRUSTED NAME IN INFRARED HEATING
At Space-Ray, industrial comfort heating is a challenge we take seriously. We have
been manufacturing gas-fired infrared heating systems since 1949. The quality and
performance of our heaters are based on over 50 years of field experience and exposure to a wide variety of industrial heating problems. Our reputation is built upon a
solid track record for providing radiant efficient, easy-to-install and high quality infrared heating equipment.
Space-Ray infrared tube heaters are ideal for complete building heat or even spot heating needs.The best applications include:manufacturing plants, warehouses, auto dealerships, aircraft hangars, loading docks, weld shops, truck or auto service areas, car
washes, fire stations, greenhouses, gymnasiums, garages, machine shops, tennis
courts, swimming pools, maintenance shops, farm buildings and many many more.
HEATING TECHNOLOGY FOR THE NEXT MILLENNIUM
Space-Ray infrared heaters heat like the sun by transferring radiant heat energy directly
to the areas to be heated. Radiant energy is absorbed by concrete floors, objects and
people, and re-radiated to warm the surrounding area. This principle is similar to the sun’s
radiant heat energy heating the Earth but not the upper atmosphere.This heating technology creates a comfort zone at floor level, not at the ceiling, and is much more efficient
than conventional forced air heating systems.
PTS Series
30%-50% FUEL SAVINGS
A highly radiant efficient Space-Ray infrared heating system can normally save a building owner 30% to 50% in annual fuel costs when compared to forced air heating systems. In fact, some Space-Ray customers report fuel savings as high as 70% with a
payback of less than one year. With a Space-Ray system, your investment payback accrues not only from reduced energy costs, but from reduced maintenance costs, too.
So when you think industrial heating, think Space-Ray. Call us at 1-800-438-4936 for
the name of our representative nearest you.
TS/PTU SERIES FEATURES
P
GENERAL FEATURES
• 8 different Btu/hr sizes and more than 100
different configurations to custom design your
nfrared heating system
i
• Single Stage or Two Stage Input Controls
• CSA design certified
Vented or indirect vented operation
•
• Sidewall or through-the-roof venting
• Natural and propane gas models
PUSH THROUGH SYSTEM (
Positive Pressure)
• Products of combustion are pushed through the
combustion chamber
• Tube Integrity Safety System (TISS)
• No draft hoods, totally enclosed
combustion chamber
• Blower motor totally enclosed in the burner box.
Ideal for applications where minimal noise (less
than 60dB) is desired
• Heavy duty permanently lubricated, ball bearing
blower motor for maintenance-free operation
BURNER SYSTEM
• Heavy-duty cast iron burner
• 10-year limited warranty on burner
• Inside or outside air for combustion
• Up to 40 ft. outside combustion air duct capability
• Standard 4” combustion air collar
• Reliable direct spark ignition system and 100%
gas shut-off safety control
• Pre-purge and post-purge function
• State-of-the-art step opening redundant
combination gas valve for quiet ignition and
added safety
• Diaphragm air switch for proof of venting before
gas flow and ignition
• Diagnostic monitoring light system
• Burner inspection sight glass
• Line voltage or 24V thermostat connection
RADIANT EMITTER TUBE SYSTEM
• 4” O.D. heavy-duty calorized aluminized steel or
alumi-therm steel combustion chamber (10 feet)
nd heavy duty hot-rolled steel radiant emitter
a
tubes
• Optional calorized aluminized steel (ALC)
radiant emitter tubes
• 3-year limited warranty on the emitter tubes
• Suitable for horizontal or angle mounting up to 45°
• Optional 90° elbows
• Up to 40 feet sidewall vent capacity
REFLECTOR SYSTEM
• Highly efficient aluminum reflectors with
reflectivity rating of 97.5%
• Optional end, corner, side and U-bend reflectors
• Optional decorative grille
• Individual reflectors can be rotated up to 45° to
direct heat where needed
• Easy-to-use mounting brackets and wire hangers
Energy efficient PTS150-40 installed in a manufactur-
ing application.
MODEL SELECTIONS
SINGLE
STAGE
GAS
N5 / L5
N7 / L7
BTU/HR
INPUT
BURNER
PRESSURE
MODEL
PTS/U 40 40,000 40,000 25,000
PTS/U 50 50,000 50,000 30,000
PTS/U 75 75,000 75,000 50,000
PTS/U 100 100,000 100,000 65,000
CONTROL SUFFIX
TYPE
NATURAL 3.5” W.C. 5” W.C* 14” W.C.
PROPANE 10” W.C. 11” W.C.* 14” W.C.
®
TWO STAGE
Btu/hr
High Input
Btu/hr
Low Input
*Indicate model number based on Btu/hr input (e.g., 100,000 Btu/hr), total emitter length, (e.g., 40 feet) and gas type
(e.g., natural gas single stage input).The unit selection for a straight tube would be PTS100-40-N5 and for a U-tube
would be PTU100-40-N5. **Available only on PTS models.
TYPE OF GAS
Natural / Propane
Natural / Propane
ALC Option: All calorized aluminized steel (ALC) radiant emitter tubes
for ALC option the model number would be PTS100-40-ALC-N5. Note: for Carwashes, Dairy Barns, Greenhouses,
Swimming Pools,WasteWaterTreatmentPlants, and other high humidity / corrosive environments, theALC optionwith
all calorized aluminized tubes is recommended.
SUPPLY PRESSURE
MIN MAX
TOTAL EMITTER TUBE LENGTH*
10 FT** 20 FT 30 FT 40 FT
X
X
X
X
X
X
X
VOLTAGE
120 VAC
60 HZ
X
SINGLE
STAGE
MODEL
PTS/U 125 125,000 125,000 80,000
PTS/U 150 150,000 150,000 100,000
PTS/U 175 175,000 175,000 110,000
PTS/U 200 200,000 200,000 125,000
AMPS
1.8
BTU/HR
INPUT
CONTROL OPTION DESCRIPTION
Single Stage Gas Valve - Single Stage Input
Two Stage Gas Valve - Two Stage Input - High/Low Fire
IGNITION
TYPE
DIRECT
SPARK
TWO STAGE
Btu/hr
High Input
Btu/hr
Low Input
FLUE
CONNECTION
4” Round 4” Round
TOTAL EMITTER TUBE LENGTH*
30 FT 40 FT 50 FT 60 FT 70 FT
X
X
OUTSIDE COMBUSTION
X
X
X
X
X
AIR CONNECTION
X
X
X
X
X