Gasboy SCII CPU PCB User Manual

SITE CONTROLLER II CPU INSTRUCTION SHEET
Use the following kits (C07047 and C07048) to replace the CPU board in a site controller. Each kit contains the following:
Site Controller II CPU Instruction Sheet, C35381
CPU board assembly C05852 (kit C07047) or C05328 (kit C07048)
PAL replacement kit containing CSGEN2a or CSGEN3
2. Remove the four Phillips screws from the sides of the site controller and remove the cover.
3. Disconnect all cables going to the CPU board (top board), making note of which cable goes to which connector. Remove the Phillips screws that secure the site controller CPU board and carefully remove the board.
4. Refer to the chart at right and insert the proper CSGEN chip on the memory board. Refer to drawing below for placement of CSGEN PAL. If memory board does not match drawing, do not change PAL.
data has been polled and/or backed up. If the system is a site
ALL
5. Set the jumpers on the CPU board to match the site's configuration.
6. Reassemble the site controller. Plug in the site controller and turn on power. Verify the site is working correctly.
C35381 Rev. 6253 1
SITE CONTROLLER II CPU PCB - C05852 OR CR5852
NOTE: C05852/CR5852 CPU PCB requires operating system version 2.0C or above, new memory PCB, C07041, and
Dsite 4.0B or above. If the CPU PCB is being installed at a Profit Point site, the Profit Point must be updated to version 2.0 or above.
2 C35381 Rev. 6253